Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Sex Med ; 20(11): 1353-1358, 2023 10 31.
Artigo em Inglês | MEDLINE | ID: mdl-38324457

RESUMO

BACKGROUND: Penile prosthesis (PP)-induced impending erosion is a rare complication that has not been well characterized. AIM: This study evaluates the role of prosthesis sizing and of the safety of xenograft windsock repair (AlloDerm, Tutoplast, ArthroFLEX) of impending erosion. METHODS: This was a retrospective review of xenograft use during inflatable penile prosthesis (IPP) replacement. Patient demographics, prior PP characteristics, and xenograft-augmented IPP characteristics were obtained. Paired-samples t tests were used to compare the PP cylinder size, rear tip extender size, and calculated PP length between the most recent prior PP and the xenograft-augmented IPP. Complications and follow-up data were obtained. OUTCOMES: The primary outcome was comparing the corporal body and device measurements between the PP presenting with impending erosion and the implanted xenograft-augmented IPP. The secondary outcome was evaluating the incidence of subsequent explantation. RESULTS: A total of 24 patients underwent xenograft repair with simultaneous IPP replacement from 2012 to 2022. The median number of prior PP was 1 (interquartile range, 1-2.75). The median time between the most recent prior PP and xenograft-augmented IPP placement was 21 (interquartile range, 14-79) months. The prior PP was significantly longer at the time of explantation compared with the measured corporal body length in both the left (21.4 cm vs 20.1 cm; P < .01) and right (21.4 cm vs 20.1 cm; P < .01) sides. However, there was no significant difference in length between the xenograft-augmented IPP length at the time of implantation and measured corporal body length in both the left (20.1 cm vs 20.0 cm; P = .67) and right (20.2 cm vs 20.1 cm; P = .56) sides. A total of 16 (66.7%) cases required bilateral xenograft corporal body use. Only 1 (4.2%) patient had an IPP infection requiring explantation within 90 days of xenograft-augmented IPP placement. A total of 2 (8.3%) patients had device malfunction and 1 (4.2%) patient had impending erosion recurrence requiring removal/replacement of their initial xenograft-augmented IPP in a median time of 56 months from placement. CLINICAL IMPLICATIONS: PP oversizing may increase risk of PP-induced impending erosion, which is a delayed process. STRENGTHS AND LIMITATIONS: This is the largest retrospective study of xenograft use during IPP replacement for impending erosion but does not have a control cohort. This study is limited by its retrospective nature, limited follow-up, and absence of a treatment comparison. CONCLUSION: PP-induced impending erosion may be due to PP oversizing but can be successfully repaired with xenograft windsock during simultaneous IPP replacement.


Assuntos
Disfunção Erétil , Doenças do Pênis , Implante Peniano , Prótese de Pênis , Humanos , Masculino , Prótese de Pênis/efeitos adversos , Disfunção Erétil/etiologia , Estudos Retrospectivos , Xenoenxertos , Doenças do Pênis/cirurgia , Implante Peniano/efeitos adversos , Satisfação do Paciente
2.
Cancers (Basel) ; 16(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38473362

RESUMO

Kidney-sparing management for upper tract urothelial carcinoma (UTUC) has become more common but is still most limited by inaccurate histopathologic diagnosis [...].

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA