RESUMO
AIMS: The aim of the study is to audit the titanium reconstruction of jaw defects in benign conditions in Christian Medical College and Hospital, Vellore. METHODS AND MATERIAL: A retrospective study of titanium reconstruction of mandibular defects due to jaw lesions at Christian Medical College and Hospital, Vellore, India, between May 2008 and May 2011. RESULTS: Mouth opening, facial symmetry, occlusion, chewing ability, plate exposure and patient satisfaction were used as outcome measures. CONCLUSIONS: The three-dimensional titanium plate is a reasonable material for immediate mandible reconstruction after surgical resection of benign jaw pathologies.