Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Regul Toxicol Pharmacol ; 144: 105489, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37659713

RESUMO

Local and systemic contamination caused by metal ions leaching from medical device materials is a significant and continuing health problem. The increasing need for verification and validation, and the imposition of stringent government regulations to ensure that the products comply with the quality, safety, and performance standards, have led regulatory bodies worldwide to strongly recommend the use of modeling and simulation tools to support medical device submissions. A previously published physiologically based toxicokinetic (PBTK) model, is here expanded and enriched by an additional separate tissue compartment to better resemble normal physiology and by the introduction of time-dependent functions to describe all biokinetic parameters. The new model is exercised in conjunction with state-of-the-art probabilistic, Monte Carlo methodology to calculate the predictions' confidence intervals and incorporate variability associated with toxicological biodistribution studies. The quantitative consistency of the model-derived predictions is validated against reported data following the implantation of nickel-containing cardiovascular devices in humans and minipigs. Finally, a new methodology for compartmental toxicological risk assessment is presented that can be used for forward or reverse dosimetry. Our work is aimed at providing a computational tool to optimize the device design characteristics and safeguard that the substances released do not exceed permissible exposure limits.


Assuntos
Pulmão , Modelos Biológicos , Humanos , Animais , Suínos , Distribuição Tecidual , Toxicocinética , Porco Miniatura , Medição de Risco
2.
FASEB J ; 35(2): e21279, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33484211

RESUMO

Exosomes are extracellular vesicles that are released from most cell types encapsulating specific molecular cargo. Exosomes serve as mediators of cell-to-cell and tissue-to-tissue communications under normal and pathological conditions. It has been shown that exosomes carrying muscle-specific miRNAs, myomiRs, are secreted from skeletal muscle cells in vitro and are elevated in the blood of muscle disease patients. The aim of this study was to investigate the secretion of exosomes encapsulating the four myomiRs from skeletal muscle tissues and to assess their role in inter-tissue communication between neighboring skeletal muscles in vivo. We demonstrate, for the first time, that isolated, intact skeletal muscle tissues secrete exosomes encapsulating the four myomiRs, miR-1, miR-133a, miR-133b, and miR-206. Notably, we show that the sorting of the four myomiRs within exosomes varies between skeletal muscles of different muscle fiber-type composition. miR-133a and miR-133b downregulation in TA muscles caused a reduction of their levels in neighboring skeletal muscles and in serum exosomes. In conclusion, our results reveal that skeletal muscle-derived exosomes encapsulate the four myomiRs, some of which enter the blood, while a portion is used for the local communication between proximal muscle tissues. These findings provide important evidence regarding novel pathways implicated in skeletal muscle function.


Assuntos
Comunicação Celular , Exossomos/metabolismo , MicroRNAs/metabolismo , Fibras Musculares Esqueléticas/metabolismo , Animais , Linhagem Celular , Células Cultivadas , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Células Satélites de Músculo Esquelético/metabolismo
3.
Ecotoxicol Environ Saf ; 232: 113213, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35085885

RESUMO

Current knowledge on the capacity of plastics as vectors of microorganisms and their ability to transfer microorganisms between different habitats (i.e. air, soil and river) is limited. The objective of this study was to characterise the evolution of the bacterial community adhered to environmental plastics [low-density polyethylene (LDPE)] across different environments from their point of use to their receiving environment destination in the sea. The study took place in a typical Mediterranean intermittent river basin in Larnaka, Cyprus, characterised by a large greenhouse area whose plastic debris may end up in the sea due to mismanagement. Five locations were selected to represent the environmental fate of greenhouse plastics from their use, through their abandonment in soil and subsequent transport to the river and the sea, taking samples of plastics and the surrounding environments (soil and water). The bacterial community associated with each sample was studied by 16S rRNA metabarcoding; also, the main physicochemical parameters in each environmental compartment were analysed to understand these changes. The identification and chemical changes in greenhouse plastics were tracked using Attenuated Total Reflection Fourier Transform Infra-red spectroscopy (ATR-FTIR). Scanning Electron Microscope (SEM) analysis demonstrated an evolution of the biofilm at each sampling location. ß-diversity studies showed that the bacterial community adhered to plastics was significantly different from that of the surrounding environment only in samples taken from aqueous environments (freshwater and sea) (p-value p-value > 0.05). The environmental parameters (pH, salinity, total nitrogen and total phosphorus) explained the differences observed at each location to a limited extent. Furthermore, bacterial community differences among samples were lower in plastics collected from the soil than in plastics taken from rivers and seawater. Six genera (Flavobacterium, Altererythrobacter, Acinetobacter, Pleurocapsa, Georgfuchsia and Rhodococcus) were detected in the plastic, irrespective of the sampling location, confirming that greenhouse plastics can act as possible vectors of microorganisms between different environments: from their point of use, through a river system to the final coastal receiving environment. In conclusion, this study confirms the ability of greenhouse plastics to transport bacteria, including pathogens, between different environments. Future studies should evaluate these risks by performing complete sequencing metagenomics to decipher the functions of the plastisphere.


Assuntos
Plásticos , Água do Mar , Bactérias/genética , RNA Ribossômico 16S/genética , Rios , Água do Mar/microbiologia
4.
Hum Mol Genet ; 26(17): 3285-3302, 2017 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-28637233

RESUMO

Myotonic dystrophy type 1 (DM1) is the most common form of adult-onset muscular dystrophy, which is characterised by progressive muscle wasting and the discovery of reliable blood-based biomarkers could be useful for the disease progress monitoring. There have been some reports showing that the presence of specific miRNAs in blood correlates with DM1. In one of these, our group identified four muscle-specific miRNAs, miR-1, miR-133a, miR-133b and miR-206, which correlated with the progression of muscle wasting observed in DM1 patients. The levels of the four muscle-specific miRNAs were elevated in the serum of DM1 patients compared to healthy participants and were also elevated in the serum of progressive muscle wasting DM1 patients compared to disease-stable DM1 patients. The aim of this work was to characterise the ontology of these four muscle-specific miRNAs in the blood circulation of DM1 patients. Here we show that the four muscle-specific miRNAs are encapsulated within exosomes isolated from DM1 patients. Our results show for the first time, the presence of miRNAs encapsulated within exosomes in blood circulation of DM1 patients. More interestingly, the levels of the four exosomal muscle-specific miRNAs are associated with the progression of muscle wasting in DM1 patients. We propose that exosomal muscle-specific miRNAs may be useful molecular biomarkers for monitoring the progress of muscle wasting in DM1 patients. There has been a growing interest regarding the clinical applications of exosomes and their role in prognosis and therapy of various diseases and the above results contribute towards this way.


Assuntos
Distrofia Miotônica/genética , Distrofia Miotônica/patologia , Biomarcadores/sangue , Progressão da Doença , Exossomos , Humanos , MicroRNAs/sangue , MicroRNAs/metabolismo , Atrofia Muscular/genética , Atrofia Muscular/patologia , Doenças Musculares/genética , Doenças Musculares/patologia , Distrofias Musculares/genética , Distrofias Musculares/patologia , Distrofia Miotônica/metabolismo
5.
ACS Biomater Sci Eng ; 10(4): 2534-2551, 2024 04 08.
Artigo em Inglês | MEDLINE | ID: mdl-38525821

RESUMO

In vitro testing methods offer valuable insights into the corrosion vulnerability of metal implants and enable prompt comparison between devices. However, they fall short in predicting the extent of leaching and the biodistribution of implant byproducts under in vivo conditions. Physiologically based toxicokinetic (PBTK) models are capable of quantitatively establishing such correlations and therefore provide a powerful tool in advancing nonclinical methods to test medical implants and assess patient exposure to implant debris. In this study, we present a multicompartment PBTK model and a simulation engine for toxicological risk assessment of vascular stents. The mathematical model consists of a detailed set of constitutive equations that describe the transfer of nickel ions from the device to peri-implant tissue and circulation and the nickel mass exchange between blood and the various tissues/organs and excreta. Model parameterization was performed using (1) in-house-produced data from immersion testing to compute the device-specific diffusion parameters and (2) full-scale animal in situ implantation studies to extract the mammalian-specific biokinetic functions that characterize the time-dependent biodistribution of the released ions. The PBTK model was put to the test using a simulation engine to estimate the concentration-time profiles, along with confidence intervals through probabilistic Monte Carlo, of nickel ions leaching from the implanted devices and determine if permissible exposure limits are exceeded. The model-derived output demonstrated prognostic conformity with reported experimental data, indicating that it may provide the basis for the broader use of modeling and simulation tools to guide the optimal design of implantable devices in compliance with exposure limits and other regulatory requirements.


Assuntos
Modelos Biológicos , Níquel , Animais , Humanos , Níquel/toxicidade , Distribuição Tecidual , Toxicocinética , Stents/efeitos adversos , Íons , Mamíferos
6.
ACS Biomater Sci Eng ; 9(8): 4747-4760, 2023 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-37480152

RESUMO

A recent U.S. Food and Drug Administration report presented the currently available scientific information related to biological response to metal implants. In this work, a multilevel approach was employed to assess the implant-induced and biocorrosion-related inflammation in the adjacent vascular tissue using a mouse stent implantation model. The implications of biocorrosion on peri-implant tissue were assessed at the macroscopic level via in vivo imaging and histomorphology. Elevated matrix metalloproteinase activity, colocalized with the site of implantation, and histological staining indicated that stent surface condition and implantation time affect the inflammatory response and subsequent formation and extent of neointima. Hematological measurements also demonstrated that accumulated metal particle contamination in blood samples from corroded-stetted mice causes a stronger immune response. At the cellular level, the stent-induced alterations in the nanostructure, cytoskeleton, and mechanical properties of circulating lymphocytes were investigated. It was found that cells from corroded-stented samples exhibited higher stiffness, in terms of Young's modulus values, compared to noncorroded and sham-stented samples. Nanomechanical modifications were also accompanied by cellular remodeling, through alterations in cell morphology and stress (F-actin) fiber characteristics. Our analysis indicates that surface wear and elevated metal particle contamination, prompted by corroded stents, may contribute to the inflammatory response and the multifactorial process of in-stent restenosis. The results also suggest that circulating lymphocytes could be a novel nanomechanical biomarker for peri-implant tissue inflammation and possibly the early stage of in-stent restenosis. Large-scale studies are warranted to further investigate these findings.


Assuntos
Reestenose Coronária , Estados Unidos , Humanos , Reestenose Coronária/etiologia , Reestenose Coronária/patologia , Vasos Coronários/patologia , Stents/efeitos adversos , Metais , Inflamação/complicações , Inflamação/patologia
7.
Front Physiol ; 12: 708278, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34867435

RESUMO

Skeletal muscle growth and maintenance depend on two tightly regulated processes, myogenesis and muscle regeneration. Both processes involve a series of crucial regulatory molecules including muscle-specific microRNAs, known as myomiRs. We recently showed that four myomiRs, miR-1, miR-133a, miR-133b, and miR-206, are encapsulated within muscle-derived exosomes and participate in local skeletal muscle communication. Although these four myomiRs have been extensively studied for their function in muscles, no information exists regarding their endogenous and exosomal levels across age. Here we aimed to identify any age-related changes in the endogenous and muscle-derived exosomal myomiR levels during acute skeletal muscle growth. The four endogenous and muscle-derived myomiRs were investigated in five skeletal muscles (extensor digitorum longus, soleus, tibialis anterior, gastrocnemius, and quadriceps) of 2-week-1-year-old wild-type male mice. The expression of miR-1, miR-133a, and miR-133b was found to increase rapidly until adolescence in all skeletal muscles, whereas during adulthood it remained relatively stable. By contrast, endogenous miR-206 levels were observed to decrease with age in all muscles, except for soleus. Differential expression of the four myomiRs is also inversely reflected on the production of two protein targets; serum response factor and connexin 43. Muscle-derived exosomal miR-1, miR-133a, and miR-133b levels were found to increase until the early adolescence, before reaching a plateau phase. Soleus was found to be the only skeletal muscle to release exosomes enriched in miR-206. In this study, we showed for the first time an in-depth longitudinal analysis of the endogenous and exosomal levels of the four myomiRs during skeletal muscle development. We showed that the endogenous expression and extracellular secretion of the four myomiRs are associated to the function and size of skeletal muscles as the mice age. Overall, our findings provide new insights for the myomiRs' significant role in the first year of life in mice.

8.
Nanotheranostics ; 5(1): 113-124, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33391978

RESUMO

Treatment of breast cancer underwent extensive progress in recent years with molecularly targeted therapies. However, non-specific pharmaceutical approaches (chemotherapy) persist, inducing severe side-effects. Phytochemicals provide a promising alternative for breast cancer prevention and treatment. Specifically, resveratrol (res) is a plant-derived polyphenolic phytoalexin with potent biological activity but displays poor water solubility, limiting its clinical use. Here we have developed a strategy for delivering res using a newly synthesized nano-carrier with the potential for both diagnosis and treatment. Methods: Res-loaded nanoparticles were synthesized by the emulsion method using Pluronic F127 block copolymer and Vitamin E-TPGS. Nanoparticle characterization was performed by SEM and tunable resistive pulse sensing. Encapsulation Efficiency (EE%) and Drug Loading (DL%) content were determined by analysis of the supernatant during synthesis. Nanoparticle uptake kinetics in breast cancer cell lines MCF-7 and MDA-MB-231 as well as in MCF-10A breast epithelial cells were evaluated by flow cytometry and the effects of res on cell viability via MTT assay. Results: Res-loaded nanoparticles with spherical shape and a dominant size of 179±22 nm were produced. Res was loaded with high EE of 73±0.9% and DL content of 6.2±0.1%. Flow cytometry revealed higher uptake efficiency in breast cancer cells compared to the control. An MTT assay showed that res-loaded nanoparticles reduced the viability of breast cancer cells with no effect on the control cells. Conclusions: These results demonstrate that the newly synthesized nanoparticle is a good model for the encapsulation of hydrophobic drugs. Additionally, the nanoparticle delivers a natural compound and is highly effective and selective against breast cancer cells rendering this type of nanoparticle an excellent candidate for diagnosis and therapy of difficult to treat mammary malignancies.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Portadores de Fármacos , Micelas , Resveratrol/uso terapêutico , Antineoplásicos/uso terapêutico , Feminino , Humanos , Células MCF-7
9.
Mol Ther Methods Clin Dev ; 23: 169-183, 2021 Dec 10.
Artigo em Inglês | MEDLINE | ID: mdl-34703840

RESUMO

Myotonic dystrophy type 1 (DM1) is the most common adult-onset muscular dystrophy, primarily characterized by muscle wasting and weakness. Many biomarkers already exist in the rapidly developing biomarker research field that aim to improve patients' care. Limited work, however, has been performed on rare diseases, including DM1. We have previously shown that specific microRNAs (miRNAs) can be used as potential biomarkers for DM1 progression. In this report, we aimed to identify novel serum-based biomarkers for DM1 through high-throughput next-generation sequencing. A number of miRNAs were identified that are able to distinguish DM1 patients from healthy individuals. Two miRNAs were selected, and their association with the disease was validated in a larger panel of patients. Further investigation of miR-223-3p, miR-24-3p, and the four previously identified miRNAs, miR-1-3p, miR-133a-3p, miR-133b-3p, and miR-206-3p, showed elevated levels in a DM1 mouse model for all six miRNAs circulating in the serum compared to healthy controls. Importantly, the levels of miR-223-3p, but not the other five miRNAs, were found to be significantly downregulated in five skeletal muscles and heart tissues of DM1 mice compared to controls. This result provides significant evidence for its involvement in disease manifestation.

10.
ACS Appl Energy Mater ; 2(3): 2276-2287, 2019 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-31168522

RESUMO

We present the functionalization process of a conductive and transparent CuAlO2/Cu-O hole-transporting layer (HTL). The CuAlO2/Cu-O powders were developed by flame spray pyrolysis and their stabilized dispersions were treated by sonication and centrifugation methods. We show that when the supernatant part of the treated CuAlO2/Cu-O dispersions is used for the development of CuAlO2/Cu-O HTLs the corresponding inverted perovskite-based solar cells show improved functionality and power conversion efficiency of up to 16.3% with negligible hysteresis effect.

11.
J Appl Biomater Funct Mater ; 16(4): 230-240, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29974806

RESUMO

Background Wear and corrosion have been identified as two of the major forms of medical implant failures. This study aims to improve the surface, protective and tribological characteristics of bare metals used for medical implants, so as to improve scratch resistance and increase lifetime. Methods Hydrogenated amorphous carbon (a-C:H) films were deposited, using plasma enhanced chemical vapor deposition (PECVD), on stainless steel (SS), titanium (Ti) and niobium (Nb) metal plates. Nanomechanical and nanotribological responses were investigated before and after a-C:H deposition. Film thickness and density were quantified through X-ray reflectivity, and surface morphology before and after deposition were measured using atomic force microscopy, whereas the tribomechanical characteristics were probed using instrumented indentation. Results and conclusions Films of approximately 40 nm in thickness and density of 1.7 g/cm3 were deposited. The a-C:H films reduce the roughness and coefficient of friction while improving the tribomechanical response compared with bare metals for Ti, SS and Nb plates. The very good tribomechanical properties of a-C:H make it a promising candidate material for protective coating on metallic implants.


Assuntos
Materiais Biocompatíveis/química , Nanoestruturas/química , Nióbio/química , Aço Inoxidável/química , Titânio/química , Fenômenos Biomecânicos , Carbono/química , Hidrogênio/química , Membranas Artificiais , Tamanho da Partícula , Propriedades de Superfície
12.
J Biomed Mater Res A ; 104(1): 227-38, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26362825

RESUMO

The popularity of vascular stents continues to increase for a variety of applications, including coronary, lower limb, renal, carotid, and neurovascular disorders. However, their clinical effectiveness is hindered by numerous postdeployment complications, which may stimulate inflammatory and fibrotic reactions. The purpose of this study was to evaluate the vessel inflammatory response via in vivo imaging in a mouse stent implantation model. Corroded and noncorroded self-expanding miniature nitinol stents were implanted in mice abdominal aortas, and novel in vivo imaging techniques were used to assess trafficking and accumulation of fluorescent donor monocytes as well as cellular proliferation at the implantation site. Monocytes were quantitatively tracked in vivo and found to rapidly clear from circulation within hours after injection. Differences were found between the test groups with respect to the numbers of recruited monocytes and the intensity of the resulting fluorescent signal. Image analysis also revealed a subtle increase in matrix metalloproteinase activity in corroded compared with the normal stented aortas. In conclusion, this study has been successful in developing a murine stent inflammation model and applying novel in vivo imaging tools and methods to monitor the complex biological processes of the host vascular wall response.


Assuntos
Aorta Abdominal/patologia , Inflamação/patologia , Monitorização Fisiológica , Stents , Ligas/farmacologia , Animais , Aorta Abdominal/efeitos dos fármacos , Aorta Abdominal/enzimologia , Separação Celular , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/patologia , Corrosão , Modelos Animais de Doenças , Fluorescência , Masculino , Metaloproteinases da Matriz/metabolismo , Metais/sangue , Camundongos , Monócitos/citologia , Monócitos/efeitos dos fármacos
13.
J Mech Behav Biomed Mater ; 40: 240-251, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25255419

RESUMO

In-stent restenosis (ISR) remains a significant limitation despite the considerable previous clinical and investigative emphasis on the problem. Complications arising from the interaction of stent materials with the surrounding vessel wall as well as from the mechanical forces developing after implantation, play an important role in the development of ISR. To investigate the relation between mechanical factors and stent structural integrity, and to identify any structural weakness points on the geometry of commercially available Stainless Steel and Cobalt-Chromium stents, accelerated pulsatile durability tests were carried out in a simulated physiological environment. Potential spatial variations in the mechanical properties on stent struts and their role in the observed premature failures of the stent devices during operation were also examined. Fretting wear and fatigue-induced fractures were found on stent surfaces after exposure to cyclic loading similar to that arising in vivo. Nanoindentation studies performed on various locations along the stent struts have shown that the hardness of specific stent locations significantly increases after mechanical expansion. The increase in hardness was associated with a reduction of the material's ability to dissipate energy in plastic deformations, therefore an increased vulnerability to fracture and fatigue. We conclude that the locations of fatigue fractures in stent struts are controlled not only by the geometrically-driven stress concentrations developing during cyclic loading but also by the local material mechanical changes that are imparted on various parts of the stent during the deployment process.


Assuntos
Cromo , Cobalto , Aço Inoxidável , Stents , Constrição Patológica , Teste de Materiais , Estresse Mecânico
14.
J Mech Behav Biomed Mater ; 20: 227-36, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23313643

RESUMO

Preliminary studies have revealed that some stents undergo corrosion and fatigue-induced fracture in vivo, with significant release of metallic ions into surrounding tissues. A direct link between corrosion and in-stent restenosis has not been clearly established; nonetheless in vitro studies have shown that relatively high concentrations of heavy metal ions can stimulate both inflammatory and fibrotic reactions, which are the main steps in the process of restenosis. To isolate the mechanical effects from the local biochemical effects, accelerated biomechanical testing was performed on single and overlapping Nickel-Titanium (NiTi) stents subjected to various degrees of curvature. Post testing, stents were evaluated using Scanning Electron Microscopy (SEM) to identify the type of surface alterations. Fretting wear was observed in overlapping cases, in both straight and curved configurations. Stent strut fractures occurred in the presence of geometric curvature. Fretting wear and fatigue fractures observed on stents following mechanical simulation were similar to those from previously reported human stent explants. It has been shown that biomechanical factors such as arterial curvature combined with stent overlapping enhance the incidence and degree of wear and fatigue fracture when compared to single stents in a straight tube configuration.


Assuntos
Ligas/química , Prótese Vascular , Vasos Coronários/cirurgia , Stents , Corrosão , Módulo de Elasticidade , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Resistência à Tração
15.
J Biomech ; 42(15): 2454-7, 2009 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-19674750

RESUMO

Glaucoma is a common cause of blindness. Studies of this disease can involve collection of aqueous humor (AH) fluid from eyes of patients undergoing surgery, which involves aspirating a small fluid volume from the anterior region of the eye through a fine-bore needle. Unfortunately, the composition of the AH is spatially non-uniform in the eye, and thus the composition of the aspirated fluid is uncertain. Our goal was to numerically simulate the AH aspiration process to determine where the aspirated fluid was being collected from and thus gain insight into the composition of the collected fluid. A 3D computational model of the anterior region of the human eye was created and the Navier-Stokes equations were numerically solved during the aspiration process for a set of typical (baseline) conditions: 40 microl aspirated volume and needle placement in the central anterior chamber. We also ran variations of this baseline simulation. The main finding was that the aspirated fluid comes from a very localized region around the needle tip, so that for typical conditions, almost no aspirated fluid is withdrawn from the angle region of the anterior chamber. This is important because the AH in this angle region is protein-rich and directly interacts with the tissues that control fluid drainage from the eye. Recommendations for standardizing aspiration conditions are given.


Assuntos
Humor Aquoso/fisiologia , Modelos Biológicos , Fenômenos Fisiológicos Oculares , Simulação por Computador , Humanos , Reologia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA