1.
Pak J Med Sci ; 40(4): 773-778, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38545011

RESUMO

Objective: To assess and compare the clinical and functional outcomes of corticosteroid injections in patients with carpal tunnel syndrome, focusing on two different approaches: ultrasound-guided and landmark-guided. Methods: A systematic search was conducted in PubMed, Scopus and Embase databases for relevant studies published prior to 30th April 2023. Studies that were either randomized controlled trials or had a cohort design were included. The review assessed symptom severity, functional status, electrodiagnostic parameters, complications, need for surgical intervention, visual analogue score, and grip strength. Pooled effect sizes were reported as relative risk (RR) or weighted mean difference (WMD). Results: A total of 8 articles were included. Compared to those that received steroid injection using landmark approach, those with ultrasound guided approach had lower symptom severity scale (SSS) score on Boston Carpal Tunnel Questionnaire (BCTQ) [WMD -0.50, 95% CI: -0.94, -0.07; I2=78.0%, N=7], lower risk of "any complications" [RR 0.58, 95% CI: 0.36, 0.93; I2= 22.9%, N=3] and lower risk of need for surgical intervention [RR 0.55, 95% CI: 0.34, 0.89; I2= 3.0%, N=2]. All other parameters were similar in the two groups i.e., functional status scale (FSS) score, visual analogue score (VAS) and grip strength. The electrophysiological findings were similar in the two groups. Conclusion: Findings suggest that ultrasound guided approach may be better than landmark guided approach especially in terms of alleviation of symptoms, reducing the risk of complications and need for surgical intervention. However, larger trials with long term follow up may provide conclusive evidence.

2.
Sci Rep ; 11(1): 1093, 2021 Jan 13.
Artigo em Inglês | MEDLINE | ID: mdl-33441851

RESUMO

Unlike the single grating Czerny-Turner configuration spectrometers, a super-high spectral resolution optical spectrometer with zero coma aberration is first experimentally demonstrated by using a compound integrated diffraction grating module consisting of 44 high dispersion sub-gratings and a two-dimensional backside-illuminated charge-coupled device array photodetector. The demonstrated super-high resolution spectrometer gives 0.005 nm (5 pm) spectral resolution in ultra-violet range and 0.01 nm spectral resolution in the visible range, as well as a uniform efficiency of diffraction in a broad 200 nm to 1000 nm wavelength region. Our new zero-off-axis spectrometer configuration has the unique merit that enables it to be used for a wide range of spectral sensing and measurement applications.

3.
Sci Rep ; 10(1): 12780, 2020 Jul 29.
Artigo em Inglês | MEDLINE | ID: mdl-32728183

RESUMO

Multilayer optical film plays a significant role in broad fields of optical application. Due to the nonlinear relationship between the dispersion characteristics of optical materials and the actual performance parameters of optical thin films, it is challenging to optimize optical thin film structure with the traditional models. In this paper, we present an implementation of Deep Q-learning, which suited for the most part for optical thin film. As a set of concrete demonstrations, we optimize solar absorber. The optimal program could optimal this solar absorber in 500 epoch (about 200 steps per-epoch) without any human intervention. Search results perform better than researchers' manual searches.

4.
World J Clin Cases ; 8(23): 6136-6143, 2020 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-33344615

RESUMO

BACKGROUND: Posterior atlantoaxial dislocation (PAD) is a rare type of upper cervical spine disease. We sought to describe a unreported case of old PAD with os odontoideum (OO) and atlas hypoplasia (AH) and our unique treatment approach consisting of C1 single door laminoplasty with C1-3 posterior fixation and fusion. CASE SUMMARY: A 70-year-old male patient who suffered from progressive aggravating numbness and limb weakness for 4 years without trauma, was diagnosed with old PAD with OO and AH. The patient underwent closed reduction and C1 single door laminoplasty with C1-3 posterior fixation and fusion instead of C1 laminectomy with occipitocervical fusion. During the 3-year follow-up, he was able to walk by himself instead of using a wheelchair and with a ± 25° range of head rotation as well as a ± 10° range of flexion-extension. Three-year follow-up images showed satisfactory reduction and fusion. CONCLUSION: C1 single door laminoplasty with cervical fusion in PAD combined with spinal cord compression could be a suitable and effective surgical option. Compared with laminectomy and occipitocervical fusion, it retains more cervical range of motion, has a smaller incision and provides an adequate bone grafting space for atlantoaxial fusion.

5.
Sci Rep ; 9(1): 12434, 2019 Aug 27.
Artigo em Inglês | MEDLINE | ID: mdl-31455835

RESUMO

In this work, the two-dimensional profile of the light transmission through a prism-like metallic film sample of Au was measured at a wavelength of 632.8 nm in the visible intraband transition region to verify that, beyond the possible mechanisms of overcoming the diffraction limit, a strongly nonuniform optical absorption path length of the light traveling in the metal could induce a lensing effect, thereby narrowing the image of an object. A set of prism-like Au samples with different angles was prepared and experimentally investigated. Due to the nonuniform paths of the light traveling in the Au samples, lens-effect-like phenomena were clearly observed that reduced the imaged size of the beam spot with decreasing light intensity. The experimental measurements presented in the work may provide new insight to better understand the light propagation behavior at a metal/dielectric interface.

6.
Sci Rep ; 9(1): 10211, 2019 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-31308474

RESUMO

Optical spectrometers play a key role in acquiring rich photonic information in both scientific research and a wide variety of applications. In this work, we present a new spectrometer with an ultrahigh resolution of better than 0.012 nm/pixel in the 170-600 nm spectral region using a grating-integrated module that consists of 19 subgratings without any moving parts. By using two-dimensional (2D) backsideilluminated complementary metal-oxide-semiconductor (BSI-CMOS) array detector technology with 2048 × 2048 pixels, a high data acquisition speed of approximately 25 spectra per second is achieved. The physical photon-sensing size of the detector along the one-dimensional wavelength direction is enhanced by a factor of 19 to approximately 428 mm, or 38912 pixels, to satisfy the requirement of seamless connection between two neighboring subspectral regions without any missing wavelengths throughout the entire spectral region. As tested with a mercury lamp, the system has advanced performance capabilities characterized by the highest k parameter reported to date, being approximately 3.58 × 104, where k = (working wavelength region)/(pixel resolution). Data calibration and analysis as well as a method of reducing background noise more efficiently are also discussed. The results presented in this work will stimulate further research on precision spectrometers based on advanced BSI-CMOS array detectors in the future.

7.
Sci Rep ; 8(1): 12660, 2018 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-30139954

RESUMO

Optical spectrometers play an important role in modern scientific research. In this work, we present a two-channel spectrometer with a pixel resolution of better than 0.1 nm/pixel in the wavelength range of 200 to 950 nm and an acquisition speed of approximately 25 spectra per second. The spectrometer reaches a high k factor which characterizes the spectral performance of the spectrometer as k = (working wavelength region)/(pixel resolution) = 7500. Instead of using mechanical moving parts in traditional designs, the spectrometer consists of 8 integrated sub-gratings for diffracting and imaging two sets of 4-folded spectra on the upper and lower parts, respectively, of the focal plane of a two-dimensional backside-illuminated complementary metal-oxide-semiconductor (BSI-CMOS) array detector, which shows a high peak quantum efficiency of approximately 90% at 400 nm. In addition to the advantage of being cost-effective, the compact design of the spectrometer makes it advantageous for applications in which it is desirable to use the same two-dimensional array detector to simultaneously measure multiple spectra under precisely the same working conditions to reduce environmental effects. The performance of the finished spectrometer is tested and confirmed with an Hg-Ar lamp.

8.
Sci Rep ; 7: 44614, 2017 03 16.
Artigo em Inglês | MEDLINE | ID: mdl-28300178

RESUMO

In this work, 4-layered SiO2/Bi2Te3/SiO2/Cu film structures were designed and fabricated and the optical properties investigated in the wavelength region of 250-1200 nm for their promising applications for direct solar-thermal-electric conversion. A typical 4-layered film sample with the structure SiO2 (66.6 nm)/Bi2Te3 (7.0 nm)/SiO2 (67.0 nm)/Cu (>100.0 nm) was deposited on a Si or K9-glass substrate by magnetron sputtering. The experimental results agree well with the simulated ones showing an average optical absorption of 96.5%, except in the shorter wavelength region, 250-500 nm, which demonstrates the superior absorption property of the 4-layered film due to the randomly rough surface of the Cu layer resulting from the higher deposition power. The high reflectance of the film structure in the long wavelength region of 2-20 µm will result in a low thermal emittance, 0.064 at 600 K. The simpler 4-layered structure with the thermoelectric Bi2Te3 used as the absorption layer may provide a straightforward way to obtain solar-thermal-electric conversion more efficiently through future study.