Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 51
Filtrar
1.
Int J Mol Sci ; 22(16)2021 Aug 10.
Artigo em Inglês | MEDLINE | ID: mdl-34445294

RESUMO

Coupling of cells to biomaterials is a prerequisite for most biomedical applications; e.g., neuroelectrodes can only stimulate brain tissue in vivo if the electric signal is transferred to neurons attached to the electrodes' surface. Besides, cell survival in vitro also depends on the interaction of cells with the underlying substrate materials; in vitro assays such as multielectrode arrays determine cellular behavior by electrical coupling to the adherent cells. In our study, we investigated the interaction of neurons and glial cells with different electrode materials such as TiN and nanocolumnar TiN surfaces in contrast to gold and ITO substrates. Employing single-cell force spectroscopy, we quantified short-term interaction forces between neuron-like cells (SH-SY5Y cells) and glial cells (U-87 MG cells) for the different materials and contact times. Additionally, results were compared to the spreading dynamics of cells for different culture times as a function of the underlying substrate. The adhesion behavior of glial cells was almost independent of the biomaterial and the maximum growth areas were already seen after one day; however, adhesion dynamics of neurons relied on culture material and time. Neurons spread much better on TiN and nanocolumnar TiN and also formed more neurites after three days in culture. Our designed nanocolumnar TiN offers the possibility for building miniaturized microelectrode arrays for impedance spectroscopy without losing detection sensitivity due to a lowered self-impedance of the electrode. Hence, our results show that this biomaterial promotes adhesion and spreading of neurons and glial cells, which are important for many biomedical applications in vitro and in vivo.


Assuntos
Interfaces Cérebro-Computador , Neuroglia/efeitos dos fármacos , Neurônios/efeitos dos fármacos , Titânio/farmacologia , Citoesqueleto de Actina/efeitos dos fármacos , Citoesqueleto de Actina/metabolismo , Adesão Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Materiais Revestidos Biocompatíveis/química , Materiais Revestidos Biocompatíveis/farmacologia , Matriz Extracelular/química , Ouro/química , Ouro/farmacologia , Humanos , Teste de Materiais , Nanoestruturas/química , Neuritos/efeitos dos fármacos , Neuritos/fisiologia , Neuroglia/fisiologia , Neurônios/fisiologia , Compostos de Estanho/química , Compostos de Estanho/farmacologia , Titânio/química
2.
Int J Mol Sci ; 21(17)2020 Aug 28.
Artigo em Inglês | MEDLINE | ID: mdl-32872379

RESUMO

Biomaterials employed for neural stimulation, as well as brain/machine interfaces, offer great perspectives to combat neurodegenerative diseases, while application of lab-on-a-chip devices such as multielectrode arrays is a promising alternative to assess neural function in vitro. For bioelectronic monitoring, nanostructured microelectrodes are required, which exhibit an increased surface area where the detection sensitivity is not reduced by the self-impedance of the electrode. In our study, we investigated the interaction of neurons (SH-SY5Y) and glial cells (U-87 MG) with nanocolumnar titanium nitride (TiN) electrode materials in comparison to TiN with larger surface grains, gold, and indium tin oxide (ITO) substrates. Glial cells showed an enhanced proliferation on TiN materials; however, these cells spread evenly distributed over all the substrate surfaces. By contrast, neurons proliferated fastest on nanocolumnar TiN and formed large cell agglomerations. We implemented a radial autocorrelation function of cellular positions combined with various clustering algorithms. These combined analyses allowed us to quantify the largest cluster on nanocolumnar TiN; however, on ITO and gold, neurons spread more homogeneously across the substrates. As SH-SY5Y cells tend to grow in clusters under physiologic conditions, our study proves nanocolumnar TiN as a potential bioactive material candidate for the application of microelectrodes in contact with neurons. To this end, the employed K-means clustering algorithm together with radial autocorrelation analysis is a valuable tool to quantify cell-surface interaction and cell organization to evaluate biomaterials' performance in vitro.


Assuntos
Técnicas de Cultura de Células/métodos , Neuroglia/citologia , Neurônios/citologia , Titânio/química , Algoritmos , Linhagem Celular , Proliferação de Células , Ouro/química , Humanos , Nanoestruturas , Compostos de Estanho/química
3.
Nano Lett ; 18(10): 6375-6380, 2018 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-30203982

RESUMO

Here we present a novel electrically switchable nanovalve array based on an intrinsic conductive polymer that has the capabilities to change its volume depending on its redox state. The polymer is created by anodic deposition of a sodium dodecylbenzenesulfonate (DBS)-doped polypyrrole (PPy). Optimization of the DBS-doped PPy layers revealed an actuatoric performance of up to 10% out of plane volume change. More interestingly, the electrochemical characterization revealed an actuatoric monostable polymer that could be used to fabricate nanovalve arrays that have a native opened state when no potential is applied and that can be closed when a reductive potential is applied. As a proof of concept, Atto488-labeled biotin (Biotin-Atto488) was used as a model compound and defined nanovalve arrays with nanopores in the range of 10 nm in diameter (opened state) were fabricated. Afterward, we were able to successfully prove the functionality of our nanovalve array by monitoring the flow-through rates of the Biotin-Atto488. More strikingly, we could demonstrate for the first time the robust and long-term stability of our nanovalve array without any performance loss for at least 72 h and retention capabilities of up to 90%. Furthermore, the demonstrated long-term stability was achieved under biocompatible conditions without the need of toxic dopant supplementation of the flow-through solution. Thus, our novel functional long-term stable nanovalve array offers the capabilities for practical applications.

4.
Anal Chem ; 89(24): 13550-13558, 2017 12 19.
Artigo em Inglês | MEDLINE | ID: mdl-29164853

RESUMO

For miniaturization and integration of chemical synthesis and analytics on small length scales, the development of complex lab-on-chip (LOC) systems is in the focus of many current research projects. While application specific synthesis and analytic modules and LOC devices are widely described, the combination and integration of different modules is intensively investigated. Problems for in-line processes such as solvent incompatibilities, e.g., for a multistep synthesis or the combination of an organic drug synthesis with a cell-based biological activity testing system, require a solvent exchange between serialized modules. Here, we present a continuously operating microfluidic solvent exchanger based on the principle of free-flow electrophoresis for miscible organic/aqueous fluids. We highlight a proof-of-principle and describe the working principle for the model compound fluorescein, where the organic solvent DMSO is exchanged against an aqueous buffer. The DMSO removal performance could be significantly increased to 95% by optimization of the microfluidic layout. Moreover, the optimization of the inlet flow ratio resulted in a minimized dilution factor of 5, and we were able to demonstrate that a reduction of the supporting instrumentation is possible without a significant decrease of the DMSO removal performance. Finally, the compatibility of the developed solvent exchanger for cell based downstream applications was proven. The impedimetric monitoring of HEK293A cells in a continuously operating microfluidic setup revealed no adverse effects of the residual DMSO after the solvent replacement. Our solvent exchanger device demonstrates the power of micro-free-flow electrophoresis not only as a powerful technique for separation and purification of compound mixtures but also for solvent replacement.

5.
Analyst ; 142(11): 1929-1937, 2017 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-28484750

RESUMO

Due to the lack of appropriate cell models as well as automated electrophysiology monitoring technologies, the standardized identification of neurotoxic or protective effects in vitro remains a major problem in today's pharmaceutical ingredient development. Over the past few years, in vivo-like human pluripotent stem cell-derived neuronal networks have turned out to be a promising physiological cell source, if the establishment of robust and time-saving functional maturation strategies based on stable and expandable neural progenitor populations can be achieved. Here, we describe a multi-microelectrode array (MMEA)-based bioelectronics platform that was optimized for long-term electrophysiological activity monitoring of neuronal networks via field potential measurements. Differentiation of small molecule-based neuronal progenitors on MMEAs led to functional neurons within 15 days. More strikingly, these functional neuronal cultures could remain electrophysiologically stable on the MMEAs for more than four weeks. The observed electrophysiological properties correlated with the expression of typical neuron subtype markers and were further validated by specific neurotransmitter applications. With our established monitoring platform, we could show for the first time the long-term stability of the neural stem cell-like progenitor population to differentiate to electrophysiologically active dopaminergic neuronal networks for more than 80 passages. In conclusion, we provide a comprehensive long-term stable field potential monitoring platform based on stem cell-derived human neuronal networks that can be automated and up-scaled for standardized high-content screening applications e.g. in the field of neurotoxic and neuroprotective therapeutics identification.


Assuntos
Diferenciação Celular , Microeletrodos , Células-Tronco Neurais/citologia , Neurônios/citologia , Células Cultivadas , Fenômenos Eletrofisiológicos , Humanos
6.
Bioconjug Chem ; 27(4): 1090-7, 2016 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-26967204

RESUMO

Cytochrome P450 BM3 (CYP102A1) from Bacillus megaterium is an interesting target for biotechnological applications, because of its vast substrate variety combined with high P450 monooxygenase activity. The low stability in vitro could be overcome by immobilization on surfaces. Here we describe a novel method for immobilization on metal surfaces by using selectively binding peptides. A P450 BM3 triple mutant (3M-P450BM3: A74G, F87V, L188Q) was purified as protein thioester and ligated to indium tin oxide or gold binding peptides (BP) named HighSP-BP and Cys-BP, respectively. The ligation products were characterized by Western Blot and tryptic digestion combined with mass spectrometry, and displayed high affinity binding on the depicted surfaces. Next, we could demonstrate by benzyloxyresorufin O-dealkylation assay (BROD assay) that the activity of immobilized ligation products is higher than for the soluble form. The study provides a new tool for selective modification and immobilization of P450 variants.


Assuntos
Sistema Enzimático do Citocromo P-450/metabolismo , Enzimas Imobilizadas/metabolismo , Peptídeos/metabolismo , Catálise , Cromatografia Líquida de Alta Pressão , Eletroforese em Gel de Poliacrilamida , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz
7.
Anal Bioanal Chem ; 408(29): 8529-8538, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27722942

RESUMO

The analysis of receptor activity, especially in its native cellular environment, has always been of great interest to evaluate its intrinsic but also downstream biological activity. An important group of cellular receptors are ion channels. Since they are involved in a broad range of crucial cell functions, they represent important therapeutic targets. Thus, novel analytical techniques for the quantitative monitoring and screening of biological receptor activity are of great interest. In this context, we developed an impedance spectroscopy-based label-free and non-invasive monitoring system that enabled us to analyze the activation of the transient receptor potential channel Vanilloid 1 (TRPV1) in detail. TRPV1 channel activation by capsaicin resulted in a reproducible impedance decrease. Moreover, concentration response curves with an EC50 value of 0.9 µM could be determined. Control experiments with non TRPV1 channel expressing HEK cells as well as experiments with the TRPV1 channel blocker ruthenium red validated the specificity of the observed impedance decrease. More strikingly, through correlative studies with a cytoskeleton restructuring inhibitor mixture and equivalent circuit analysis of the acquired impedance spectra, we could quantitatively discriminate between the direct TRPV1 channel activation and downstream-induced biological effects. In summary, we developed a quantitative impedimetric monitoring system for the analysis of TRPV1 channel activity as well as downstream-induced biological activity in living cells. It has the capabilities to identify novel ion channel activators as well as inhibitors for the TRPV1 channel but could also easily be applied to other ion channel-based receptors.


Assuntos
Capsaicina/farmacologia , Espectroscopia Dielétrica/métodos , Canais de Cátion TRPV/metabolismo , Eletrodos , Células HEK293 , Humanos , Reprodutibilidade dos Testes , Rutênio Vermelho/farmacologia , Sensibilidade e Especificidade , Canais de Cátion TRPV/antagonistas & inibidores
8.
Adv Exp Med Biol ; 856: 259-297, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27671727

RESUMO

Quality control of cell cultures used in new in vitro toxicology assays is crucial to the provision of reliable, reproducible and accurate toxicity data on new drugs or constituents of new consumer products. This chapter explores the key scientific and ethical criteria that must be addressed at the earliest stages of developing toxicology assays based on human pluripotent stem cell (hPSC) lines. It also identifies key considerations for such assays to be acceptable for regulatory, laboratory safety and commercial purposes. Also addressed is the development of hPSC-based assays for the tissue and cell types of greatest interest in drug toxicology. The chapter draws on a range of expert opinion within the European Commission/Cosmetics Europe-funded alternative testing cluster SEURAT-1 and consensus from international groups delivering this guidance such as the International Stem Cell Banking Initiative. Accordingly, the chapter summarizes the most up-date best practices in the use and quality control of human Pluripotent Stem Cell lines in the development of in vitro toxicity assays from leading experts in the field.


Assuntos
Técnicas In Vitro/normas , Células-Tronco Pluripotentes/citologia , Testes de Toxicidade/métodos , Diferenciação Celular , Proliferação de Células , Humanos , Controle de Qualidade
9.
J Appl Toxicol ; 35(7): 861-9, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25351189

RESUMO

Di(2-ethylhexyl)phthalate (DEHP) is the most common plasticizer in plastic devices of everyday use. It is a ubiquitous environmental contaminant and primarily known to impair male gonadal development and fertility. Studies concerning the long-term effects of prenatal DEHP exposure on certain diseases [The Developmental Origins of Health and Disease paradigm (DOHaD) hypothesis] are scarce although it is proven that DEHP crosses the placenta. Rising environmental pollution during the last centuries coincides with an increasing prevalence of cardiovascular and metabolic diseases. We have investigated the effects of an early embryonic DEHP exposure at different developmental stages on cardiomyogenesis. We used an in-vitro model, the murine P19 embryonic carcinoma cell line (P19 ECC), mimicking early embryonic stages up to differentiated beating cardiomyocytes. P19 ECC were exposed to DEHP (5, 50, 100 µg ml(-1)) at the undifferentiated stage for 5 days and subsequently differentiated to beating cardiomyocytes. We analyzed the expression of metabolic (Pparg1, Fabp4 and Glut4), cardiac (Myh6, Gja1) and methylation (Dnmt1, Dnmt3a) marker genes by quantitative real-time PCR (qRT-PCR), beating rate and the differentiation velocity of the cells. The methylation status of Pparg1, Ppara and Glut4 was investigated by pyrosequencing. DEHP significantly altered the expression of all investigated genes. The beating rate and differentiation velocity were accelerated. Exposure to DEHP led to small but statistically significant increases in methylation of specific CpGs within Ppara and Pparg1, which otherwise were generally hypomethylated, but methylation of Glut4 was unaltered. Early DEHP exposure of P19 ECC alters the expression of genes associated with cellular metabolism and the functional features of cardiomyocytes.


Assuntos
Dietilexilftalato/efeitos adversos , Miócitos Cardíacos/efeitos dos fármacos , Animais , Diferenciação Celular/efeitos dos fármacos , Linhagem Celular Tumoral , DNA (Citosina-5-)-Metiltransferase 1 , DNA (Citosina-5-)-Metiltransferases/metabolismo , Metilação de DNA/efeitos dos fármacos , DNA Metiltransferase 3A , Relação Dose-Resposta a Droga , Regulação da Expressão Gênica no Desenvolvimento/efeitos dos fármacos , Marcadores Genéticos/efeitos dos fármacos , Camundongos , Contração Miocárdica/efeitos dos fármacos , Miócitos Cardíacos/metabolismo , Reação em Cadeia da Polimerase em Tempo Real
10.
Biosens Bioelectron ; 250: 116042, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38266619

RESUMO

Three-dimensional (3D) in vitro cell culture models serve as valuable tools for accurately replicating cellular microenvironments found in vivo. While cell culture technologies are rapidly advancing, the availability of non-invasive, real-time, and label-free analysis methods for 3D cultures remains limited. To meet the demand for higher-throughput drug screening, there is a demanding need for analytical methods that can operate in parallel. Microelectrode systems in combination with microcavity arrays (MCAs), offer the capability of spatially resolved electrochemical impedance analysis and field potential monitoring of 3D cultures. However, the fabrication and handling of small-scale MCAs have been labour-intensive, limiting their broader application. To overcome this challenge, we have established a process for creating MCAs in a standard 96-well plate format using high-precision selective laser etching. In addition, to automate and ensure the accurate placement of 3D cultures on the MCA, we have designed and characterized a plug-in tool using SLA-3D-printing. To characterize our new 96-well plate MCA-based platform, we conducted parallel analyses of human melanoma 3D cultures and monitored the effect of cisplatin in real-time by impedance spectroscopy. In the following we demonstrate the capabilities of the MCA approach by analysing contraction rates of human pluripotent stem cell-derived cardiomyocyte aggregates in response to cardioactive compounds. In summary, our MCA system significantly expands the possibilities for label-free analysis of 3D cell and tissue cultures, offering an order of magnitude higher parallelization capacity than previous devices. This advancement greatly enhances its applicability in real-world settings, such as drug development or clinical diagnostics.


Assuntos
Técnicas Biossensoriais , Humanos , Miócitos Cardíacos , Técnicas de Cultura de Células/métodos , Técnicas de Cultura de Células em Três Dimensões , Espectroscopia Dielétrica
11.
Sci Rep ; 14(1): 3596, 2024 02 13.
Artigo em Inglês | MEDLINE | ID: mdl-38351286

RESUMO

Abuse of amphetamine-type stimulants is linked to cardiovascular adverse effects like arrhythmias, accelerated atherosclerosis, acute coronary syndromes and sudden cardiac death. Excessive catecholamine release following amphetamine use causes vasoconstriction and vasospasms, over time leading to hypertension, endothelial dysfunction or even cardiotoxicity. However, immediate vascular pathomechanisms related to amphetamine exposure, especially endothelial function, remain incompletely understood and were analyzed in this study. Pharmaco-pathological effects of acute d-amphetamine-sulfate (DAM) were investigated ex vivo using contraction-force measurements of rat carotid artery rings and in vitro using label-free, real-time electrochemical impedance spectroscopy (EIS) on endothelial and smooth muscle cells. Specific receptor and target blocking was used to identify molecular targets and to characterize intracellular signaling. DAM induced vasodilation represented by 29.3±2.5% decrease in vascular tone (p<0.001) involving vascular endothelial growth factor receptor (VEGF-R) and protease activated receptor 1 (PAR-1). EIS revealed that DAM induces endothelial barrier disruption (-75.9±1.1% of initial cellular impedance, p<0.001) also involving VEGF-R and PAR-1. Further, in response to DAM, Rho-associated protein kinase (ROCK) mediated reversible contraction of actin cytoskeleton resulting in endothelial barrier disruption. Dephosphorylation of Serine1177 (-50.8±3.7%, p<0.001) and Threonine495 (-44.8±6.5%, p=0.0103) of the endothelial NO synthase (eNOS) were also observed. Blocking of VEGF-R and PAR-1 restored baseline eNOS Threonine495 phosphorylation. DAM induced vasodilation, enhanced vascular permeability and actin cytoskeleton contraction and induced eNOS hypophosphorylation involving VEGF-R, PAR-1 and ROCK. These results may contribute to a better understanding of severe adverse cardiovascular effects in amphetamine abuse.


Assuntos
Receptor PAR-1 , Doenças Vasculares , Ratos , Animais , Receptor PAR-1/metabolismo , Fator A de Crescimento do Endotélio Vascular/metabolismo , Anfetamina/farmacologia , Permeabilidade Capilar , Óxido Nítrico Sintase/metabolismo , Óxido Nítrico Sintase Tipo III/metabolismo , Quinases Associadas a rho/metabolismo , Doenças Vasculares/metabolismo , Endotélio Vascular/metabolismo , Citoesqueleto de Actina/metabolismo , Células Cultivadas
12.
Biosensors (Basel) ; 14(6)2024 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-38920600

RESUMO

Development and optimisation of bioelectronic monitoring techniques like microelectrode array-based field potential measurement and impedance spectroscopy for the functional, label-free and non-invasive monitoring of in vitro neuronal networks is widely investigated in the field of biosensors. Thus, these techniques were individually used to demonstrate the capabilities of, e.g., detecting compound-induced toxicity in neuronal culture models. In contrast, extended application for investigating the effects of central nervous system infecting viruses are rarely described. In this context, we wanted to analyse the effect of herpesviruses on functional neuronal networks. Therefore, we developed a unique hybrid bioelectronic monitoring platform that allows for performing field potential monitoring and impedance spectroscopy on the same microelectrode. In the first step, a neuronal culture model based on primary hippocampal cells from neonatal rats was established with reproducible and stable synchronised electrophysiological network activity after 21 days of cultivation on microelectrode arrays. For a proof of concept, the pseudorabies model virus PrV Kaplan-ΔgG-GFP was applied and the effect on the neuronal networks was monitored by impedance spectroscopy and field potential measurement for 72 h in a multiparametric mode. Analysis of several bioelectronic parameters revealed a virus concentration-dependent degeneration of the neuronal network within 24-48 h, with a significant early change in electrophysiological activity, subsequently leading to a loss of activity and network synchronicity. In conclusion, we successfully developed a microelectrode array-based hybrid bioelectronic measurement platform for quantitative monitoring of pathologic effects of a herpesvirus on electrophysiological active neuronal networks.


Assuntos
Técnicas Biossensoriais , Espectroscopia Dielétrica , Neurônios , Animais , Ratos , Neurônios/virologia , Rede Nervosa , Microeletrodos , Hipocampo/virologia , Herpesvirus Suídeo 1 , Células Cultivadas , Pseudorraiva/virologia
13.
Biosens Bioelectron ; 252: 116120, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38394704

RESUMO

In recent decades, significant progress has been made in the treatment of heart diseases, particularly in the field of personalized medicine. Despite the development of genetic tests, phenotyping and risk stratification are performed based on clinical findings and invasive in vivo techniques, such as stimulation conduction mapping techniques and programmed ventricular pacing. Consequently, label-free non-invasive in vitro functional analysis systems are urgently needed for more accurate and effective in vitro risk stratification, model-based therapy planning, and clinical safety profile evaluation of drugs. To overcome these limitations, a novel multilayer high-density microelectrode array (HD-MEA), with an optimized configuration of 512 sensing and 4 pacing electrodes on a sensor area of 100 mm2, was developed for the bioelectronic detection of re-entry arrhythmia patterns. Together with a co-developed front-end, we monitored label-free and in parallel cardiac electrophysiology based on field potential monitoring and mechanical contraction using impedance spectroscopy at the same microelectrode. In proof of principle experiments, human induced pluripotent stem cell (hiPS)-derived cardiomyocytes were cultured on HD-MEAs and used to demonstrate the sensitive quantification of contraction strength modulation by cardioactive drugs such as blebbistatin (IC50 = 4.2 µM), omecamtiv and levosimendan. Strikingly, arrhythmia-typical rotor patterns (re-entry) can be induced by optimized electrical stimulation sequences and detected with high spatial resolution. Therefore, we provide a novel cardiac re-entry analysis system as a promising reference point for diagnostic approaches based on in vitro assays using patient-specific hiPS-derived cardiomyocytes.


Assuntos
Técnicas Biossensoriais , Células-Tronco Pluripotentes Induzidas , Humanos , Microeletrodos , Arritmias Cardíacas/diagnóstico , Miócitos Cardíacos/fisiologia
14.
Biosens Bioelectron ; 202: 114010, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35081486

RESUMO

Three-dimensional cell models represent the native in vivo situation more closely than two-dimensional cultures and are therefore preferred today for in vitro studies. In this context, there is a great demand for fast, non-invasive, real-time, and label-free methods that are capable for detailed analyses of three-dimensional cultures. To characterize heterogeneous cultures or to detect localized drug effects, a measurement method such as impedance spectroscopy in combination with microcavity arrays (MCAs) is desirable, which additionally offers spatial resolution. To overcome these limitations of the previously described MCA based on opaque silicon substrates and a square shape with four measurement electrodes imposed by the crystal structure, we used the selective laser etching (SLE) method to fabricate microcavities in fused silica and borosilicate glass without geometric constraints. We successfully developed MCAs with variable base including up to eight measurement electrodes in one cavity, which allows the increase in the number of electrode combinations to improve spatial resolution. In addition, we integrated a central cone electrode at the cavity bottom to extend the spatial resolution on the z-axis. To demonstrate the capability of the MCAs, we used MDA-HB-231 spheroids with an enclosed glass sphere to show that the heterogeneity of the model is evident in the relative impedance spectra. Analyses on various cell spheroids highlight the broad applicability of glass MCAs. In conclusion, our SLE-fabricated MCA clearly improve bioelectronic analyses of cellular changes in heterogeneous 3D models. Thus, bioelectronic analysis of electrophysiologically active cells and tumor biopsy samples could significantly benefit from our development.


Assuntos
Técnicas Biossensoriais , Técnicas Biossensoriais/métodos , Espectroscopia Dielétrica , Impedância Elétrica , Eletrodos , Esferoides Celulares
15.
Biosens Bioelectron ; 202: 114012, 2022 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-35081487

RESUMO

Microelectrode arrays (MEA) are widely used for bioelectronic monitoring of alterations in cells and tissues. MEAs are based on a substrate that is structured with electrodes and conducting paths. While cheap substrates like printed circuit board materials offers easy production and flexible contacting, there are limitations regarding microstructure resolution, optical transparency and biocompatibility. In contrast, glass substrates are favored due to its biocompatibility, chemical resistance and optical transparency. Drawbacks are high substrate costs and limited flexibility for routing of conducting paths. To overcome these limitations, we wanted to use optical transparent polymer-based substrates. Therefore, we identified the polymer poly-methyl-methacrylate (PMMA) as a promising substrate material, due to its good optical and mechanical properties as well as biocompatibility. To achieve sufficient chemical resistance for high resolution photolithographic structuring a novel process had to be developed involving a protection coating. After optimization of the structuring process, we achieved a comparable resolution and thus, microelectrodes with diameter of less than 100 µm. Moreover, the use of PMMA allowed the simple integration of more than 400 vias directly into the substrate for contacting of the microelectrode array from the bottom without the need of complex and error prone redirecting adapters with hundreds of additional bonding sides. In order to show that the PMMA based MEA is comparable to glass based MEA in terms of signal quality and sensitivity as well as optical and surface properties, we cultivated different cell models on the MEAs and validated our 96-well PMMA MEAs by different bioelectronic monitoring techniques.


Assuntos
Técnicas Biossensoriais , Polímeros , Microeletrodos , Polímeros/química , Polimetil Metacrilato , Propriedades de Superfície
16.
Biomater Sci ; 10(19): 5719-5730, 2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36039696

RESUMO

Lab-on-a-chip devices, such as multielectrode arrays (MEAs), offer great advantages to study function and behavior of biological cells, such as neurons, outside the complex tissue structure. Nevertheless, in vitro systems can only succeed if they represent realistic conditions such as cell organization as similarly found in tissues. In our study, we employ a co-culture system of neuron-like (SH-SY5Y) and glial-like (U-87 MG) cells with various neuron-glial ratios to model different brain regions with different cellular compositions in vitro. We find that cell behavior in terms of cellular organization, as well as proliferation, depends on neuron-glial cell ratio, as well as the underlying substrate material. In fact, nanocolumnar titanium nitride (TiN nano), which exhibits improved electric properties for neural recording on MEA, shows improved biocompatible features compared to indium tin oxide (ITO). Moreover, electrochemical impedance spectroscopy experiments allow us to monitor cellular processes label-free in real-time over several days with multielectrode arrays. Additionally, electrochemical impedance experiments reveal superiority of TiN with nanocolumnar surface modification in comparison with ITO. TiN nano exhibits enhanced relative cell signals and improved signal-to-noise ratio, especially for smaller electrode sizes, which makes nanocolumnar TiN a promising candidate for research on neural recording and stimulation.


Assuntos
Espectroscopia Dielétrica , Neuroblastoma , Humanos , Técnicas de Cocultura , Dispositivos Lab-On-A-Chip , Neuroglia , Neurônios/fisiologia
17.
ACS Sens ; 7(12): 3906-3914, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-36512685

RESUMO

Miniaturization and integration of chemical reactions into fluidic systems in combination with product purification or buffer exchange can reduce the amount of solvents and reactants required while increasing synthesis efficiency. A critical step is the regulation of flow rates to realize optimal synthesis conditions and high purification rates, so real-time, label-free monitoring is required in methods such as free-flow electrophoresis. Optical detection methods are widely used, but they often have complex excitation and detection setups that are disadvantageous for point-of-care applications. The method we have chosen is electrochemical impedance spectroscopy for detecting charged compounds in aqueous buffers with low ionic strength. Propranolol was selected for proof of concept and was separated from the organic solvent and the precursor oxirane by free-flow electrophoresis. For this purpose, electrode structures were fabricated in microfluidic channels by photolithographic lift-off technique and optimized in terms of positioning, electrode size and distance for sensitive detection, and quantification of propranolol in the nanomolar range. It is also noteworthy that the organic solvent dimethyl sulfoxide (DMSO) could be detected and quantified by an increased impedance magnitude. Subsequently, the optimized interdigital electrode structures were integrated into the outlet channels of the electrophoretic separation chamber to monitor the various outgoing fluidic streams and provide in-line control of the fluidic flows for the purification step. In conclusion, we can provide a microfluidic chip to monitor the separation efficiency of a substance mixture during free-flow electrophoresis without the need of complex analytical techniques using electrochemical impedance spectroscopy.


Assuntos
Técnicas Analíticas Microfluídicas , Técnicas Analíticas Microfluídicas/métodos , Espectroscopia Dielétrica , Propranolol , Eletroforese , Eletrodos
18.
J Invest Dermatol ; 142(12): 3282-3293, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35691363

RESUMO

Epidermolysis bullosa simplex (EBS) is a severe and potentially life-threatening disorder for which no adequate therapy exists. Most cases are caused by dominant sequence variations in keratin genes K5 or K14, leading to the formation of cytoplasmic keratin aggregates, profound keratinocyte fragility, and cytolysis. We hypothesized that pharmacological reduction of keratin aggregates, which compromise keratinocyte integrity, represents a viable strategy for the treatment of EBS. In this study, we show that the multikinase inhibitor PKC412, which is currently in clinical use for acute myeloid leukemia and advanced systemic mastocytosis, reduced keratin aggregation by 40% in patient-derived K14.R125C EBS-associated keratinocytes. Using a combination of epithelial shear stress assay and real-time impedance spectroscopy, we show that PKC412 restored intercellular adhesion. Molecularly, global phosphoproteomic analysis together with immunoblots using phosphoepitope-specific antibodies revealed that PKC412 treatment altered phosphorylated sites on keratins and desmoplakin. Thus, our data provide a proof of concept to repurpose existing drugs for the targeted treatment of EBS and showcase how one broad-range kinase inhibitor reduced keratin filament aggregation in patient-derived EBS keratinocytes and the fragility of EBS cell monolayers. Our study paves the way for a clinical trial using PKC412 for systemic or local application in patients with EBS.


Assuntos
Epidermólise Bolhosa Simples , Humanos , Epidermólise Bolhosa Simples/genética , Epidermólise Bolhosa Simples/metabolismo , Queratinas/metabolismo , Estaurosporina/metabolismo , Citoesqueleto/metabolismo , Proteínas do Citoesqueleto/genética , Queratina-14/genética , Queratina-14/metabolismo , Queratina-5/genética , Queratina-5/metabolismo , Mutação
19.
ChemSusChem ; 15(9): e202101062, 2022 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-34129279

RESUMO

Earth is flooded with plastics and the need for sustainable recycling strategies for polymers has become increasingly urgent. Enzyme-based hydrolysis of post-consumer plastic is an emerging strategy for closed-loop recycling of polyethylene terephthalate (PET). The polyester hydrolase PHL7, isolated from a compost metagenome, completely hydrolyzes amorphous PET films, releasing 91 mg of terephthalic acid per hour and mg of enzyme. Vertical scanning interferometry shows degradation rates of the PET film of 6.8 µm h-1 . Structural analysis indicates the importance of leucine at position 210 for the extraordinarily high PET-hydrolyzing activity of PHL7. Within 24 h, 0.6 mgenzyme gPET -1 completely degrades post-consumer thermoform PET packaging in an aqueous buffer at 70 °C without any energy-intensive pretreatments. Terephthalic acid recovered from the enzymatic hydrolysate is then used to synthesize virgin PET, demonstrating the potential of polyester hydrolases as catalysts in sustainable PET recycling processes with a low carbon footprint.


Assuntos
Hidrolases , Polietilenotereftalatos , Pegada de Carbono , Hidrolases/metabolismo , Metagenoma , Plásticos/química , Polietilenotereftalatos/química , Reciclagem
20.
Front Bioeng Biotechnol ; 9: 821734, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35242754

RESUMO

Microbial resource mining of electroactive microorganism (EAM) is currently methodically hampered due to unavailable electrochemical screening tools. Here, we introduce an electrochemical microwell plate (ec-MP) composed of a 96 electrochemical deepwell plate and a recently developed 96-channel multipotentiostat. Using the ec-MP we investigated the electrochemical and metabolic properties of the EAM models Shewanella oneidensis and Geobacter sulfurreducens with acetate and lactate as electron donor combined with an individual genetic analysis of each well. Electrochemical cultivation of pure cultures achieved maximum current densities (j max) and coulombic efficiencies (CE) that were well in line with literature data. The co-cultivation of S. oneidensis and G. sulfurreducens led to an increased current density of j max of 88.57 ± 14.04 µA cm-2 (lactate) and j max of 99.36 ± 19.12 µA cm-2 (lactate and acetate). Further, a decreased time period of reaching j max and biphasic current production was revealed and the microbial electrochemical performance could be linked to the shift in the relative abundance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA