Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
1.
Eur J Nucl Med Mol Imaging ; 44(2): 321-331, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27550420

RESUMO

PURPOSE: The purpose of this study was to evaluate the usefulness of L-4-borono-2-18F-fluoro-phenylalanine (18F-FBPA) as a tumor-specific probe, in comparison to 18F-FDG and 11C-methionine (Met), focusing on its transport selectivity by L-type amino acid transporter 1 (LAT1), which is highly upregulated in cancers. METHODS: Cellular analyses of FBPA were performed to evaluate the transportablity and Km value. PET studies were performed in rat xenograft models of C6 glioma (n = 12) and in rat models of turpentine oil-induced subcutaneous inflammation (n = 9). The kinetic parameters and uptake values on static PET images were compared using the one-tissue compartment model (K1, k2) and maximum standardized uptake value (SUVmax). RESULTS: The cellular analyses showed that FBPA had a lower affinity to a normal cell-type transporter LAT2 and induced less efflux through LAT2 among FBPA, Met, and BPA, while the efflux through LAT1 induced by FBPA was similar among the three compounds. The Km value of 18F-FBPA for LAT1 (196.8 ± 11.4 µM) was dramatically lower than that for LAT2 (2813.8 ± 574.5 µM), suggesting the higher selectivity of 18F-FBPA for LAT1. K1 and k2 values were significantly smaller in 18F-FBPA PET (K1 = 0.04 ± 0.01 ml/ccm/min and k2 = 0.07 ± 0.01 /min) as compared to 11C-Met PET (0.22 ± 0.09 and 0.52 ± 0.10, respectively) in inflammatory lesions. Static PET analysis based on the SUVmax showed significantly higher accumulation of 18F-FDG in the tumor and inflammatory lesions (7.2 ± 2.1 and 4.6 ± 0.63, respectively) as compared to both 18F-FBPA (3.2 ± 0.40 and 1.9 ± 0.19) and 11C-Met (3.4 ± 0.43 and 1.6 ± 0.11). No significant difference was observed between 18F-FBPA and 11C-Met in the static PET images. CONCLUSION: This study shows the utility of 18F-FBPA as a tumor-specific probe of LAT1 with low accumulation in the inflammatory lesions.


Assuntos
Compostos de Boro/farmacocinética , Fluordesoxiglucose F18/farmacocinética , Glioma/metabolismo , Transportador 1 de Aminoácidos Neutros Grandes/metabolismo , Metionina/farmacocinética , Fenilalanina/análogos & derivados , Tomografia por Emissão de Pósitrons/métodos , Animais , Linhagem Celular Tumoral , Glioma/diagnóstico por imagem , Masculino , Taxa de Depuração Metabólica , Imagem Molecular/métodos , Técnicas de Sonda Molecular , Sondas Moleculares , Fenilalanina/farmacocinética , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Ratos Endogâmicos F344 , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Bioorg Med Chem ; 22(8): 2563-70, 2014 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-24656799

RESUMO

Positron-emission tomography (PET) can be used to visualize active stage cancer. Fluorine-18 ([(18)F])-labeled 2-([(18)F])2-deoxy-2-fluoroglucose (([(18)F])-FDG), which accumulates in glucose-dependent tissues, is a good cancer-targeting tracer. However, ([(18)F])-FDG is obscured in glucose-dependent normal tissues. In this study, we assessed the cancer-selective accumulation of zinc-labeled glycoconjugated 5,10,15,20-tetrakis(pentafluorophenyl)porphyrin (ZnGlc1-4), both in vitro and in vivo. Experiments using both normal and cancer cells confirmed the relationship between cancer cell-selective accumulation and the substitution numbers and orientations of glycoconjugated porphyrins. ZnGlctrans-2 accumulated at greater levels in cancer cells compared with other glycoconjugated porphyrins. PET imaging showed that ZnGlctrans-2 accumulated in tumor.


Assuntos
Porfirinas/química , Compostos Radiofarmacêuticos/química , Animais , Linhagem Celular Tumoral , Imageamento por Ressonância Magnética , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Neoplasias/diagnóstico por imagem , Porfirinas/metabolismo , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/metabolismo , Ratos , Distribuição Tecidual , Transplante Heterólogo , Radioisótopos de Zinco/química
3.
Biol Pharm Bull ; 37(3): 355-60, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24583857

RESUMO

Epidermal growth factor receptor (EGFR) is attractive target for tumor diagnosis and therapy, as it is specifically and abundantly expressed in tumor cells. EGFR-tyrosine kinase (TK) inhibitors such as gefitinib and erlotinib are widely used in the treatment of non-small cell lung cancer (NSCLC). In this study, we investigated whether radioiodinated 4-(3-iodo-phenoxy)-6,7-diethoxy-quinazoline (PHY), which is a candidate EGFR-TK imaging agent for single photon emission computed tomography (SPECT) is able to predict gefitinib sensitivity. We used four NSCLC cell lines-A549 (wild-type EGFR), H1650 (mutant EGFR; del E746_A750), H1975 (mutant EGFR; L858R, T790M) and H3255 (mutant EGFR; L858R)-and one epidermoid carcinoma cell line, A431 (wild-type EGFR). Cell proliferation assay and Western blotting revealed that A431 and H3255 with high EGFR expression showed high sensitivity to gefitinib. On the other hand, A549, H1650 and H1975 showed much lower sensitivity to gefitinib. The blocking study revealed that gefitinib decreased tumor uptake in (125)I-PHY in A431-bearing mice. Moreover, in vivo tumor uptake of (125)I-PHY was correlated with the IC50 of gefitinib for cell proliferation. In the present study, tumor uptake of (125)I-PHY was correlated with the gefitinib sensitivity and this uptake was based on expression levels of EGFR, but not on mutation status. Although the mutation status is the most important factor for predicting gefitinib sensitivity, the abundant expression of EGFR is essential for therapy with EGFR-TK inhibitors. Therefore, radioiodinated PHY is a potential imaging agent to predict gefitinib sensitivity based on EGFR expression levels though further modifications of the imaging agent is needed to accurately estimate the mutation status.


Assuntos
Antineoplásicos/farmacologia , Carcinoma Pulmonar de Células não Pequenas , Carcinoma de Células Escamosas , Receptores ErbB , Neoplasias Pulmonares , Mutação , Quinazolinas/farmacologia , Animais , Antineoplásicos/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma de Células Escamosas/tratamento farmacológico , Carcinoma de Células Escamosas/genética , Carcinoma de Células Escamosas/metabolismo , Linhagem Celular Tumoral , Proliferação de Células , Receptores ErbB/genética , Receptores ErbB/metabolismo , Feminino , Gefitinibe , Humanos , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/metabolismo , Camundongos , Camundongos Endogâmicos BALB C , Camundongos Nus , Inibidores de Proteínas Quinases/farmacologia , Inibidores de Proteínas Quinases/uso terapêutico , Quinazolinas/uso terapêutico , Tomografia Computadorizada de Emissão de Fóton Único/métodos
4.
Proc Jpn Acad Ser B Phys Biol Sci ; 90(10): 413-21, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25504230

RESUMO

In order to establish a self-sufficient supply of (99m)Tc, we studied feasibilities to produce its parent nucleus, (99)Mo, using Japanese accelerators. The daughter nucleus, (99m)Tc, is indispensable for medical diagnosis. (99)Mo has so far been imported from abroad, which is separated from fission products generated in nuclear reactors using enriched (235)U fuel. We investigated (99m)Tc production possibilities based on the following three scenarios: (1) (99)Mo production by the (n, 2n) reaction by spallation neutrons at the J-PARC injector, LINAC; (2) (99)Mo production by the (p, pn) reaction at Ep = 50-80 MeV proton at the RCNP cyclotron; (3) (99m)Tc direct production with a 20 MeV proton beam from the PET cyclotron. Among these three scenarios, scenario (1) is for a scheme on a global scale, scenario (2) works in a local area, and both cases take a long time for negotiations. Scenario (3) is attractive because we can use nearly 50 PET cyclotrons in Japan for (99m)Tc production. We here consider both the advantages and disadvantages among the three scenarios by taking account of the Japanese accelerator situation.


Assuntos
Ciclotrons , Molibdênio/química , Reatores Nucleares , Radioisótopos/provisão & distribuição , Tecnécio/química , Técnicas de Diagnóstico por Radioisótopos , Humanos , Japão , Radioisótopos/química , Urânio/química
5.
EJNMMI Radiopharm Chem ; 9(1): 46, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38834900

RESUMO

BACKGROUND: Signal transducer and activator of transcription 3 (STAT3) is a protein that regulates cell proliferation and differentiation, and it is attracting attention as a new index for evaluating cancer pathophysiology, as its activation has been highly correlated with the development and growth of tumors. With the development of STAT3 inhibitors, the demand for imaging probes will intensify. Noninvasive STAT3 imaging can help determine the cancer status and predict the efficacy of STAT3 inhibitors. In this study, we aimed to develop an imaging probe targeting STAT3 and synthesized [18F]FBNAF, which was derived from a STAT3-selective inhibitor as the lead compound, followed by in vitro and in vivo evaluations of [18F]FBNAF in positron emission tomography for STAT3. RESULTS: The results revealed that FBNAF concentration-dependently inhibited STAT3 phosphorylation, similar to the lead compound, thereby supporting radiosynthesis. [18F]FBNAF was easily synthesized from the pinacol boronate ester precursor with suitable radiochemical conversion (46%), radiochemical yield (6.0%), and radiochemical purity (> 97%). [18F]FBNAF exhibited high stability in vitro and in vivo, and radioactivity accumulated in tumor tissues expressing STAT3 with an increasing tumor/blood ratio over time, peaking at 2.6 ± 0.8 at 120 min after injection in tumor-bearing mice. Tumor radioactivity was significantly reduced by the coinjection of a STAT3-selective inhibitor. Furthermore, the localization of radioactivity was almost consistent with STAT3 expression based on ex vivo autoradiography and immunohistochemistry using adjacent tumor sections. CONCLUSIONS: Thus, [18F]FBNAF could be the first promising STAT3-targeting probe for PET imaging. A STAT3 imaging probe provides meaningful information on STAT3-associated cancer conditions and in tumor microenvironment.

6.
Cancer Med ; 13(11): e7250, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38826090

RESUMO

PURPOSE: Since June 2020, boron neutron capture therapy (BNCT) has been a health care service covered by health insurance in Japan to treat locally advanced or recurrent unresectable head and neck cancers. Therefore, we aimed to assess the clinical outcomes of BNCT as a health insurance treatment and explore its role among the standard treatment modalities for head and neck cancers. MATERIALS AND METHODS: We retrospectively analyzed data from patients who were treated using BNCT at Kansai BNCT Medical Center, Osaka Medical and Pharmaceutical University, between June 2020 and May 2022. We assessed objective response rates based on the Response Evaluation Criteria in Solid Tumors version 1.1, and adverse events based on the Common Terminology Criteria for Adverse Events, version 5.0. Additionally, we conducted a survival analysis and explored the factors that contributed to the treatment results. RESULTS: Sixty-nine patients (72 treatments) were included in the study, with a median observation period of 15 months. The objective response rate was 80.5%, and the 1-year locoregional control, progression-free survival, and overall survival rates were 57.1% (95% confidence interval [CI]: 43.9%-68.3%), 42.2% (95% CI: 30.1%-53.8%), and 75.4% (95% CI: 62.5%-84.5%), respectively. Locoregional control was significantly longer in patients with earlier TNM staging and no history of chemotherapy. CONCLUSIONS: BNCT may be an effective treatment option for locally advanced or recurrent unresectable head and neck cancers with no other definitive therapies. If definitive surgery or radiation therapy are not feasible, BNCT should be considered at early disease stages.


Assuntos
Terapia por Captura de Nêutron de Boro , Neoplasias de Cabeça e Pescoço , Humanos , Terapia por Captura de Nêutron de Boro/métodos , Masculino , Feminino , Neoplasias de Cabeça e Pescoço/radioterapia , Neoplasias de Cabeça e Pescoço/terapia , Neoplasias de Cabeça e Pescoço/mortalidade , Japão , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Adulto , Idoso de 80 Anos ou mais , Resultado do Tratamento , Seguro Saúde , Taxa de Sobrevida
7.
Bioorg Med Chem ; 21(17): 5310-5, 2013 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-23830700

RESUMO

Polymeric nanoparticles (NPs) comprised of hydrophilic poly(γ-glutamic acid) in the main chain and hydrophobic phenylalanine in the side chain (γ-PGA-Phe) are a promising vaccine carrier for various kinds of diseases. However, little is known about the fate of subcutaneously administered γ-PGA-Phe NPs. Therefore, we newly synthesized γ-PGA graft phenylalanine and tyrosine conjugates (γ-PGA-Phe-Tyr), and then γ-PGA-Phe-Tyr NPs were labeled with (125)I for monitoring their biodistribution (γ-PGA-Phe-Tyr((125)I) NPs). Dynamic light scattering (DLS) measurements showed that γ-PGA-Phe-Tyr((125)I) NPs showed 200nm in diameter and a negative ζ-potential, which was comparable to those of their precursors. γ-scintigraphic images showed that in mice, subcutaneously injected γ-PGA-Phe-Tyr((125)I) NPs were mainly observed at the site of injection (SOI), but not other organs 1h after administration. However, γ-PGA-PheTyr((125)I) NPs were almost undetectable at the SOI and other organs at 11days postinjection. Similar results were observed when γ-PGA-Phe-Tyr((125)I) NPs were subcutaneously injected into rats. Furthermore, at 11days postinjection, 73±3% of the injected dose of γ-PGA-Phe-Tyr((125)I) NPs was detected in the feces (14±1%) and urine (59±1%). These results clearly showed that subcutaneously injected γ-PGA-Phe-Tyr((125)I) NPs were cleared from the body, and γ-PGA-Phe NPs were safe and effective vaccine carriers.


Assuntos
Nanopartículas/metabolismo , Ácido Poliglutâmico/análogos & derivados , Vacinas/metabolismo , Animais , Injeções Subcutâneas , Radioisótopos do Iodo/química , Luz , Camundongos , Nanopartículas/química , Ácido Poliglutâmico/síntese química , Ácido Poliglutâmico/química , Ácido Poliglutâmico/metabolismo , Ratos , Espalhamento de Radiação , Distribuição Tecidual , Vacinas/química
8.
Med Phys ; 39(11): 6660-71, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23127060

RESUMO

PURPOSE: The simultaneous measurement of PET and magnetic resonance imaging (MRI) is an emerging field for molecular imaging research. Although optical fiber based PET∕MRI systems have advantages on less interference between PET and MRI, there is a drawback in reducing the scintillation light due to the fiber. To reduce the problem, the authors newly developed flexible optical fiber bundle based block detectors and employed them for a high resolution integrated PET∕MRI system. METHODS: The flexible optical fiber bundle used 0.5 mm diameter, 80 cm long double clad fibers which have dual 12 mm × 24 mm rectangular inputs and a single 24 mm × 24 mm rectangular output. In the input surface, LGSO scintillators of 0.025 mol.% (decay time: ∼31 ns: 0.9 mm × 1.3 mm × 5 mm) and 0.75 mol.% (decay time: ∼46 ns: 0.9 mm × 1.3 mm × 6 mm) were optically coupled in depth direction to form depth-of-interaction detector, arranged in 11 × 13 matrix and optically coupled to the fiber bundle. The two inputs of the bundle are bent for 90°, bound to one, and are optically coupled to a Hamamatsu 1-in. square position sensitive photomultiplier tube. RESULTS: Light loss due to the fiber bundle could be reduced and the performance of the block detectors was improved. Eight optical fiber based block detectors (16 LGSO blocks) were arranged in a 56 mm diameter ring to form a PET system. Spatial resolution and sensitivity were 1.2 mm full-width at half-maximum and 1.2% at the central field-of-view, respectively. Sensitivity change was less than 1% for 2 °C temperature changes. This PET system was integrated with a 0.3 T permanent magnet MRI system which has 17 cm diameter hole at the yoke area for insertion of the PET detector ring. There was no observable interference between PET and MRI. Simultaneous imaging of PET and MRI was successfully performed for small animal studies. CONCLUSIONS: The authors confirmed that the developed high resolution PET∕MRI system is promising for molecular imaging research.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Fibras Ópticas , Tomografia por Emissão de Pósitrons/instrumentação , Animais , Encéfalo/diagnóstico por imagem , Equipamentos e Provisões Elétricas , Coração/diagnóstico por imagem , Camundongos , Ratos , Fatores de Tempo
9.
Nucl Med Mol Imaging ; 56(2): 86-95, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35449598

RESUMO

Purpose: 4-Borono-2-[18F]fluoro-l-phenylalanine ([18F]FBPA) synthesized with [18F]F2, produced using the 18O(p, n)18F reaction, has been reported for increasing radioactivity. However, a dedicated system and complex procedure is required to reuse the costly [18O]O2 gas; also, the use of [18F]F2 as a labeling agent reduces the labeling rate and radiochemical purity. We developed a stable and practical method for [18F]FBPA synthesis by combining [18F]F2, produced using a [18O]O2 single-use system, and a [18F]CH3COOF labeling agent. Methods: The produced [18F]F2 was optimized, and then [18F]FBPA was synthesized. For passivation of the target box, 0.5% F2 was pre-irradiated in argon. Gaseous products were discarded; the target box was filled with [18O]O2 gas, and then irradiated (first irradiation). Then, the [18O]O2 gas was discarded, 0.05-0.08% F2 in argon was fed into the target box, and it was again irradiated (second irradiation). The [18F]F2 obtained after this was passed through a CH3COONa column, converting it into the [18F]CH3COOF labeling agent, which was then used for [18F]FBPA synthesis. Results: The mean amount of as-obtained [18F]F2 was 55.0 ± 3.3 GBq and that of as-obtained [18F]CH3COOF was 21.6 ± 1.4 GBq after the bombardment. The radioactivity and the radiochemical yield based on [18F]F2 of [18F]FBPA were 4.72 ± 0.34 GBq and 12.2 ± 0.1%, respectively. The radiochemical purity and molar activity were 99.3 ± 0.1% and 231 ± 22 GBq/mmol, respectively. Conclusion: We developed a method for [18F]FBPA production, which is more stable and practical compared with the method using [18O]O2 gas-recycling and [18F]F2 labeling agent.

10.
Med Phys ; 49(3): 1822-1830, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34958515

RESUMO

PURPOSE: Optical imaging of ionizing radiation is a possible method for dose distribution measurements. However, it is not clear whether the imaging method is also applicable to neutrons. To clarify this, we performed the imaging of neutrons in water from boron neutron capture therapy (BNCT) systems. Such systems require efficient distribution measurements of neutrons for quality assessment (QA) of the beams. METHOD: A water-filled phantom was irradiated from the side with an epithermal neutron beam, in which a lithium-containing zinc sulfate (Li-ZnS(Ag)) plate was set in the beam direction, and during this irradiation the scintillation of the plate was imaged using a cooled charge-coupled device (CCD) camera. In the imaging, Li-6 in the Li-ZnS(Ag) plate captures neutrons and converts them to alpha particles (He-4) and tritium (H-3), while ZnS(Ag) in the Li-ZnS(Ag) plate produces scintillation light in the plate. We also conducted Monte Carlo simulation and compared its results with the experimental results. RESULTS: The image of the emitted light from the Li-ZnS(Ag) plate was clearly obtained with an imaging time of 0.5 s. The depth and lateral profiles of the measured image using the Li-ZnS(Ag) plate showed the same shapes as the neutron distributions measured with gold foil, within a difference of 8%. The destructive effect of neutrons on the CCD camera increased approximately three times, but the unit was still working after the measurement. CONCLUSION: The optical imaging of neutrons in water is possible, and it has the potential to be a new method for efficient QA as well as for research on neutrons.


Assuntos
Terapia por Captura de Nêutron de Boro , Terapia por Captura de Nêutron de Boro/métodos , Lítio , Método de Monte Carlo , Nêutrons , Imagem Óptica , Água , Zinco , Sulfato de Zinco
11.
Eur J Hybrid Imaging ; 6(1): 35, 2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36464732

RESUMO

BACKGROUND: The goal of the study was to evaluate the diagnostic ability of 18F-FBPA PET/CT for malignant tumors. Findings from 18F-FBPA and 18F-FDG PET/CT were compared with pathological diagnoses in patients with malignant tumors or benign lesions. METHODS: A total of 82 patients (45 males, 37 females; median age, 63 years; age range, 20-89 years) with various types of malignant tumors or benign lesions, such as inflammation and granulomas, were examined by 18F-FDG and 18F-FBPA PET/CT. Tumor uptake of FDG or FBPA was quantified using the maximum standardized uptake value (SUVmax). The final diagnosis was confirmed by cytopathology or histopathological findings of the specimen after biopsy or surgery. A ROC curve was constructed from the SUVmax values of each PET image, and the area under the curve (AUC) and cutoff values were calculated. RESULTS: The SUVmax for 18F-FDG PET/CT did not differ significantly for malignant tumors and benign lesions (10.9 ± 6.3 vs. 9.1 ± 2.7 P = 0.62), whereas SUVmax for 18F-FBPA PET/CT was significantly higher for malignant tumors (5.1 ± 3.0 vs. 2.9 ± 0.6, P < 0.001). The best SUVmax cutoffs for distinguishing malignant tumors from benign lesions were 11.16 for 18F-FDG PET/CT (sensitivity 0.909, specificity 0.390) and 3.24 for 18F-FBPA PET/CT (sensitivity 0.818, specificity 0.753). ROC analysis showed significantly different AUC values for 18F-FDG and 18F-FBPA PET/CT (0.547 vs. 0.834, p < 0.001). CONCLUSION: 18F-FBPA PET/CT showed superior diagnostic ability over 18F-FDG PET/CT in differential diagnosis of malignant tumors and benign lesions. The results of this study suggest that 18F-FBPA PET/CT diagnosis may reduce false-positive 18F-FDG PET/CT diagnoses.

12.
Oncol Lett ; 21(3): 207, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33574946

RESUMO

Carbon dioxide (CO2) treatment is reported to have an antitumor effect owing to the improvement in intratumoral hypoxia. Previous studies were based on histological analysis alone. In the present study, the improvement in intratumoral hypoxia by percutaneous CO2 treatment in vivo was determined using 18F-fluoromisonidazole positron emission tomography-computed tomography (18F-FMISO PET-CT) images. Twelve Japanese nude mice underwent implantation of LM8 tumor cells in the dorsal subcutaneous area 2 weeks before percutaneous CO2 treatment and 18F-FMISO PET-CT scans. Immediately after intravenous injection of 18F-FMISO, CO2 and room air were administered transcutaneously in the CO2-treated group (n=6) and a control group (n=6), respectively; each treatment was performed for 10 minutes. PET-CT was performed 2 h after administration of 18F-FMISO. 18F-FMISO tumor uptake was quantitatively evaluated using the maximum standardized uptake value (SUVmax), tumor-to-liver ratio (TLR), tumor-to-muscle ratio (TMR), metabolic tumor volume (MTV) and total lesion glycolysis (TLG). Mean ± standard error of the mean (SEM) of the tumor volume was not significantly different between the two groups (CO2-treated group, 1.178±0.450 cm3; control group, 1.368±0.295 cm3; P=0.485). Mean ± SEM of SUVmax, TLR, MTV (cm3) and TLG were significantly lower in the CO2-treated group compared with the control group (0.880±0.095 vs. 1.253±0.071, P=0.015; 1.063±0.147361 vs. 1.455±0.078, P=0.041; 0.353±0.139 vs. 1.569±0.438, P=0.015; 0.182±0.070 vs. 1.028±0.338, P=0.015), respectively. TMR was not significantly different between the two groups (4.520±0.503 vs. 5.504±0.310; P=0.240). In conclusion, 18F-FMISO PET revealed that percutaneous CO2 treatment improved intratumoral hypoxia in vivo. This technique enables assessment of the therapeutic effect in CO2 treatment by imaging, and may contribute to its clinical application.

13.
Ann Nucl Med ; 34(3): 155-162, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31808134

RESUMO

OBJECTIVE: Boron neutron capture therapy (BNCT) is a noninvasive radiation therapy method for cancer treatment. In BNCT, 4-borono-2-[18F]-fluoro-L-phenylalanine (18F-FBPA) PET has been employed to estimate 10B accumulation in target tumors and normal tissues if 10B borono-L-phenylalanine (10B-BPA) is used as a boron carrier. The purpose of the current study was to evaluate the total distribution volume (Vt) of 18F-FBPA in normal organs of healthy volunteers by kinetic analysis and to estimate boron concentration in normal organs for the therapeutic dose of 10B-BPA using obtained Vt values. METHODS: Six healthy volunteers were injected with 18F-FBPA (3-5 MBq/kg), and 7 PET-CT scans were performed subsequently. 18F-FBPA radioactivity in whole blood and plasma was measured before, and eight times after the injection. PET images were analyzed by PMOD software. Twelve volumetric regions of interest including the brain, heart, right lung, spleen, liver, parotid salivary glands, esophagus, stomach, pancreas, intestines, and bone marrow were drawn manually for each subject and analyzed with the Logan plot and two Ichise multilinear analyses (MA1 and MA2). The better model was defined by several goodness-of-fit parameters and residual distribution. After Vt values had been derived, boron concentration was estimated in ppm for the 10B-BPA-fructose (10B-BPA-fr) dose 30 g 1 and 2 h post-injection using Vt and interpolated plasma activity data. RESULTS: The Ichise MA2 model showed the best fit among all models. Akaike Information Criterion (AIC) was the lowest for the Ichise's MA2 in all regions (mean AIC value - 14.0) comparing to the other models (Logan plot mean AIC 31.4; Ichise MA1 model mean AIC - 4.2). Mean Vt values of the Ichise MA2 model ranged from 0.94 ± 0.14 ml/ml in the pancreas to 0.16 ± 0.02 ml/ml in the right lung. Estimated boron concentration for 10B-BPA-fr had the highest value in the pancreas (14.0 ± 1.9 ppm 1 h after, and 5.7 ± 1.7 ppm 2 h after the 18F-FBPA administration) and the lowest value in the right lung (2.4 ± 0.3 ppm 1 h, and 1.0 ± 0.3 ppm 2 h post-injection). CONCLUSION: The 10B concentration in normal tissues was best estimated using Vt values of 18F-FBPA with the Ichise multilinear analysis 2 (MA2). TRAIL REGISTRY: The UMIN clinical trial number: UMIN000022850.


Assuntos
Compostos de Boro/farmacocinética , Terapia por Captura de Nêutron de Boro/métodos , Neoplasias/radioterapia , Fenilalanina/análogos & derivados , Adulto , Compostos de Boro/administração & dosagem , Compostos de Boro/síntese química , Relação Dose-Resposta à Radiação , Feminino , Radioisótopos de Flúor/química , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Fenilalanina/administração & dosagem , Fenilalanina/síntese química , Fenilalanina/farmacocinética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
14.
Asia Ocean J Nucl Med Biol ; 8(2): 102-108, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32714997

RESUMO

OBJECTIVES: L-4-borono-2-18F-fluoro-phenylalanine (L-[18F]FBPA), a substrate of L-type amino acid transporter 1 (LAT1), is a tumor-specific probe used in positron emission tomography (PET). On the other hand, it has not been examined whether another isomer D-[18F]FBPA accumulates specifically in the tumor. Here, we compared the accumulation of D-[18F]FBPA in C6 glioma and inflammation to evaluate the performance of D-[18F]FBPA as a tumor-specific probe. METHODS: HEK293-LAT1 and HEK293-LAT2 cells were tested for [14C]-leucine or [14C]-alanine transport, and IC50 values of L- and D-FBPA were evaluated in both cell types. PET was conducted in rat xenograft model of C6 glioma with LAT1 expression and model of turpentine oil-induced subcutaneous inflammation (n=10 for both models). The concentrations of D-[18F]FBPA were compared between glioma and inflammatory lesion using standardized uptake value (SUV). RESULTS: In contrast to L-FBPA, which inhibited substrate uptake in both HEK293-LAT1 and -LAT2 cells, D-FBPA showed no inhibitory effect on both cells, suggesting low transporter selectivity of D-[18F]FBPA against LAT1 and LAT2. Static PET analysis showed low accumulation of D-[18F]FBPA in C6 glioma and inflammatory lesion (SUVmax=0.80±0.16, 0.56±0.09, respectively). Although there was a statistical difference in SUVmax between these tissues, it was difficult to distinguish glioma from inflammation on the PET image due to its low uptake level. Therefore, it was suggested that D-[18F]FBPA is not a suitable tumor-specific probe for oncology PET in contrast to L-[18F]FBPA. CONCLUSION: This study demonstrated that D-[18F]FBPA is not a LAT1-specific PET probe and shows low uptake in C6 glioma, indicating its unsuitability as a tumor diagnosis PET probe.

15.
Brain Res ; 1719: 208-216, 2019 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-31132338

RESUMO

This study was aimed at evaluating the regional changes in the cerebral metabolic rate of oxygen (CMRO2) in relation to the cerebral blood flow (CBF) in the bilateral common carotid artery occlusion (BCAO) rat model. Ligation of the bilateral common carotid arteries (or a sham operation in control animals) was performed in 10-week-old male Wistar rats. O-15 PET images were acquired in the subacute phase (1 week after the surgery) and chronic phase (6 weeks after the surgery) with the animals under anesthesia, using a small-animal PET system and the O-15 gas steady-state inhalation method with arterial blood sampling developed in our previous study. Histopathological staining by Klüver-Barrera method and immunocytochemistry staining by glial fibrillary acidic protein were performed. Cognitive function was tested by using the apparatus of Y-maze. Significantly lower CBF and higher oxygen extraction fraction were observed in broad areas of the cerebrum in the subacute phase in the BCAO rats, with recovery in the chronic phase. A stable decrease of the CMRO2 in the subacute phase of arterial occlusion and later was observed in the BCAO rat model, mainly in the anterior cerebral artery territory. Atrophy and rarefaction of corpus callosum were found in the BCAO in the chronic phase. Activity of astrocytes in the BCAO was prominent in the both phases. Working memory was impaired in the BCAO in the chronic phase. Regional changes in cerebral perfusion and oxygen metabolism in the subacute and chronic phases of arterial occlusion were clarified in a rat model of BCAO by quantitative O-15 PET based on the steady-state method.


Assuntos
Circulação Cerebrovascular/fisiologia , Oxigênio/metabolismo , Animais , Encéfalo/metabolismo , Isquemia Encefálica/patologia , Doenças das Artérias Carótidas/patologia , Artéria Carótida Primitiva/fisiologia , Estenose das Carótidas/metabolismo , Cognição , Modelos Animais de Doenças , Masculino , Ratos , Ratos Wistar
16.
Ann Nucl Med ; 33(5): 333-343, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30953245

RESUMO

OBJECTIVE: p38 mitogen-activated protein (MAP) kinase (p38α) has drawn attention as a new target molecule for the treatment and diagnosis of cancer, and its overexpression and activation have been reported in various types of cancer. In this study, a single photon emission computed tomography (SPECT) imaging probe of p38α was developed to noninvasively image p38α activity for effective qualitative diagnosis of cancer. METHODS: Pyrrolepyridine derivatives, m-YTM and p-YTM, were designed and synthesized based on the structure of the p38α-selective inhibitor. Radioactive iodine-labeled m-YTM, [125I]m-YTM, was synthesized because m-YTM greatly inhibited the phosphorylation of p38α upon examining the inhibitory effects of the compounds. After investigating the binding affinity of [125I]m-YTM to the recombinant p38α, a saturation binding experiment using activated p38α and inactive p38α was performed to determine the binding site. Uptake of [125I]m-YTM into various cancer cell lines was investigated, and the pharmacokinetics was evaluated using tumor-bearing mice. RESULTS: The inhibitory activity of m-YTM was approximately 13 times higher than that of SB203580, a p38α-selective inhibitor. The binding site of [125I]m-YTM was estimated to be the p38α activating site, similar to that of SB203580, because the [125I]m-YTM bound strongly to both activated p38α and inactive p38α. Various different cancer cells incorporated [125I]m-YTM; however, its accumulation was significantly reduced by treatment with SB203580. Pharmacokinetics study of [125I]m-YTM in B-16 tumor-bearing mice was examined which revealed high accumulation of radioactivity in tumor tissues. The ratios of radioactivity in the B-16 tumor to that in blood were 3.1 and 50 after 1 and 24 h, respectively. The ratio of radioactivity in the tumor to that in blood in the tumor-bearing mice generated using other cancer cell lines was also ≥ 1 at 1 h after the administration of the probe. CONCLUSIONS: This study suggests that [123I]m-YTM has potential as a p38α imaging probe effective for various cancer types.


Assuntos
Proteína Quinase 14 Ativada por Mitógeno/metabolismo , Neoplasias/diagnóstico por imagem , Neoplasias/metabolismo , Pirróis/química , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Animais , Transporte Biológico , Linhagem Celular Tumoral , Humanos , Masculino , Camundongos , Fosforilação/efeitos dos fármacos , Pirróis/metabolismo , Pirróis/farmacocinética , Pirróis/farmacologia , Distribuição Tecidual
17.
Brain Sci ; 9(5)2019 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-31058865

RESUMO

Fluorocitrate (FC) is a specific metabolic inhibitor of the tricarboxylic acid (TCA) cycle in astrocytes. The purpose of this study was to evaluate whether inhibition of the astrocyte TCA cycle by FC would affect the oxygen metabolism in the rat brain. At 4 h after the intracranial FC injection, the rats (n = 9) were investigated by 15O-labeled gas PET to measure the cerebral blood flow (CBF), the cerebral metabolic rate of oxygen (CMRO2), oxygen extraction fraction (OEF), and cerebral blood volume (CBV). After the 15O-gas PET, the rats were given an intravenous injection of 14C-acetate for autoradiography. 15O-gas PET showed no significant differences in any of the measured parameters between the ipsilateral and contralateral striatum (high dose group: CBF (54.4 ± 8.8 and 55.3 ± 11.6 mL/100mL/min), CMRO2 (7.0 ± 0.9 and 7.1 ± 1.2 mL/100mL/min), OEF (72.0 ± 8.9 and 70.8 ± 8.2%), and CBV (4.1 ± 0.8 and 4.2 ± 0.9 mL/100mL), respectively). In contrast, the 14C-acetate autoradiography revealed a significant inhibition of the astrocyte metabolism in the ipsilateral striatum. The regional cerebral oxygen consumption as well as the hemodynamic parameters were maintained even in the face of inhibition of the astrocyte TCA cycle metabolism in the rat brain.

18.
Ann Nucl Med ; 33(6): 394-403, 2019 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30820863

RESUMO

OBJECTIVE: L-type amino acid transporter 1 (LAT1) is strongly expressed on the cell membrane in various types of human cancer cells, while being minimally expressed in normal or inflammatory tissues. Therefore, LAT1-targeting PET tracers have been developed for cancer-specific imaging. The purpose of this study was to study the distribution of two LAT1-targeting PET tracers, L-4-borono-2-18F-fluoro-phenylalanine (18F-FBPA) and L-3-18F-alpha-methyl tyrosine (18F-FAMT), in relation to the tumor blood flow, using rat xenograft models. METHODS: Rat tumor xenograft models of C6 glioma (n = 4; tumors = 8) and MIA PaCa-2 (pancreatic cancer) (n = 4; tumors = 6) were used. The expressions of LAT1 and CD98hc were evaluated by both immunofluorescence staining and western blot analysis. Dynamic PET was performed after injection of 18F-FAMT or 18F-FBPA (scan duration = 70 min) following 15O-water PET (scan duration = 10 min). The PET data were subjected to kinetic analyses, and the K1, k2, and total distribution volume (Vt) were calculated using the one-tissue compartment model. The accumulation of the LAT1 tracers was expressed in terms of their Vt. Tumor blood flow (TBF) was represented by the K1 value in 15O-water PET. RESULTS: LAT1/CD98hc expression was confirmed in both xenografts by immunofluorescence staining. Western blot analysis showed higher functional expression of LAT1 in the C6 glioma cells as compared to the MIA PaCa-2 cells (C6 glioma/MIA PaCa-2 relative expression ratio = 1.70). The Vt values of both 18F-FBPA and 18F-FAMT were significantly higher in the C6 glioma xenografts than in the MIA PaCa-2 xenografts (C6 glioma: 2.27 ± 0.35 and 2.03 ± 0.23, respectively; MIA PaCa-2: 1.28 ± 0.26 and 1.35 ± 0.15, respectively). Meanwhile, there was no significant correlation of the Vt value of either 18F-FBPA or 18F-FAMT with the TBF, in either the C6 glioma or the MIA PaCa-2 xenografts. CONCLUSIONS: This study revealed that total distribution volumes of the LAT1-targeting PET tracers 18F-FBPA and 18F-FAMT were independent of the tumor blood flow and might reflect the functional expression levels of LAT1 in the C6 glioma and MIA PaCa-2 xenograft models.


Assuntos
Circulação Sanguínea , Transformação Celular Neoplásica , Glioma/patologia , Transportador 1 de Aminoácidos Neutros Grandes/metabolismo , Neoplasias Pancreáticas/patologia , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/farmacocinética , Animais , Compostos de Boro/metabolismo , Compostos de Boro/farmacocinética , Linhagem Celular Tumoral , Glioma/irrigação sanguínea , Glioma/diagnóstico por imagem , Glioma/metabolismo , Humanos , Masculino , Neoplasias Pancreáticas/irrigação sanguínea , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/metabolismo , Fenilalanina/análogos & derivados , Fenilalanina/metabolismo , Fenilalanina/farmacocinética , Traçadores Radioativos , Compostos Radiofarmacêuticos/metabolismo , Ratos , Distribuição Tecidual , Tirosina/análogos & derivados , Tirosina/metabolismo , Tirosina/farmacocinética
19.
Hypertens Res ; 31(6): 1157-62, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18716363

RESUMO

Diastolic heart failure (DHF) has become a high social burden, and its major underlying cardiovascular disease is hypertensive heart disease. However, the pathogenesis of DHF remains to be clarified. This study aimed to assess the effects of cardiac energy efficiency in DHF patients. (11)C-Acetate positron emission tomography and echocardiography were conducted in 11 DHF Japanese patients and 10 normal volunteers. The myocardial clearance rate of radiolabeled (11)C-acetate was measured to calculate the work metabolic index (WMI), an index of cardiac efficiency. The ratio of peak mitral E wave velocity to peak early diastolic septal myocardial velocity (E/e') was calculated to assess left ventricular (LV) filling pressure. The LV mass index was greater and the mean age was higher in the DHF patients than in the normal volunteers. There was no difference in WMI between the two groups. However, WMI varied widely among the DHF patients and was inversely correlated with E/e' (r=-0.699, p=0.017). In contrast, there was no correlation in the normal volunteers. In conclusion, the inefficiency of energy utilization is not a primary cause of diastolic dysfunction or DHF, and cardiac efficiency may not affect diastolic function in normal hearts. However, the energy-wasting state may induce the elevation of LV filling pressure in DHF patients, which was considered to principally result from the progressive diastolic dysfunction.


Assuntos
Radioisótopos de Carbono , Diástole , Insuficiência Cardíaca/metabolismo , Miocárdio/metabolismo , Tomografia por Emissão de Pósitrons/métodos , Acetatos/metabolismo , Adulto , Idoso , Ecocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Função Ventricular Esquerda
20.
Ann Nucl Med ; 22(4): 301-7, 2008 May.
Artigo em Inglês | MEDLINE | ID: mdl-18535881

RESUMO

OBJECTIVE: A planar positron imaging system (PPIS) enables whole-body dynamic imaging of radiopharmaceuticals labeled with positron-emitting nuclides. We evaluated the difference in the brain and whole-body pharmacokinetics of (11)C-diphenylhydantoin ((11)C-DPH) between intravenous and duodenal administration in rats. METHODS: Male Wistar rats (8 weeks old, mean body weight 250 g) were examined under anesthesia. A tracer amount of (11)C-DPH (2 microg or less; about 5 MBq) was injected into the tail vein (n = 3) or duodenum (n = 3). Immediately following the administration, PPIS scans were obtained for 20 min. Regions of interest (ROIs) were set on the brain, heart, liver, intestinal field, and urinary bladder, identified on the integrated images. The relative uptake value (RUV, %) was calculated as the regional count divided by the whole-body count multiplied by 100. Sequential changes in the RUV for each ROI were analyzed for the brain and other organs. RESULTS: Following intravenous injection of (11)C-DPH, the RUV in the brain was 1.59 +/- 0.07%, 1.53 +/- 0.09%, 1.40 +/- 0.09%, and 1.38 +/- 0.08% at 5 min, 10 min, 15 min, and 20 min after the injection, respectively. After duodenal administration, the corresponding values were 0.54 +/- 0.16%, 1.01 +/- 0.12%, 1.43 +/- 0.24%, and 1.52 +/- 0.06%, respectively. The (11)C-DPH distribution was significantly lower at 5 min and 10 min following duodenal administration than after intravenous injection (P < 0.01). Radioactivity in the urinary bladder was identified by 20 min after both intravenous injection and duodenal administration. CONCLUSIONS: The present study demonstrated a difference in the brain distribution of (11)C-DPH between intravenous and duodenal administration in rats. Use of the PPIS is feasible for the evaluation of the pharmacokinetics in both the target organ and the whole body in small animals.


Assuntos
Encéfalo/diagnóstico por imagem , Elétrons , Fenitoína/farmacocinética , Animais , Radioisótopos de Carbono/administração & dosagem , Radioisótopos de Carbono/farmacocinética , Coração/diagnóstico por imagem , Injeções , Intestinos/diagnóstico por imagem , Fígado/diagnóstico por imagem , Masculino , Fenitoína/administração & dosagem , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/administração & dosagem , Compostos Radiofarmacêuticos/farmacocinética , Ratos , Distribuição Tecidual , Bexiga Urinária/diagnóstico por imagem , Imagem Corporal Total
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA