Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Brachytherapy ; 23(2): 115-122, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38040605

RESUMO

PURPOSE: To evaluate the possibility of dose escalation and reduction of fraction number in cervical brachytherapy using a gel spacer. MATERIAL AND METHODS: Twenty patients with uterine cervical cancer treated with image-guided adaptive brachytherapy (IGABT) were selected. Hyaluronic acid gel injection (HGI) was performed in the rectovaginal and vesicouterine septum for 10 patients. The other ten patients were not with HGI. Both groups were treated with IGABT involving tandem/ovoid or cylindrical applicators along with additional interstitial needles. Dose distributions approved by radiation oncologists were retrospectively analyzed, and a dose summation of 45 Gy/25 of external beam radiation therapy and IGABT was performed. Dose constraints for D2cc of bladder, rectum, and sigmoid were 80, 70, and 70 Gy, respectively. Equivalent dose in 2-Gy fractions calculations used α/ß = 10 Gy for high-risk clinical target volume (CTVHR) D90 and α/ß = 3 Gy for organs at risks (OARs). As a planning study, dose distribution rescaling was conducted to deliver as much dose to CTVHR D90 as possible within the dose constraint limitation for OARs when IGABT was performed for four, three, and two fractions in both groups. RESULTS: The median CTVHR D90 was >80 Gy in the non-HGI group and >85 Gy in the HGI group for virtual two and three fractions. Rectum D2cc was significantly lower in the HGI group for three fractions (p < 0.01). CONCLUSIONS: In the HGI group, adequate dose delivery to CTVHR could be achieved with a reduced IGABT fraction number while meeting the dose constraints of OARs.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Feminino , Humanos , Dosagem Radioterapêutica , Braquiterapia/métodos , Estudos Retrospectivos , Neoplasias do Colo do Útero/radioterapia , Reto , Órgãos em Risco , Planejamento da Radioterapia Assistida por Computador , Ácido Hialurônico
2.
Brachytherapy ; 2024 Jul 27.
Artigo em Inglês | MEDLINE | ID: mdl-39069397

RESUMO

PURPOSE: We developed a 3D-printed phantom model for ultrasound-guided caudal block for educational or training purposes because there have been no reports of the 3D-printed phantom model for ultrasound-guided caudal block. This study aimed to identify the needs for the phantom model in a lecture and demonstration at hands-on training (HoT) to promote the use of caudal block for sufficient pain control during high-dose-rate intracavitary/interstitial brachytherapy for gynecological cancers. MATERIALS AND METHODS: The sacrum and formwork were designed by computed tomography imaging. A 3D-modeling software program was used to create the sacrum and formwork. The phantom was solidified by injecting a gelatin-based gel. Ultrasonography was performed to visualize the sacral hiatus and puncture needle in the phantom. In October 2023, 10 radiation oncologists who did not perform caudal block in daily clinical practice from ten Japanese facilities participated in HoT on ultrasound-guided caudal block. After the HoT, questionnaires were distributed to each participant, and feedback was obtained through online channels. RESULTS: After receiving a lecture and demonstration on ultrasound-guided caudal block, 90% of the respondents would like to practice the procedure in their daily clinical practice. Moreover, 100% of the respondents would like to use the 3D-printed phantom model for ultrasound-guided caudal block for educational or training purposes. CONCLUSION: The 3D-printed phantom model for ultrasound-guided caudal block can be used in training and is in demand for facilities introducing caudal block.

3.
Cancers (Basel) ; 16(13)2024 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-39001446

RESUMO

PURPOSE: Analyzing dose distributions to regional lymph-node metastases (RLNMs) in locally advanced cervical cancer (LACC) patients undergoing intracavitary and interstitial hybrid brachytherapy (IC/IS). METHODS: Dose distributions of eleven LACC patients with 38 RLNMs, and who received 38 IC/IS sessions were analyzed in EQD2, considering RLNM positions and ipsilateral interstitial needles; these RLNMs, excepting the para-aortic region, were classified into four groups. RESULTS: RLNMs had a median of two ipsilateral interstitial needles per session. Significant differences were observed in total RLNM D90, depending on whether the position was cranial or caudal of the uterine base (85.5 vs. 378.9 cGy, p < 0.0001), and whether the RLNM D90 was associated with a number of ipsilateral interstitial needles between 0-1 or 2 or more (68.4 vs. 112.2 cGy, p = 0.006) per session. At each session, Group 1 RLNMs (cranial of the uterine base, 0-1 ipsilateral interstitial needle) had a mean D90 of 21.1 cGy; Group 2 (cranial, 2 or more), 73.8; Group 3 (caudal, 0-1), 94.7; and Group 4 (caudal, 2 or more), 136.1. CONCLUSION: RLNMs located caudal of the uterine base associated with two or more ipsilateral interstitial needles in IC/IS had a higher dose contribution, which should be considered when calculating the RLNMs' dose of external beam boost irradiation.

4.
J Radiat Res ; 65(3): 323-327, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38544297

RESUMO

This study assessed the significance of hands-on-training (HoT) and questionnaire-based surveys on 3D image-guided brachytherapy (3D-IGBT) and a combination of intracavitary and interstitial brachytherapy, the so-called 'hybrid' BT (HBT), in uterine cervical cancer. In October 2023, 29 radiation oncologists, nurses, radiologic technologists and medical physicists from 10 Japanese facilities participated in an HoT on 3D-IGBT and HBT. Questionnaires were distributed to each participant before and after the HoT, and feedback was obtained through online channels. The questionnaire response rate was 83% (24/29), with at least one participant responding from each facility. 'Insertion of applicators and needles', 'human resource shortage' and 'pain relief and sedation' were the primary concerns of radiation oncologists. 'Applicator reconstruction', ' optimization of dwell positions', ' treatment planning' and ' human resource shortages ' were the primary concerns of radiological technologists and medical physicists. The HoT content was adjusted according to the results of preliminary surveys. The concerns expressed by the participants were addressed during the lectures and practical training. Significant reductions in anxiety were observed toward all items of the 10-point self-assessment after the HoT, regardless of the profession. The average score on satisfaction with the HoT (on a 10-point scale) was 9.52 (minimum of 8 and maximum of 10). In conclusion, HoT tailored in response to a pre-questionnaire-based survey effectively reduced participants' anxiety regarding the implementation of 3D-IGBT and HBT.


Assuntos
Ansiedade , Braquiterapia , Radioterapia Guiada por Imagem , Humanos , Inquéritos e Questionários , Feminino , Neoplasias do Colo do Útero/radioterapia
5.
EJNMMI Rep ; 8(1): 6, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748042

RESUMO

PURPOSE: To determine the efficacy and safety of target volume determination by 18F-fluorodeoxyglucose positron emission tomography-computed tomography (PET-CT) for intensity-modulated radiation therapy (IMRT) for locally advanced head and neck squamous cell carcinoma (HNSCC) extending into the oral cavity or oropharynx. METHODS: We prospectively treated 10 consecutive consenting patients with HNSCC using IMRT, with target volumes determined by PET-CT. Gross tumor volume (GTV) and clinical target volume (CTV) at the oral level were determined by two radiation oncologists for CT, magnetic resonance imaging (MRI), and PET-CT. Differences in target volume (GTVPET, GTVCT, GTVMRI, CTVPET, CTVCT, and CTVMRI) for each modality and the interobserver variability of the target volume were evaluated using the Dice similarity coefficient and Hausdorff distance. Clinical outcomes, including acute adverse events (AEs) and local control were evaluated. RESULTS: The mean GTV was smallest for GTVPET, followed by GTVCT and GTVMRI. There was a significant difference between GTVPET and GTVMRI, but not between the other two groups. The interobserver variability of target volume with PET-CT was significantly less than that with CT or MRI for GTV and tended to be less for CTV, but there was no significant difference in CTV between the modalities. Grade ≤ 3 acute dermatitis, mucositis, and dysphagia occurred in 55%, 88%, and 22% of patients, respectively, but no grade 4 AEs were observed. There was no local recurrence at the oral level after a median follow-up period of 37 months (range, 15-55 months). CONCLUSIONS: The results suggest that the target volume determined by PET-CT could safely reduce GTV size and interobserver variability in patients with locally advanced HNSCC extending into the oral cavity or oropharynx undergoing IMRT. Trial registration UMIN, UMIN000033007. Registered 16 jun 2018, https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000037631.

6.
Cancer Diagn Progn ; 3(2): 257-263, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36875310

RESUMO

BACKGROUND/AIM: Radiotherapy (RT) has been rarely reported as a cause of tumor lysis syndrome (TLS). Therefore, the patient characteristics and details of RT-induced TLS remain unclear, which may delay diagnosis. Herein, we report a case of palliative RT-induced severe TLS in a patient with multiple myeloma (MM) with skin involvement along with literature review. CASE REPORT: A 75-year-old female with MM was referred to our department in February 2021 because of swelling and pruritus of the bulky tumor on her right breast and severe left leg pain. She had received chemotherapies and autologous peripheral blood stem cell transplantations since October 2012. We administered palliative RT (a single 8 Gy fraction) to the right breast, left tibia, and femur. On day 7 after RT, a shrinkage effect was observed on the right breast lesion, and left leg pain was relieved. Her laboratory results showed hyperuricemia, hyperphosphatemia, and hypercreatininemia. Initially, we considered acute renal failure (ARF) due to MM progression and planned for a follow-up after 1 week. On day 14 after RT completion, she experienced vomiting and anorexia. Her laboratory results became worse. She was admitted with the diagnosis of TLS and received intravenous fluid hydration and allopurinol. Unfortunately, the evolution was marked by severe clinical deterioration with anuria and coma, leading to death on day 35 after RT. CONCLUSION: It is important to determine whether ARF is due to MM progression or TLS. The occurrence of TLS should be considered in the case of a rapidly shrinking bulky tumor while receiving palliative RT.

7.
Clin Transl Radiat Oncol ; 42: 100659, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37519921

RESUMO

We first used MucoUp®, a hyaluronic acid used in endoscopic resection, as a spacer in brachytherapy. In five cervical cancer patients, MucoUp® insertion increased a 90% dose of the high-risk CTV to over 80 Gy while decreasing the dose of organs at risk. No related adverse events were observed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA