Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 170
Filtrar
1.
Eur J Vasc Endovasc Surg ; 52(2): 166-72, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27346443

RESUMO

OBJECTIVE: The aim of the study was to evaluate the feasibility and mid-term biological behavior of the novel customized aortic repair (CAR) method for endovascular aneurysm treatment. METHODS: CAR consists of exclusion of an aneurysm from the circulation using a custom-designed dog bone-shaped balloon, followed by aneurysm sac filling with an in situ curing polymer. After curing and balloon deflation, the circulation is restored through a patent cast neolumen. A liquid two-component polymer was injected via a small bore catheter under X-ray control into a surgically created aneurysm. In 50% of the procedures, a self expanding bare metal stent was placed in the polymer cast lumen. A novel animal model was established involving creation of an aneurysm by anastomosing a venous interposition graft into the common carotid artery of eight adult sheep. Two animals were excluded because of non-device related complications. The remaining six animals were monitored for 20 weeks with duplex sonograms performed monthly to assess blood flow and polymer cast lumen patency. After the animals were sacrificed the polymer cast, common carotid artery, and the brain in the carotid outflow tract were removed for histological assessment. RESULTS: In four of the six animals, the aneurysm was successfully excluded using CAR with uneventful follow up. The aneurysm sac was filled incompletely in two animals, resulting in a stent malpositioning and cast lumen occlusion after 12 weeks in one case, and a type 1 endoleak in the other. All six animals survived for 20 weeks. Neither migration nor expansion of the polymer cast was observed and the polymer was demonstrated to be biocompatible and non-thrombogenic. Polymer emboli were not detected in the brain or meninges after sacrifice. CONCLUSIONS: The feasibility and mid-term biological safety of the CAR method for minimally invasive aneurysm repair was demonstrated using a simulated aneurysm survival model.


Assuntos
Angioplastia com Balão/métodos , Aneurisma Aórtico/cirurgia , Animais , Prótese Vascular , Implante de Prótese Vascular , Artéria Carótida Primitiva/cirurgia , Modelos Animais de Doenças , Feminino , Polímeros , Radiografia Intervencionista , Ovinos , Stents
2.
Zentralbl Chir ; 140(5): 525-9, 2015 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-26274774

RESUMO

STUDY DESIGN: We present a monocentric analysis of the lumbar artery compression syndrome (LACS) in the form of a case report. OBJECTIVES: Literature information was collected about the symptoms, diagnosis and treatment of this rare disorder in the context of the existing data. METHODS: The current medical literature includes only one report about three cases of LACS, collected over 20 years in France and Germany. We compared these cases with the experience of the European Vascular Center Aachen-Maastricht. RESULTS: The symptoms of this rare disorder are dominated by reversible, motion-dependent paralysis of the legs. Compression of the right lumbar arteries by muscular fibres or connective tissue is a fundamental cause. CONCLUSION: Surgical treatment, which means decompression of the lumbar arteries via a thoracolaparotomy, is an appropriate therapy with few complications and good long-term results.


Assuntos
Arteriopatias Oclusivas/etiologia , Isquemia/etiologia , Perna (Membro)/irrigação sanguínea , Vértebras Lombares/irrigação sanguínea , Paraplegia/etiologia , Isquemia do Cordão Espinal/etiologia , Adulto , Angiografia , Síndrome da Artéria Espinal Anterior/diagnóstico , Síndrome da Artéria Espinal Anterior/etiologia , Síndrome da Artéria Espinal Anterior/cirurgia , Arteriopatias Oclusivas/diagnóstico , Arteriopatias Oclusivas/cirurgia , Diagnóstico Diferencial , Feminino , Humanos , Isquemia/diagnóstico , Isquemia/cirurgia , Pessoa de Meia-Idade , Paraplegia/diagnóstico , Paraplegia/cirurgia , Parestesia/diagnóstico , Parestesia/etiologia , Parestesia/cirurgia , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/cirurgia
3.
Eur J Vasc Endovasc Surg ; 48(5): 521-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25150442

RESUMO

OBJECTIVE: The aim of this study is to present experience with 10 patients with symptomatic aberrant subclavian artery (ASA) and aneurysm of ASA who underwent surgical treatment. METHODS: From 2008 to 2011 10 patients with symptomatic aberrant subclavian artery (mean age 60 years [range 24-90 years]) were studied. Symptoms were dysphagia (n = 7), dyspnea (n = 4), acute chest pain (n = 1), respiratory distress syndrome (n = 1), superior cava syndrome, and shock (n = 1). Six patients had aneurysm formation of the ASA (mean diameter of 7.1 cm [range 3.0-12.4 cm]; rupture [n = 1], dissection [n = 1]). All data were analyzed retrospectively. RESULTS: Treatment was performed as a hybrid procedure in eight patients. This included thoracic endoluminal graft exclusion with revascularization of the ASA, a pure endovascular procedure with two occluders in one patient, and an open procedure in one patient with ligation of the aberrant artery through a thoracotomy. Three patients died during the early postoperative period owing to pulmonary complications. All three suffered from a symptomatic aneurysm, and two were treated as an emergency procedure. Median follow-up was 20 months (range 12-49 months). CONCLUSION: A symptomatic ASA and its associated aneurysmal formation should be excluded after diagnosis. In most cases, a hybrid procedure consisting of thoracic endografting and revascularization of the ASA is feasible.


Assuntos
Aneurisma/cirurgia , Anormalidades Cardiovasculares/cirurgia , Transtornos de Deglutição/cirurgia , Procedimentos Endovasculares , Artéria Subclávia/anormalidades , Adulto , Idoso , Idoso de 80 Anos ou mais , Aneurisma/complicações , Dissecção Aórtica/complicações , Dissecção Aórtica/cirurgia , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/cirurgia , Anormalidades Cardiovasculares/complicações , Transtornos de Deglutição/complicações , Procedimentos Endovasculares/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Stents , Artéria Subclávia/cirurgia , Resultado do Tratamento , Adulto Jovem
4.
Eur J Vasc Endovasc Surg ; 47(4): 349-56, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24485850

RESUMO

OBJECTIVES: To evaluate the effect of intraoperative guidance by means of live fluoroscopy image fusion with computed tomography angiography (CTA) on iodinated contrast material volume, procedure time, and fluoroscopy time in endovascular thoraco-abdominal aortic repair. METHODS: CTA with fluoroscopy image fusion road-mapping was prospectively evaluated in patients with complex aortic aneurysms who underwent fenestrated and/or branched endovascular repair (FEVAR/BEVAR). Total iodinated contrast material volume, overall procedure time, and fluoroscopy time were compared between the fusion group (n = 31) and case controls (n = 31). Reasons for potential fusion image inaccuracy were analyzed. RESULTS: Fusion imaging was feasible in all patients. Fusion image road-mapping was used for navigation and positioning of the devices and catheter guidance during access to target vessels. Iodinated contrast material volume and procedure time were significantly lower in the fusion group than in case controls (159 mL [95% CI 132-186 mL] vs. 199 mL [95% CI 170-229 mL], p = .037 and 5.2 hours [95% CI 4.5-5.9 hours] vs. 6.3 hours (95% CI 5.4-7.2 hours), p = .022). No significant differences in fluoroscopy time were observed (p = .38). Respiration-related vessel displacement, vessel elongation, and displacement by stiff devices as well as patient movement were identified as reasons for fusion image inaccuracy. CONCLUSION: Image fusion guidance provides added value in complex endovascular interventions. The technology significantly reduces iodinated contrast material dose and procedure time.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma Aórtico/cirurgia , Procedimentos Endovasculares , Idoso , Idoso de 80 Anos ou mais , Angiografia/instrumentação , Angiografia/métodos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Meios de Contraste/uso terapêutico , Procedimentos Endovasculares/métodos , Feminino , Fluoroscopia/métodos , Humanos , Masculino , Pessoa de Meia-Idade
5.
J Robot Surg ; 18(1): 191, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38693330

RESUMO

Robotic surgery has become increasingly prevalent in general surgery practice. While previous studies have shown the safety and efficacy of robotic assistance in laparoscopic general surgery procedures, few studies have evaluated the temporal and regional trends in implementation. In our retrospective population-based study, we aim to evaluate the national trends in robotic surgery. National Inpatient Database (NIS 2009-2014) was used to identify adults who underwent robotic assisted surgery (ICD 9 codes 17.41 to 17.49). Robotic procedures related to seven abdominal organ systems were compared against the trends of Urology, Gynaecologic, and Orthopedic robotic procedures. Discharge weights were applied to calculate National temporal trends separated by hospital size, teaching status and US geographic region. 894,163 patients received a robotic assisted procedure between 2009 and 2014 with 64% increase in utilization. The largest percent change was witnessed in biliary robotic procedures with 2984% change in utilization, followed by hernia (1376%). Lowest percent change was witnessed in esophageal procedures with 114% increase. Medium sized hospitals had the largest change in robotic utilization (41%), with large institutions seeing 18% decrease. Gastric procedures were the most common robotic procedure performed at small institutions (7917 total cases; 316%). Large institutions saw an overall decrease in gastric (- 47%), esophageal (- 17%), small and large intestinal (-16%), and hepatic (- 7%) robotic procedures. Rural non-teaching hospitals saw the largest increase in robotic surgery (274%). Urban non-teaching hospitals saw a decrease of 29%. While urban teaching institutions saw a 20% and 6% increase in gynecological and urological procedures, an overall decrease was seen in esophageal (- 10%), gastric (- 12%), intestinal (- 11%), hepatic (- 17%), biliary (- 10%), pancreatic (- 11%) and hernia procedures (- 14%). Biliary procedures saw the largest increase in rural institutions (740 cases; 392%), followed by hernia (144% increase). South region of the nation had the largest increase in robotic procedures (23%). No change was seen in the use of robotic surgery in the northeast region with the midwest and west seeing an overall decrease (- 4% and - 22%, respectively). Our study highlights the increase in use of robotics for both general and specialty surgery, with an increase in utilization over time. Increased incidence of robotic surgery in smaller, rural institutions with overall decrease in larger, urban teaching hospitals suggests increasing comfort in robotic surgery in the community setting. Further studies are necessary to evaluate the factors associated with increased utilization in smaller institutions.


Assuntos
Procedimentos Cirúrgicos Robóticos , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Procedimentos Cirúrgicos Robóticos/tendências , Procedimentos Cirúrgicos Robóticos/métodos , Humanos , Estudos Retrospectivos , Estados Unidos , Feminino , Masculino , Adulto , Pessoa de Meia-Idade
6.
Eur J Vasc Endovasc Surg ; 43(6): 675-80, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22436262

RESUMO

OBJECTIVES: Customized aortic repair (CAR) is a new concept for endovascular aortic aneurysm repair in which a non-polymerised elastomer is injected to fill the aneurysm sac around a balloon catheter. Amongst other variables, the thrombogenicity of the elastomer should be tested, before further clinical experiments can take place. The aim of this human ex vivo study was to measure the thrombogenicity of the elastomer and to compare it to expanded polytetrafluoroethylene (ePTFE). DESIGN AND MATERIALS: In a validated ex vivo model, non-anticoagulated blood was drawn from the antecubital veins of 10 healthy donors with a 19-gauge needle. It was drawn through elastomer tubes and through ePTFE Gore-Tex vascular grafts, both 60 cm long and with an inner diameter of 3 mm. METHODS: Fibrinopeptide A (FPA) and P-selectin expression was measured in blood samples, collected at the end of the grafts. After the experiments, the deposition of platelets and fibrin onto the grafts was visualised by scanning electron microscopy. RESULTS: For these graft types, a progressive increase in FPA production was observed in time. No significant difference was observed between the elastomer and ePTFE grafts (p > 0.05). No increase in P-selectin expression, and thereby no platelet activation, was observed in the perfusate of either grafts (p > 0.05). By scanning electron microscopy, numerous platelet aggregates were observed on the ePTFE grafts, whereas just a few adhered platelets and no aggregates were observed in the elastomer grafts. CONCLUSIONS: The elastomer in its current formulation has a low thrombogenicity, comparable to ePTFE, making it an ideal substance for endovascular aneurysm sac filling. Further research should clarify the feasibility of CAR in vivo.


Assuntos
Aneurisma Aórtico/terapia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Dimetilpolisiloxanos/administração & dosagem , Procedimentos Endovasculares/instrumentação , Politetrafluoretileno , Elastômeros de Silicone/administração & dosagem , Trombose/prevenção & controle , Adulto , Aneurisma Aórtico/sangue , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/efeitos adversos , Dimetilpolisiloxanos/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Fibrina/metabolismo , Fibrinopeptídeo A/metabolismo , Humanos , Injeções , Masculino , Microscopia Eletrônica de Varredura , Selectina-P/sangue , Adesividade Plaquetária , Desenho de Prótese , Elastômeros de Silicone/efeitos adversos , Trombose/sangue , Trombose/etiologia , Trombose/patologia , Fatores de Tempo , Adulto Jovem
9.
Zentralbl Chir ; 137(5): 418-24, 2012 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-23136101

RESUMO

During the past two decades, minimally invasive endovascular procedures have changed therapeutic strategies. Such techniques have now become the method of choice for practically all vascular and aortic pathologies. This development is especially apparent in the treatment of aortic aneurysms. The purpose of this report is to provide a critical review about the current standard of care of abdominal and thoracic aorta based on an electronic Medline literature search. For elective infrarenal aneurysms, endovascular aneurysm repair (EVAR) has become a widely accepted alternative to open repair in cases with appropriate morphology. Currently, fenestrated (FEVAR) or branched endografts offer promising short- and mid-term results in juxtarenal aneurysms, however, these techniques are complex, technically challenging, and expensive. The alternative chimney or sandwich graft technique are becoming more common because they are feasible using standard endografts. Thoracic endovascular aortic repair (TEVAR) is already the gold standard for some descending pathologies. Complex thoracoabdominal aneurysms still require open surgery in centres of excellence, whereby, total endovascular repair or hybrid procedures have proved to be feasible in such specialist centres for selected patients.


Assuntos
Angioplastia/métodos , Aorta/cirurgia , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Stents , Prótese Vascular , Terapia Combinada/métodos , Comportamento Cooperativo , Humanos , Comunicação Interdisciplinar , Desenho de Prótese
12.
Eur J Vasc Endovasc Surg ; 40(5): 589-95, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20739199

RESUMO

OBJECTIVES: Spinal cord ischemia after open surgical repair for rAAA is a rare event. We estimated the current incidence and tried to identify risk factors. We also report a new case. METHODS: Group A consisted of 10 reports on open repair for rAAA from 1980 until 2009. Only series of ≥100 patients were considered to estimate the incidence. Thirty three case reports from 1956 until 2009 were identified (group B). Case reports from group B were not encountered in group A. Group B patients were stratified according to the type of neurological deficit as described by Gloviczki (type I complete infarction and type II infarction of the anterior two third). RESULTS: Group A consisted of 1438 patients. In group A 86% were male with a mean age of 72.1 years. The incidence of post-operative paraplegia was 1.2% (range 0-2.8%). In-hospital mortality was 46.9%. Of the 33 patients of group B were 86% male with a mean age of 68.0 years. Most patients developed a type I (42%) or type II (33%) deficit. In-hospital mortality was 51.6%. No significant differences between different types were encountered. CONCLUSION: Spinal cord ischemia after ruptured AAA is a rare complication with an incidence of 1.2% (range 0-2.8%).


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Ruptura Aórtica/cirurgia , Paraplegia/epidemiologia , Isquemia do Cordão Espinal/epidemiologia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Mortalidade Hospitalar , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Paraplegia/etiologia , Fatores de Risco , Isquemia do Cordão Espinal/etiologia
13.
Eur J Vasc Endovasc Surg ; 40(1): 65-70, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20382549

RESUMO

OBJECTIVE: This study aimed to test a percutaneous technique for aneurysm-sac filling by means of in situ polymerisation in an in vivo model. DESIGN: Aortic Customize is a new endovascular treatment concept for aortic aneurysms: a non-cross-linked liquid elastomer is injected to fill the aneurysm sac around a balloon-catheter. With this method, a compliant elastomer mould with a patent lumen is created. MATERIAL: The formulation used in the experiments consisted of a two-component addition-cure liquid-silicone formulation, based on vinyl-terminated polydimethylsiloxane (PDMS). METHODS: The concept of aneurysm-sac filling was tested in vivo in porcine experiments (n = 3). RESULTS: In vivo porcine experiments with the sac-filling application showed successful exclusion of the created aneurysms with patent lumens and absence of endoleaks. The aneurysms were excluded successfully in the in vivo model, injecting elastomer through a 7-French catheter, filling up the entire aneurysm sac. CONCLUSIONS: These in vivo experiments demonstrate that the principle of aneurysm-sac filling by means of in situ curing is feasible, excluding the aneurysm and creating a new lumen. Further long-term animal experiments must be done prior to consideration of clinical application.


Assuntos
Aneurisma da Aorta Abdominal/terapia , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/métodos , Prótese Vascular , Cateterismo , Dimetilpolisiloxanos/administração & dosagem , Elastômeros de Silicone/administração & dosagem , Animais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia , Modelos Animais de Doenças , Estudos de Viabilidade , Injeções Intralesionais , Desenho de Prótese , Suínos
14.
Eur J Vasc Endovasc Surg ; 39(4): 410-6, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20060752

RESUMO

OBJECTIVES: This study investigated the relation between abdominal aortic aneurysm (AAA) wall stress, AAA growth rate and biomarker concentrations. With increasing wall stress, more damage may be caused to the AAA wall, possibly leading to progression of the aneurysm and reflection in up- or downregulation of specific circulating biomarkers. Levels of matrix metalloproteinase-9, tissue inhibitor of matrix metalloproteinase-1, C-reactive protein and alpha 1-antitrypsin were therefore evaluated. METHODS: Thirty-seven patients (maximum AAA diameter 41-55mm) with two, three or four consecutive computed tomography angiography (CTA) scans were prospectively included. Diameter growth rate in mm/year was determined between each pair of two sequential CTA scans. AAA wall stress was computed by finite element analysis, based on the first of the two sequential CTA scans only (n=69 pairs). Biomarker information was determined in 46 measurements in 18 patients. The relation between AAA diameter and wall stress was determined and the AAA's were divided into three equally sized groups (relative low, medium and high stress). Growth rate and biomarker concentrations were compared between these groups. Additionally, correlation coefficients were computed between absolute wall stress, AAA growth and biomarker concentrations. RESULTS: A relative low AAA wall stress was associated with a lower aneurysm growth rate. Growth rate was also positively related to MMP-9 plasma concentration (r=0.32). The average MMP-9 and CRP concentrations increased with increasing degrees of relative wall stress, although the absolute and relative wall stress did not correlate with any of the biomarkers. CONCLUSION: Although lower relative wall stress was associated to a lower AAA growth rate, no relation was found between biomarker concentrations and wall stress. Future research may focus on more and extensive biomarker measurements in relation to AAA wall stress.


Assuntos
Aneurisma da Aorta Abdominal/sangue , Aneurisma da Aorta Abdominal/patologia , Proteína C-Reativa/metabolismo , Metaloproteinase 9 da Matriz/sangue , Idoso , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/sangue , Ruptura Aórtica/etiologia , Ruptura Aórtica/patologia , Aortografia/métodos , Biomarcadores/sangue , Progressão da Doença , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Estresse Mecânico , Fatores de Tempo , Inibidor Tecidual de Metaloproteinase-1/sangue , Tomografia Computadorizada por Raios X , Regulação para Cima , alfa 1-Antitripsina/sangue
15.
J Cardiovasc Surg (Torino) ; 51(5): 693-9, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20924330

RESUMO

Marfan Syndrome is a heritable disorder of connective tissue leading to aortic aneurysms and other cardiovascular complications associated with reduced life expectancy. Marfan patients with thoracic aortic aneurysms (TAAs) or with thoracoabdominal aortic aneurysms (TAAAs) should be treated by means of open surgery, requiring an extensive protocol, including extracorporeal circulation, neuromonitoring and adjunctive modalities to provide organ protection. Then, open surgical repair of TAA(A)s are associated with excellent results. However, in the last time a gradual change to endovascular treatment in Marfan patients is observable. Particularly in patients with an increased surgical risk due to redo sternotomy or thoracotomy, endovascular treatment might be an alternative due to its less invasive approach. Consequently, thoracic endovascular aortic repair comprises a therapeutic alternative in individual situations even in Marfan patients, when the landing zones are safe and appropriate. In cases of failed endovascular therapy, however, conversion to open surgery remains still an option with acceptable results, although the distal and proximal clamping positions change inappropriate with larger extensions due to the aortic stent.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Síndrome de Marfan/complicações , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/etiologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Humanos , Pessoa de Meia-Idade , Seleção de Pacientes , Reoperação , Stents , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
16.
J Cardiovasc Surg (Torino) ; 51(3): 369-75, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20523287

RESUMO

AIM: According to the results of the large trials on carotid endarterectomy (CEA), this type of surgery is only warranted if perioperative mortality and morbidity are kept considerably low. Less attention has been paid to methods of cerebral protection during CEA, although intraoperative transcranial Doppler (TCD) can visualise intracerebral microemboli (MES) during routine carotid dissection, although MES occur throughout the CEA, only those during dissection are related to neurological outcome. Prevention of MES by means of early control of the distal internal carotid artery dislodging from the carotid artery plaque during dissection is very likely the mechanism behind an eventual benefit from this approach. Hence, the amount of MES might serve as a surrogate parameter for the risk of periprocedural neurological events. So, the aim of the present study was to evaluate whether early control of the distal carotid artery during CEA is capable of reducing the number of MES by means of a prospective randomised trial. METHODS: Twenty-eight patients (29 procedures) could be prospectively included in our study. Before surgery we randomly assigned the patients to two groups: group A (N.=12): CEA by means of early control of the distal internal carotid artery; group B (N.=17): CEA with dissection of the total carotid bifurcation before clamping the arteries. Periprocedurally, we continuously monitored the cerebral blood flow in the ipsilateral middle cerebral artery by means of TCD. Pre- and postoperative morbidity were independently verified by a neurologist <2 days before and not later than five days after the procedure. Values of microembolic signs during dissection were summarised with arithmetic means and standard deviations. For further analysis non parametric Wilcoxon test was performed between both methods. P-values <0.05 were considered as statistically significant. Wilcoxon test was performed to compare both methods concerning clamp- and procedure times. RESULTS: We performed EEA 26 times, in three patients a longitudinal arteriotomy with endarterectomy and patchplasty was performed, in one of these patients a shunt was necessary. In 12 twelve patients MES occurred during the dissection before clamping. Eight of these patients belonged to group B and four patients to group A. The mean number of MES during dissection for group A was 2.4 (SD 4.6; 5-15) and for group B 3.9 (SD 7.1; 2-28). There is no statistically significant difference in the Wilcoxon-test; P=0.4375. There was no patient showing reperfusion syndrom or clinical signs of a new cerebral infarction or any other neurological deficit. There were no other major complications like myocardial infarction or death as well as no minor complications like periphereal nerve lesions, bleeding or wound healing disturbance. CONCLUSION: In this prospective, randomised trial early control of the distal internal carotid artery did not reduce the occurrence of MES during dissection of the carotid bifurcation. Also, the total number of MES throughout the procedure and postoperatively was comparable between both groups. The procedure related times as well as the clinical outcome did not differ significantly. Thus, early control of the distal internal carotid artery has got no advantage but also no disadvantage as compared to the traditional CEA technique. However, a limitation of the study is the small number of patients included.


Assuntos
Doenças das Artérias Carótidas/cirurgia , Artéria Carótida Interna/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Embolia Intracraniana/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Doenças das Artérias Carótidas/fisiopatologia , Artéria Carótida Interna/fisiopatologia , Circulação Cerebrovascular , Constrição , Dissecação , Feminino , Alemanha , Humanos , Embolia Intracraniana/etiologia , Embolia Intracraniana/fisiopatologia , Masculino , Pessoa de Meia-Idade , Artéria Cerebral Média/fisiopatologia , Monitorização Intraoperatória/métodos , Exame Neurológico , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
17.
Zentralbl Chir ; 135(5): 421-6, 2010 Oct.
Artigo em Alemão | MEDLINE | ID: mdl-20976645

RESUMO

AIM: Stroke and paraplegia are devastating complications of thoracic and thoracoabdominal aortic surgery. The aim of this study was to analyse the value of transcranial Doppler ultrasound (TCD), electroencephalogram (EEG) and motor-evoked potentials (MEP) in preventing neurological complications. Moreover, the principles, technology and surgical protocols are described. PATIENTS AND METHODS: In 2009, 22 patients (4 females, 18 males) underwent thoracic or thoracoabdominal open aortic repair. We performed 2 arches with descending aortic replacement, 5 arches with TAAA repair, 2 type II, 9 type III, 3 type IV and one type V TAAA aortic repair. In 6 patients, the neuromonitoring included TCD, EEG and MEPs. In 15 patients only MEP monitoring was necessary. In one patient who was operated on in an emergency setting, neuromonitoring was not performed. The surgical approach was a left thoracotomy in 3 and a left thoracolaparotomy in 19 patients. The surgical protocol included cerebrospinal fluid drainage (n=22), moderate (n=19) or deep hypothermia (n=2), and extracorporeal circulation (n=21) with retrograde aortic perfusion and selective cerebral and/or viscerorenal perfusion. RESULTS: In 21 patients, the neuromonitoring could be established successfully. Using TCD and EEG, a relevant cerebral ischaemia during supraaortic clamping was excluded. With a mean distal arterial pressure of 60 mmHg, the MEPs remained adequate in 15 patients (68.2%). Increasing of the blood pressure restored the MEPs in one patient. In 5 patients (22.7%), a reimplantation of segmental arteries (n=4) or of the left subclavian artery (n=1) re-established spinal cord perfusion, as indicated by restored MEPs. We had no absent MEPs at the end of the procedures. Delayed paraparesis developed in 2 patients with a haemodynamic instability during the postoperative course. Paraplegia was not observed. CONCLUSION: TCD, EEG and MEPs are reliable techniques to unmask cerebral or spinal cord ischaemia during aortic surgery. Immediate operative strategies based on neuromonitoring information prevent neurological complications in aortic surgery.


Assuntos
Angioplastia , Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Isquemia Encefálica/prevenção & controle , Eletroencefalografia , Potencial Evocado Motor/fisiologia , Complicações Intraoperatórias/prevenção & controle , Monitorização Intraoperatória/métodos , Paraplegia/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Ultrassonografia Doppler Transcraniana , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos
18.
Chirurg ; 91(4): 337-344, 2020 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-31654105

RESUMO

BACKGROUND: Inguinal wound complications often cause postoperative morbidity and also mortality following vascular surgical interventions. The aim of this study was to report experiences and a comparison of the outcomes using rectus femoris muscle flaps (RFF) and sartorius muscle flaps (SMF). MATERIAL AND METHODS: A retrospective study was performed at two locations of a cross-border vascular center and all muscle flap interventions performed at the two centers within the vascular surgery department were reviewed. Primary outcomes were muscle flap survival, graft salvage and major amputations. RESULTS: A total of 44 RFFs were performed in 39 patients (mean age 67 years, 73% males) and 25 SMFs in 24 patients (mean age 64 years, 76% males). Wound infections were the most common indications for muscle flap reconstruction. At a mean follow-up of 24 months (±24) and 17 months (±20), respectively, comparable flap survival rates (91% vs. 84%), wound healing rates (72% vs. 83%), graft salvage (65% vs. 73%) and amputation rates (9% vs. 8%) were found. CONCLUSION: Muscle flap reconstruction is an effective way to cover groin defects resulting from deep wound infections after vascular surgery, achieving good results in a high-risk group of patients. No differences were found between SMF and RFF regarding amputation and graft loss. Both techniques can be safely performed, depending on the preference and experience of the surgical team. The RFF technique should be preferentially used to cover large tissue defects, whereas the SMF procedure can be preferred to cover smaller defects in the groin.


Assuntos
Virilha/cirurgia , Procedimentos de Cirurgia Plástica , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Músculo Quadríceps , Estudos Retrospectivos , Coxa da Perna
19.
J Cardiovasc Surg (Torino) ; 50(5): 665-8, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19282810

RESUMO

AIM: Outcome of carotid endarterectomy (CEA) is defined by mortality rate as well as the neurological outcome due to cerebral ischemia. Thus the aim of this study was to evaluate the role of the acute phase protein procalcitonin (PCT) as a predictor for neurological deficits after carotid endarterectomy. METHODS: Fifty-five patients with high grade stenosis of the internal carotid artery and interdisciplinary consensus for endarterectomy were followed. Neurological examination was performed before and after the procedure to analyze perioperative neurological deficits. Blood samples were obtained before and after CEA and procalcitonin was analyzed in 55 consecutive patients (65.5% symptomatic/34.5% asymptomatic). RESULTS: No perioperative or in-hospital death was observed. Major complications did not occur, two patients suffered from bleeding requiring surgical intervention and one patient had a temporary peripheral facial nerve lesion. Postoperative neurological examination revealed no new deficit, there was no significant change of PCT (level pre- and post-CEA (the mean preoperative PCT was 0.25 ng/mL [SD 0.78, min 0.1, max 4.3]; the mean postoperative PCT was 0.11 ng/mL [SD 0.06, min 0.1, max 0.5]). There was no association found between perioperative neurological deficit and PCT. CONCLUSIONS: The present study demonstrates that there is still not sufficient evidence to recommend PCT measurement as a predictor for perioperative neurological deficit during CEA.


Assuntos
Calcitonina/sangue , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Doenças do Sistema Nervoso/etiologia , Precursores de Proteínas/sangue , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Peptídeo Relacionado com Gene de Calcitonina , Estenose das Carótidas/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doenças do Sistema Nervoso/sangue , Exame Neurológico , Razão de Chances , Valor Preditivo dos Testes , Medição de Risco , Índice de Gravidade de Doença , Resultado do Tratamento
20.
Eur J Vasc Endovasc Surg ; 35(2): 181-6, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18069021

RESUMO

OBJECTIVE: We assessed the surgical outcome of descending thoracic aortic aneurysm repair (DTAA) and thoracoabdominal aortic aneurym (TAAA) repair in patients with Marfan syndrome. METHODS: During a six year period, 206 patients underwent DTAA and TAAA repair. In 22 patients, Marfan syndrome was confirmed. The median age was 40 years with a range between 18 and 57 years. The extend of the aneurysms included 6 DTAA (1 with total arch, 2 with distal hemi-arch), 11 type II TAAA (2 with total arch, 3 with distal hemi-arch), 4 type III and one type IV TAAA. All patients suffered from previous type A (n=6) or type B (n=16) aortic dissection and 15 already underwent aortic procedures like Bentall (n=7) and ascending aortic replacement (n=8). All patients were operated on according to the standard protocol with cerebrospinal fluid drainage, distal aortic and selective organ perfusion and monitoring motor evoked potentials. In patients undergoing simultaneous arch replacement (via left thoracotomy), transcranial Doppler and EEG assessed cerebral physiology during antegrade brain perfusion. In four patients circulatory arrest under moderate hypothermia was required. RESULTS: In-hospital mortality did not occur. Major postoperative complications like paraplegia, renal failure, stroke and myocardial infarction were not encountered. Mean pre-operative creatinine level was 125mmol/L, which peaked to a mean maximal level of 130 and returned to 92mmol/L at discharge. Median intubation time was 1.5 days (range 0.33-30 days). Other complications included bleeding requiring surgical intervention (n=1), arrhythmia (n=2), pneumonia (n=2) and respiratory distress syndrome (n=1). At a median follow-up of 38 months all patients were alive. Using CT surveillance, new or false aneurysms were not detected, except in one patient who developed a visceral patch aneurysm six years after open type II repair. CONCLUSION: Surgical repair of descending and thoracoabdominal aortic aneurysms provides excellent short- and mid-term results in patients with Marfan syndrome. In this series, a surgical protocol with cerebrospinal fluid drainage, distal aortic and selective organ perfusion and monitoring motor evoked potentials resulted in low morbidity and absent mortality. These outcomes of open surgery should be considered when discussing endovascular aneurysm repair in Marfan patients.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Síndrome de Marfan/complicações , Procedimentos Cirúrgicos Vasculares , Adulto , Anastomose Cirúrgica , Aneurisma da Aorta Torácica/etiologia , Aneurisma da Aorta Torácica/mortalidade , Drenagem , Estimulação Elétrica , Potencial Evocado Motor , Seguimentos , Humanos , Tempo de Internação , Síndrome de Marfan/mortalidade , Síndrome de Marfan/cirurgia , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Recidiva , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA