Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
BMC Med Imaging ; 11: 18, 2011 Oct 03.
Artigo em Inglês | MEDLINE | ID: mdl-21967548

RESUMO

BACKGROUND: The American Society of Nuclear Cardiology and the Society of Nuclear Medicine state that incorporation of attenuation-corrected (AC) images in myocardial perfusion scintigraphy (MPS) will improve image quality, interpretive certainty, and diagnostic accuracy. However, commonly used software packages for MPS usually include normal stress databases for non-attenuation corrected (NC) images but not for attenuation-corrected (AC) images. The aim of the study was to develop and compare different normal stress databases for MPS in relation to NC vs. AC images, male vs. female gender, and presence vs. absence of obesity. The principal hypothesis was that differences in mean count values between men and women would be smaller with AC than NC images, thereby allowing for construction and use of gender-independent AC stress database. METHODS: Normal stress perfusion databases were developed with data from 126 male and 205 female patients with normal MPS. The following comparisons were performed for all patients and separately for normal weight vs. obese patients: men vs. women for AC; men vs. women for NC; AC vs. NC for men; and AC vs. NC for women. RESULTS: When comparing AC for men vs. women, only minor differences in mean count values were observed, and there were no differences for normal weight vs. obese patients. For all other analyses major differences were found, particularly for the inferior wall. CONCLUSIONS: The results support the hypothesis that it is possible to use not only gender independent but also weight independent AC stress databases.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Teste de Esforço , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Peso Corporal , Doença da Artéria Coronariana/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Obesidade/fisiopatologia , Compostos Organofosforados , Compostos de Organotecnécio , Compostos Radiofarmacêuticos , Valores de Referência , Reprodutibilidade dos Testes , Fatores Sexuais , Software
2.
Nucl Med Commun ; 28(2): 79-84, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17198346

RESUMO

PURPOSE: To develop a completely automated method based on image processing techniques and artificial neural networks for the interpretation of combined [(18)F]fluorodeoxyglucose (FDG) positron emission tomography (PET) and computed tomography (CT) images for the diagnosis and staging of lung cancer. METHODS: A total of 87 patients who underwent PET/CT examinations due to suspected lung cancer comprised the training group. The test group consisted of PET/CT images from 49 patients suspected with lung cancer. The consensus interpretations by two experienced physicians were used as the 'gold standard' image interpretation. The training group was used in the development of the automated method. The image processing techniques included algorithms for segmentation of the lungs based on the CT images and detection of lesions in the PET images. Lung boundaries from the CT images were used for localization of lesions in the PET images in the feature extraction process. Eight features from each examination were used as inputs to artificial neural networks trained to classify the images. Thereafter, the performance of the network was evaluated in the test set. RESULTS: The performance of the automated method measured as the area under the receiver operating characteristic curve, was 0.97 in the test group, with an accuracy of 92%. The sensitivity was 86% at a specificity of 100%. CONCLUSIONS: A completely automated method using artificial neural networks can be used to detect lung cancer with such a high accuracy that the application as a clinical decision support tool appears to have significant potential.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Reconhecimento Automatizado de Padrão/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Automação , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Redes Neurais de Computação , Curva ROC
3.
Nucl Med Commun ; 27(5): 417-23, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16609352

RESUMO

OBJECTIVE: To develop a completely automated method, based on image processing techniques and artificial neural networks, for the interpretation of bone scans regarding the presence or absence of metastases. METHODS: A total of 200 patients, all of whom had the diagnosis of breast or prostate cancer and had undergone bone scintigraphy, were studied retrospectively. Whole-body images, anterior and posterior, were obtained after injection of 99mTc-methylene diphosphonate. The study material was randomly divided into a training group and a test group, with 100 patients in each group. The training group was used in the process of developing the image analysis techniques and to train the artificial neural networks. The test group was used to evaluate the automated method. The image processing techniques included algorithms for segmentation of the head, chest, spine, pelvis and bladder, automatic thresholding and detection of hot spots. Fourteen features from each examination were used as input to artificial neural networks trained to classify the images. The interpretations by an experienced physician were used as the 'gold standard'. RESULTS: The automated method correctly identified 28 of the 31 patients with metastases in the test group, i.e., a sensitivity of 90%. A false positive classification of metastases was made in 18 of the 69 patients not classified as having metastases by the experienced physician, resulting in a specificity of 74%. CONCLUSION: A completely automated method can be used to detect metastases in bone scans. Future developments in this field may lead to clinically valuable decision-support tools.


Assuntos
Inteligência Artificial , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Técnicas de Apoio para a Decisão , Interpretação de Imagem Assistida por Computador/métodos , Medronato de Tecnécio Tc 99m , Imagem Corporal Total/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Humanos , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão/métodos , Cintilografia , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco/métodos , Fatores de Risco , Sensibilidade e Especificidade , Suécia/epidemiologia
4.
Clin Physiol Funct Imaging ; 32(2): 114-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22296631

RESUMO

Most nuclear medicine clinicians use only visual assessment when interpreting regional cerebral blood flow (rCBF) from single-photon emission computed tomography (SPECT) images in clinical practice. The aims of this study were to develop a new, easy to use, automated method for quantification of rCBF-SPECT and to create normal values by using the method on a normal population. We developed a 3-dimensional method based on a brain-shaped model and the active-shape algorithm. The method defines the surface shape of the brain and then projects the maximum counts 0-1.5 cm deep for designated surface points. These surface projection values are divided into cortical regions representing the different lobes and presented relative to the whole cortex, cerebellum or cerebellar maximum. (99m) Tc-hexa methyl propylene amine oxime (HMPAO) SPECT was performed on 30 healthy volunteers with a mean age of 74 years (range 64-98). The ability of the active-shape algorithm to define the shape of the brain was satisfactory when visually scrutinized. The results of the quantification show rCBF values in the frontal, temporal and parietal lobes of 87-88% using cerebellum as the reference. There were no significant differences in normal rCBF values between male and female subjects and only a weak relation between rCBF and age. In conclusion, our new automated method was able to quantify rCBF-SPECT images and create normal values in ranges as expected. Further studies are needed to assess the clinical value of this method and the normal values.


Assuntos
Algoritmos , Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Interpretação de Imagem Assistida por Computador/métodos , Modelos Cardiovasculares , Imagem de Perfusão/métodos , Tomografia por Emissão de Pósitrons , Idoso , Idoso de 80 Anos ou mais , Automação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/normas , Tomografia por Emissão de Pósitrons/normas , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos , Valores de Referência , Suécia , Tecnécio Tc 99m Exametazima
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA