Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Int Urogynecol J ; 35(7): 1521-1526, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38900162

RESUMO

INTRODUCTION AND HYPOTHESIS: The objective was to assess intraoperative and postoperative complication rates, along with perioperative and surgical outcomes, following single-port robotics-assisted sacrocolpopexy. METHODS: This retrospective case series included 200 patients who underwent single-port robotics-assisted sacrocolpopexy to treat Pelvic Organ Prolapse Quantification (POPQ) stage 2-4 symptomatic prolapse between April 2020 and August 2023 by a single surgeon. Intraoperative and postoperative complications and perioperative outcomes were evaluated for all the patients, whereas surgical outcomes for 74 patients were assessed at 1-year follow-up. Surgical failure was defined as the presence of any of the following: the presence of vaginal bulging symptoms, any prolapse beyond the hymen, or retreatment for prolapse. RESULTS: During the study period, 200 single-port robotics-assisted sacrocolpopexies were performed. The median age and body mass index were 65.0 years and 24.6 kg/m2 respectively. Most patients had POPQ stage 3 or 4 prolapse and underwent concomitant total hysterectomy. The median total operation time was 212.0 min, and none of the patients required conversion to laparoscopy or laparotomy. The intraoperative cystotomy rate was 2.5%, and one patient had a blood transfusion owing to presacral vessel injury. Postoperative complications of mesh exposure and wound hernia were 0.5% and 2.0% respectively. At 1 year postoperatively, the rate of composite surgical failure was 9.5%, with a 5.4% anatomical recurrence rate. None of the patients experienced apical prolapse recurrence, and one received anterior colporrhaphy for anterior compartment prolapse recurrence. CONCLUSIONS: Single-port robotics-assisted sacrocolpopexy is safe and effective, with low complication rates and favorable perioperative and surgical outcomes.


Assuntos
Procedimentos Cirúrgicos em Ginecologia , Complicações Intraoperatórias , Prolapso de Órgão Pélvico , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Robóticos , Humanos , Feminino , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Prolapso de Órgão Pélvico/cirurgia , Idoso , Pessoa de Meia-Idade , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/epidemiologia , Resultado do Tratamento , Procedimentos Cirúrgicos em Ginecologia/métodos , Procedimentos Cirúrgicos em Ginecologia/efeitos adversos , Duração da Cirurgia , Vagina/cirurgia
2.
Sci Rep ; 14(1): 9099, 2024 04 20.
Artigo em Inglês | MEDLINE | ID: mdl-38643310

RESUMO

To investigate the impact on the ovarian reserve after minimally invasive ovarian cystectomy using two platforms, the Da Vinci robotic system (Xi and SP) and the laparoscopic system. Patients underwent laparoscopic or Da Vinci robotic (Xi or SP) ovarian cystectomy for benign ovarian cysts between January 1, 2018, and December 31, 2022 at Guro Hospital, Korea University Medical center. We measured the change of AMH values (%) = [(postAMH - preAMH)] × 100/preAMH. No significant differences in preoperative age, cyst size, estimated blood loss during surgery, hemoglobin drop, length of hospital stay, adhesion detachment rate and cyst rupture rate were observed. However, the operative time was significantly shorter in the laparoscopic group than that in the robotic group (67.78 ± 30.58 min vs. 105.17 ± 38.87 min, p < 0.001) The mean preAMH and postAMH were significantly higher with the Da Vinci robotic group than with the laparoscopic group (preAMH: 5.89 ± 4.81 ng/mL vs. 4.01 ± 3.59 ng/mL, p = 0.02, postAMH: 4.36 ± 3.31 ng/mL vs. 3.08 ± 2.60 ng/mL, p = 0.02). However, the mean ΔAMH was not significantly different between two groups. ΔAMH also did not demonstrate significant differences among the three groups; laparoscopic, Xi and SP robotic. Even in the patient groups with preAMH < 2 and diagnosed with endometriosis, the ΔAMH did not show significant differences between the laparoscopic and robotic groups. The Da Vinci robotic system is no inferior to conventional laparoscopic systems in preserving ovarian function.


Assuntos
Cistos , Laparoscopia , Reserva Ovariana , Procedimentos Cirúrgicos Robóticos , Feminino , Humanos , Hormônio Antimülleriano , Cistectomia , Resultado do Tratamento
3.
Obstet Gynecol Sci ; 66(1): 20-25, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36444516

RESUMO

OBJECTIVE: The aim of this study was to evaluate the changes in twin pregnancy outcomes between 2007 and 2016 in a Korean population. METHODS: The data for this nationwide population-based study was obtained from the national birth registry of the Korean National Statistical Office and the Health Insurance Review & Assessment Service of Korea. Women with twin pregnancies who gave birth between 2007 and 2016 were included. RESULTS: From 2007 to 2016, the rate of twin pregnancies increased (1.37% vs. 1.91%, respectively, P<0.0001). The risk of preterm birth (adjusted odds ratio [aOR], 1.77; 95% confidence interval [CI], 1.66-1.89) also increased; however, the risk of twin growth discordance (aOR, 0.90; 95% CI, 0.82-0.99) decreased. The risks of cesarean section (aOR, 1.16; 95% CI, 1.03-1.29), gestational diabetes mellitus (aOR, 2.10; 95% CI, 1.83-2.39), and postpartum hemorrhage (aOR, 1.27; 95% CI, 1.14-1.41) all increased from 2007 to 2016. CONCLUSION: Twin pregnancy outcomes have changed significantly in Korea over a recent 10-year period.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA