Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
BMC Musculoskelet Disord ; 25(1): 131, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38347547

RESUMO

BACKGROUND: Malignant femoral soft tissue tumors are occasionally resected together with the femoral nerves, but this can cause loss of knee extensor muscle activity. To the best of our knowledge, no previous reports have detailed the gait analysis of such cases in combination with electromyography. Herein, we report the gait analysis of a patient who underwent left groin synovial sarcoma and left femoral nerve resection 12 years ago. CASE PRESENTATION: We analyzed the gait of a 38-year-old man who was able to walk unaided after the resection of a synovial sarcoma in the left groin together with the ipsilateral femoral nerve. The muscle activities of the affected medial (MH) and lateral hamstrings (LH), and lateral heads of the gastrocnemius (GL) were increased during 50-75% of the stance phase. The hip flexion angle of the affected limb was smaller, and the ankle plantar flexion angle of the affected limb was larger than that of the non-affected limb. This means that in the affected limb, the hip and ankle angles were adjusted to prevent knee collapse, and the MH, LH, and GL muscles contributed in the mid- and late-stance phases. Moreover, we found that the hamstring and gastrocnemius of the affected limb worked together to keep the ipsilateral knee extended in the mid-stance phase and slightly flexed in the late-stance phase. CONCLUSIONS: Patients capable of walking after femoral nerve resection may control their hamstrings and gastrocnemius muscles collaboratively to prevent ipsilateral knee collapse in the mid- and late-stance phases.


Assuntos
Sarcoma Sinovial , Sarcoma , Masculino , Humanos , Adulto , Nervo Femoral , Análise da Marcha , Marcha/fisiologia , Caminhada/fisiologia , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Articulação do Joelho/fisiologia , Músculo Esquelético/cirurgia , Músculo Esquelético/fisiologia , Sarcoma/diagnóstico por imagem , Sarcoma/cirurgia , Fenômenos Biomecânicos
2.
Int J Mol Sci ; 25(7)2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38612467

RESUMO

Both bone morphogenetic protein 2 (BMP-2) and abaloparatide are used to promote bone formation. However, there is no consensus about their optimal administration. We investigated the optimal administration theory for the pairing of BMP-2 and abaloparatide in a rat spinal fusion model. Group I was only implanted in carriers and saline. Carriers with 3 µg of recombinant human BMP-2 (rhBMP-2) were implanted in other groups. Abaloparatide injections were administered three times a week for group III (for a total amount of 120 µg/kg in a week) and six times a week for group IV (for a total amount of 120 µg/kg in a week) after surgery. They were euthanized 8 weeks after the surgery, and we explanted their spines at that time. We assessed them using manual palpation tests, radiography, high-resolution micro-computed tomography (micro-CT), and histological analysis. We also analyzed serum bone metabolism markers. The fusion rate in Groups III and IV was higher than in Group I, referring to the manual palpation tests. Groups III and IV recorded greater radiographic scores than those in Groups I and II, too. Micro-CT analysis showed that Tbs. Sp in Groups III and IV was significantly lower than in Group I. Tb. N in Group IV was significantly higher than in Group I. Serum marker analysis showed that bone formation markers were higher in Groups III and IV than in Group I. On the other hand, bone resorption markers were lower in Group IV than in Group I. A histological analysis showed enhanced trabecular bone osteogenesis in Group IV. Frequent administration of abaloparatide may be suitable for the thickening of trabecular bone structure and the enhancement of osteogenesis in a rat spinal fusion model using BMP-2 in insufficient doses.


Assuntos
Osteogênese , Proteína Relacionada ao Hormônio Paratireóideo , Fusão Vertebral , Humanos , Animais , Ratos , Microtomografia por Raio-X , Proteínas Morfogenéticas Ósseas
3.
Arch Orthop Trauma Surg ; 143(7): 4501-4510, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36443614

RESUMO

INTRODUCTION: Few studies have examined the survival rates of total hip arthroplasty (THA) with the same femoral stem, and the predictive factors leading to the revision of stemmed metal-on-metal (MoM) THA remain unknown. We determined the long-term survival rate of stemmed MoM THA compared with that of metal-on-polyethylene (MoP) bearing THA, the effect of head size and cup placement angle on revision rate, and predictors of revision. MATERIALS AND METHODS: A total of 130 hips in 110 patients who underwent primary THA by the same surgeon were included. M2a-RingLoc with a metal-on-polyethylene bearing (group P, 53 hips), M2a-Taper with MoM bearing (group T, 44 hips), and M2a-Magnum with MoM bearing (group M, 33 hips) were used. The mean age at surgery was 63.1 ± 9.5 years, and the mean postoperative follow-up duration was 133.7 ± 39.1 months. Whole blood metal ion concentrations were measured preoperatively and postoperatively, and magnetic resonance imaging was performed to identify aseptic local tissue reactions (ALTRs). Kaplan-Meier survivorship analysis and multiple logistic regression analysis were performed. RESULTS: The THA survival rate up to the maximum postoperative follow-up period was 96.2% at 173 months, 46.6% at 179 months, and 47.8% at 145 months in groups P, T, and M, respectively, with revision as the endpoint. The stemmed MoM THA recorded a very low survival rate (p < 0.001). The ALTR rates were 70.5% and 63.6% in groups T and M, respectively. The risk factor for revision was the use of MoM bearing, and there was no difference in the results based on the head size in group M. Cobalt levels continued to increase postoperatively, although they were not accurate predictors of revision. CONCLUSIONS: Stemmed MoM THA has a very low survival rate and should be used with caution. It is important to monitor the patient's symptoms and perform appropriate imaging to ensure timely revision.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Próteses Articulares Metal-Metal , Humanos , Artroplastia de Quadril/métodos , Taxa de Sobrevida , Reoperação/métodos , Fatores de Risco , Metais , Polietileno , Desenho de Prótese , Falha de Prótese
4.
Med Mol Morphol ; 55(2): 158-165, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35244781

RESUMO

This study aimed to examine the ultrastructure of the arteries of the synovium, acetabular labrum, and ligamentum teres of the hip joint using light, scanning electron, and transmission electron microscopes to identify features of early arteriosclerosis. Tissues collected from three patients (under 40 years of age) with osteonecrosis of the femoral head were immersed in 8 N HCl at 60 °C for 20 min to digest collagen fibers for scanning electron microscopy. Tortuous arterioles and arteries were noted in the joint components, including the synovium, acetabular labrum, and ligamentum teres. The ultrastructure of the arterioles appeared normal; however, intimal thickening was found in most arteries. The thickened intima had abundant elastic fibers and many smooth muscle cells (which were of a synthetic phenotype because they had a few actin filaments and well-developed rough endoplasmic reticulum). This study illustrates that arteriosclerotic changes are present in tortuous arteries in the synovium, acetabular labrum, and ligamentum teres of the hip joint even from a relatively young age and suggests that meandering blood vessels may be the preferred foci of arteriosclerosis.


Assuntos
Arteriosclerose , Articulação do Quadril , Articulação do Quadril/ultraestrutura , Humanos , Microscopia Eletrônica de Varredura
5.
Med Mol Morphol ; 53(3): 183-189, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31932970

RESUMO

We report herein the microstructure of the acetabular labrum obtained from a patient with stem loosening but without bipolar cup migration who had undergone hemiarthroplasty for femoral neck fracture 18 years ago. We used light and scanning electron microscopy to investigate the influence of bipolar cup on acetabular labrum in vivo. Deparaffinized blocks were treated with 2 N NaOH to digest the cell matrix, allowing the collagen fibers, constituting the acetabular labrum, to be observed under scanning electron microscopy. Although chondrocyte atrophy was seen, the basic structure was not different from the normal tissue images of the elderly. However, in the deep part of the acetabular labrum, there was an area that was not stained with Alcian blue observed with light microscopy, and there was an amorphous tissue without type II collagen fibrils observed with scanning electron microscopy. These findings proved that the acetabular labrum has partially degenerated over the long term after bipolar hemiarthroplasty, and that the acetabular labrum can survive in vivo in such a condition. Given that hemiarthroplasty has a possibility to preserve the face-to-face tissue in the long term in vivo, it may be one of the valuable options for modern or future joint reconstruction surgery.


Assuntos
Acetábulo/cirurgia , Hemiartroplastia , Articulação do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Acetábulo/ultraestrutura , Idoso de 80 Anos ou mais , Feminino , Articulação do Quadril/diagnóstico por imagem , Articulação do Quadril/patologia , Articulação do Quadril/ultraestrutura , Humanos
6.
Med Mol Morphol ; 53(1): 21-27, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31144043

RESUMO

The acetabular labrum is frequently damaged with advancing age. As collagen fibers are the main sources of strength, knowledge of their ultrastructure is important to determine the cause of age-induced changes. We aimed to investigate the ultrastructure of collagen fibers constituting the acetabular labrum using scanning electron microscopy (SEM). Acetabular labrum samples obtained during total hip arthroplasty were studied. The samples were specially prepared to observe the steric construction of collagen fibrils constituting the acetabular labrum under light microscopy followed by SEM. The acetabular labrum was mostly composed of cartilage tissue, consisting of chondrocytes and collagen type II, with a layer of collagen type I. In adults, chondrocytes with a rich cytoplasm were surrounded by a dense network of fine type II collagen fibrils, and small bundles of type I collagen fibrils were interposed in the cartilage layer. In elderly individuals, the chondrocytes atrophied and both type I and II collagen fibrils were sparse. We suggest that cartilage has three to five layers, consisting of type I and type II collagen fibrils with a solid cartilage substrate. In elderly individuals, the density of chondrocytes decreases and the cellular shape and architecture of collagen fibrils also changes.


Assuntos
Acetábulo/ultraestrutura , Envelhecimento/patologia , Cartilagem Articular/ultraestrutura , Condrócitos/ultraestrutura , Articulação do Quadril/ultraestrutura , Acetábulo/patologia , Acetábulo/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Envelhecimento/fisiologia , Artroplastia de Quadril/métodos , Cartilagem Articular/patologia , Cartilagem Articular/cirurgia , Colágeno Tipo I/ultraestrutura , Colágeno Tipo II/ultraestrutura , Feminino , Articulação do Quadril/patologia , Articulação do Quadril/cirurgia , Humanos , Imageamento Tridimensional , Masculino , Microscopia Eletrônica de Varredura , Necrose/patologia , Necrose/cirurgia
7.
Med Mol Morphol ; 53(1): 7-14, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31104131

RESUMO

We examined the ultrastructure of the anterior cruciate ligament and assessed age-related changes by comparing the ligaments of young and old monkeys. Ultrathin sections of the anterior cruciate ligament were observed by transmission electron microscopy. The three-dimensional architecture of collagen fibers in the ligament was examined by scanning electron microscopy after tissue specimens were treated with 2 N NaOH to digest the extracellular matrix. At the surface layer of the cruciate ligament in young monkeys, fusiform-shaped fibroblasts actively produced collagen fibrils. The ligament consisted of parallel bundles of dense collagen fibrils of approximately 200 nm in diameter. Collagen fibrils appeared to run linearly. Ligament fibrocytes in the deep layer had a stellate form. Ligament fibrocytes decreased in number and showed marked atrophy in old age. Collagen fibrils had a looser configuration in older monkeys. Despite atrophy of fibroblasts in the deep layer of the anterior cruciate ligament, the area with atrophic fibroblasts in the ligament expands with age, which can likely cause deterioration of and a reduction in collagen fibers. This information can be applied in studies on the cause of the low repair ability of and aging-related changes in the anterior cruciate ligament in humans.


Assuntos
Envelhecimento/fisiologia , Ligamento Cruzado Anterior/ultraestrutura , Colágeno/ultraestrutura , Fibroblastos/ultraestrutura , Articulação do Joelho/ultraestrutura , Animais , Macaca fuscata , Microscopia Eletrônica de Varredura , Microscopia Eletrônica de Transmissão , Microtomia
8.
Eur J Orthop Surg Traumatol ; 28(1): 65-70, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28780593

RESUMO

BACKGROUND: Regarding the cup setting in total hip arthroplasty, range of motion and prevention of dislocation are important. From past reports, the wear of the bearing surface may affect long-term results. This study evaluated the stress applied to the bearing surface by the combined use of the three-dimensional rigid spring model and the finite-element analysis. METHODS: For contact pressure distribution of the bearing surface, interference analysis was performed using a three-dimensional rigid body spring model. Furthermore, stress was applied to the inner surface of the cup installed in the bone so that the same stress distribution obtained from the interference analysis was achieved. The finite-element analysis was then performed at each condition, which changed the inclination and anteversion angles of the cup to examine the relationship of maximum equivalent stress. RESULTS AND DISCUSSION: The maximum equivalent stresses on the bearing surface under the condition with fixation of an anteversion angle of 0° were 0.78, 0.85, and 1.15 MPa at inclination angles of 25°, 40°, and 55°, respectively. The stress value at 55° was approximately 1.5 times greater than that at 25°. The maximum equivalent stresses on the bearing surface under the condition with fixation of an inclination angle of 40° were 0.85, 0.9, and 1.02 MPa at anteversion angles of 0°, 15°, and 30°, respectively. The stress value at 30° was approximately 1.2 times greater than that at 0°. This study suggests that large inclination and anteversion angles may enhance the stress on the bearing surface and affect long-term results.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Pressão , Estresse Mecânico , Artroplastia de Quadril/instrumentação , Simulação por Computador , Módulo de Elasticidade , Análise de Elementos Finitos , Humanos , Suporte de Carga
9.
Arch Orthop Trauma Surg ; 137(3): 425-430, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28150224

RESUMO

INTRODUCTION: In bipolar hemiarthroplasty, migration of the outer cup component into the acetabular cup, with evidence of severe osteolysis in the acetabulum, commonly occurs without loosening of the femoral component. The merits of retaining the stable femoral component in these cases have been debated. Our study aimed to determine whether revision of the acetabular component in isolation could be successfully performed. MATERIALS AND METHODS: The data of 54 patients (61 hips), 44 women, and 10 men, aged 67.7 (range 47-86) years at the time of the index revision, were analyzed. The average time from primary operation to revision surgery was 14.9 (range 1.0-27.0) years, with an average follow-up time after revision of 5.2 (range, 1.0-18.7) years. Indications for acetabular revision included migration of the outer cup component (N = 55), disassembly of the bipolar cup (N = 4), and recurrent dislocation (N = 2). Fixation of the femoral stem was cementless in 49 hips and cemented in 12. Bone grafting for osteolysis of the proximal femur around the stem was performed in six hips. An acetabular reinforcement ring with a cemented cup was used in 31 hips, with cementless cup fixation in 29 hips, and cemented cup in one case. RESULTS: On average, the Harris hip score improved from 57.0 ± 21.6 to 87.4 ± 6.40 points after revision. Two cases of femoral periprosthetic fracture were treated with osteosynthesis 3 year post-revision. There was no evidence of loosening of the femoral stem or subsidence, with a non-progressive radiolucent line <2 mm identified in one case. There was no incidence of dislocation or deep infection, and all components were judged to be stable at the final follow-up. CONCLUSION: Isolated acetabular revision can be reliably performed in cases of failed bipolar hemiarthroplasty with a well-fixed femoral component.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/métodos , Hemiartroplastia , Falha de Prótese , Reoperação/métodos , Idoso , Idoso de 80 Anos ou mais , Transplante Ósseo , Feminino , Fêmur/cirurgia , Seguimentos , Luxação do Quadril/cirurgia , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Osteólise/cirurgia , Fraturas Periprotéticas/epidemiologia , Complicações Pós-Operatórias/epidemiologia
10.
Acta Orthop Belg ; 83(4): 631-640, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30423672

RESUMO

This mechanical study was conducted with the shellcement interface in order to construct an acetabular metal shell, and to fix a polyethylene liner with bone cement. Six types of models were tested, with all cementations performed under similar conditions. The "lever out" test was conducted 3 times for each group in order to measure the dissociation strength. The average dissociation strength values were 11.5 N• m for those without screw holes; 33.6, 34.7, and 78.7 N• m for those with single holes at 1, 3, and 6 mm depth, respectively; and 41.3 and 101.1 N• m for 2 different configurations with 3 holes at 3 mm depth. The strength of adhesion increased with the use of a cement anchor, and with an increasing length and number of anchors. The application of a cement anchor with a screw hole is clinically useful for increasing the mechanical strength of the shellcement interface.


Assuntos
Acetábulo , Prótese Ancorada no Osso , Prótese de Quadril , Desenho de Prótese , Cimentos Ósseos , Humanos , Teste de Materiais , Falha de Prótese
11.
Eur J Orthop Surg Traumatol ; 25(8): 1271-7, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26319002

RESUMO

We verified the index cup position required for bulk bone grafting instead of morcellized grafting immediately after cementless total hip arthroplasty. Three-dimensional finite element analysis was used to evaluate changes in the volume of the slippage of the cup-host bone interface as micro-motion of the cup at the acetabular bone defect site depending on the cup-center-edge (CE) angle. The conditions of bulk bone grafts were similar to those of cortical bone. Slippage increased with decreasing cup-CE angle. A bulk bone graft tightly fixed to the host bone prevented considerably larger slippage between the cup and host bone. A smaller cup-CE angle increased the impact of the bulk bone graft on slippage. When the cup-CE angle was 0° or -10°, the criterion for slippage in favorable initial fixation in all conditions was <40 µm. Even if transplanted bulk bone is used, unless good fixation is obtained between the host bone, and the cup and bone graft, it is impossible to obtain reliable fixation of the cup with a cup-CE angle <-10° and slippage exceeding 40 µm. Bulk bone grafting tightly fixed to the host bone improves initial the cup-host bone fixation, especially when the cup-CE angle is small, such as <-10°. In clinical practice, negative factors are implicated in the initial fixation of various cups, and sufficient fixation between the host bone and cup or bulk bone graft using a screw is effective when the cup-CE angle is extremely small.


Assuntos
Artroplastia de Quadril/métodos , Transplante Ósseo/métodos , Luxação do Quadril/cirurgia , Acetabuloplastia/métodos , Acetábulo/cirurgia , Interface Osso-Implante/fisiologia , Análise de Elementos Finitos , Luxação do Quadril/fisiopatologia , Prótese de Quadril , Humanos , Movimento/fisiologia , Falha de Prótese
12.
Eur J Orthop Surg Traumatol ; 25(3): 489-96, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25421639

RESUMO

INTRODUCTION: In two-stage treatments for infections after total hip arthroplasty, antibiotic-loaded cement spacers help treat the infection by antibiotic elution and prevent contraction. However, such spacers are weak and may fracture while awaiting replacement, impairing functionality. We evaluated whether a Kirschner wire (K-wire) mounted into the spacer reinforced its strength along with the effects of the reinforcing material, position, and intensity. METHODS: Spacers without reinforcing materials constituted the control group. As reinforcing materials, stainless steel K-wires (diameters 3 and 6 mm), titanium alloy and carbon fibers (diameter 3.175 mm), and stainless steel meshes (inner and outer diameters, 6 and 9 mm, respectively) were inserted into the spacer mold before filling with cement. The spacers complied with ISO 7206-4; a compressive load was applied using a testing machine with a velocity of 25.4 mm/min, and the maximum load was recorded. We used 1-3 K-wires positioned on the medial side, lateral side, neck only, and stem only and tested 3 specimens for each condition. RESULTS: The control group withstood the highest load. Stainless steel was the strongest material; 3-mm K-wires in the neck and lateral side withstood a higher load. The computed tomography (CT) imaging revealed a cavity between the K-wires and cement. When K-wires were inserted along the whole length, despite cement fractures, continuity was maintained because of the reinforcing materials. CONCLUSION: It is difficult to improve the reinforcing strength of spacers using K-wires; however, K-wires prevented dislocation of cement spacer fragments, which can help prevent contraction and facilitate spacer removal during replacement.


Assuntos
Cimentos Ósseos , Desenho de Prótese , Infecções Relacionadas à Prótese/cirurgia , Estresse Mecânico , Artroplastia de Quadril/efeitos adversos , Fios Ortopédicos , Carbono , Força Compressiva , Prótese de Quadril/efeitos adversos , Humanos , Teste de Materiais , Falha de Prótese , Infecções Relacionadas à Prótese/etiologia , Reoperação/instrumentação , Aço Inoxidável , Telas Cirúrgicas , Titânio
13.
Eur J Orthop Surg Traumatol ; 25(3): 497-502, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25421640

RESUMO

BACKGROUND: Press-fit and screw fixation are important technical factors to achieve initial stability of a cementless acetabular cup for good clinical results of total hip arthroplasty. However, how these factors affect one another in initial cup fixation remains unclear. Therefore, this study aimed to evaluate the mutual influence between press-fit and screw fixation on initial cup stability. METHODS: Foam bone was subjected to exact hemispherical-shape machining to diameters of 48, 48.5 and 49 mm. A compressive force was applied to ensure seating of a 48-mm-diameter acetabular cup in the foam bone prior to testing. Screws were inserted in six different conditions and tightened in a radial direction at the same torque strength. Then, the socket was rotated with a twist-testing machine, and the torque value at the start of axial rotation between the socket and the foam bone was measured under each screw condition. RESULTS: The torque values for the 48-mm-diameter reaming were >20 N m higher than those for the 48.5- and 49-mm-diameter reaming in each screw condition, indicating that press-fit fixation is stronger than screw fixation. Meanwhile, torque values for the 48.5- and 49-mm-diameter reaming tended to increase with increasing the number of screws. CONCLUSIONS: According to our experiment, press-fit fixation of a cementless acetabular cup achieved rigid stability. Although the supplemental screws increased stability of the implant under good press-fit conditions, they showed little impact on whole-cup stability. In the case of insufficient press-fit fixation, cup stability depends on screw stability and increasing the number of additional screws increases cup stability.


Assuntos
Acetábulo , Parafusos Ósseos , Prótese de Quadril , Ajuste de Prótese , Implantação de Prótese/métodos , Artroplastia de Quadril/métodos , Fenômenos Biomecânicos , Humanos , Teste de Materiais , Implantação de Prótese/instrumentação , Rotação , Torque
14.
Eur J Orthop Surg Traumatol ; 25(5): 877-83, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25749753

RESUMO

We used a three-dimensional finite element method to investigate the conditions behind the Kerboull-type (KT) dome. The KT plate dome was divided into five areas, and 14 models were created to examine different conditions of dome contact with the acetabulum. The maximum stress on the KT plate and screws was estimated for each model. Furthermore, to investigate the impact of the contact area with the acetabulum on the KT plate, a multiple regression analysis was conducted using the analysis results. The dome-acetabulum contact area affected the maximum equivalent stress on the KT plate; good contact with two specific areas of the vertical and horizontal beams (Areas 3 and 5) reduced the maximum equivalent stress. The maximum equivalent stress on the hook increased when the hardness of the bone representing the acetabulum varied. Thus, we confirmed the technical importance of providing a plate with a broad area of appropriate support from the bone and cement in the posterior portion of the dome and also proved the importance of supporting the area of the plate in the direction of the load at the center of the cross-plate and near the hook.


Assuntos
Acetábulo/cirurgia , Placas Ósseas , Parafusos Ósseos , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Fenômenos Biomecânicos , Prótese de Quadril , Humanos , Falha de Prótese , Estresse Mecânico
15.
Eur J Orthop Surg Traumatol ; 25(2): 321-9, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24964969

RESUMO

For total hip arthroplasty or revision surgery using acetabular reinforcement cross-plates, choosing between bulk and morselized bone grafts for filling acetabular defects is challenging. We used finite element model (FEM) analysis to clarify various stresses on the cross-plate based on bone defect size, bone graft type, and presence or absence of hook fixation to the bone. We constructed 12-pattern FEMs and calculated the maximum stress generated on the Kerboull-type (KT) plate and screw. Bone defects were classified into four patterns according to the volume. Regarding the bone graft type, bulk bone grafts were considered as cortical bone, and morselized bone grafts were considered to consist of cancellous bone. Models were compared based on whether hook fixation was used and whether a gap was present behind the plate. The upper surface of the host bone was fixed, and a 1,000-N load was imposed on the horizontal axis at 71°. Larger bone defects increased the stress on the KT plate and screws. This stress increased when no bone was grafted; it was lower when bulk cortical bone grafts were used for filling than when morselized cancellous bone grafts were used. For cortical bone grafts, the increased stress on the KT plate and screws was lowered with hook removal. Attaching the hook to the bone and filling the gap behind the KT plate with an adequate bone graft reduced the stress on the KT plate and screws, particularly for large bone defects filled by bulk bone grafting.


Assuntos
Acetabuloplastia/métodos , Artroplastia de Quadril/métodos , Placas Ósseas , Parafusos Ósseos , Transplante Ósseo/métodos , Análise de Elementos Finitos , Artroplastia de Quadril/instrumentação , Fenômenos Biomecânicos , Simulação por Computador , Humanos , Modelos Teóricos , Estresse Mecânico , Resultado do Tratamento
16.
J Orthop Case Rep ; 14(4): 120-124, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38681932

RESUMO

Introduction: COVID-19 may be associated with orthopedic symptoms, including myalgia and joint pain. There are reports of reactive arthritis and acute arthritis diagnosed after COVID-19; however, COVID-19-associated pyogenic arthritis has not been reported. Case Report: We treated a young woman with secondary pyogenic hip arthritis that started after COVID-19. The patient was a 23-year-old woman who developed acute pain in the right hip 9 days after being diagnosed with COVID-19. Blood cultures revealed methicillin-sensitive Staphylococcus aureus and contrast-enhanced computed tomography revealed joint effusion in the right hip. Although the joint fluid culture results were negative, we suspected pyogenic arthritis of the hip joint and performed curettage and continuous irrigation of the right hip joint. Intraoperative histopathological examination of the synovial membrane revealed numerous neutrophils with segmental nuclei, consistent with a diagnosis of pyogenic arthritis. Conclusion: To the best of our knowledge, this is the first report of probable secondary pyogenic hip arthritis in a patient with COVID-19.

17.
Cureus ; 16(6): e61546, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38962584

RESUMO

Introduction Optimal repair of the joint line (JL) in total knee arthroplasty (TKA) is critical for knee joint motion reconstruction and ligament balance. Identification of JL may be difficult, particularly in revision or primary cases of severe femoral condylar bone loss. We aimed to define the relationship between the epicondyles and the articular surface (AS) of the femur using computed tomography-based three-dimensional digital templating software. Methods The study included 127 knees with osteoarthritis of the knee below grade 2 on the Kellgren-Lawrence index. A perpendicular line was drawn from the medial and lateral femoral epicondylar processes to the most distal point of the AS, and the distance was measured in the axial and coronal planes. Femoral width was measured as the distance between the medial and lateral epicondyles. All distances described above were converted to a ratio by division with femoral width. Results On the axial plane, the distance from epicondyles to the posterior ASs was 29.4 ± 2.2 mm medially and 21.3 ± 2.1 mm laterally. The width of the distal femur was 75.2 ± 4.2 mm. On the coronal plane, the distances from epicondyles to the distal ASs were 25.2 ± 2.9 mm on the medial side and 21.3 ± 2.5 mm on the lateral side. The ratio of the distance from epicondyles to the distal and posterior ASs divided by the width of the femur was 0.39 ± 0.02, 0.28 ± 0.03, 0.34 ± 0.03, and 0.28 ± 0.03. Conclusions The distance from the epicondyles to the distal and posterior JLs correlates with the distal femur width. These findings may be useful in determining an appropriate JL.

18.
J Orthop Case Rep ; 14(2): 70-75, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420253

RESUMO

Introduction: Unilateral subchondral insufficiency fractures (SIF) of the femoral head have been reported in many cases; however, bilateral cases occurring simultaneously are very rare. Case Report: We report two cases of relatively active elderly females (aged 73 and 67 years), in which bilateral hip pain appeared simultaneously without any specific triggers. There were no notable lifestyle or medication histories. Imaging and histopathology of the bone excised surgically supported the diagnosis. In Case 1, there was a decrease in bone mineral density and poor congruency between the femoral head and acetabulum. In Case 2, the posterior tilt of the pelvis with aging decreased coverage of the femoral head, and the poor congruency between the femoral head and acetabulum was thought to have contributed to uneven distribution and increased stress in the loading zone. Conclusion: We encountered two unusual cases with contemporaneous bilateral SIF in the elderly. In recent years, the number of highly active elderly people has increased with the increase in healthy life expectancy. The combined effect of factors such as bone fragility, posterior pelvic tilt, and high activity level likely caused bilateral SIFs, and we should be careful as we expect to see an increase in such cases in the future.

19.
Cureus ; 16(3): e56862, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38659568

RESUMO

Introduction During total knee arthroplasty (TKA), also referred to as total knee replacement (TKR), patients may experience pain in the posterolateral knee. One possible cause is the impingement between the popliteus tendon and the femoral components. The purpose of this study was to analyze the posterolateral overhang of the femoral component using 3D template software. Methods Preoperative CT scan images of 50 knees (11 males and 39 females) with osteoarthritis of grade 2 or lower according to the Kellgren-Lawrence classification were analyzed. The mean age of the subjects was 73.8±7.6 years (range 52-84 years). The Athena (Soft Cube Co., Ltd., Osaka, Japan) knee 3D image-matching software was used for the analysis. The positions of the two femoral components (symmetrical and asymmetrical) were simulated. In the coronal plane, the component overhang was measured between the resected lateral part of the posterior femur and its corresponding component size, and the two designs were compared in three zones (proximal, central, and distal). Results In the simulated femoral component, the asymmetric design had a significantly lower component overhang than the symmetric design in the proximal zone of the lateral posterior condyle (0.2±1.9 mm vs. 3.5±1.6 mm, p<0.01). In the proximal zone, significant overhang (>3 mm) was observed in 30 knees (60.0%) with the symmetric design, but only three knees (6.0%) had asymmetric designs (p<0.01). Conclusions The posterolateral overhang of the lateral posterior condyle occurs when a symmetrical prosthesis is used. The use of an asymmetric implant with a small, rounded proximal portion of the lateral posterior condyle improves this overhang and is expected to decrease problems such as impingement of the popliteus tendon and improve patient satisfaction.

20.
Artigo em Inglês | MEDLINE | ID: mdl-38317625

RESUMO

Medial collateral ligament (MCL) pie-crusting can balance the soft tissue during total knee arthroplasty but requires more studies with the finite element method (FEM). We have developed three models of MCL pie-crusting utilizing FEM, treating the MCL in the following ways: (1) as a singular elastic body with both ends attached to the bone (model A), (2) as 19 bundled elastic bodies, each attached to both ends of the bone (model B), and (3) as 19 bundled elastic bodies with an adhesive component in the gap, attached to both ends of the bone (model C). The pie-crusting model was created by adding a cut around the center of each model. The left side of the model was fixed and forces of 80 and 120 N in the positive direction of the x-axis were applied. Model A was extended by 0.0068 and 0.010 mm for approximately 10 punctures. Model B-2 was extended by 1.34 and 2.01 mm, approximately twice as much as model B-1. Model C was extended by 0.34 and 0.50 mm for every 10 punctures added. These findings clarify that the model composed of aggregates of fibers with adhesive parts (model C) is suitable for MCL pie-crusting analysis.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA