Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Vet Radiol Ultrasound ; 64(5): 844-850, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37496365

RESUMO

Computed tomography is commonly utilized for investigation of rabbits, and more recently, for evaluating abdominal pathology. The spleen, however, is an often-overlooked organ, with limited information published. The aims of this retrospective, observational, study were to document the visibility, size, and shape of the normal rabbit spleen and potential correlations with signalment. Institutional imaging archives were reviewed for diagnostic-image-quality abdominal CT studies of rabbits. In 115 cases, the inclusion criteria were met. Pre- and postcontrast CT studies were evaluated by two reviewers for visibility of the spleen. For precontrast CT images, the interrater agreement for identification of the spleen was fair. For postcontrast CT images, interrater agreement was moderate. There were significantly more spleens clearly identified on postcontrast studies compared with precontrast CT. Splenic location, volume, shape, X-ray attenuation, and length were measured, and the splenic-volume-to-body-weight ratio was calculated. The mean splenic volume was 1 mL (range 0.2-3.9 mL), mean length 40 mm (range 20-61 mm), mean attenuation (precontrast CT 80 HU and postcontrast CT 320 HU), and mean splenic volume/body weight ratio was 0.5 mL/kg (range 0.17-1.2 mL/kg). There was a significant relationship between splenic volume and body weight, which was weakly positively correlated. There was no correlation between splenic volume, age, and sex. The most commonly identified splenic shapes were "banana", "tongue", and "elephant trunk". The rabbit spleen can be identified on CT images, but more reliably on postcontrast CT images, which underlines the usefulness of contrast-enhanced CT in this species.


Assuntos
Baço , Tomografia Computadorizada por Raios X , Coelhos , Animais , Baço/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/veterinária , Tomografia Computadorizada por Raios X/métodos , Abdome , Peso Corporal
2.
Vet Rec Open ; 9(1): e31, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35282422

RESUMO

Background: Contrast media in CT is widely used in dogs and cats to provide superior tissue delineation and increase the diagnostic capabilities. These contrast-enhanced imaging techniques are gaining popularity in rabbits; published studies reporting the safety of doing so are lacking. Methods: This retrospective observational study aimed to determine the incidence of adverse events following the intravenous administration of iodinated non-ionic contrast medium in 350 rabbits. The medical records of this subset of rabbits admitted between January 2009 and November 2018, that underwent CT examination and received intravenous contrast media, were evaluated. Results: From the 350 rabbits, 342 rabbits were still alive 7 days after the scan. A total of eight rabbits died within 7 days of the scan, seven of which within the first 24 h. All deaths were presumed to be sequelae to the diseases they were being investigated for and not thought to be related to the administration of intravenous contrast medium. Conclusions: The results indicated that the use of intravenous non-iodinated contrast medium was well tolerated and safe in rabbits undergoing conscious CT examination.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA