Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 26
Filtrar
1.
Anesth Analg ; 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39093817

RESUMO

BACKGROUND: Mixed venous oxygen saturation (SvO 2 ) is a critical variable in the assessment of oxygen supply and demand but is rarely used in children due to the invasive nature of pulmonary artery catheters. The aim of this prospective, observational study was to investigate the accuracy of noninvasively measured SvO 2 acquired by the novel capnodynamic method, based on differential Fick equation (Capno-SvO 2 ), against gold standard CO-oximetry. METHODS: Capno-SvO 2 was compared to SvO 2 measured by pulmonary artery blood gas CO-oximetry in children undergoing cardiac catheter interventions and subjected to moderate hemodynamic challenges. Bland-Altman analysis was used to describe the agreement of absolute values between CO-oximetry and Capno-SvO 2 , and a concordance rate was calculated to evaluate the ability of Capno-SvO 2 to track change. RESULTS: Twenty-five procedures were included in the study. Capno-SvO 2 showed a bias toward CO-oximetry of +3 percentage points; upper and lower limits of agreement were +11 percentage points (95% confidence interval [CI], 9-14) and -5 percentage points (95% CI, -8 to -3), respectively. The concordance rate was 92% (95% CI, 89-96). CONCLUSIONS: In conclusion, this first clinical application of a novel concept for noninvasive SvO 2 monitoring without the need for a pulmonary artery catheter indicates that Capno-SvO 2 generates absolute values and trending capacity in close agreement with the gold standard reference method.

2.
Paediatr Anaesth ; 34(3): 251-258, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38055609

RESUMO

BACKGROUND: Capnodynamic lung function monitoring generates variables that may be useful for pediatric perioperative ventilation. AIMS: Establish normal values for end-expiratory lung volume CO2 in healthy children undergoing anesthesia and to compare these values to previously published values obtained with alternative end-expiratory lung volume methods. The secondary aim was to investigate the ability of end-expiratory lung volume CO2 to react to positive end-expiratory pressure-induced changes in end-expiratory lung volume. In addition, normal values for associated volumetric capnography lung function variables were examined. METHODS: Fifteen pediatric patients with healthy lungs (median age 8 months, range 1-36 months) undergoing general anesthesia were examined before start of surgery. Tested variables were recorded at baseline positive end-expiratory pressure 3 cmH2 O, 1 and 3 min after positive end-expiratory pressure 10 cmH2 O and 3 min after returning to baseline positive end-expiratory pressure 3 cmH2 O. RESULTS: Baseline end-expiratory lung volume CO2 was 32 mL kg-1 (95% CI 29-34 mL kg-1 ) which increased to 39 mL kg-1 (95% CI 35-43 mL kg-1 , p < .0001) and 37 mL kg-1 (95% CI 34-41 mL kg-1 , p = .0003) 1 and 3 min after positive end-expiratory pressure 10 cmH2 O, respectively. End-expiratory lung volume CO2 returned to baseline, 33 mL kg-1 (95% CI 29-37 mL kg-1 , p = .72) 3 min after re-establishing positive end-expiratory pressure 3 cmH2 O. Airway dead space increased from 1.1 mL kg-1 (95% CI 0.9-1.4 mL kg-1 ) to 1.4 (95% CI 1.1-1.8 mL kg-1 , p = .003) and 1.5 (95% CI 1.1-1.8 mL kg-1 , p < .0001) 1 and 3 min after positive end-expiratory pressure 10 cmH2 O, respectively, and 1.2 mL kg-1 (95% CI 0.9-1.4 mL kg-1 , p = .08) after 3 min of positive end-expiratory pressure 3 cmH2 O. Additional volumetric capnography and lung function variables showed no major changes in response to positive end-expiratory pressure variations. CONCLUSIONS: Capnodynamic noninvasive and continuous end-expiratory lung volume CO2 values assessed during anesthesia in children were in close agreement with previously reported end-expiratory lung volume values generated by alternative methods. Furthermore, positive end-expiratory pressure changes resulted in physiologically expected end-expiratory lung volume CO2 responses in a timely manner, suggesting that it can be used to trend end-expiratory lung volume changes during anesthesia.


Assuntos
Dióxido de Carbono , Respiração , Humanos , Criança , Lactente , Pré-Escolar , Medidas de Volume Pulmonar , Respiração com Pressão Positiva , Pulmão , Anestesia Geral , Volume de Ventilação Pulmonar
3.
Paediatr Anaesth ; 34(9): 919-925, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38415881

RESUMO

Organization of healthcare strongly differs between European countries and results in country-specific requirements in postgraduate medical training. Within the European Union (EU), the European Board of Anaesthesiology has set recommendations of training for the Specialty of Anaesthesiology including standards for Postgraduate Medical Specialist training including a description for providing service in pediatric anesthesia. However, these standards are advisory and not mandatory. Here we aimed to review the current state and associated challenges of pediatric anesthesia training in Europe. We report an important country-specific variability both in training and regulations of practice of pediatric anesthesia in the EU and in the United Kingdom. The requirements for training in pediatric anesthesia varies between nothing specified (Belgium) or providing anesthesia with direct supervision to a minimum of 50 cases below 5 years of age (Germany) to 3-6 month clinical practice in a specialized pediatric hospital (France). Likewise, the regulations for providing anesthesia to children varies from no regulations at all (Belgium) to age specific requirements and centralization of all children below 4 years of age to specified centers (United Kingdom). Officially recognized pediatric anesthesia fellowship programs are not available in most countries of Europe. It remains unclear if and how country-specific differences in pediatric anesthesia training are associated with clinical outcomes in pediatric perioperative care. There is converging interest and support for the establishment of a European pediatric anesthesia curriculum.


Assuntos
Anestesiologia , Pediatria , Humanos , Europa (Continente) , Anestesiologia/educação , Anestesiologia/normas , Pediatria/educação , Pediatria/normas , Criança , Anestesia/normas , Pré-Escolar , Educação de Pós-Graduação em Medicina , Anestesia Pediátrica
4.
Acta Anaesthesiol Scand ; 67(7): 953-963, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37184945

RESUMO

BACKGROUND: The capnodynamic method, based on Volumetric capnography and differential Fick mathematics, assess cardiac output in mechanically ventilated subjects. Capnodynamic and established hemodynamic monitoring parameters' capability to depict alterations in blood volume were investigated in a model of standardized hemorrhage, followed by crystalloid and blood transfusion. METHODS: Ten anesthetized piglets were subjected to controlled hemorrhage (450 mL), followed by isovolemic crystalloid bolus and blood re-transfusion. Intravascular blood volume, and all hemodynamic variables, were determined twice after each intervention. The investigated hemodynamic variables were: cardiac output and stroke volume for capnodynamics and pulse contour analysis, respectively, pulse pressure and stroke volume variability and mean arterial pressure. One-way ANOVA and Tukey's test for multiple comparisons were used to identify significant changes. Trending was assessed by correlation and concordance. RESULT: Concordance against intravascular volume changes for capnodynamic cardiac output and stroke volume were 96 and 94%, with correlations r = .78 and .68, (p < .0001) with significant changes for 6 and 5 of the 6 measuring points, respectively. Mean arterial pressure and pulse pressure variation had a concordance of 85% and 87%, r = .67 (p < .0001) and r = -.45 (p < .0001), respectively, and both changed significantly for 3 of 6 measuring points. Pulse contour stroke volume variation, stroke volume and cardiac output, showed concordance and correlation of 76%, r = -.18 (p = .11), 63%, r = .28 (p = .01) and 50%, r = .31 (p = .007), respectively and significant change for 1, 1 and 0 of the measuring points, respectively. CONCLUSION: Capnodynamic cardiac output and stroke volume did best depict the changes in intravascular blood volume. Pulse contour parameters did not follow volume changes in a reliable way.


Assuntos
Hidratação , Hemodinâmica , Animais , Suínos , Hidratação/métodos , Débito Cardíaco , Volume Sistólico , Pressão Sanguínea , Volume Sanguíneo , Hemorragia
5.
Acta Anaesthesiol Scand ; 67(7): 936-942, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37354078

RESUMO

BACKGROUND: Patients with Covid-19 respiratory failure present with hypoxemia, often in combination with hypercapnia. In this prospective, observational study we examined the effect of removing external dead space (DS) on CO2 -homeostasis in mechanically ventilated Covid-19 patients. In addition, volumetric capnography was validated for its ability to estimate external DS volume using in vitro measured DS volumes as reference. METHODS: In total, 10 patients with acute respiratory distress syndrome from Covid-19 were included. Volumetric capnography, mechanical ventilation, and arterial blood gas data were analyzed before and after removal of external DS and analyzed for potentially significant changes in response to DS removal. Measurements of external DS were obtained in circuit using volumetric capnography and compared to actual measured DS volumes off the circuit. RESULTS: After the removal of external DS, the alveolar minute ventilation and CO2 elimination improved, notwithstanding unchanged respiratory rate and tidal volumes. The increase in CO2 elimination was associated with a decrease in arterial CO2 partial pressure (PaCO2 ). The volumetric capnography method for assessment of external DS showed a low bias of -9 mL (lower limit of agreement -40, 95% CI -60 to -20 mL, upper limit of agreement 21 mL, 95% CI: 1-40 mL) and a percentage error of 48% compared to absolute values measured in vitro. CONCLUSION: Removal of external DS increased alveolar minute ventilation and CO2 elimination in Covid-19 patients with respiratory failure in the current study. This was associated with a decrease in PaCO2 . This may indicate a decreased CO2 production due to decreased work of breathing and more effective gas-exchange in response to DS removal. In addition, volumetric capnography appears to be a clinically feasible method for continuous measurement of external DS in the current study and may be of value in optimizing ventilator treatment.


Assuntos
COVID-19 , Insuficiência Respiratória , Humanos , Adulto , Dióxido de Carbono , Espaço Morto Respiratório/fisiologia , Respiração Artificial , Estudos Prospectivos , COVID-19/terapia , Capnografia/métodos , Volume de Ventilação Pulmonar , Insuficiência Respiratória/terapia
6.
Acta Anaesthesiol Scand ; 67(8): 1045-1053, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37170621

RESUMO

BACKGROUND: The primary aim of the current study was to investigate the ability of respiratory variations in descending aortic flow, measured with two-dimensional echo at the suprasternal notch (ΔVpeak dAo), to predict fluid responsiveness in anesthetized mechanically ventilated children. In addition, variations in peak descending aortic flow measured with apical transthoracic echo (ΔVpeak LVOT) were examined for the same properties. METHODS: Twenty-seven patients under general anesthesia were investigated in this prospective observational study. Cardiac output, ΔVpeak dAo, and ΔVpeak LVOT were measured at stable conditions after anesthesia induction. The measurements were repeated after a 10 mL kg-1 fluid bolus. Patients were classified as responders if stroke volume index increased by >15% after fluid bolus. The ability of each parameter to predict fluid responsiveness was assessed using receiver operating characteristic curves. RESULTS: Twenty-seven patients were analyzed, mean age and weight 43 months and 16 kg, respectively. Twelve responders and 15 non-responders were identified. ΔVpeak dAo was significantly higher in the responder group (14%, 95% confidence interval [CI]: 12%-17%) compared to the non-responder group (11%, 95% CI: 9%-13%) (p = .04) at baseline. Area under the ROC curve for ΔVpeak dAo and ΔVpeak LVOT was 0.73 (95% CI: 0.52-0.89, p = .02) and 0.56 (0.34-0.78, p = .3), respectively. A baseline level of ΔVpeak dAo of >14% predicted fluid responsiveness with a sensitivity of 58% (95% CI: 28%-85%) and specificity of 73% (95% CI: 45%-92%). CONCLUSION: In mechanically ventilated children, ΔVpeak dAo identified fluid responders with moderate diagnostic power in the current study. ΔVpeak LVOT failed to predict fluid responders in the current study.


Assuntos
Hidratação , Respiração Artificial , Humanos , Criança , Respiração Artificial/métodos , Velocidade do Fluxo Sanguíneo , Hidratação/métodos , Anestesia Geral/métodos , Curva ROC , Volume Sistólico , Hemodinâmica
7.
Eur J Anaesthesiol ; 40(3): 208-215, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36546479

RESUMO

BACKGROUND: MRI often requires sedation or anaesthesia to ensure good image quality in paediatric patients. Access to paediatric anaesthesia services is, however, a limiting factor for effective paediatric MRI service, and alternative sedation methods are, therefore, warranted. OBJECTIVE: To investigate the efficacy and safety of an intranasal dexmedetomidine sedation program for paediatric MRI, without immediate presence of anaesthesia personnel. DESIGN: Single institution retrospective observational study. SETTING: Tertiary care paediatric hospital. PATIENTS: Children 0 to 12 years, ASA risk class 1 or 2 with heart rate within age-appropriate limit. INTERVENTION: Radiology personnel administered an initial dose of intranasal dexmedetomidine of 4 µg kg -1 followed by a second dose of 2 µg kg -1 to the patients if needed. Recordings of image quality, critical events, heart rate, pulse oximetry saturation and noninvasive blood pressure before and after dexmedetomidine administration were made. MAIN OUTCOME MEASURES: Changes in haemodynamic and respiratory data before vs. after intranasal dexmedetomidine were analysed for changes, and the incidence of critical events was evaluated as well as rate of successful MRI scans. RESULTS: One thousand and ninety-one MRIs under intranasal dexmedetomidine sedation were included (mean age 34 months, 95% confidence interval (CI), 33 to 36, 599 male individuals). A success rate of 93% (95% CI, 91 to 94%) was found. No major critical events were recorded, total incidence of minor issues was 0.2% (95% CI, 0 to 0.7%). Five children had a heart rate under a preset minimal limit after dexmedetomidine (0.4%; 95% CI, 0.1 to 0.9%). Significant decreases in heart rate and mean arterial pressure, within acceptable limits not requiring intervention, was seen after dexmedetomidine administration. CONCLUSION: Intranasal dexmedetomidine sedation without immediate presence of anaesthesia personnel appears to be well tolerated and associated with minimal interference on MRI image quality. TRIAL REGISTRATION: clinicaltrials.org NCT05163704, retrospectively registered.


Assuntos
Anestesia , Dexmedetomidina , Radiologia , Humanos , Criança , Masculino , Pré-Escolar , Dexmedetomidina/efeitos adversos , Hipnóticos e Sedativos , Imageamento por Ressonância Magnética
8.
Anesth Analg ; 134(3): 644-652, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34304235

RESUMO

BACKGROUND: The objective of this study was to compare esophageal Doppler cardiac output (COEDM) against the reference method effective pulmonary blood flow cardiac output (COEPBF), for agreement of absolute values and ability to detect change in cardiac output (CO) in pediatric surgical patients. Furthermore, the relationship between these 2 methods and noninvasive blood pressure (NIBP) parameters was evaluated. METHODS: Fifteen children American Society of Anesthesiology (ASA) I and II (median age, 8 months; median weight, 9 kg) scheduled for surgery were investigated in this prospective observational cohort study. Baseline COEPBF/COEDM/NIBP measurements were made at positive end-expiratory pressure (PEEP) 3 cm H2O. PEEP was increased to 10 cm H2O and COEPBF/COEDM/NIBP was recorded after 1 and 3 minutes. PEEP was then lowered to 3 cm H2O, and all measurements were repeated after 3 minutes. Finally, 20-µg kg-1 intravenous atropine was given with the intent to increase CO, and all measurements were recorded again after 5 minutes. Paired recordings of COEDM and COEPBF were examined for agreement and trending ability, and all parameters were analyzed for their responses to the hemodynamic challenges. RESULTS: Bias between COEDM and COEPBF (COEDM - COEPBF) was -17 mL kg-1 min-1 (limits of agreement, -67 to +33 mL kg-1 min-1) with a mean percentage error of 32% (95% confidence interval [CI], 25-37) and a concordance rate of 71% (95% CI, 63-80). The hemodynamic interventions caused by PEEP manipulations resulted in significant decrease in COEPBF absolute numbers (155 mL kg-1 min-1 [95% CI, 151-159] to 127 mL kg-1 min-1 [95% CI, 113-141]) and a corresponding relative decrease of 18% (95% CI, 14-22) 3 minutes after application of PEEP 10. No corresponding decreases were detected by COEDM. Mean arterial pressure showed a relative decrease with 5 (95% CI, 2-8) and 6% (95% CI, 2-10) 1 and 3 minutes after the application of PEEP 10, respectively. Systolic arterial pressure showed a relative decrease of 5% (95% CI, 2-10) 3 minutes after application of PEEP 10. None of the recorded parameters responded to atropine administration except for heart rate that showed a 4% relative increase (95% CI, 1-7, P = .02) 5 minutes after atropine. CONCLUSIONS: COEDM was unable to detect the reduction of CO cause by increased PEEP, whereas COEPBF and to a minimal extent NIBP detected these changes in CO. The ability of COEPBF to react to minor reductions in CO, before noticeable changes in NIBP are seen, suggests that COEPBF may be a potentially useful tool for hemodynamic monitoring in mechanically ventilated children.


Assuntos
Anestesia , Capnografia/métodos , Débito Cardíaco , Esôfago/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Adjuvantes Anestésicos/farmacologia , Pressão Arterial/efeitos dos fármacos , Atropina/farmacologia , Pressão Sanguínea , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Respiração com Pressão Positiva , Estudos Prospectivos , Reprodutibilidade dos Testes , Respiração Artificial
9.
Paediatr Anaesth ; 32(2): 255-261, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34758163

RESUMO

Recent studies have identified stable hemodynamics as a contributing factor to improve outcome in pediatric anesthesia. So far, most of the hemodynamic monitoring methods applied in children have been complex to apply and often not satisfactory validated. Standard mainstream carbon dioxide analysis in combination with real-time mathematical analysis of the measured capnography data has enabled the development of dynamic capnography, a non-invasively cardiac output monitoring method that can be applied without user practice or need for calibrations. Capnodynamic cardiac output assessment has been extensively validated against gold standard reference methods, both in experimental and clinical settings. This review will describe the principle behind dynamic capnography measurement of cardiac output and mixed venous oxygen saturation. Additionally, the methods limitations and challenges when applied in children will be delineated.


Assuntos
Capnografia , Respiração , Capnografia/métodos , Dióxido de Carbono , Débito Cardíaco , Criança , Hemodinâmica , Humanos
10.
Paediatr Anaesth ; 32(1): 10-16, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34741785

RESUMO

During recent years, a lot of interest has been focused on blood pressure in the context of pediatric anesthesia, trying to define what is normal in relation to age and what numeric values that should be regarded as hypotension, needing active intervention. However, blood pressure is mainly measured as a proxy for flow, that is, cardiac output. Thus, just focusing on specific blood pressure numbers may not necessarily be very useful or appropriate. The aim of this educational review is to put the issue of intraoperative blood pressure in the context of pediatric anesthesia in further perspective.


Assuntos
Anestesia , Hipotensão , Anestesia Geral , Pressão Sanguínea , Determinação da Pressão Arterial , Débito Cardíaco , Criança , Humanos , Hipotensão/diagnóstico
11.
J Clin Monit Comput ; 36(5): 1315-1324, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-34609659

RESUMO

Mixed venous oxygen saturation (SvO2) is an important variable in anesthesia and intensive care but currently requires pulmonary artery catheterization. Recently, non-invasive determination of SvO2 (Capno-SvO2) using capnodynamics has shown good agreement against CO-oximetry in an animal model of modest hemodynamic changes. The purpose of the current study was to validate Capno-SvO2 against CO-oximetry during major alterations in oxygen delivery. Furthermore, evaluating fiberoptic SvO2 for its response to the same challenges. Eleven mechanically ventilated pigs were exposed to oxygen delivery changes: increased inhaled oxygen concentration, hemorrhage, crystalloid and blood transfusion, preload reduction and dobutamine infusion. Capno-SvO2 and fiberoptic SvO2 recordings were made in parallel with CO-oximetry. Respiratory quotient, needed for capnodynamic SvO2, was measured by analysis of mixed expired gases. Agreement of absolute values between CO-oximetry and Capno-SvO2 and fiberoptic SvO2 respectively, was assessed using Bland-Altman plots. Ability of Capno- SvO2 and fiberoptic SvO2 to detect change compared to CO-oximetry was assessed using concordance analysis. The interventions caused significant hemodynamic variations. Bias between Capno-SvO2 and CO-oximetry was + 3% points (95% limits of agreements - 7 to + 13). Bias between fiberoptic SvO2 and CO-oximetry was + 1% point, (95% limits of agreements - 7 to + 9). Concordance rate for Capno-SvO2 and fiberoptic SvO2 vs. CO-oximetry was 98% and 93%, respectively. Capno-SvO2 generates absolute values close to CO-oximetry. The performance of Capno-SvO2 vs. CO-oximetry was comparable to the performance of fiberoptic SvO2 vs. CO-oximetry. Capno-SvO2 appears to be a promising tool for non-invasive SvO2 monitoring.


Assuntos
Dobutamina , Saturação de Oxigênio , Animais , Soluções Cristaloides , Oximetria , Oxigênio , Suínos
12.
Anesth Analg ; 132(6): 1768-1776, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33009138

RESUMO

BACKGROUND: Mixed venous oxygen saturation (Svo2) is important when evaluating the balance between oxygen delivery and whole-body oxygen consumption. Monitoring Svo2 has so far required blood samples from a pulmonary artery catheter. By combining volumetric capnography, for measurement of effective pulmonary blood flow, with the Fick principle for oxygen consumption, we have developed a continuous noninvasive method, capnodynamic Svo2, for assessment of Svo2. The objective of this study was to validate this new technique against the gold standard cardiac output (CO)-oximetry Svo2 measurement of blood samples obtained from a pulmonary artery catheter and to assess the potential influence of intrapulmonary shunting. METHODS: Eight anesthetized mechanically ventilated domestic-breed piglets of both sexes (median weight 23.9 kg) were exposed to a series of interventions intended to reduce as well as increase Svo2. Simultaneous recordings of capnodynamic and CO-oximetry Svo2 as well as shunt fraction, using the Berggren formula, were performed throughout the protocol. Agreement of absolute values for capnodynamic and CO-oximetry Svo2 and the ability for capnodynamic Svo2 to detect change were assessed using Bland-Altman plot and concordance analysis. RESULTS: Overall bias for capnodynamic versus CO-oximetry Svo2 was -1 percentage point (limits of agreement -13 to +11 percentage points), a mean percentage error of 22%, and a concordance rate of 100%. Shunt fraction varied between 13% at baseline and 22% at the end of the study and was associated with only minor alterations in agreement between the tested methods. CONCLUSIONS: In the current experimental setting, capnodynamic assessment of Svo2 generates absolute values very close to the reference method CO-oximetry and is associated with 100% trending ability.


Assuntos
Débito Cardíaco/fisiologia , Oximetria/métodos , Consumo de Oxigênio/fisiologia , Estudo de Prova de Conceito , Animais , Capnografia/métodos , Feminino , Masculino , Respiração Artificial/métodos , Suínos
13.
Acta Anaesthesiol Scand ; 64(8): 1106-1113, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32314349

RESUMO

BACKGROUND: Capnoperitoneum during laparoscopy leads to cranial shift of the diaphragm, loss in lung volume, and risk of impaired gas exchange. Infants are susceptible to these changes and bedside assessment of lung volume during laparoscopy might assist with optimizing the ventilation. Thus, the primary aim was to investigate the monitoring value of a continuous end-expiratory lung volume (EELV) assessment method based on CO2 dynamics ( EELV CO 2 ) in a pediatric capnoperitoneum model by evaluating the correlation and trending ability against helium washout (EELVHe ). METHODS: Intra-abdominal pressure (IAP) was randomly varied between 0, 6, and 12 mm Hg with CO2 insufflation, while positive end-expiratory pressure (PEEP) levels of 3, 6, and 9 cm H2 O were randomly applied in eight anesthetized and mechanically ventilated chinchilla rabbits. Concomitant EELV CO 2 and EELVHe and lung clearance index (LCI) were obtained under each experimental condition. RESULTS: Significant correlations were found between EELV CO 2 and EELVHe before capnoperitoneum (r = .85, P < .001), although increased IAP distorted this relationship. The negative influence of IAP was counteracted by the application of PEEP 9, which restored the correlation between EELV CO 2 and EELVHe and resulted in 100% concordance rate between the methods regarding changes in lung volume. EELVHe and LCI showed a curvilinear relationship, and an EELVHe of approximately 20 mL kg-1 , determined with a receiver operating characteristic curve, was associated with near-normal LCI values. CONCLUSION: In this animal model of pediatric capnoperitoneum, reliable assessment of changes in EELV based on EELV CO 2 requires an open lung strategy, defined as EELV above approximately 20 mL kg-1 .


Assuntos
Dióxido de Carbono/administração & dosagem , Hélio/administração & dosagem , Insuflação/métodos , Cavidade Peritoneal/fisiopatologia , Pneumoperitônio/fisiopatologia , Respiração com Pressão Positiva/métodos , Animais , Modelos Animais de Doenças , Laparoscopia/métodos , Medidas de Volume Pulmonar , Pediatria , Coelhos
14.
Acta Anaesthesiol Scand ; 64(8): 1114-1119, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32386340

RESUMO

BACKGROUND: Capnoperitoneum provides a ventilatory challenge due to reduction in end-expiratory lung volume and peritoneal carbon dioxide absorption in both children and adults. The primary aim of this controlled interventional trial was to determine the positive end-expiratory pressure (PEEP) level needed to ensure for adequate carbon dioxide clearance and preservation of carbon dioxide homeostasis in an experimental model of infant laparoscopy. The secondary aim was to evaluate potential effects on cardiac output of PEEP and abdominal pressure level variations in the same setting. METHODS: Eight chinchilla bastard rabbits were anesthetized and mechanically ventilated. Intra-abdominal pressures were randomly set to 0, 6, and 12 mm Hg by carbon dioxide insufflation. Carbon dioxide clearance using volumetric capnography, arterial blood gas data, and cardiac output was recorded, while PEEP 3, 6, and 9 cmH2 O were applied in a random order. RESULTS: A PEEP of 9 cmH2 O showed restoration of carbon dioxide clearance without causing changes in arterial partial pressure of carbon dioxide and bicarbonate and with no associated deterioration in cardiac output. CONCLUSION: The results promote a PEEP level of 9 cmH2 O in this model of infant capnoperitoneum to allow for adequate carbon dioxide removal with subsequent preservation of carbon dioxide homeostasis. The use of high PEEP was not associated with any decrease in cardiac output.


Assuntos
Dióxido de Carbono/administração & dosagem , Laparoscopia/métodos , Pneumoperitônio/prevenção & controle , Respiração com Pressão Positiva/métodos , Animais , Modelos Animais de Doenças , Homeostase , Insuflação , Pediatria , Coelhos
15.
16.
Int J Qual Health Care ; 31(7): 30-36, 2019 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-30624735

RESUMO

OBJECTIVE: To explore how the See-and-Treat concept can be applied in primary care and its effect on volume and productivity. DESIGN: An explanatory single-case study design with a mixed methods approach and presented according to the SQUIRE 2.0 guidelines. SETTING: A publicly-funded, private primary care provider within the Stockholm County, which caters to a diverse patient population in terms of ethnicity, religion, socioeconomic status and care needs. PARTICIPANTS: CEO, center manager, four physicians, two licensed practical nurses, one medical secretary and one lab assistant. INTERVENTION: A See-and-Treat unit was established to offer same-day service for acute unplanned visits. Standardized patient symptom forms were created that allowed patients to self-triage and then enter into a streamlined care process consisting of a quick diagnostic lab and a physician visit. MAIN OUTCOME MEASURES: Volume, productivity, staff perceptions and patient satisfaction were measured through data on number and type of contacts per 1000 listed patients, visits per physician, observations, interviews and a questionnaire. RESULTS: A significant decrease in the acute and total number of visits, a continued trend of diminishing telephone contacts, and a non-significant increase in physician productivity. Patients were very satisfied, and staff perceived an improved quality of care. CONCLUSIONS: See-and-Treat appears to be a viable approach for a specific primary care patient segment interested in acute same-day-service. Opening up access and standardizing care made it possible to efficiently address these needs and engage patients.


Assuntos
Atenção Primária à Saúde/métodos , Atenção Primária à Saúde/organização & administração , Triagem/métodos , Eficiência Organizacional , Feminino , Humanos , Masculino , Estudos de Casos Organizacionais , Satisfação do Paciente/estatística & dados numéricos , Médicos de Atenção Primária/estatística & dados numéricos , Inquéritos e Questionários , Suécia , Triagem/estatística & dados numéricos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA