Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Circulation ; 105(22): 2588-91, 2002 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-12045161

RESUMO

BACKGROUND: A lifetime mechanical solution for advanced heart failure must be reliable, with a low risk of life-threatening complications. After extensive laboratory testing, we began clinical trials with an axial flow pump for long-term treatment of New York Heart Association class IV, transplant-ineligible patients. METHODS AND RESULTS: The Jarvik 2000 is a continuous flow device that is implanted in the apex of the left ventricle with offloading to the descending thoracic aorta. Skull-based percutaneous power delivery was derived from cochlear implant technology. We used this system in 4 patients with end-stage dilated cardiomyopathy. Exercise capacity, quality of life, device parameters, and native heart function were monitored serially. One patient died from right heart failure at 3 months. The other patients were discharged from hospital between 3 and 8 weeks postoperatively and are currently New York Heart Association I or II. Follow-up lasted between 9 and 20 months. There has been no device failure or hemolysis. Native heart function and quality of life were markedly improved. CONCLUSIONS: The Jarvik 2000 is a true assist (rather than replacement) device that functions synergistically with the native left ventricle and provides excellent quality of life. Adverse events are infrequent. This blood pump may provide a mechanical solution for end-stage heart failure in the community.


Assuntos
Cardiomiopatia Dilatada/terapia , Insuficiência Cardíaca/terapia , Coração Auxiliar , Disfunção Ventricular/terapia , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Peso Corporal , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Cardiomiopatia Dilatada/complicações , Ecocardiografia , Desenho de Equipamento , Tolerância ao Exercício , Seguimentos , Insuficiência Cardíaca/complicações , Testes de Função Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Coração Auxiliar/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Qualidade de Vida , Recuperação de Função Fisiológica , Taxa de Sobrevida , Trombose/prevenção & controle , Tempo , Resultado do Tratamento , Disfunção Ventricular/complicações
3.
Eur J Cardiothorac Surg ; 22(1): 95-100, 2002 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12103380

RESUMO

Stentless glutaraldehyde-preserved bioprosthetic valves for the aortic position were introduced into clinical practice in 1988. Their introduction coincided with the publication of several long-term observational studies of aortic homografts, which showed superior freedom from structural valve damage compared to the first generation stented porcine bioprosthesis. There followed 10 years of intensive investigation into the haemodynamic characteristics of stentless valves. These studies have demonstrated superior haemodynamic features in terms of transvalvular pressure gradients, effective orifice area, and more complete regression of left ventricular hypertrophy. Despite these advantages, stentless valves have yet to be adopted widely. This review seeks to explain this paradox.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Humanos , Hipertrofia Ventricular Esquerda/fisiopatologia , Desenho de Prótese , Medição de Risco , Resultado do Tratamento , Função Ventricular Esquerda
5.
Int J Cardiol ; 129(2): 210-5, 2008 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-17904666

RESUMO

BACKGROUND AND AIMS: Long-term competence of any aortic prosthesis is critical to its clinical durability. Bioprosthetic valves, and in particular the stentless type have been proposed to offer superior haemodynamic profiles with consequent potential for superior left-ventricular mass regression. These benefits however are balanced by the potential longevity of the implanted valve. The aims of this study were to assess medium-term Toronto aortic valve function and its effect on left-ventricular function. METHODS: Between 1992 and 1996 86 patients underwent Toronto aortic valve replacement for aortic valve disease and were followed up annually. Prospectively collected data was analyzed for all patients where detailed echocardiographic follow-up was available. Echocardiographic studies were analyzed at 2+/-0.6 and 6+/-1.4 years after valve replacement. Data collected included left-ventricular systolic and diastolic dimensions, fractional shortening and left-ventricular mass. In addition, data on aortic valve and root morphology, peak aortic velocities, time velocity integral, stroke volume and the mechanism of valve failure where relevant, were also collected. RESULTS: Complete echocardiographic data were available for eighty-four patients, age 69+/-9 years, 62 male. Additional coronary artery bypass grafting was performed in 38% of patients. Twelve (14%) valves had failed during follow-up, 7 (8%) requiring re-operation. Valve failure was associated with morphologically bicuspid native aortic valve (9/12), and progressive dilatation of the aortic sinuses, sino-tubular junction and ascending aorta (11/12). Left-ventricular mass index remained high (184+/-75 g/m(2)) and did not continue to regress between early and medium-term follow-up (175.8+/-77 g/m(2)). CONCLUSIONS: Although more than 90% of implanted Toronto aortic valves remained haemodynamically stable with low gradient at medium-term follow-up, young age and larger aortic dimensions in patients with valve failure suggest better outcome if used in the elderly with normal aortic root geometry.


Assuntos
Valva Aórtica/cirurgia , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Função Ventricular Esquerda , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Progressão da Doença , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/patologia , Hemodinâmica , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA