Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
MAGMA ; 32(5): 599-605, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31073867

RESUMO

PURPOSE: To evaluate the technical and clinical utility of a fully MRI-compatible, pneumatically driven remote-controlled manipulator (RCM) for targeted biopsies of the prostate at 1.5 T. MATERIALS AND METHODS: The data of the first 22 patients that were biopsied under robotic assistance were analyzed. Interventional planning relied on T2-weighted (T2w) turbo spin-echo (TSE) images (axial and sagittal) with a high-b-value diffusion-weighted acquisition added in selected cases. Alignment of the needle guide was controlled with a short balanced SSFP sequence in two oblique planes along the MR-visible sheath. Signals were acquired with a combination of elements from a 30-channel body and a 32-channel spine coil. Biopsy samples were taken with a fully automatic 18-G biopsy gun with a length of 150 or 175 mm. RESULTS: Mean age was 66.6 years and average PSA level was 11.5 ng/ml. Fourteen out of 22 patients (63%) had received prior biopsies under transrectal ultrasound guidance. Diagnostic MRI reports (before biopsy) involved 17 cases with a single suspicious finding (four PI-RADS 3, one PI-RADS 3-4, eight PI-RADS 4 and nine PI-RADS 5 cases). The median effective procedure time was 33.9 (range 25.0-55.9) min for 16 cases with one CSR and 63.4 (52.7-81.8) min for 5 cases with two CSRs. The biopsy with three CSRs took 74.0 min. Histopathologic examination revealed prostate cancer in 14 of 22 cases. CONCLUSION: MR-targeted, transrectal biopsy of the prostate could be reliably performed with a robotic manipulator at a field strength of 1.5 T. Balanced SSFP imaging is considered a viable option for fast procedural control. Follow-up work needs to evaluate to what extent in-bore adjustments and workflow enhancements will contribute to shorter procedure times or higher patient comfort.


Assuntos
Biópsia/métodos , Imagem por Ressonância Magnética Intervencionista , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Procedimentos Cirúrgicos Robóticos/métodos , Idoso , Imagem de Difusão por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Movimento (Física) , Reconhecimento Automatizado de Padrão , Próstata/patologia , Neoplasias da Próstata/patologia , Estudos Retrospectivos , Robótica
3.
BMC Med Imaging ; 19(1): 32, 2019 04 27.
Artigo em Inglês | MEDLINE | ID: mdl-31029093

RESUMO

BACKGROUND: The goal of our study was to evaluate the current approach in prediction of postoperative major complications after pancreaticoduodenectomy (PD), especially symptomatic pancreatic fistula (POPF), using parameters derived from computed tomography (CT). METHODS: Patients after PD were prospectively collected in a database of the local department of surgery and all patients with CT scans available were assessed in this study. CT parameters were measured at the level of the intervertebral disc L3/L4 and consisted of the areas of the visceral adipose tissue (AVAT), the diameters of the pancreatic parenchyma (DPP) and the pancreatic duct (DPD), the areas of ventral abdominal wall muscle (AMVEN), psoas muscle (AMPSO), paraspinal muscle (AMSPI), total muscle (AMTOT), as well as the mean muscle attenuation (MA) and skeletal muscle index (SMI). Mann-Whitney-U Test for two independent samples and binary logistic regression were used for statistical analysis. RESULTS: One hundred thirty-nine patients (55 females, 84 males) were included. DPD was 2.9 mm (Range 0.7-10.7) on median and more narrow in patients with complications equal to or greater stadium IIIb (p < 0.04) and severe POPF (p < 0.01). DPP median value was 17 (6.9-37.9) mm and there was no significant difference regarding major complications or POPF. AVAT showed a median value of 127.5 (14.5-473.0) cm2 and was significantly larger in patients with POPF (p < 0.01), but not in cases of major complications (p < 0.06). AMPSO, AMSPI, AMVEN and AMTOT showed no significant differences between major complications and POPF. MA was both lower in groups with major complications (p < 0.01) and POPF (p < 0.01). SMI failed to differentiate between patients with or without major complications or POPF. CONCLUSION: Besides the known factors visceral obesity and narrowness of the pancreatic duct, the mean muscle attenuation can easily be examined on routine preoperative CT scans and seems to be promising parameter to predict postoperative complications and POPF.


Assuntos
Fístula Pancreática/diagnóstico por imagem , Pancreaticoduodenectomia/efeitos adversos , Complicações Pós-Operatórias/diagnóstico por imagem , Sarcopenia/diagnóstico por imagem , Idoso , Feminino , Humanos , Disco Intervertebral/diagnóstico por imagem , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Fístula Pancreática/mortalidade , Complicações Pós-Operatórias/mortalidade , Estudos Prospectivos , Sarcopenia/etiologia , Sarcopenia/mortalidade , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X
4.
Surg Radiol Anat ; 41(12): 1425-1432, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31563970

RESUMO

PURPOSE: A fracture or a pseudarthrosis of the processus anterior calcanei (PAC) as well as a traumatized Os calcaneus secundarius (OCS) is often overlooked. A clinical or conventional radiological differentiation of these is uncertain. Therefore, a CT scan is recommended. The aim of the study was to identify CT morphological differentiators between OCS and pathologies of PAC. METHODS: All CT scans at our trauma center level I from 2010 to 2014, which imaged the entire foot, performed after acute trauma or postoperative control were retrospectively re-examined for OCS, other accessory ossicles (oAOS), fracture or pseudarthrosis of PAC and analyzed for specifiers. RESULTS: In 611 CT examinations, 14 (2.3%) accessory ossicles (AOS) at the PAC were detected. 12 (86%) were identified as typical OCS and 2 (14%) as oAOS. 56 (9.2%) pathologies were detected. Of these, 44 (79%) were declared as fractures and 12 (21%) as pseudarthrosis. 7 OCS (58%) and 25 (46%) of the pathologies were not mentioned in the initial CT reports. The main differentiators of OCS to fracture of PAC were the anteromedial localization into a concave notch at the calcaneal facet at PAC and the continuous corticalization. With increasing size, radiological osteoarthritic signs at the OCS were frequent (p ≤ 0.05). CONCLUSIONS: The study confirms that AOS or pathologies at the PAC often are not exactly described in CT report. In the context of foot trauma, attention should be paid to this region. Based on the presented differentiation criteria, a precise distinction can be made with the help of a CT.


Assuntos
Variação Anatômica , Calcâneo/anormalidades , Fraturas Ósseas/diagnóstico por imagem , Pseudoartrose/diagnóstico por imagem , Adolescente , Adulto , Idoso , Calcâneo/diagnóstico por imagem , Calcâneo/lesões , Diagnóstico Diferencial , Feminino , Fraturas Ósseas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Pseudoartrose/cirurgia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
5.
Blood Purif ; 46(1): 70-76, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29672277

RESUMO

BACKGROUND/AIMS: The position of the tip of tunnelled haemodialysis (HD) catheters (THC) might influence flow characteristics during HD. In chest X-ray (CXR), carina-related landmarks may be practicable to verify the THC position, and tip-carina distance (TCD) might be useful to predict early-flow dysfunctions. METHODS: In this single-centre, retrospective study, the TCD and the angle between the distal catheter and the body vertical axis (tip-body vertical-angle [TVA]) was measured in 115 THC by post-procedure CXR with 2 investigators. The parameters were proved to be feasible by interrater-reliability and correlated with the incidence of flow-dysfunction within 10 days after insertion. RESULTS: Steep-aligned (TVA <40°, p < 0.01) and deep-ending catheters (TCD: right-sighted >1.5 cm or left-sighted >4.5 cm below the carina; p < 0.01) showed a significantly less dysfunction with a good interrater-reliability (R[TVA] = 0.8, R[TCD] = 0.9). CONCLUSIONS: Carina-related landmarks in CXR might be helpful to predict early-flow dysfunctions. However, randomized studies will be necessary to confirm this in fluoroscopic-guided placement during the insertion of THC.


Assuntos
Cateteres Venosos Centrais/normas , Radiografia Torácica/métodos , Diálise Renal/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Estudos Retrospectivos , Reologia
6.
Radiology ; 283(2): 469-477, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27775896

RESUMO

Purpose To compare single-shot echo-planar diffusion-weighted imaging-derived apparent diffusion coefficient (ADC) maps with fat-saturated (FS) proton density (PD)-weighted turbo spin-echo (TSE) imaging in the detection of bone marrow lesions (BMLs) after knee trauma. Materials and Methods Institutional review board approval was obtained from Leipzig University. Written informed consent was waived. Three radiologists retrospectively re-examined 97 consecutive patients with reported knee trauma who underwent 1.5-T magnetic resonance (MR) imaging within 90 days of knee trauma. The following sequences were used: (a) sagittal T1-weighted TSE and FS PD-weighted TSE and (b) sagittal T1-weighted TSE and single-shot echo-planar diffusion-weighted imaging-derived ADC mapping. BMLs on the lateral and medial femoral condyle, lateral and medial aspect of the tibial plateau, and patella were documented. Volumetry was performed on BMLs with a thickness of at least 15 mm (major BMLs). ADC values were measured in intact bone marrow and major BMLs. A McNemar test and t tests were used as appropriate to test for significant differences between BML number and volume at an α level of .05. Results Significantly more patients showed at least one BML on ADC maps (98%, 95 of 97 patients) than on FS PD-weighted TSE images (86%, 84 of 97 patients) (P < .001). Of the affected regions detected on FS PD-weighted TSE images, 97% (170 of 175 regions) were identified consistently on ADC maps. Only 58% of the affected regions detected on ADC maps (170 of 293 regions) were identified on FS PD-weighted TSE images (P < .001). Median volume of concordant major BML was approximately two times larger on ADC maps (81 cm3) than on FS PD-weighted TSE images (39 cm3) (P < .001). The ADC values of intact bone marrow and BMLs did not overlap. Conclusion ADC maps are more sensitive than corresponding FS PD-weighted TSE images for detection of BML after knee trauma and allow detection of significantly more and larger BMLs. ADC map evaluation improves diagnostic performance in regions with insufficient spectral fat saturation, such as the patella. © RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Doenças da Medula Óssea/diagnóstico por imagem , Densitometria/métodos , Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Traumatismos do Joelho/diagnóstico por imagem , Tecido Adiposo/patologia , Adolescente , Adulto , Doenças da Medula Óssea/etiologia , Feminino , Humanos , Traumatismos do Joelho/complicações , Masculino , Espectroscopia de Prótons por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
7.
J Biol Chem ; 290(23): 14518-27, 2015 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-25897077

RESUMO

Oxidative folding, the process by which proteins fold and acquire disulfide bonds concurrently, is of critical importance for a wide range of biological processes. Generally, this process is catalyzed by oxidoreductase enzymes that facilitate oxidation and also bear chaperone functionality. Although this process has been well described qualitatively, fine yet important details remain obscured by a limited quantitative perspective, arising from the limitations in the application of bulk biochemical methods to the study of oxidative folding. In this work, we have applied single molecule force spectroscopy techniques to monitor in real time the process of oxidative folding as catalyzed by DsbA, the enzyme solely responsible for the catalysis of oxidative folding in the bacterial periplasm. We provide a quantitative and detailed description of the catalytic mechanism utilized by DsbA that offers insight into the entire sequence of events that occurs in the periplasm from the unfolded-reduced state to the folded-oxidized protein. We have compared our results with those of protein disulfide-isomerase, the eukaryotic counterpart of DsbA, allowing us to devise a general mechanism for oxidative folding that also reflects upon the physiological functions and demands of these enzymes in vivo.


Assuntos
Proteínas de Escherichia coli/química , Escherichia coli/química , Isomerases de Dissulfetos de Proteínas/química , Dobramento de Proteína , Escherichia coli/metabolismo , Proteínas de Escherichia coli/metabolismo , Microscopia de Força Atômica , Oxirredução , Isomerases de Dissulfetos de Proteínas/metabolismo
8.
Eur Radiol ; 26(8): 2462-70, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26563349

RESUMO

OBJECTIVES: To evaluate clinical effectiveness and diagnostic efficiency of a navigation device for MR-guided biopsies of focal liver lesions in a closed-bore scanner. METHODS: In 52 patients, 55 biopsies were performed. An add-on MR navigation system with optical instrument tracking was used for image guidance and biopsy device insertion outside the bore. Fast control imaging allowed visualization of the true needle position at any time. The biopsy workflow and procedure duration were recorded. Histological analysis and clinical course/outcome were used to calculate sensitivity, specificity and diagnostic accuracy. RESULTS: Fifty-four of 55 liver biopsies were performed successfully with the system. No major and four minor complications occurred. Mean tumour size was 23 ± 14 mm and the skin-to-target length ranged from 22 to 177 mm. In 39 cases, access path was double oblique. Sensitivity, specificity and diagnostic accuracy were 88 %, 100 % and 92 %, respectively. The mean procedure time was 51 ± 12 min, whereas the puncture itself lasted 16 ± 6 min. On average, four control scans were taken. CONCLUSIONS: Using this navigation device, biopsies of poorly visible and difficult accessible liver lesions could be performed safely and reliably in a closed-bore MRI scanner. The system can be easily implemented in clinical routine workflow. KEY POINTS: • Targeted liver biopsies could be reliably performed in a closed-bore MRI. • The navigation system allows for image guidance outside of the scanner bore. • Assisted MRI-guided biopsies are helpful for focal lesions with a difficult access. • Successful integration of the method in clinical workflow was shown. • Subsequent system installation in an existing MRI environment is feasible.


Assuntos
Biópsia por Agulha/métodos , Biópsia Guiada por Imagem/métodos , Neoplasias Hepáticas/diagnóstico , Fígado/patologia , Imagem por Ressonância Magnética Intervencionista/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Sensibilidade e Especificidade
9.
Acta Radiol ; 57(7): 869-77, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26329683

RESUMO

BACKGROUND: Imaging of cervical carcinoma remains challenging as local infiltration of surrounding tissues cannot always be discriminated safely. New imaging techniques, like diffusion-weighted imaging (DWI) have emerged, which could lead to a more sensitive tumor detection. PURPOSE: To evaluate the benefits of DWI for determination of size, local infiltration, and tumor grading, in patients with primary and recurrent cervical cancer. MATERIAL AND METHODS: In this prospective, study we enrolled 50 patients with primary (n = 35) and recurrent (n = 15) tumors. All patients underwent 3T magnetic resonance imaging (MRI) including conventional (e.g. T1/T2 ± fs ± contrast) sequences and DWI (b-values of 0, 50, 400, 800 s/mm(2)). All images were analyzed by three readers with different experience levels (1, 3, 6 years), who compared image quality, tumor delineation, dimensions, local infiltration, lymph node involvement, and quantified ADC values compared to the histopathological grading. RESULTS: Additional use of DWI resulted in significantly better (P < 0.001) tumor delineation for the least experienced reader, but not for experienced readers. Tumor dimensions were assessed almost equally (P > 0.05) in conventional sequences and DWI. Use of DWI led to an increase in sensitivity of infiltrated adjacent tissue (from 86% to 90%) and detection of lymph node metastases (from 47% to 67%). Quantitative assessment of carcinomas showed lower ADC values (P < 0.001) with significant inverse correlations between different grading levels. CONCLUSION: Our study demonstrates the overall benefits using DWI in 3T MRI resulting in a higher reader confidence, sensitivity of tissue infiltration, and tumor-grading for cervical cancer.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Metástase Linfática/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Gradação de Tumores , Invasividade Neoplásica/diagnóstico por imagem , Estudos Prospectivos , Sensibilidade e Especificidade , Neoplasias do Colo do Útero/patologia
10.
J Biol Chem ; 289(39): 26722-26732, 2014 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-25096579

RESUMO

Neurodegenerative diseases share a common characteristic, the presence of intracellular or extracellular deposits of protein aggregates in nervous tissues. Amyotrophic Lateral Sclerosis (ALS) is a severe and fatal neurodegenerative disorder, which affects preferentially motoneurons. Changes in the redox state of superoxide dismutase 1 (SOD1) are associated with the onset and development of familial forms of ALS. In human SOD1 (hSOD1), a conserved disulfide bond and two free cysteine residues can engage in anomalous thiol/disulfide exchange resulting in non-native disulfides, a hallmark of ALS that is related to protein misfolding and aggregation. Because of the many competing reaction pathways, traditional bulk techniques fall short at quantifying individual thiol/disulfide exchange reactions. Here, we adapt recently developed single-bond chemistry techniques to study individual disulfide isomerization reactions in hSOD1. Mechanical unfolding of hSOD1 leads to the formation of a polypeptide loop held by the disulfide. This loop behaves as a molecular jump rope that brings reactive Cys-111 close to the disulfide. Using force-clamp spectroscopy, we monitor nucleophilic attack of Cys-111 at either sulfur of the disulfide and determine the selectivity of the reaction. Disease-causing mutations G93A and A4V show greatly altered reactivity patterns, which may contribute to the progression of familial ALS.


Assuntos
Esclerose Lateral Amiotrófica/enzimologia , Cisteína/química , Dissulfetos/química , Mutação de Sentido Incorreto , Desdobramento de Proteína , Superóxido Dismutase/química , Substituição de Aminoácidos , Esclerose Lateral Amiotrófica/genética , Cisteína/genética , Humanos , Oxirredução , Estrutura Secundária de Proteína , Superóxido Dismutase/genética , Superóxido Dismutase-1
11.
NMR Biomed ; 28(5): 583-90, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25808071

RESUMO

The quantification of visceral adipose tissue (VAT) is increasingly being considered for risk assessment and treatment monitoring in obese patients, but is generally time-consuming. The goals of this work were to semi-automatically segment and quantify VAT areas of MRI slices at previously proposed anatomical landmarks and to evaluate their predictive power for whole-abdominal VAT volumes on a relatively large number of patients. One-hundred and ninety-seven overweight to severely obese patients (65 males; body mass index, 33.3 ± 3.5 kg/m(2); 132 females; body mass index, 34.3 ± 3.2 kg/m(2)) underwent MRI examination. Total VAT volumes (VVAT-T ) of the abdominopelvic cavity were quantified by retrospective analysis of two-point Dixon MRI data (active-contour segmentation, visual correction and histogram analysis). VVAT-T was then compared with VAT areas determined on one or five slices defined at seven anatomical landmarks (lumbar intervertebral spaces, umbilicus and femoral heads) and corresponding conversion factors were determined. Statistical measures were the coefficients of variation and standard deviations σ1 and σ5 of the difference between predicted and measured VAT volumes (Bland-Altman analysis). VVAT-T was 6.0 ± 2.0 L (2.5-11.2 L) for males and 3.2 ± 1.4 L (0.9-7.7 L) for females. The analysis of five slices yielded a better agreement than the analysis of single slices, required only a little extra time (4 min versus 2 min) and was substantially faster than whole-abdominal assessment (24 min). Best agreements were found at intervertebral spaces L3-L4 for females (σ5/1 = 523/608 mL) and L2-L3 for males (σ5/1 = 613/706 mL). Five-slice VAT volume estimates at the level of lumbar disc L3-L4 for females and L2-L3 for males can be obtained within 4 min and were a reliable predictor for abdominopelvic VAT volume in overweight to severely adipose patients. One-slice estimates took only 2 min and were slightly less accurate. These findings may contribute to the implementation of analytical methods for fast and reliable (routine) estimation of VAT volumes in obese patients.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Gordura Intra-Abdominal/patologia , Obesidade Mórbida/patologia , Sobrepeso/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos/patologia , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Acta Radiol ; 56(1): 121-8, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24504488

RESUMO

BACKGROUND: Clinical management of prostate cancer increasingly aims to distinguish aggressive types that require immediate and radical treatment from indolent tumors that are candidates for watchful waiting. This requires reliable and reproducible parameters to effectively control potential cancer progression. Magnetic resonance imaging (MRI) may provide a non-invasive means for this purpose. PURPOSE: To assess the value of diffusion-weighted imaging and proton MR spectroscopy for the prediction of prostate cancer (PCa) aggressiveness. MATERIAL AND METHODS: In 39 of 64 consecutive patients who underwent endorectal 3-T MRI prior to radical prostatectomy, prostate specimens were analyzed as whole-mount step sections. Apparent diffusion coefficient (ADC), normalized ADC (nADC: tumor/healthy tissue), choline/citrate (CC), and (choline + creatine)/citrate (CCC) ratios were correlated with Gleason scores (GS) from histopathological results. The power to discriminate low (GS ≤ 6) from higher-risk (GS ≥ 7) tumors was assessed with receiver operating characteristics (area under the curve [AUC]). Resulting threshold values were used by a blinded reader to distinguish between aggressive and indolent tumors. RESULTS: Ninety lesions (1 × GS = 5, 41 × GS = 6, 36 × GS = 7, 12 × GS = 8) were considered. nADC (AUC = 0.90) showed a higher discriminatory power than ADC (AUC = 0.79). AUC for CC and CCC were 0.73 and 0.82, respectively. Using either nADC < 0.46 or CCC > 1.3, as well as both criteria for aggressive PCa, the reader correctly identified aggressive and indolent tumors in 31 (79%), 28 (72%), and 33 of 39 patients (85%), respectively. Predictions of tumor aggressiveness from TRUS-guided biopsies were correct in 27 of 36 patients (75%). CONCLUSION: The combination of a highly sensitive normalized ADC with a highly specific CCC was found to be well suited to prospectively estimate PCa aggressiveness with a similar diagnostic accuracy as biopsy results.


Assuntos
Biomarcadores Tumorais/análise , Colina/análise , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Neoplasias da Próstata/química , Neoplasias da Próstata/diagnóstico , Espectroscopia de Prótons por Ressonância Magnética/métodos , Idoso , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Invasividade Neoplásica , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Skeletal Radiol ; 44(7): 995-1000, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25916616

RESUMO

OBJECTIVE: Diffusion-weighted imaging (DWI) provides essential information regarding tumor composition, such as cellularity and/or perfusion. DWI is helpful in distinguishing between malignant and benign lesions. Malignant intramuscular/soft tissue lesions consist of a wide spectrum of tumors that have different cell counts and matrix. It is presumed that these different tumors have different DWI findings and have different apparent diffusion coefficient (ADC) values. The aim of this study was to analyze DWI findings of different intramuscular malignancies in a multicentric study by using a standardized DWI protocol, and to compare the ADC values acquired. MATERIALS AND METHODS: The data banks of four radiology departments were screened retrospectively for malignant intramuscular tumors. Only lesions that were investigated by MRI (with a 1.5-T scanner) using DWI (multishot EPI sequence with b values of 0 and 1,000 s/mm(2)) were included in the study. Overall, 51 patients (28 women, 23 men; mean age 58.8 ± 16.1 years) with 57 different malignant intramuscular lesions were collected. In every case apparent diffusion constant (ADC) maps were calculated. In 14 patients muscle lymphoma, 11 patients intramuscular metastases from different primary tumors, and in 26 cases several muscle sarcomas were identified. RESULTS: The mean ADC value of the estimated lesions was 1.24 ± 0.53 × 10(-3) mm(2)s(-1), median value, 1.11 × 10(-3) mm(2)s(-1), range, 0.54-2.9 × 10(-3) mm(2)s(-1). The mean ADC value in muscle metastases was 1.28 ± 0.24 × 10(-3) mm(2)s(-1), in muscle lymphoma 0.76 ± 0.14 × 10(-3) mm(2)s(-1), and in muscle sarcomas 1.82 ± 0.63 × 10(-3) mm(2)s(-1). Muscle lymphoma showed statistically significant lower ADC values in comparison to muscle metastases (p = 0.01) and muscle sarcoma (p = 0.001). There was no significant differences between ADC values in muscle metastases and sarcomas (p = 0.48). ADC values in muscle lymphoma were homogeneous with less inter-patient variability and were within a relatively close range. Muscle sarcomas had a broad range of ADC values. CONCLUSION: Intramuscular malignant lesions had different ADC values on DWI. 22.8% of the tumors analyzed had low ADC values, 26.3% moderate, and 50.9% high ADC values. Muscle lymphoma had statistically significantly lower ADC values in comparison to muscle metastases and sarcomas. Muscle sarcomas presented with a broad range of ADC values.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Neoplasias Musculares/patologia , Músculo Esquelético/patologia , Feminino , Humanos , Aumento da Imagem/métodos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
NMR Biomed ; 27(9): 1123-8, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25066754

RESUMO

Subcutaneous (SAT) and visceral adipose tissue (VAT) differ in composition, endocrine function and localization in the body. VAT is considered to play a role in the pathogenesis of insulin resistance, type 2 diabetes, fatty liver disease, and other obesity-related disorders. It has been shown that the amount, distribution, and (cellular) composition of adipose tissue (AT) correlate well with metabolic conditions. In this study, T1 relaxation times of AT were measured in severely obese subjects and compared with those of healthy lean controls. Here, we tested the hypothesis that T1 relaxation times of AT differ between lean and obese individuals, but also between VAT and SAT as well as superficial (sSAT) and deep SAT (dSAT) in the same individual. Twenty severely obese subjects (BMI 41.4 ± 4.8 kg/m(2) ) and ten healthy lean controls matched for age (BMI 21.5 ± 1.9 kg/m(2) ) underwent MRI at 1.5 T using a single-shot fast spin-echo sequence (short-tau inversion recovery) at six different inversion times (TI range 100-1000 ms). T1 relaxation times were computed for all subjects by fitting the TI -dependent MR signal intensities of user-defined regions of interest in both SAT and VAT to a model function. T1 times in sSAT and dSAT were only measured in obese patients. For both obese patients and controls, the T1 times of SAT (275 ± 14 and 301 ± 12 ms) were significantly (p < 0.01) shorter than the respective values in VAT (294 ± 20 and 360 ± 35 ms). Obese subjects also showed significant (p < 0.01) T1 differences between sSAT (268 ± 11 ms) and dSAT (281 ± 19 ms). More important, T1 differences in both SAT and VAT were highly significant (p < 0.001) between obese patients and healthy subjects. The results of our pilot study suggest that T1 relaxation times differ between severely obese patients and lean controls, and may potentially provide an additional means for the non-invasive assessment of AT conditions and dysfunction.


Assuntos
Tecido Adiposo/patologia , Adiposidade , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Obesidade Mórbida/patologia , Adulto , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
NMR Biomed ; 26(11): 1412-9, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23801556

RESUMO

Signal intensities of T2-weighted magnetic resonance images depend on the local fiber arrangement in hyaline cartilage. The aims of this study were to determine whether angle-sensitive MRI at 7 T can be used to quantify the cartilage ultrastructure of the knee in vivo and to assess potential differences with age. Ten younger (21-30) and ten older (55-76 years old) healthy volunteers were imaged with a T2-weighted spin-echo sequence in a 7 T whole-body MRI. A "fascicle" model was assumed to describe the depth-dependent fiber arrangement of cartilage. The R/T boundary positions between radial and transitional zones were assessed from intensity profiles in small regions of interest in the femur and tibia, and normalized to cartilage thickness using logistic curve fits. The quality of our highly resolved (0.3 × 0.3 × 1.0 mm(3)) MR cartilage images were high enough for quantitative analysis (goodness of fit R(2) = 0.91 ± 0.09). Between younger and older subjects, normalized positions of the R/T boundary, with value 0 at the bone-cartilage interface and 1 at the cartilage surface, were significantly (p < 0.05) different in femoral (0.51 ± 0.12 versus 0.41 ± 0.10), but not in tibial cartilage (0.65 ± 0.11 versus 0.57 ± 0.09, p = 0.119). Within both age groups, differences between femoral and tibial R/T boundaries were significant. Using a fascicle model and angle-sensitive MRI, the depth-dependent anisotropic fiber arrangement of knee cartilage could be assessed in vivo from a single 7 T MR image. The derived quantitative parameter, thickness of the radial zone, may serve as an indicator of the structural integrity of cartilage. This method may potentially be suitable to detect and monitor early osteoarthritis because the progressive disintegration of the anisotropic network is also indicative of arthritic changes in cartilage.


Assuntos
Cartilagem Articular/ultraestrutura , Joelho/anatomia & histologia , Imageamento por Ressonância Magnética , Adulto , Idoso , Feminino , Fêmur/anatomia & histologia , Humanos , Masculino , Pessoa de Meia-Idade , Tíbia/anatomia & histologia , Adulto Jovem
17.
J Magn Reson Imaging ; 37(6): 1480-5, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23055397

RESUMO

PURPOSE: To present a novel method for MR elastography (MRE) of the prostate at 3 Tesla using a modified endorectal imaging coil. MATERIALS AND METHODS: A commercial endorectal coil was modified to dynamically generate mechanical stress (contraction and dilation) in a prostate phantom with embedded phantom "lesions" (6 mm diameter) and in a porcine model. Resulting tissue displacements were measured with a motion-sensitive EPI sequence at actuation frequencies of 50-200 Hz. Maps of shear modulus G were calculated from the measured phase-difference shear-wave patterns. RESULTS: In the G maps of the phantom, "lesions" were easily discernible against the background. The average G values of regions of interest placed in the "lesion" (8.2 ± 1.9 kPa) were much higher than those in the background (3.6 ± 1.4 kPa) but systematically lower than values reported by the vendor (13.0 ± 1.0 and 6.7 ± 0.7 kPa, respectively). In the porcine model, shear waves could be generated and measured shear moduli were substantially different for muscle (7.1 ± 2.0 kPa), prostate (3.0 ± 1.4 kPa), and bulbourethral gland (5.6 ± 1.9 kPa). CONCLUSION: An endorectal MRE concept is technically feasible. The presented technique will allow for simultaneous MRE and MRI acquisitions using a commercial base device with minor, MR-conditional modifications. The diagnostic value needs to be determined in further trials.


Assuntos
Técnicas de Imagem por Elasticidade/instrumentação , Aumento da Imagem/instrumentação , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Próstata/patologia , Próstata/fisiologia , Transdutores , Módulo de Elasticidade/fisiologia , Humanos , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Masculino , Imagens de Fantasmas , Reto/patologia , Reto/fisiologia , Estresse Mecânico
18.
J Magn Reson Imaging ; 37(5): 1144-50, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23124651

RESUMO

PURPOSE: To present software for supervised automatic quantification of visceral and subcutaneous adipose tissue (VAT, SAT) and evaluates its performance in terms of reliability, interobserver variation, and processing time, since fully automatic segmentation of fat-fraction magnetic resonance imaging (MRI) is fast but susceptible to anatomical variations and artifacts, particularly for advanced stages of obesity. MATERIALS AND METHODS: Twenty morbidly obese patients (average BMI 44 kg/m(2) ) underwent 1.5-T MRI using a double-echo gradient-echo sequence. Fully automatic analysis (FAA) required no user interaction, while supervised automatic analysis (SAA) involved review and manual correction of the FAA results by two observers. Standard of reference was provided by manual segmentation analysis (MSA). RESULTS: Average processing times per patient were 6, 6+4, and 21 minutes for FAA, SAA, and MSA (P < 0.001), respectively. For VAT/SAT assessment, Pearson correlation coefficients, mean (bias), and standard deviations of the differences were R = 0.950, +0.003, and 0.043 between FAA and MSA and R = 0.981, +0.009, and 0.027 between SAA and MSA. Interobserver variation and intraclass correlation were 3.1% and 0.996 for SAA, and 6.6% and 0.986 for MSA, respectively. CONCLUSION: The presented supervised automatic approach provides a reliable option for MRI-based fat quantification in morbidly obese patients and was much faster than manual analysis.


Assuntos
Gordura Abdominal/patologia , Adiposidade , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Obesidade Mórbida/patologia , Reconhecimento Automatizado de Padrão/métodos , Software , Adolescente , Adulto , Algoritmos , Feminino , Humanos , Aumento da Imagem/métodos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
19.
Pancreatology ; 13(4): 458-60, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23890148

RESUMO

In some patients with tumors located in the pancreas or in the periampullary region, the decision to perform a surgical resection can be difficult. In patients with concomitant chronic pancreatitis this decision can be even more challenging, since a definitive preoperative differentiation between non-malignant and malignant tumors in many cases is not possible. Clinical symptoms or complications from the tumor often direct a rational treatment strategy. For therapeutic decisions, an interdisciplinary discussion of all diagnostic findings by experienced clinicians is needed. However, in rare cases, like the one presented here, an uncommon non-malignant entity like a periampullary hamartoma may be only diagnosed after surgical resection.


Assuntos
Colestase/diagnóstico por imagem , Obstrução da Saída Gástrica/diagnóstico por imagem , Hamartoma/cirurgia , Pancreatite Crônica/diagnóstico por imagem , Ductos Biliares/cirurgia , Colestase/cirurgia , Duodeno/cirurgia , Obstrução da Saída Gástrica/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Pancreaticojejunostomia , Radiografia
20.
MAGMA ; 26(1): 159-71, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23053713

RESUMO

The implementation of hybrid imaging systems requires thorough and anticipatory planning at local and regional levels. For installation of combined positron emission and magnetic resonance imaging systems (PET/MRI), a number of physical and constructional provisions concerning shielding of electromagnetic fields (RF- and high-field) as well as handling of radionuclides have to be met, the latter of which includes shielding for the emitted 511 keV gamma rays. Based on our experiences with a SIEMENS Biograph mMR system, a step-by-step approach is required to allow a trouble-free installation. In this article, we present a proposal for a standardized step-by-step plan to accomplish the installation of a combined PET/MRI system. Moreover, guidelines for the smooth operation of combined PET/MRI in an integrated research and clinical setting will be proposed. Overall, the most important preconditions for the successful implementation of PET/MRI in an integrated research and clinical setting is the interdisciplinary target-oriented cooperation between nuclear medicine, radiology, and all referring and collaborating institutions at all levels of interaction (personnel, imaging protocols, reporting, selection of the data transfer and communication methods).


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Calibragem , Protocolos Clínicos , Redes de Comunicação de Computadores , Desenho de Equipamento , Arquitetura de Instituições de Saúde , Humanos , Proteção Radiológica , Pesquisa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA