Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Angew Chem Int Ed Engl ; 62(4): e202215652, 2023 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-36399135

RESUMO

A design strategy that combines molecular conformation, alkyl chain length, and charge-transfer effects has been developed to obtain conformational and stacking-adaptable donor-acceptor-π type molecules for precisely regulating the monomer and excimer emission in a single luminous platform under different environments. These fluorophores can exhibit bright monomer emissions when they are in the dispersed state based on their planar conformation. However, when the luminous molecules with short alkyl side chains are in the crystalline state, their molecular conformation can become distorted, further inducing strong intermolecular interactions and staggered π-π stacking for bright excimer emission. More importantly, their dispersed and aggregated states can be reversibly regulated in a phase-change fatty acid matrix, to achieve temperature-responsive fluorescence for temperature monitoring and advanced information encryption.

2.
Front Neurosci ; 16: 883693, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35600611

RESUMO

In this article, a novel method for continuous blood pressure (BP) estimation based on multi-scale feature extraction by the neural network with multi-task learning (MST-net) has been proposed and evaluated. First, we preprocess the target (Electrocardiograph; Photoplethysmography) and label signals (arterial blood pressure), especially using peak-to-peak time limits of signals to eliminate the interference of the false peak. Then, we design a MST-net to extract multi-scale features related to BP, fully excavate and learn the relationship between multi-scale features and BP, and then estimate three BP values simultaneously. Finally, the performance of the developed neural network is verified by using a public multi-parameter intelligent monitoring waveform database. The results show that the mean absolute error ± standard deviation for systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) with the proposed method against reference are 4.04 ± 5.81, 2.29 ± 3.55, and 2.46 ± 3.58 mmHg, respectively; the correlation coefficients of SBP, DBP, and MAP are 0.96, 0.92, and 0.94, respectively, which meet the Association for the Advancement of Medical Instrumentation standard and reach A level of the British Hypertension Society standard. This study provides insights into the improvement of accuracy and efficiency of a continuous BP estimation method with a simple structure and without calibration. The proposed algorithm for BP estimation could potentially enable continuous BP monitoring by mobile health devices.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA