Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Acta Anaesthesiol Scand ; 61(4): 381-389, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28251605

RESUMO

BACKGROUND: The novel Totaltrack combines a supraglottic airway device with video laryngoscopic tracheal intubation. The intubation laryngeal mask Fastrach is an established device without visual control of intubation. We hypothesized that supraglottic ventilation success with Totaltrack would be similar to Fastrach, but intubation would be performed faster due to visual control of the procedure. METHODS: Fifty-five anaesthesiologists were randomized into one of two study arms: Fastrach Totaltrack. After a standardized introduction, six consecutive attempts of supraglottic ventilation and intubation attempts with each of one of the devices were performed on an airway manikin. The combined primary outcome was: time to supraglottic ventilation and time to ventilation after intubation. Additionally, success rate and learning curves were evaluated. RESULTS: Supraglottic time to ventilation was shorter when using the Fastrach compared to the Totaltrack (median: 7.8 s [confidence interval [CI]: 7.0-8.6 s] vs. 11 s [CI: 7.8-14.2 s], P < 0.001). Intubation was faster using the Fastrach compared to Totaltrack (median: 12.5 s, [CI: 10.1-14.9 s] vs. 23.3 s [CI: 21.5-25.1 s], P < 0.001). Success rate for supraglottic ventilation was comparable between Fastrach and Totaltrack (86-96%). Successful intubation via the device was 100% in Fastrach and ranged from 61% to 93% in Totaltrack, with a higher probability of successful intubation after four applications. CONCLUSION: In this manikin-based study the novel Totaltrack did not prove superior to Fastrach despite a similar design. Video laryngoscopic control of supraglottic ventilation and endotracheal intubation was prolonged using the Totaltrack. Clinical trials are mandatory to evaluate the role of the Totaltrack in airway management.


Assuntos
Intubação Intratraqueal , Máscaras Laríngeas , Manequins , Adulto , Anestesiologistas , Feminino , Humanos , Internato e Residência , Máscaras Laríngeas/efeitos adversos , Laringoscopia , Curva de Aprendizado , Masculino , Estudos Prospectivos , Respiração Artificial/métodos , Resultado do Tratamento , Gravação em Vídeo
2.
Clin Oral Implants Res ; 21(3): 350-6, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-20074240

RESUMO

OBJECTIVE: The aim of this study was to evaluate osseointegration of one-piece zirconia vs. titanium implants depending on their insertion depth by histomorphometry. MATERIAL AND METHODS: Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: (1) an uncoated zirconia implant, (2) a zirconia implant coated with a calcium-liberating titanium oxide coating, (3) a titanium implant and (4) an experimental implant made of a synthetic material (polyetheretherketone). In a split-mouth manner they were inserted in submerged and non-submerged gingival healing modes. After 4 months, dissected blocks were stained with toluidine blue in order to histologically assess the bone-to-implant contact (BIC) rates and the bone levels (BL) of the implants. RESULTS: All 48 implants were osseointegrated clinically and histologically. Histomorphometrically, BL in the crestal implant part did not differ significantly with regard to material type or healing modality. The submerged coated zirconia implants tended to offer the most stable crestal BL. The histometric results reflected the different healing modes by establishing different BL. The median BIC of the apical implant part of the zirconia and titanium group amounted to 59.2% for uncoated zirconia, 58.3% for coated zirconia, 26.8% for the synthetic material and 41.2% for titanium implants. CONCLUSIONS: Within the limits of this animal study, it is concluded that zirconia implants are capable of establishing close BIC rates similar to what is known from the osseointegration behaviour of titanium implants with the same surface modification and roughness.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Planejamento de Prótese Dentária , Osseointegração , Zircônio , Perda do Osso Alveolar , Animais , Materiais Revestidos Biocompatíveis , Cães , Implantes Experimentais , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA