Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 96
Filtrar
1.
Osteoarthritis Cartilage ; 29(1): 124-133, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33166667

RESUMO

OBJECTIVE: For many proteins from osteoarthritic synovial fluid, their intra-articular tissue of origin remains unknown. In this study we performed comparative proteomics to identify osteoarthritis-specific and joint tissue-dependent secreted proteins that may serve as candidates for osteoarthritis biomarker development on a tissue-specific basis. DESIGN: Protein secretomes of cartilage, synovium, Hoffa's fat pad and meniscus from knee osteoarthritis patients were determined using liquid chromatography tandem mass spectrometry, followed by label-free quantification. Validation of tissue-dependent protein species was conducted by ELISA on independent samples. Differential proteomes of osteoarthritic and non-osteoarthritic knee synovial fluids were obtained via similar proteomics approach, followed by ELISA validation. RESULTS: Proteomics revealed 64 proteins highly secreted from cartilage, 94 from synovium, 37 from Hoffa's fat pad and 21 from meniscus. Proteomic analyses of osteoarthritic vs non-osteoarthritic knee synovial fluid revealed 70 proteins with a relatively higher abundance and 264 proteins with a relatively lower abundance in osteoarthritic synovial fluid. Of the 70 higher abundance proteins, 23 were amongst the most highly expressed in the secretomes of a specific intra-articular tissue measured. Tissue-dependent release was validated for SLPI, C8, CLU, FN1, RARRES2, MATN3, MMP3 and TNC. Abundance in synovial fluid of tissue-dependent proteins was validated for IGF2, AHSG, FN1, CFB, KNG and C8. CONCLUSIONS: We identified proteins with a tissue-dependent release from intra-articular human knee OA tissues. A number of these proteins also had an osteoarthritis-specific abundance in knee synovial fluid. These proteins may serve as novel candidates for osteoarthritis biomarker development on a tissue-specific basis.


Assuntos
Tecido Adiposo/metabolismo , Cartilagem Articular/metabolismo , Meniscos Tibiais/metabolismo , Osteoartrite do Joelho/metabolismo , Proteômica , Líquido Sinovial/metabolismo , Membrana Sinovial/metabolismo , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Articulação do Joelho/metabolismo , Masculino , Secretoma
2.
Osteoarthritis Cartilage ; 26(2): 236-244, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29175373

RESUMO

OBJECTIVE: To define the physiological response to sequential loading and unloading in histologically intact human articular cartilage using serial T1ρ mapping, as T1ρ is considered to indicate the tissue's macromolecular content. METHOD: 18 macroscopically intact cartilage-bone samples were obtained from the central lateral femoral condyles of 18 patients undergoing total knee replacement. Serial T1ρ mapping was performed on a clinical 3.0-T MRI system using a modified prostate coil. Spin-lock multiple gradient-echo sequences prior to, during and after standardized indentation loading (displacement controlled, strain 20%) were used to obtain seven serial T1ρ maps: unloaded (δ0), quasi-statically loaded (indentation1-indentation3) and under subsequent relaxation (relaxation1-relaxation3). After manual segmentation, zonal and regional regions-of-interest were defined. ROI-specific relative changes were calculated and statistically assessed using paired t-tests. Histological (Mankin classification) and biomechanical (unconfined compression) evaluations served as references. RESULTS: All samples were histologically and biomechanically grossly intact (Mankin sum: 1.8 ± 1.2; Young's Modulus: 0.7 ± 0.4 MPa). Upon loading, T1ρ consistently increased throughout the entire sample thickness, primarily subpistonally (indentation1 [M ± SD]: 9.5 ± 7.8% [sub-pistonal area, SPA] vs 4.2 ± 5.8% [peri-pistonal area, PPA]; P < 0.001). T1ρ further increased with ongoing loading (indentation3: 14.1 ± 8.1 [SPA] vs 7.7 ± 5.9% [PPA]; P < 0.001). Even upon unloading (i.e., relaxation), T1ρ persistently increased in time. CONCLUSION: Serial T1ρ-mapping reveals distinct and complex zonal and regional changes in articular cartilage as a function of loading and unloading. Thereby, longitudinal adaptive processes in hyaline cartilage become evident, which may be used for the tissue's non-invasive functional characterization by T1ρ.


Assuntos
Cartilagem Articular/fisiopatologia , Articulação do Joelho/fisiopatologia , Suporte de Carga/fisiologia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho , Fenômenos Biomecânicos , Cartilagem Articular/diagnóstico por imagem , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade
3.
Eur Cell Mater ; 29: 141-53; discussion 153-4, 2015 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-25738583

RESUMO

Regeneration of load-bearing segmental bone defects is a major challenge in trauma and orthopaedic surgery. The ideal bone graft substitute is a biomaterial that provides immediate mechanical stability, while stimulating bone regeneration to completely bridge defects over a short period. Therefore, selective laser melted porous titanium, designed and fine-tuned to tolerate full load-bearing, was filled with a physiologically concentrated fibrin gel loaded with bone morphogenetic protein-2 (BMP-2). This biomaterial was used to graft critical-sized segmental femoral bone defects in rats. As a control, porous titanium implants were either left empty or filled with a fibrin gels without BMP-2. We evaluated bone regeneration, bone quality and mechanical strength of grafted femora using in vivo and ex vivo µCT scanning, histology, and torsion testing. This biomaterial completely regenerated and bridged the critical-sized bone defects within eight weeks. After twelve weeks, femora were anatomically re-shaped and revealed open medullary cavities. More importantly, new bone was formed throughout the entire porous titanium implants and grafted femora regained more than their innate mechanical stability: torsional strength exceeded twice their original strength. In conclusion, combining porous titanium implants with a physiologically concentrated fibrin gels loaded with BMP-2 improved bone regeneration in load-bearing segmental defects. This material combination now awaits its evaluation in larger animal models to show its suitability for grafting load-bearing defects in trauma and orthopaedic surgery.


Assuntos
Proteína Morfogenética Óssea 2/farmacologia , Fibrina/farmacologia , Fraturas Ósseas/terapia , Próteses e Implantes , Titânio , Animais , Fenômenos Biomecânicos , Regeneração Óssea , Substitutos Ósseos/farmacologia , Fêmur/efeitos dos fármacos , Fêmur/lesões , Fêmur/cirurgia , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/fisiopatologia , Géis , Masculino , Microscopia Eletrônica de Varredura , Porosidade , Ratos Wistar , Suporte de Carga , Microtomografia por Raio-X
4.
Osteoarthritis Cartilage ; 22(4): 591-600, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24561282

RESUMO

OBJECTIVE: Osteoarthritis (OA) is a non-rheumatologic joint disease characterized by progressive degeneration of the cartilage extra-cellular matrix (ECM), enhanced subchondral bone remodeling, activation of synovial macrophages and osteophyte growth. Inhibition of calcineurin (Cn) activity through tacrolimus (FK506) in in vitro monolayer chondrocytes exerts positive effects on ECM marker expression. This study therefore investigated the effects of FK506 on anabolic and catabolic markers of osteoarthritic chondrocytes in 2D and 3D in vitro cultures, and its therapeutic effects in an in vivo rat model of OA. METHODS: Effects of high and low doses of FK506 on anabolic (QPCR/histochemistry) and catabolic (QPCR) markers were evaluated in vitro on isolated (2D) and ECM-embedded chondrocytes (explants, 3D pellets). Severe cartilage damage was induced unilaterally in rat knees using papain injections in combination with a moderate running protocol. Twenty rats were treated with FK506 orally and compared to twenty untreated controls. Subchondral cortical and trabecular bone changes (longitudinal microCT) and macrophage activation (SPECT/CT) were measured. Articular cartilage was analyzed ex vivo using contrast enhanced microCT and histology. RESULTS: FK506 treatment of osteoarthritic chondrocytes in vitro induced anabolic (mainly collagens) and reduced catabolic ECM marker expression. In line with this, FK506 treatment clearly protected ECM integrity in vivo by markedly decreasing subchondral sclerosis, less development of subchondral pores, depletion of synovial macrophage activation and lower osteophyte growth. CONCLUSION: FK506 protected cartilage matrix integrity in vitro and in vivo. Additionally, FK506 treatment in vivo reduced OA-like responses in different articular joint tissues and thereby makes Cn an interesting target for therapeutic intervention of OA.


Assuntos
Inibidores de Calcineurina/farmacologia , Cartilagem Articular/efeitos dos fármacos , Condrócitos/efeitos dos fármacos , Osteoartrite do Joelho/tratamento farmacológico , Tacrolimo/farmacologia , Animais , Cartilagem Articular/diagnóstico por imagem , Estudos de Casos e Controles , Condrócitos/diagnóstico por imagem , Meios de Contraste , Modelos Animais de Doenças , Humanos , Macrófagos/diagnóstico por imagem , Macrófagos/efeitos dos fármacos , Masculino , Osteoartrite do Joelho/patologia , Ratos , Ratos Wistar , Joelho de Quadrúpedes/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Resultado do Tratamento , Microtomografia por Raio-X/métodos
5.
Eur Cell Mater ; 27: 137-48; discussion 148, 2014 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-24554271

RESUMO

Grafting bone defects or atrophic non-unions with mesenchymal stromal cells (MSCs)-based grafts is not yet successful. MSC-based grafts typically use undifferentiated or osteogenically differentiated MSCs and regenerate bone through intramembranous ossification. Endochondral ossification might be more potent but requires chondrogenic differentiation of MSCs. Here, we determined if chondrogenically differentiated MSC (ch-MSC) pellets could induce bone regeneration in an orthotopic environment through endochondral ossification. Undifferentiated MSC pellets (ud-MSC) and ch-MSC pellets were generated from MSCs of human donors cultured on chondrogenic medium for respectively 3 (ud-MSC) and 21 (ch-MSC) days. A 6 mm femoral bone defect was made and stabilised with an internal plate in 27 athymic rats. Defects were left empty for 6 weeks to develop an atrophic non-union before they were grafted with ch-MSC pellets or ud-MSC pellets. Micro-CT scans made 4 and 8 weeks after grafting showed that ch-MSC pellets resulted in significantly more bone than ud-MSC pellets. This regenerated bone could completely bridge the defect, but the amount of bone regeneration was donor-dependent. Histology after 7 and 14 days showed slowly mineralising pellets containing hypertrophic chondrocytes, as well as TRAP-positive and CD34-positive cells around the ch-MSC pellets, indicating osteoclastic resorption and vascularisation typical for endochondral ossification. In conclusion, grafting critical femoral bone defects with chondrogenically differentiated MSC pellets led to rapid and pronounced bone regeneration through endochondral ossification and may therefore be a more successful MSC-based graft to repair large bone defects or atrophic non-unions. But, since bone regeneration was donor-depend, the generation of potent chondrogenically differentiated MSC pellets for each single donor needs to be established first.


Assuntos
Regeneração Óssea , Condrogênese , Células-Tronco Mesenquimais/citologia , Osteogênese , Idoso , Animais , Feminino , Fêmur/fisiologia , Fêmur/cirurgia , Humanos , Masculino , Transplante de Células-Tronco Mesenquimais , Pessoa de Meia-Idade , Ratos
6.
Orthopade ; 43(4): 298-305, 2014 Apr.
Artigo em Alemão | MEDLINE | ID: mdl-24671345

RESUMO

BACKGROUND: Fracture healing is a complex biological process with specific temporal expression patterns. During this process new bone tissue is formed, which is similar to the original bone in quality and structure. This occurs in four phases: inflammation, formation of a soft tissue callus, formation of a bony callus and remodelling of the bony callus. This needs the precise orchestration of each cell type involved. OBJECTIVES: This article presents details of the fracture healing phases and the relevant factors. During the aging process there is an increase of reactive oxygen species and a change in expression pattern of growth factors that have a negative effect on the fracture healing process. METHODS: A selective review of the literature was carried out in PubMed concerning the influence of aging on fracture healing. CONCLUSION: The healing process is regulated by systemic and local factors. An understanding of these processes and the changes during aging is necessary in order to improve the knowledge of delayed or lack of fracture healing during aging to decide when an intervention is needed.


Assuntos
Envelhecimento/metabolismo , Remodelação Óssea/fisiologia , Consolidação da Fratura/fisiologia , Fraturas Ósseas/fisiopatologia , Fraturas Ósseas/terapia , Peptídeos e Proteínas de Sinalização Intercelular/metabolismo , Espécies Reativas de Oxigênio/metabolismo , Feminino , Humanos , Modelos Biológicos , Estresse Oxidativo
7.
Acta Biomater ; 169: 589-604, 2023 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-37536493

RESUMO

Additively manufactured (AM) degradable porous metallic biomaterials offer unique opportunities for satisfying the design requirements of an ideal bone substitute. Among the currently available biodegradable metals, iron has the highest elastic modulus, meaning that it would benefit the most from porous design. Given the successful preclinical applications of such biomaterials for the treatment of cardiovascular diseases, the moderate compatibility of AM porous iron with osteoblast-like cells, reported in earlier studies, has been surprising. This may be because, as opposed to static in vitro conditions, the biodegradation products of iron in vivo are transported away and excreted. To better mimic the in situ situations of biodegradable biomaterials after implantation, we compared the biodegradation behavior and cytocompatibility of AM porous iron under static conditions to the conditions with dynamic in situ-like fluid flow perfusion in a bioreactor. Furthermore, the compatibility of these scaffolds with four different cell types was evaluated to better understand the implications of these implants for the complex process of natural wound healing. These included endothelial cells, L929 fibroblasts, RAW264.7 macrophage-like cells, and osteoblastic MG-63 cells. The biodegradation rate of the scaffolds was significantly increased in the perfusion bioreactor as compared to static immersion. Under either condition, the compatibility with L929 cells was the best. Moreover, the compatibility with all the cell types was much enhanced under physiomimetic dynamic flow conditions as compared to static biodegradation. Our study highlights the importance of physiomimetic culture conditions and cell type selection when evaluating the cytocompatibility of degradable biomaterials in vitro. STATEMENT OF SIGNIFICANCE: Additively manufactured (AM) degradable porous metals offer unique opportunities for the treatment of large bony defects. Despite the successful preclinical applications of biodegradable iron in the cardiovascular field, the moderate compatibility of AM porous iron with osteoblast-like cells was reported. To better mimic the in vivo condition, we compared the biodegradation behavior and cytocompatibility of AM porous iron under static condition to dynamic perfusion. Furthermore, the compatibility of these scaffolds with various cell types was evaluated to better simulate the process of natural wound healing. Our study suggests that AM porous iron holds great promise for orthopedic applications, while also highlighting the importance of physio-mimetic culture conditions and cell type selection when evaluating the cytocompatibility of degradable biomaterials in vitro.


Assuntos
Células Endoteliais , Ferro , Ferro/farmacologia , Porosidade , Materiais Biocompatíveis/farmacologia , Metais
8.
Acta Biomater ; 101: 609-623, 2020 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-31672587

RESUMO

Additively manufacturing (AM) opens up the possibility for biodegradable metals to possess uniquely combined characteristics that are desired for bone substitution, including bone-mimicking mechanical properties, topologically ordered porous structure, pore interconnectivity and biodegradability. Zinc is considered to be one of the promising biomaterials with respect to biodegradation rate and biocompatibility. However, no information regarding the biodegradability and biocompatibility of topologically ordered AM porous zinc is yet available. Here, we applied powder bed fusion to fabricate porous zinc with a topologically ordered diamond structure. An integrative study was conducted on the static and dynamic biodegradation behavior (in vitro, up to 4 weeks), evolution of mechanical properties with increasing immersion time, electrochemical performance, and biocompatibility of the AM porous zinc. The specimens lost 7.8% of their weight after 4 weeks of dynamic immersion in a revised simulated body fluid. The mechanisms of biodegradation were site-dependent and differed from the top of the specimens to the bottom. During the whole in vitro immersion time of 4 weeks, the elastic modulus values of the AM porous zinc (E = 700-1000 MPa) even increased and remained within the scope of those of cancellous bone. Indirect cytotoxicity revealed good cellular activity up to 72 h according to ISO 10,993-5 and -12. Live-dead staining confirmed good viability of MG-63 cells cultured on the surface of the AM porous zinc. These important findings could open up unprecedented opportunities for the development of multifunctional bone substituting materials that will enable reconstruction and regeneration of critical-size load-bearing bone defects. STATEMENT OF SIGNIFICANCE: No information regarding the biodegradability and biocompatibility of topologically ordered AM porous zinc is available. We applied selective laser melting to fabricate topologically ordered porous zinc and conducted a comprehensive study on the biodegradation behavior, electrochemical performance, time-dependent mechanical properties, and biocompatibility of the scaffolds. The specimens lost 7.8% of their weight after4 weeks dynamic biodegradation while their mechanical properties surprisingly increased after 4 weeks. Indirect cytotoxicity revealed good cellular activity up to 72 h. Intimate contact between MG-63 cells and the scaffolds was also observed. These important findings could open up unprecedented opportunities for the development of multifunctional bone substituting materials that mimic bone properties and enable full regeneration of critical-size load-bearing bony defects.


Assuntos
Materiais Biocompatíveis/síntese química , Zinco/química , Morte Celular , Linhagem Celular , Espectroscopia Dielétrica , Humanos , Espectroscopia Fotoeletrônica , Porosidade , Propriedades de Superfície
9.
Biomater Sci ; 8(9): 2404-2419, 2020 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-31993592

RESUMO

Topological design provides additively manufactured (AM) biodegradable porous metallic biomaterials with a unique opportunity to adjust their biodegradation behavior and mechanical properties, thereby satisfying the requirements for ideal bone substitutes. However, no information is available yet concerning the effect of topological design on the performance of AM porous zinc (Zn) that outperforms Mg and Fe in biodegradation behavior. Here, we studied one functionally graded and two uniform AM porous Zn designs with diamond unit cell. Cylindrical specimens were fabricated from pure Zn powder by using a powder bed fusion technique, followed by a comprehensive study on their static and dynamic biodegradation behaviors, mechanical properties, permeability, and biocompatibility. Topological design, indeed, affected the biodegradation behavior of the specimens, as evidenced by 150% variations in biodegradation rate between the three different designs. After in vitro dynamic immersion for 28 days, the AM porous Zn had weight losses of 7-12%, relying on the topological design. The degradation rates satisfied the desired biodegradation time of 1-2 years for bone substitution. The mechanical properties of the biodegraded specimens of all the groups maintained within the range of those of cancellous bone. As opposed to the trends observed for other biodegradable porous metals, after 28 days of in vitro biodegradation, the yield strengths of the specimens of all the groups (σy = 7-14 MPa) increased consistently, as compared to those of the as-built specimens (σy = 4-11 MPa). Moreover, AM porous Zn showed excellent biocompatibility, given that the cellular activities in none of the groups differed from the Ti controls for up to 72 h. Using topological design of AM porous Zn for controlling its mechanical properties and degradation behavior is thus clearly promising, thereby rendering flexibility to the material to meet a variety of clinical requirements.


Assuntos
Materiais Biocompatíveis , Zinco , Implantes Absorvíveis , Linhagem Celular , Humanos , Porosidade
10.
Acta Biomater ; 96: 646-661, 2019 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-31302295

RESUMO

Additively manufactured (AM) functionally graded porous metallic biomaterials offer unique opportunities to satisfy the contradictory design requirements of an ideal bone substitute. However, no functionally graded porous structures have ever been 3D-printed from biodegradable metals, even though biodegradability is crucial both for full tissue regeneration and for the prevention of implant-associated infections in the long term. Here, we present the first ever report on AM functionally graded biodegradable porous metallic biomaterials. We made use of a diamond unit cell for the topological design of four different types of porous structures including two functionally graded structures and two reference uniform structures. Specimens were then fabricated from pure iron powder using selective laser melting (SLM), followed by experimental and computational analyses of their permeability, dynamic biodegradation behavior, mechanical properties, and cytocompatibility. It was found that the topological design with functional gradients controlled the fluid flow, mass transport properties and biodegradation behavior of the AM porous iron specimens, as up to 4-fold variations in permeability and up to 3-fold variations in biodegradation rate were observed for the different experimental groups. After 4 weeks of in vitro biodegradation, the AM porous scaffolds lost 5-16% of their weight. This falls into the desired range of biodegradation rates for bone substitution and confirms our hypothesis that topological design could indeed accelerate the biodegradation of otherwise slowly degrading metals, like iron. Even after 4 weeks of biodegradation, the mechanical properties of the specimens (i.e., E = 0.5-2.1 GPa, σy = 8-48 MPa) remained within the range of the values reported for trabecular bone. Design-dependent cell viability did not differ from gold standard controls for up to 48 h. This study clearly shows the great potential of AM functionally graded porous iron as a bone substituting material. Moreover, we demonstrate that complex topological design permits the control of mechanical properties, degradation behavior of AM porous metallic biomaterials. STATEMENT OF SIGNIFICANCE: No functionally graded porous structures have ever been 3D-printed from biodegradable metals, even though biodegradability is crucial both for full tissue regeneration and for the prevention of implant-associated infections in the long term. Here, we present the first report on 3D-printed functionally graded biodegradable porous metallic biomaterials. Our results suggest that topological design in general, and functional gradients in particular can be used as an important tool for adjusting the biodegradation behavior of AM porous metallic biomaterials. The biodegradation rate and mass transport properties of AM porous iron can be increased while maintaining the bone-mimicking mechanical properties of these biomaterials. The observations reported here underline the importance of proper topological design in the development of AM porous biodegradable metals.


Assuntos
Materiais Biocompatíveis/química , Ferro/química , Impressão Tridimensional , Linhagem Celular , Humanos , Porosidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA