Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Phys Rev Lett ; 130(21): 211001, 2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37295105

RESUMO

We present the observation of a charge-sign dependent solar modulation of galactic cosmic rays (GCRs) with the Calorimetric Electron Telescope onboard the International Space Station over 6 yr, corresponding to the positive polarity of the solar magnetic field. The observed variation of proton count rate is consistent with the neutron monitor count rate, validating our methods for determining the proton count rate. It is observed by the Calorimetric Electron Telescope that both GCR electron and proton count rates at the same average rigidity vary in anticorrelation with the tilt angle of the heliospheric current sheet, while the amplitude of the variation is significantly larger in the electron count rate than in the proton count rate. We show that this observed charge-sign dependence is reproduced by a numerical "drift model" of the GCR transport in the heliosphere. This is a clear signature of the drift effect on the long-term solar modulation observed with a single detector.


Assuntos
Radiação Cósmica , Voo Espacial , Telescópios , Prótons , Elétrons
2.
Phys Rev Lett ; 130(17): 171002, 2023 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-37172251

RESUMO

We present the results of a direct measurement of the cosmic-ray helium spectrum with the CALET instrument in operation on the International Space Station since 2015. The observation period covered by this analysis spans from October 13, 2015, to April 30, 2022 (2392 days). The very wide dynamic range of CALET allowed for the collection of helium data over a large energy interval, from ∼40 GeV to ∼250 TeV, for the first time with a single instrument in low Earth orbit. The measured spectrum shows evidence of a deviation of the flux from a single power law by more than 8σ with a progressive spectral hardening from a few hundred GeV to a few tens of TeV. This result is consistent with the data reported by space instruments including PAMELA, AMS-02, and DAMPE and balloon instruments including CREAM. At higher energy we report the onset of a softening of the helium spectrum around 30 TeV (total kinetic energy). Though affected by large uncertainties in the highest energy bins, the observation of a flux reduction turns out to be consistent with the most recent results of DAMPE. A double broken power law is found to fit simultaneously both spectral features: the hardening (at lower energy) and the softening (at higher energy). A measurement of the proton to helium flux ratio in the energy range from 60 GeV/n to about 60 TeV/n is also presented, using the CALET proton flux recently updated with higher statistics.

4.
Phys Rev Lett ; 131(19): 191001, 2023 Nov 10.
Artigo em Inglês | MEDLINE | ID: mdl-38000434

RESUMO

Detailed measurements of the spectral structure of cosmic-ray electrons and positrons from 10.6 GeV to 7.5 TeV are presented from over 7 years of observations with the CALorimetric Electron Telescope (CALET) on the International Space Station. The instrument, consisting of a charge detector, an imaging calorimeter, and a total absorption calorimeter with a total depth of 30 radiation lengths at normal incidence and a fine shower imaging capability, is optimized to measure the all-electron spectrum well into the TeV region. Because of the excellent energy resolution (a few percent above 10 GeV) and the outstanding e/p separation (10^{5}), CALET provides optimal performance for a detailed search of structures in the energy spectrum. The analysis uses data up to the end of 2022, and the statistics of observed electron candidates has increased more than 3 times since the last publication in 2018. By adopting an updated boosted decision tree analysis, a sufficient proton rejection power up to 7.5 TeV is achieved, with a residual proton contamination less than 10%. The observed energy spectrum becomes gradually harder in the lower energy region from around 30 GeV, consistently with AMS-02, but from 300 to 600 GeV it is considerably softer than the spectra measured by DAMPE and Fermi-LAT. At high energies, the spectrum presents a sharp break around 1 TeV, with a spectral index change from -3.15 to -3.91, and a broken power law fitting the data in the energy range from 30 GeV to 4.8 TeV better than a single power law with 6.9 sigma significance, which is compatible with the DAMPE results. The break is consistent with the expected effects of radiation loss during the propagation from distant sources (except the highest energy bin). We have fitted the spectrum with a model consistent with the positron flux measured by AMS-02 below 1 TeV and interpreted the electron+positron spectrum with possible contributions from pulsars and nearby sources. Above 4.8 TeV, a possible contribution from known nearby supernova remnants, including Vela, is addressed by an event-by-event analysis providing a higher proton-rejection power than a purely statistical analysis.

5.
Phys Rev Lett ; 128(13): 131103, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-35426700

RESUMO

The relative abundance of cosmic ray nickel nuclei with respect to iron is by far larger than for all other transiron elements; therefore it provides a favorable opportunity for a low background measurement of its spectrum. Since nickel, as well as iron, is one of the most stable nuclei, the nickel energy spectrum and its relative abundance with respect to iron provide important information to estimate the abundances at the cosmic ray source and to model the Galactic propagation of heavy nuclei. However, only a few direct measurements of cosmic-ray nickel at energy larger than ∼3 GeV/n are available at present in the literature, and they are affected by strong limitations in both energy reach and statistics. In this Letter, we present a measurement of the differential energy spectrum of nickel in the energy range from 8.8 to 240 GeV/n, carried out with unprecedented precision by the Calorimetric Electron Telescope (CALET) in operation on the International Space Station since 2015. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z=40). The particle's energy is measured by a homogeneous calorimeter (1.2 proton interaction lengths, 27 radiation lengths) preceded by a thin imaging section (3 radiation lengths) providing tracking and energy sampling. This Letter follows our previous measurement of the iron spectrum [1O. Adriani et al. (CALET Collaboration), Phys. Rev. Lett. 126, 241101 (2021).PRLTAO0031-900710.1103/PhysRevLett.126.241101], and it extends our investigation on the energy dependence of the spectral index of heavy elements. It reports the analysis of nickel data collected from November 2015 to May 2021 and a detailed assessment of the systematic uncertainties. In the region from 20 to 240 GeV/n our present data are compatible within the errors with a single power law with spectral index -2.51±0.07.

6.
Phys Rev Lett ; 129(10): 101102, 2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36112450

RESUMO

A precise measurement of the cosmic-ray proton spectrum with the Calorimetric Electron Telescope (CALET) is presented in the energy interval from 50 GeV to 60 TeV, and the observation of a softening of the spectrum above 10 TeV is reported. The analysis is based on the data collected during ∼6.2 years of smooth operations aboard the International Space Station and covers a broader energy range with respect to the previous proton flux measurement by CALET, with an increase of the available statistics by a factor of ∼2.2. Above a few hundred GeV we confirm our previous observation of a progressive spectral hardening with a higher significance (more than 20 sigma). In the multi-TeV region we observe a second spectral feature with a softening around 10 TeV and a spectral index change from -2.6 to -2.9 consistently, within the errors, with the shape of the spectrum reported by DAMPE. We apply a simultaneous fit of the proton differential spectrum which well reproduces the gradual change of the spectral index encompassing the lower energy power-law regime and the two spectral features observed at higher energies.

7.
Phys Rev Lett ; 129(25): 251103, 2022 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-36608255

RESUMO

We present the measurement of the energy dependence of the boron flux in cosmic rays and its ratio to the carbon flux in an energy interval from 8.4 GeV/n to 3.8 TeV/n based on the data collected by the Calorimetric Electron Telescope (CALET) during ∼6.4 yr of operation on the International Space Station. An update of the energy spectrum of carbon is also presented with an increase in statistics over our previous measurement. The observed boron flux shows a spectral hardening at the same transition energy E_{0}∼200 GeV/n of the C spectrum, though B and C fluxes have different energy dependences. The spectral index of the B spectrum is found to be γ=-3.047±0.024 in the interval 25

8.
Phys Rev Lett ; 126(24): 241101, 2021 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-34213922

RESUMO

The Calorimetric Electron Telescope (CALET), in operation on the International Space Station since 2015, collected a large sample of cosmic-ray iron over a wide energy interval. In this Letter a measurement of the iron spectrum is presented in the range of kinetic energy per nucleon from 10 GeV/n to 2.0 TeV/n allowing the inclusion of iron in the list of elements studied with unprecedented precision by space-borne instruments. The measurement is based on observations carried out from January 2016 to May 2020. The CALET instrument can identify individual nuclear species via a measurement of their electric charge with a dynamic range extending far beyond iron (up to atomic number Z=40). The energy is measured by a homogeneous calorimeter with a total equivalent thickness of 1.2 proton interaction lengths preceded by a thin (3 radiation lengths) imaging section providing tracking and energy sampling. The analysis of the data and the detailed assessment of systematic uncertainties are described and results are compared with the findings of previous experiments. The observed differential spectrum is consistent within the errors with previous experiments. In the region from 50 GeV/n to 2 TeV/n our present data are compatible with a single power law with spectral index -2.60±0.03.

9.
Phys Rev Lett ; 125(25): 251102, 2020 Dec 18.
Artigo em Inglês | MEDLINE | ID: mdl-33416351

RESUMO

In this paper, we present the measurement of the energy spectra of carbon and oxygen in cosmic rays based on observations with the Calorimetric Electron Telescope on the International Space Station from October 2015 to October 2019. Analysis, including the detailed assessment of systematic uncertainties, and results are reported. The energy spectra are measured in kinetic energy per nucleon from 10 GeV/n to 2.2 TeV/n with an all-calorimetric instrument with a total thickness corresponding to 1.3 nuclear interaction length. The observed carbon and oxygen fluxes show a spectral index change of ∼0.15 around 200 GeV/n established with a significance >3σ. They have the same energy dependence with a constant C/O flux ratio 0.911±0.006 above 25 GeV/n. The spectral hardening is consistent with that measured by AMS-02, but the absolute normalization of the flux is about 27% lower, though in agreement with observations from previous experiments including the PAMELA spectrometer and the calorimetric balloon-borne experiment CREAM.

10.
Phys Rev Lett ; 122(18): 181102, 2019 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-31144869

RESUMO

In this paper, we present the analysis and results of a direct measurement of the cosmic-ray proton spectrum with the CALET instrument onboard the International Space Station, including the detailed assessment of systematic uncertainties. The observation period used in this analysis is from October 13, 2015 to August 31, 2018 (1054 days). We have achieved the very wide energy range necessary to carry out measurements of the spectrum from 50 GeV to 10 TeV covering, for the first time in space, with a single instrument the whole energy interval previously investigated in most cases in separate subranges by magnetic spectrometers (BESS-TeV, PAMELA, and AMS-02) and calorimetric instruments (ATIC, CREAM, and NUCLEON). The observed spectrum is consistent with AMS-02 but extends to nearly an order of magnitude higher energy, showing a very smooth transition of the power-law spectral index from -2.81±0.03 (50-500 GeV) neglecting solar modulation effects (or -2.87±0.06 including solar modulation effects in the lower energy region) to -2.56±0.04 (1-10 TeV), thereby confirming the existence of spectral hardening and providing evidence of a deviation from a single power law by more than 3σ.

11.
Phys Rev Lett ; 120(26): 261102, 2018 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-30004739

RESUMO

Extended results on the cosmic-ray electron + positron spectrum from 11 GeV to 4.8 TeV are presented based on observations with the Calorimetric Electron Telescope (CALET) on the International Space Station utilizing the data up to November 2017. The analysis uses the full detector acceptance at high energies, approximately doubling the statistics compared to the previous result. CALET is an all-calorimetric instrument with a total thickness of 30 X_{0} at normal incidence and fine imaging capability, designed to achieve large proton rejection and excellent energy resolution well into the TeV energy region. The observed energy spectrum in the region below 1 TeV shows good agreement with Alpha Magnetic Spectrometer (AMS-02) data. In the energy region below ∼300 GeV, CALET's spectral index is found to be consistent with the AMS-02, Fermi Large Area Telescope (Fermi-LAT), and Dark Matter Particle Explorer (DAMPE), while from 300 to 600 GeV the spectrum is significantly softer than the spectra from the latter two experiments. The absolute flux of CALET is consistent with other experiments at around a few tens of GeV. However, it is lower than those of DAMPE and Fermi-LAT with the difference increasing up to several hundred GeV. The observed energy spectrum above ∼1 TeV suggests a flux suppression consistent within the errors with the results of DAMPE, while CALET does not observe any significant evidence for a narrow spectral feature in the energy region around 1.4 TeV. Our measured all-electron flux, including statistical errors and a detailed breakdown of the systematic errors, is tabulated in the Supplemental Material in order to allow more refined spectral analyses based on our data.

12.
Phys Rev Lett ; 119(18): 181101, 2017 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-29219544

RESUMO

First results of a cosmic-ray electron and positron spectrum from 10 GeV to 3 TeV is presented based upon observations with the CALET instrument on the International Space Station starting in October, 2015. Nearly a half million electron and positron events are included in the analysis. CALET is an all-calorimetric instrument with total vertical thickness of 30 X_{0} and a fine imaging capability designed to achieve a large proton rejection and excellent energy resolution well into the TeV energy region. The observed energy spectrum over 30 GeV can be fit with a single power law with a spectral index of -3.152±0.016 (stat+syst). Possible structure observed above 100 GeV requires further investigation with increased statistics and refined data analysis.

13.
Sci Rep ; 8(1): 7975, 2018 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-29773826

RESUMO

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has not been fixed in the paper.

14.
Sci Rep ; 7(1): 7816, 2017 08 10.
Artigo em Inglês | MEDLINE | ID: mdl-28798398

RESUMO

Strong magnetic fields, synchrotron emission, and Compton scattering are omnipresent in compact celestial X-ray sources. Emissions in the X-ray energy band are consequently expected to be linearly polarized. X-ray polarimetry provides a unique diagnostic to study the location and fundamental mechanisms behind emission processes. The polarization of emissions from a bright celestial X-ray source, the Crab, is reported here for the first time in the hard X-ray band (~20-160 keV). The Crab is a complex system consisting of a central pulsar, a diffuse pulsar wind nebula, as well as structures in the inner nebula including a jet and torus. Measurements are made by a purpose-built and calibrated polarimeter, PoGO+. The polarization vector is found to be aligned with the spin axis of the pulsar for a polarization fraction, PF = (20.9 ± 5.0)%. This is higher than that of the optical diffuse nebula, implying a more compact emission site, though not as compact as, e.g., the synchrotron knot. Contrary to measurements at higher energies, no significant temporal evolution of phase-integrated polarisation parameters is observed. The polarization parameters for the pulsar itself are measured for the first time in the X-ray energy band and are consistent with observations at optical wavelengths.

15.
Cancer Gene Ther ; 23(8): 278-83, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27468808

RESUMO

Reduced expression in immortalized cells (REIC)/dickkopf-3 (Dkk-3), a tumor suppressor gene, is downregulated in various cancers. We previously reported the tumor-inhibitory effects of the REIC/Dkk-3 gene, delivered by a conventional adenoviral vector (Ad-CAG-REIC) in pancreatic cancer. Here, we developed an Ad-REIC vector with a novel gene expression system, termed the super gene expression (SGE) system, and assessed its therapeutic effects relative to those of Ad-CAG-REIC in pancreatic cancer cells. Human pancreatic cancer cell lines ASPC1 and MIAPaCa2 were used. REIC/Dkk-3 expression was assessed by western blot analysis. Relative cell viability and apoptotic effects were examined in vitro. The anti-tumor effects of Ad-REIC treatment were assessed in the mouse xenograft model. Compared with Ad-CAG-REIC, Ad-SGE-REIC elicited a significant increase in REIC protein expression in the cells studied. Relative to Ad-CAG-REIC, Ad-SGE-REIC reduced cell viability and induced apoptosis in the ASPC1 and MIAPaCa2 cell lines in vitro, and achieved superior tumor growth inhibition in the mouse xenograft model. Compared with conventional Ad-REIC agents, Ad-SGE-REIC provided enhanced inhibitory effects against tumor growth. Our results indicate that Ad-SGE-REIC is an innovative therapeutic tool for pancreatic cancer.


Assuntos
Adenoviridae/genética , Terapia Genética , Vetores Genéticos/genética , Peptídeos e Proteínas de Sinalização Intercelular/genética , Neoplasias Pancreáticas/genética , Proteínas Adaptadoras de Transdução de Sinal , Animais , Apoptose/genética , Linhagem Celular Tumoral , Sobrevivência Celular/genética , Quimiocinas , Modelos Animais de Doenças , Expressão Gênica , Ordem dos Genes , Vetores Genéticos/administração & dosagem , Humanos , Peptídeos e Proteínas de Sinalização Intercelular/metabolismo , Proteínas Quinases JNK Ativadas por Mitógeno/metabolismo , Camundongos , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/patologia , Neoplasias Pancreáticas/terapia , Transdução de Sinais , Carga Tumoral/genética , Ensaios Antitumorais Modelo de Xenoenxerto
16.
J Mol Biol ; 221(3): 737-43, 1991 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-1719209

RESUMO

Ribosome-inactivating proteins (RIPs) are known to inactivate eukaryotic ribosomes, which results in the inhibition of protein synthesis, but there has been no evidence that they inactivate the ribosomes of Escherichia coli. Recently, Mirabilis antiviral protein (MAP), a RIP, has been shown to inhibit the protein synthesis of E. coli as well as eukaryotes. To elucidate its mechanism, E. coli ribosomes treated with MAP were analyzed by polyacrylamide/agarose composite gel electrophoresis and RNA sequencing using reverse transcriptase with DNA primer. The 23 S rRNAs, with an A260 value for ribosomes of 15, were completely cleaved in vitro by a 30 minute treatment with MAP at a concentration of 100 nM at 37 degrees C and a subsequent treatment with aniline. However, they were not affected by ricin A-chain under the same conditions. The primer extension of DNA polymerization stopped before A2660 of 23 S rRNA in RNA sequencing. Furthermore, both 16 S and 23 S rRNAs were cleaved by the MAP and aniline treatments when naked E. coli rRNAs were used as substrates, and the primer extension stopped before bases A2660 and A1014, respectively, in RNA sequencing. As the A2660 region has been shown to interact with the elongation factors EF-Tu and EF-G these results indicate that MAP cleaves the N-glycosidic bond at A2660 in E. coli 23 S RNA resulting in the inactivation of the ribosome.


Assuntos
Escherichia coli/efeitos dos fármacos , N-Glicosil Hidrolases , Proteínas de Plantas/farmacologia , Inibidores da Síntese de Proteínas/farmacologia , RNA Ribossômico 23S/efeitos dos fármacos , Ribossomos/efeitos dos fármacos , Sequência de Bases , DNA Bacteriano , Eletroforese em Gel de Poliacrilamida , Escherichia coli/metabolismo , Glicosídeos/química , Glicosídeos/metabolismo , Dados de Sequência Molecular , Conformação de Ácido Nucleico , Proteínas de Plantas/metabolismo , Inibidores da Síntese de Proteínas/metabolismo , RNA Bacteriano , RNA Ribossômico 23S/metabolismo , Proteínas Inativadoras de Ribossomos Tipo 1 , Ribossomos/metabolismo
17.
J Mol Biol ; 226(1): 281-3, 1992 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-1619659

RESUMO

Mirabilis antiviral protein is a single-chain ribosome-inactivating protein purified from the tuberous root of Mirabilis jalapa L. We obtained several forms of crystals of the protein by the hanging drop vapor diffusion method, but most of these crystals were not suitable for X-ray crystallography. After refining the growth conditions, crystals of crystallographic quality were grown in 20-microliters droplets of an equi-volume mixture of 1.5% (w/v) protein solution and a reservoir solution containing 49 to 50% (w/v) ammonium sulfate and 50 mM-ammonium citrate (pH 5.4) at room temperature. Addition of 2 mM-adenine sulfate reduced twinning and "crystal shower". The resulting trigonal crystals diffract beyond 2.5 A resolution using a rotating anode X-ray generator. The space group was determined to be P3(1)21 or P3(2)21 (a = b = 103.9.A, c = 134.6 A, alpha = beta = 90 degrees, gamma = 120 degrees) based on their precession photography of h0l and hk0 zones. There seems to be three monomers in an asymmetric unit for VM = 2.51 A3/Da.


Assuntos
Antivirais/química , N-Glicosil Hidrolases , Proteínas de Plantas/química , Plantas/química , Cristalização , Substâncias Macromoleculares , Proteínas Inativadoras de Ribossomos Tipo 1 , Difração de Raios X
18.
FEBS Lett ; 320(1): 31-4, 1993 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-8462671

RESUMO

Two expression vectors were constructed to produce a putative mature alpha-pokeweed antiviral protein (alpha-PAP) in Escherichia coli with its NH2- and COOH-terminal extrapeptides excised. One was for its intracellular expression with a methionine at its NH2-terminal. The other was for its secretion using an ompA signal peptide. The former product was purified from the total soluble proteins of the transformant with a yield of 1.74 mg/liter and the latter had a yield of 5.55 mg/liter. Both products exhibited RNA N-glycosidase activity on wheat ribosomes and inhibitory activity to protein synthesis in a rabbit reticulocyte system.


Assuntos
Antivirais , Proteínas de Plantas/genética , Sequência de Aminoácidos , Antivirais/química , Antivirais/metabolismo , Sequência de Bases , Cromatografia em Gel , Clonagem Molecular , DNA de Cadeia Simples , Eletroforese em Gel de Poliacrilamida , Escherichia coli , Dados de Sequência Molecular , N-Glicosil Hidrolases/metabolismo , Proteínas de Plantas/química , Proteínas de Plantas/metabolismo , Proteínas Inativadoras de Ribossomos , Proteínas Inativadoras de Ribossomos Tipo 1
19.
Steroids ; 57(1): 32-6, 1992 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-1585391

RESUMO

A rapid, convenient, and specific radioimmunoassay for 5 beta-cholestane-3 alpha,7 alpha,12 alpha,25-tetrol has been developed. Specific antiserum was obtained from rabbits immunized by the bile alcohol-bovine serum albumin conjugate, which was coupled by an (O-carboxymethyl)oxime bridge at the C-3 position. The assay produces values for serum concentrations of bile alcohol glucuronides in patients with cerebrotendinous xanthomatosis.


Assuntos
Encefalopatias/sangue , Colestanóis/sangue , Doenças Musculares/sangue , Radioimunoensaio , Tendões , Xantomatose/sangue , Humanos , Radioisótopos do Iodo
20.
J Vet Med Sci ; 53(6): 981-7, 1991 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-1665085

RESUMO

Pseudorabies virus hemagglutinin was readily adsorbed on mouse erythrocytes at 4, 22, or 37 degrees C, but not on cattle erythrocytes. The adsorbed hemagglutinin could not be eluted from the cells by resuspending in phosphate-buffered saline (PBS), by incubating at 37 or 50 degrees C, or by incubating in the presence of neuraminidase. The receptor on mouse erythrocytes for the hemagglutinin was inactivated by trypsin, but not by neuraminidase, sodium deoxycholate (DOC), potassium periodate (KIO4), dithiothreitol (DTT), 2-mercaptoethanol (2-ME) and formalin. The hemagglutinin was inactivated by trypsin, alpha-amylase, pepsin, DOC, KIO4, and ethylendiamine-tetraacetic acid (EDTA), but not by papain, beta-glucosidase, phospholipase C, neuraminidase, DTT, 2-ME, Tween-80, ethylether, chloroform, trichloro-trifluoroethane, beta-propiolactone and formalin, suggesting that the hemagglutinin active component involved glycoproteins. The hemagglutinin was stable at 37 degrees C for lower temperatures but not at 60 degrees C or higher. The hemagglutinin activity was resistant to ultraviolet irradiation, while the infectivity was very susceptible. The hemagglutinin and the infectivity were readily sedimented by ultracentrifugation at 48,000 x g for 3 hr. In rate zonal centrifugation of the preparation on a sucrose density gradient, the hemagglutination (HA) activity showed a sharp peak at 1.22 g/ml coinciding with the peak of infectivity. The HA activity in the peak fraction seemed to be structually associated with virus particles. After fractionation of the virus by Nonidet P-40, the HA activity was found only in the fraction of the envelope material, indicating that the hemagglutinin is situated in the viral envelop.


Assuntos
Eritrócitos/metabolismo , Hemaglutininas Virais/química , Herpesvirus Suídeo 1 , Adsorção , Animais , Linhagem Celular , Centrifugação com Gradiente de Concentração , Eritrócitos/efeitos dos fármacos , Hemaglutininas Virais/efeitos dos fármacos , Hemaglutininas Virais/efeitos da radiação , Temperatura , Ultracentrifugação , Raios Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA