Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Nano Lett ; 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38557080

RESUMO

Modern semiconductor fabrication is challenged by difficulties in overcoming physical and chemical constraints. A major challenge is the wet etching of dummy gate silicon, which involves the removal of materials inside confined spaces of a few nanometers. These chemical processes are significantly different in the nanoscale and bulk. Previously, electrical double-layer formation, bubble entrapment, poor wettability, and insoluble intermediate precipitation have been proposed. However, the exact suppression mechanisms remain unclear due to the lack of direct observation methods. Herein, we investigate limiting factors for the etching kinetics of silicon with tetramethylammonium hydroxide at the nanoscale by using liquid-phase transmission electron microscopy, three-dimensional electron tomography, and first-principles calculations. We reveal suppressed chemical reactions, unstripping phenomena, and stochastic etching behaviors that have never been observed on a macroscopic scale. We expect that solutions can be suggested from this comprehensive insight into the scale-dependent limiting factors of fabrication.

2.
Eur J Appl Physiol ; 123(3): 573-583, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36411398

RESUMO

PURPOSE: This study aimed to investigate: 1. The influence of sex and age on the accuracy of the classical model of endurance performance, including maximal oxygen uptake ([Formula: see text]), its fraction (LT2%), and cost of running (CR), for calculating running speed at lactate threshold 2 (vLT2) in young athletes. 2. The impact of different CR determination methods on the accuracy of the model. 3. The contributions of [Formula: see text], LT2%, and CR to vLT2 in different sexes. METHODS: 45 male and 55 female young squad athletes from different sports (age: 15.4 ± 1.3 years; [Formula: see text]: 51.4 ± 6.8 [Formula: see text]) performed an incremental treadmill test to determine [Formula: see text], LT2%, CR, and vLT2. CR was assessed at a fixed running speed (2.8 [Formula: see text]), at lactate threshold 1 (LT1), and at 80% of [Formula: see text], respectively. RESULTS: Experimentally determined and modeled vLT2 were highly consistent independent of sex and age (ICC [Formula: see text] 0.959). The accuracy of vLT2 modeling was improved by reducing random variation using individualized CR at 80% [Formula: see text] (± 4%) compared to CR at LT1 (± 7%) and at a fixed speed (± 8%). 97% of the total variance of vLT2 was explained by [Formula: see text], LT2%, and CR. While [Formula: see text] and CR showed the highest unique (96.5% and 31.9% of total [Formula: see text], respectively) and common (- 31.6%) contributions to the regression model, LT2% made the smallest contribution (7.5%). CONCLUSION: Our findings indicate: 1. High accuracy of the classical model of endurance performance in calculating vLT2 in young athletes independent of age and sex. 2. The importance of work rate selection in determining CR to accurately predict vLT2. 3. The largest contribution of [Formula: see text] and CR to vLT2, the latter being more important in female athletes than in males, and the least contribution of LT2%.


Assuntos
Ácido Láctico , Corrida , Humanos , Masculino , Feminino , Adolescente , Consumo de Oxigênio , Teste de Esforço/métodos , Atletas , Oxigênio
3.
J Strength Cond Res ; 36(12): 3280-3289, 2022 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34319941

RESUMO

ABSTRACT: Ji, S, Donath, L, and Wahl, P. Effects of alternating unilateral vs. bilateral resistance training on sprint and endurance cycling performance in trained endurance athletes: A 3-armed, randomized, controlled, pilot trial. J Strength Cond Res 36(12): 3280-3289, 2022-Traditional preparatory resistance training for cyclists mainly relies on simultaneous bilateral movement patterns. This lack of movement specificity may impede transfer effects to specific aerobic and anaerobic requirements on the bike. Hence, this study investigated the effects of resistance training in alternating unilateral vs. simultaneous bilateral movement pattern on strength and anaerobic as well as aerobic cycling performance indices. Twenty-four trained triathletes and cyclists (age: 31.1 ± 8.1 years; V̇ o2 max: 57.6 ± 7.1 ml·min -1 ·kg -1 ) were randomly assigned to either an alternating unilateral (AUL), a simultaneous bilateral (BIL) training group or a control group (CON). Ten weeks of resistance training (4 × 4-10 repetition maximum) were completed by both training groups, although CON maintained their usual training regimen without resistance training. Maximal strength was tested during isometric leg extension, leg curl, and leg press in both unilateral and bilateral conditions. To compare the transfer effects of the training groups, determinants of cycling performance and time to exhaustion at 105% of the estimated anaerobic threshold were examined. Maximal leg strength notably increased in both training groups (BIL: ∼28%; AUL: ∼27%; p < 0.01) but not in CON (∼6%; p > 0.54). A significant improvement in cycling time trial performance was also observed in both training groups (AUL: 67%; BIL: 43%; p < 0.05) but not for CON (37%; p = 0.43). Bilateral group exhibited an improved cycling economy at submaximal intensities (∼8%; p < 0.05) but no changes occurred in AUL and CON (∼3%; p > 0.24). While sprint cycling performance decreased in CON (peak power: -6%; acceleration index: -15%; p < 0.05), improvement in favor of AUL was observed for acceleration abilities during maximal sprinting (20%; d = 0.5). Our pilot data underpin the importance of resistance training independent of its specific movement pattern both for improving the endurance cycling performance and maximal leg strength. Further research should corroborate our preliminary findings on whether sprint cycling benefits favorably from AUL resistance training.


Assuntos
Desempenho Atlético , Treinamento Resistido , Humanos , Adulto Jovem , Adulto , Ciclismo , Resistência Física , Projetos Piloto , Teste de Esforço , Consumo de Oxigênio , Atletas
4.
Medicina (Kaunas) ; 57(10)2021 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-34684154

RESUMO

Background and Objectives: This study aimed to compare the calculated running velocity at the anaerobic lactate threshold (cLTAn), determined by a mathematical model for metabolic simulation, with two established threshold concepts (onset of blood lactate accumulation (OBLA; 4 mmol∙L-1) and modified maximal deviation method (mDmax)). Additionally, all threshold concepts were correlated with performance in different endurance running events. Materials and Methods: Ten sub-elite runners performed a 30 s sprint test on a cycle ergometer adjusted to an isokinetic mode set to a cadence of 120 rpm to determine maximal lactate production rate (VLamax), and a graded exercise test on a treadmill to determine maximal oxygen uptake (VO2max). Running velocities at OBLA, mDmax, and cLTAn were then compared with each other, and further correlated with running performance over various distances (3000 m, 5000 m, and 10,000 m). Results: The mean difference in cLTAn was -0.13 ± 0.43 m∙s-1 and -0.32 ± 0.39 m∙s-1 compared to mDmax (p = 0.49) and OBLA (p < 0.01), respectively. cLTAn indicated moderate to good concordance with the established threshold concepts (mDmax: ICC = 0.87, OBLA: ICC = 0.74). In comparison with other threshold concepts, cLTAn exhibited comparable correlations with the assessed running performances (cLTAn: r = 0.61-0.76, mDmax: r = 0.69-0.79, OBLA: r = 0.56-0.69). Conclusion: Our data show that cLTAn can be applied for determining endurance performance during running. Due to the consideration of individual physiological profiles, cLTAn offers a physiologically justified approach to assess an athlete's endurance performance.


Assuntos
Ácido Láctico , Corrida , Limiar Anaeróbio , Anaerobiose , Teste de Esforço , Humanos , Resistência Física
5.
Adv Mater ; 36(6): e2309936, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38016113

RESUMO

Single-molecule techniques are powerful microscopy methods that provide new insights into biological processes. Liquid-phase transmission electron microscopy (LP-TEM) is an ideal single-molecule technique for overcoming the poor spatiotemporal resolution of optical approaches. However, single-molecule LP-TEM is limited by several challenges such as electron-beam-induced molecular damage, difficulty in identifying biomolecular species, and a lack of analytical approaches for conformational dynamics. Herein, a single-molecule graphene liquid-cell TEM (GLC-TEM) technique that enables the investigation of real-time structural perturbations of intact amyloid fibrils is presented. It is demonstrated that graphene membranes significantly extend the observation period of native amyloid beta proteins without causing oxidative damage owing to electron beams, which is necessary for imaging. Stochastic and time-resolved investigations of single fibrils reveal that structural perturbations in the early fibrillar stage are responsible for the formation of various amyloid polymorphs. The advantage of observing structural behavior in real time with unprecedented resolution will potentially make GLC-TEM a complementary approach to other single-molecule techniques.


Assuntos
Grafite , Grafite/química , Amiloide/química , Elétrons , Peptídeos beta-Amiloides , Microscopia Eletrônica de Transmissão
6.
Int J Sports Physiol Perform ; 18(12): 1398-1411, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37730208

RESUMO

PURPOSE: The study examined the longitudinal interplay of anthropometric, metabolic, and neuromuscular development related to performance in adolescent national-level swimmers over 12 months. METHODS: Seven male and 12 female swimmers (14.8 [1.3] y, FINA [International Swimming Federation] points 716 [51]) were tested before (T0) and after the preparation period (T1), at the season's peak (T2), and before the next season (T3). Anthropometric (eg, fat percentage) and neuromuscular parameters (squat and bench-press load-velocity profile) were assessed on dry land. Metabolic (cost of swimming [C], maximal oxygen uptake [V˙O2peak], and peak blood lactate [bLapeak]) and performance (sprinting speed [vsprint] and lactate thresholds [LT1 and 2]) factors were determined using a 500-m submaximal, 200-m all-out, 20-second sprint, and incremental test (+0.03 m·s-1, 3 min), respectively, in front-crawl swimming. RESULTS: vsprint (+0.6%) and LT1 and 2 (+1.9-2.4%) increased trivially and slightly, respectively, from T0 to T2 following small to moderate strength increases (≥+10.2%) from T0 to T1 and V˙O2peak (+6.0%) from T1 to T2. Bench-press maximal strength and peak power correlated with vsprint from T0 to T2 (r ≥ .54, P < .05) and LT2 at T1 (r ≥ .47, P < .05). Changes in fat percentage and V˙O2peak (T2-T1 and T3-T2, r ≤ -.67, P < .01) and C and LT2 (T2-T0, r = -.52, P = .047) were also correlated. CONCLUSIONS: Increases in strength and V˙O2peak from preparation to the competition period resulted in improved sprint and endurance performance. Across the season, upper-body strength was associated with vsprint and LT2, although their changes were unrelated.


Assuntos
Ácido Láctico , Natação , Humanos , Masculino , Adolescente , Feminino , Antropometria , Estado Nutricional
7.
Front Physiol ; 14: 1285462, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38162828

RESUMO

Purpose: Blood-Flow-Restriction (BFR) training provides the ability to achieve hypertrophy effects even though only light mechanical loads are applied. However, its impact on venous pressures and function are still unknown. Therefore, the present study investigates the influence of BFR-training on intravascular venous pressure and venous function in comparison to control exercises with low or high mechanical loads. Methods: In a randomized cross-over design, ten healthy men (27.6 ± 6.4 years) underwent three trials of unilateral knee-extensor exercise with three different training protocols, low-load- (LL-RT, 30% of the individual 1-repetition-maximum, 1RM), low-load BFR- (LL-BFR-RT, 30% 1RM, 50% limb occlusion pressure, LOP) and high-load resistance exercise (HL-RT, 75% 1RM). Exercise protocols contain about four sets of knee extension exercise (Range-of-Motion: 0-0-95°), separated by 60 s of rest. Each set was performed until volitional muscle failure. For analysis of changes in intravascular venous pressures and venous function, a venous catheter was placed at the exercising leg before each trial. Whereas venous pressures were recorded throughout the exercise trials, phlebodynamometric investigations were performed before and after each trial. Furthermore, subjective pain perception during and after exercise was accessed by visual analogue scale. One-way ANOVA was used to assess mean differences between training protocols, while two-way repeated-measures ANOVA (rANOVA; time x condition) was performed to compare changes in measures over time among conditions. Data were given as means ± standard deviation (SD). Results: In comparison to the exercise trials without venous occlusion, total workload was significantly lower in the LL-BFR-RT (LL-RT: 1745 ± 604 kg vs LL-BFR-RT: 1274 ± 237 kg vs HL-RT: 1847 ± 367 kg, p = 0.004) without indicating statistical differences in venous pressures during the exercise sets (interaction: p = 0.140) or pain perception (interaction: p = 0.574). Similarly, phlebodynamometric assessment of venous function (e.g. refill-time of the venous system pre-vs. post exercise trials-LL-RT: 29.7 ± 11.0 s vs 25.5 ± 9.6 s, LL-BFR-RT: 26.6 ± 13.0 s vs 27.3 ± 13.8 s, HL-RT: 25.9 ± 10.9 s vs 23.1 ± 8.2 s) revealed no time (p = 0.156), condition effect (p = 0.802) or their interactions (p = 0.382). Conclusion: The present study is the first one describing the acute effects of LL-BFR-RT to muscle failure on venous pressures and function in comparison to a LL- and HL-RT in the lower limbs. In contrast to the existing literature, LL-BFR-RT does not elevate the venous pressures during exercise higher than a comparative exercise without BFR and does not show any adverse effects on venous function after the exercise.

8.
Nanoscale ; 15(4): 1794-1805, 2023 Jan 27.
Artigo em Inglês | MEDLINE | ID: mdl-36602000

RESUMO

The design of nanostructured materials for efficient bifunctional electrocatalysts has gained tremendous attention, yet developing a fast and effective synthesis strategy remains a challenge. Here, we present a fast and scalable synthetic method of Ni/Co/Co3O4@C nanorods for efficient overall water splitting. Using microwave synthesis, we first produced a unique Ni-MOF@Co-MOF in a few minutes. Subsequently, we transformed the MOF@MOF into hybrid Ni/Co/Co3O4 nanoparticles covered with graphitic carbon in a few seconds using laser-scribing. The prepared bimetallic catalysts showed remarkably low overpotentials of 246 mV for the oxygen evolution reaction (OER) and 143 mV for the hydrogen evolution reaction (HER) at a current density of 30 mA cm-2. An electrolyzer assembled with the bimetallic catalysts delivered a high current density of 20 mA cm-2 at a voltage of 1.6 V and exhibited good durability (nearly 91.6% retention even after a long-running operation of 24 h at a voltage of 1.52 V). Our proposed method could serve as a powerful method for creating various multimetallic hybrid nanocatalysts with unique hierarchical structures from diverse MOFs.

9.
Front Physiol ; 13: 881484, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35774280

RESUMO

Introduction: Total Knee Arthroplasty (TKA) is one of the most successful interventions in gonarthrosis, however the operation is leading to muscle atrophy and long-term muscular deficits. To enhance rehabilitation after TKA, exercise programs try to improve muscle function preoperatively, called prehabilitation. Blood-Flow-Restriction Exercises (BFRE) is a training method which is characterized by using tourniquets to reduce arterial and occlude venous blood flow simultaneously during the exercise to increase metabolic stress. The present study aimed to evaluate the effects of a 6-week prehabilitation with BFR on pre- and postoperative muscle mass, strength, and quality of life (QoL). Methods: 30 patients with end-stage gonarthrosis participated in this study. Patients were randomized into one of three groups: 1) Control-Group (CON): Standard clinical approach without prehabilitation. 2) Active-Control-Group (AC): Participation in a prehabilitation with sham-BFR. 3) BFR-Group (BFR): Participation in a prehabilitation with BFR. The prehabilitation protocol consist of a cycling-ergometer-based training performed twice per week over 6 weeks. During exercise, BFR was applied periodically three times per leg with a pressure of 40% of the individual-limb-occlusion-pressure. Measurement time points were six- (baseline), 3-weeks and 5-days before the surgery (Pre-OP), as well as three- and 6-months postoperatively. Outcome measures were muscular strength of the thigh muscles, thigh circumference as well as QoL and functional activity, examined by 6-min walking- and chair rising test. Results: Both training groups indicated significantly improved leg muscle strength following the prehabilitation period with a superior effect for the BFR-group (BFR: ∼170% vs. AC: ∼91%, p < 0.05). No significant changes in leg strength occurred in the CON (∼3%, p = 0.100). Further, patients in BFR-group indicated significantly improved skeletal muscle mass assessed by femoral circumference following prehabilitation period (∼7%, p < 0.05), while no significant changes occurred in the CON (-1.14%, p = 0.131) and AC-group (∼3%, p = 0.078). At 3-months Post-OP, the CON and BFR-group revealed a significant decrease in femoral circumference compared to the Pre-OP (CON: ∼3%, BFR: ∼4%; p < 0.05), but BFR-group remained above the baseline level (∼3%, p < 0.05). No significant change in femoral circumference was found for AC-group (∼2%, p = 0.078). In addition, the prehabilitation with BFR provided notably improved Knee Injury and Osteoarthritis Outcome Scores (KOOS) especially in pain perception with significant higher effect compared to other groups (CON: -2%, AC: 13%, BFR: 41%; p < 0.05). In long-term rehabilitation after 6-months, all groups showed significantly improved KOOS scores in all dimensions (CON: ∼110%, AC: ∼132%, BFR: ∼225%; p < 0.01), and functional examinations (CON: ∼26%, AC: ∼16%, BFR: ∼53%; p < 0.01). Conclusion: The present findings show that BFR-prehabilitation induce significant improvements in muscle function and QoL before TKA surgery. In addition, the supporting effect of prehabilitation on postoperative regeneration and QoL should be highlighted, illustrating prolonged beneficial effects of BFR on muscular and functional performance in a "better in, better out"-manner.

10.
Adv Mater ; 33(2): e2005468, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33215775

RESUMO

The recent advances in liquid-phase transmission electron microscopy represent tremendous potential in many different fields and exciting new opportunities. However, achieving both high-resolution imaging and operando capabilities remain a significant challenge. This work suggests a novel in situ imaging platform of liquid-flowing graphene chip TEM (LFGC-TEM) equipped with graphene viewing windows and a liquid exchange system. The LFGCs are robust under high-pressure gradients and rapid liquid circulation in ranges covering the experimental conditions accessible with conventional thick SiNx chips. LFGC-TEM provides atomic resolution for colloidal nanoparticles and molecular-level information limits for unstained wet biomolecules and cells that are comparable to the resolutions achievable with solid-phase and cryogenic TEM, respectively. This imaging platform can provide an opportunity for live imaging of biological phenomena that is not yet achieved using any current methods.


Assuntos
Grafite/química , Microscopia Eletrônica/métodos , Razão Sinal-Ruído , Nanopartículas
11.
ACS Nano ; 15(1): 288-308, 2021 01 26.
Artigo em Inglês | MEDLINE | ID: mdl-33395264

RESUMO

Graphene liquid cell electron microscopy (GLC-EM), a cutting-edge liquid-phase EM technique, has become a powerful tool to directly visualize wet biological samples and the microstructural dynamics of nanomaterials in liquids. GLC uses graphene sheets with a one carbon atom thickness as a viewing window and a liquid container. As a result, GLC facilitates atomic-scale observation while sustaining intact liquids inside an ultra-high-vacuum transmission electron microscopy chamber. Using GLC-EM, diverse scientific results have been recently reported in the material, colloidal, environmental, and life science fields. Here, the developments of GLC fabrications, such as first-generation veil-type cells, second-generation well-type cells, and third-generation liquid-flowing cells, are summarized. Moreover, recent GLC-EM studies on colloidal nanoparticles, battery electrodes, mineralization, and wet biological samples are also highlighted. Finally, the considerations and future opportunities associated with GLC-EM are discussed to offer broad understanding and insight on atomic-resolution imaging in liquid-state dynamics.


Assuntos
Grafite , Nanopartículas , Fontes de Energia Elétrica , Microscopia Eletrônica , Microscopia Eletrônica de Transmissão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA