Artigo em Inglês | MEDLINE | ID: mdl-38845191

RESUMO

INTRODUCTION: Transvenous lead extractions (TLEs) for cardiac implantable electronic device complications often encounter difficulties with strong adhesions to the myocardium or vessels. In this report, we introduce a novel "Four-Stage Rocket" technique for effective TLE in cases where conventional methods fail. METHODS AND RESULTS: Two challenging cases where conventional TLE methods failed were treated using a combination of four devices: Needle's Eye Snare, Agilis NxT Steerable Introducer, GlideLight Laser sheath, and GORE® DrySeal Flex Introducer sheath, employed via the inferior vena cava. The "Four-Stage Rocket" technique successfully detached firmly adhered leads near the tricuspid valve annulus, where the traditional superior vena cava approach was inadequate. CONCLUSION: The "Four-Stage Rocket" technique offers a potential alternative in complex TLE cases, aligning the laser direction with the adhesion detachment and reducing the tissue damage risk.

2.
J Cardiovasc Electrophysiol ; 34(9): 2002-2005, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37526239

RESUMO

BACKGROUND: A 70-year-old man revealed a rare type of atrioventricular nodal re-entrant tachycardia (AVNRT) involving distinct retrograde pathways, superior slow pathway, and inferolateral left atrial slow pathway. RESULT: Radiofrequency ablation was successfully performed on the noncoronary cusp and in the left atrium, respectively, to eliminate the tachycardias. DISCUSSION AND CONCLUSION: Due to the anomalous electrical conduction patterns, careful diagnosis and ablation strategies were necessary to avoid the risk of atrioventricular block. These findings underscore the diversity and complexity of AVNRT and highlight the importance of tailored therapeutic approaches.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular , Masculino , Humanos , Idoso , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Fibrilação Atrial/cirurgia , Eletrocardiografia , Fascículo Atrioventricular , Átrios do Coração
3.
J Cardiovasc Electrophysiol ; 34(1): 71-81, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378816

RESUMO

INTRODUCTION: Local impedance (LI) parameters of IntellaNav STABLEPOINT for successful pulmonary vein isolation (PVI) of atrial fibrillation (AF) remain unclear. The purpose of this study was to seek LI data achieving successful PVI. METHODS: Consecutive AF patients who underwent catheter ablation with STABLEPOINT were prospectively enrolled in two centers. PVI was performed under a constant 35-or 40-watt power, 20-s duration, and >5-g contact force. The operators were blinded to the LI data. The characteristics of all ablation points with/without conduction gaps (Unsuccess or Success tags) after the first-attempt PVI were evaluated for the right/left PVs and anterior/posterior wall (RPV/LPV and AW/PW, respectively), and cutoff values of LI data were calculated for successful lesion formation. RESULTS: A total of 5257 ablation points in 102 patients (65 [58-72] years old, 65.7% male) were evaluated. The LI drop values were higher in the Success tags than Unsuccess tags on the LPV-AW and RPV-AW/PW (p < .001), except for the LPV-PW (p = .105). The %LI drop values (LI drop/initial LI) were higher for the Success tags in all areas (15.8 [12.2%-19.6%] vs. 11.6 [9.7%-15.6%] in LPV-AW: p < .001, 15.0 [11.5%-19.3%] vs. 11.4 [8.7%-17.3%] in LPV-PW: p = .035, 15.3 [11.5%-19.4%] vs. 9.9 [8.1%-13.7%] in RPV-AW: p < .001, and 13.3 [10.1%-17.4%] vs. 8.1 [6.3%-9.5%] in RPV-PW, p < .001). The LI drop and %LI drop cutoff values were 20.0 ohms and 11.6%, respectively. CONCLUSIONS: An insufficient LI drop with STABLEPOINT was associated with a gap formation during PVI, and the best cutoff values for the LI drop and %LI drop were 20.0 ohms and 11.6%, respectively.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Impedância Elétrica , Resultado do Tratamento , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Recidiva
4.
Artigo em Inglês | MEDLINE | ID: mdl-37561371

RESUMO

The subclavian vein is typically used in cardiovascular implantable electronic device (CIED) implantations. External stress on the subclavian vein can lead to lead-related complications. There are several causes of this stress, such as frequent upper extremity movements or external injury. Venous thoracic outlet syndrome (TOS) can also become the cause of external lead stress. However, the diagnosis of venous TOS can be challenging because subclavian venography can appear normal at first glance. We present a unique case of a device infection in a patient with venous TOS. A careful observation of the imaging studies is vital for diagnosing venous TOS and a leadless pacemaker implantation could be an alternative therapeutic option.

5.
Heart Vessels ; 38(2): 216-227, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36173447

RESUMO

Sub-optimal atrioventricular delay (AVD) is one of the main causes of non-responder for cardiac resynchronization therapy (CRT). Recently, device-based algorithms (DBAs) that provide optimal AVD based on intracardiac electrograms, have been developed. However, their long-term effectiveness is still unknown. This study aims to investigate the effect of optimizing AVD using DBAs over a long period, on the prognosis of patients undergoing CRT. A total of 118 patients who underwent CRT at our hospital between April 2008 and March 2018, were retrospectively reviewed; 61 of them with optimizing AVD using DBAs were classified into the treated group (group 1), and the remaining 57 were classified into the control group (group 2). The median follow-up period was 46.0 months. The responder and survival rate in group 1 were significantly better than those in group 2 (group 1 vs. group 2: responder rate = 64% vs. 46%, p = 0.046; survival rate: 85.2% vs. 64.9%, p = 0.02). Moreover, investigating only the non-responder population showed that group 1 had an improved survival rate compared to group 2 (group 1 vs. group 2 = 72.7% vs. 45.1%, p = 0.02). Optimizing AVD using DBAs was a significant contributor to the improved survival rate in CRT non-responders in multivariate analysis (HR 3.6, p = 0.01). In conclusion, the long-term optimizing AVD using DBAs improved the survival rate in CRT and the prognosis of CRT non-responders, as well.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Estudos Retrospectivos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Prognóstico , Algoritmos , Resultado do Tratamento
6.
J Cardiovasc Electrophysiol ; 33(6): 1336-1340, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35347781

RESUMO

INTRODUCTION: Whether diagnostic computed tomography (CT) scans to cardiac implantable electronic devices (CIED) is safe in recent models remains unknown. METHODS: A two-centers observational study. Over 14 years, consecutive 2362 chest CT scans (1666 pacemakers [PMs], 145 cardiac resynchronization therapy PM, 316 implantable cardioverter-defibrillator, and 233 cardiac resynchronization therapy defibrillator) were interrogated and monitored upon imaging. RESULTS: Electromagnetic interference occurred only in a few old models: InSync 8040 (n = 14), InSync III Marquis (n = 1), and Kappa (n = 4), which resulted no adverse events. CONCLUSION: CIEDs, especially recent ones, are confirmed safe on chest CT.


Assuntos
Terapia de Ressincronização Cardíaca , Desfibriladores Implantáveis , Marca-Passo Artificial , Computadores , Desfibriladores Implantáveis/efeitos adversos , Humanos , Marca-Passo Artificial/efeitos adversos , Tomografia
7.
Circ J ; 87(1): 50-62, 2022 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-35989303

RESUMO

BACKGROUND: Optimal periprocedural oral anticoagulant (OAC) therapy before catheter ablation (CA) for atrial fibrillation (AF) and the safety profile of OAC discontinuation during the remote period (from 31 days and up to 1 year after CA) have not been well defined.Methods and Results: The RYOUMA registry is a prospective multicenter observational study of Japanese patients who underwent CA for AF in 2017-2018. Of the 3,072 patients, 82.3% received minimally interrupted direct-acting OACs (DOACs) and 10.2% received uninterrupted DOACs. Both uninterrupted and minimally interrupted DOACs were associated with an extremely low thromboembolic event rate. Female, long-standing persistent AF, low creatinine clearance, hepatic disorder, and high intraprocedural heparin dose were independent factors associated with periprocedural major bleeding. At 1 year after CA, DOAC was continued in 55.9% of patients and warfarin in 56.4%. The incidence of thromboembolic and major bleeding events for 1 year was 0.3% and 1.2%, respectively. Age ≥73 years, dementia, and AF recurrence were independently associated with major bleeding events. Univariate analyses revealed that warfarin continuation and off-label overdose of DOACs were risk factors for major bleeding after CA. CONCLUSIONS: High intraprocedural dose of heparin was associated with periprocedural major bleeding events. At 1 year after CA, over half of the patients had continued OAC therapy. Thromboembolic events were extremely low; however, major bleeding occurred in 1.2%. Age ≥73 years, dementia, and AF recurrence were independently associated with major bleeding after CA.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Demência , Tromboembolia , Humanos , Feminino , Idoso , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Varfarina/uso terapêutico , Japão/epidemiologia , Estudos Prospectivos , Resultado do Tratamento , Anticoagulantes/uso terapêutico , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Tromboembolia/epidemiologia , Tromboembolia/etiologia , Tromboembolia/prevenção & controle , Heparina/efeitos adversos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Demência/cirurgia , Administração Oral
8.
Pacing Clin Electrophysiol ; 45(12): 1390-1400, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36222300

RESUMO

BACKGROUND: A novel irrigation catheter (QDOT MICRO™) has been introduced, which enables a surface temperature-controlled ablation combined with tip cooling. However, the detailed description of its complex behavior and effect on the incidence of pops and lesion formation remains elusive. This study aimed to systematically investigate the ablation characteristics, feedback behavior, and incidence of steam pops in a simplified ex vivo swine model. METHODS: Using swine ventricular tissue perfused with saline at 37°C, we systematically created lesions with 4×3 combinations of the wattage (20, 30, 40, and 50 W) and contact force (CF, 10, 30, and 50 g). Ablation was continued for either 120 s or until a steam pop occurred and repeated 10 times with each setting. The lesion geometry, ablation index, feedback dynamics, and conditions underlying the steam pops were measured and analyzed. RESULTS: Steam pops occurred particularly frequently in combinations of a low CF and high power (10 g vs. 30 g+50 g [p < .0001]; 40 W+50 W vs. 20 W+30 W [p < .0001]). Failure to activate a feedback process was associated with a 5.1 times higher incidence of steam pops (21/109 vs.11/11, [95% CI 3.499-7.716], p < .0001). The wattage feedback was particularly evident with a high CF (30 and 50 g) and high initial wattage (40 and 50 W). The average delivered wattage at 27 W predicted the occurrence of steam pops. CONCLUSION: The temperature-controlled ablation with the QDOT MICRO™ demonstrated a complex feedback behavior, which contributed to a reduced incidence of steam pops and prolonged lead time to the pops.


Assuntos
Modelos Teóricos , Vapor , Animais , Suínos
9.
Int Heart J ; 63(5): 953-956, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36184554

RESUMO

The Senning operation used to be widely performed for an intracardiac repair in a complete transposition of the great arteries. During the long-term follow-up, supraventricular tachycardia (SVT) is often observed because of the complex suture lines. The typical mechanism of a Senning-related SVT is cavo-tricuspid isthmus-dependent atrial flutter. On rare occasions, complex SVTs (e.g., biatrial tachycardia (BiAT)) whose diagnosis and treatment are challenging, may occur. We report a rare case of a BiAT following a Senning operation that was successfully ablated from the superior vena cava, and the local activation time histogram module (CARTO3 V7 module [Biosense Webster, Irvine, CA, USA]) was crucial for analyzing the complex circuit.


Assuntos
Transposição das Grandes Artérias , Ablação por Cateter , Situs Inversus , Taquicardia Supraventricular , Transposição dos Grandes Vasos , Transposição das Grandes Artérias/efeitos adversos , Artérias , Ablação por Cateter/efeitos adversos , Humanos , Situs Inversus/complicações , Taquicardia , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/cirurgia , Transposição dos Grandes Vasos/complicações , Transposição dos Grandes Vasos/cirurgia , Veia Cava Superior/cirurgia
10.
J Cardiovasc Electrophysiol ; 32(12): 3187-3194, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34559441

RESUMO

BACKGROUND: Local impedance (LI) has emerged as a new technology that informs on electrical catheter-tissue coupling during radiofrequency (RF) ablation. Recently, IntellaNav StablePoint, a novel LI-enabled catheter that equips contact force (CF) sensing, has been introduced. Although StablePoint and its predecessor IntellaNav MiFi OI share the common technology that reports LI, distinct mechanics for LI sensing between the two products raise a concern that the LI-RF lesion formation relationship may differ. METHODS: In an ex vivo swine cardiac tissue model, we investigated the initial level and range of a reduction in LI during a 60-s RF ablation and the resultant lesion characteristics at nine combinations of three energy power (30, 40, and 50 W) and CF (10, 30, and 50 g) steps. Correlations and interactions between CF, LI, wattage, and formed lesions were analyzed. Incidence of achieving LI drop plateau and that of a steam pop were also determined. RESULTS: Positive correlations existed between CF and initial LI, CF and absolute/relative LI drop, CF and lesion volume, and LI drop and lesion volume. At the same LI drop, wattage-dependent gain in lesion volume was observed. Steam pops occurred in all CF steps and the prevalence was highest at 50 W. LI drop predicted a steam pop with a cutoff value at 89Ω. CONCLUSION: In StablePoint, wattage crucially affects LI drop and lesion volume. Because 30 W ablation may by underpowered for intramural lesion formation and 50 W often resulted in a steam pop, 40 W appears to achieve the balance between the safety and efficacy.


Assuntos
Ablação por Cateter , Animais , Ablação por Cateter/métodos , Catéteres , Impedância Elétrica , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Ventrículos do Coração/cirurgia , Vapor , Suínos
11.
J Cardiovasc Electrophysiol ; 32(8): 2069-2076, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34185348

RESUMO

BACKGROUND: The local impedance (LI) reflects the electrical catheter-tissue coupling and correlates with the local tissue temperature. However, there have been few clinical studies showing the recommended method for LI monitoring catheters. This study aimed to investigate the optimal ablation setting for this catheter in an in vitro experimental model. METHODS: LI monitoring catheters were used in an excised swine heart experimental model. The tissue contact force (CF) was directly monitored from an external weight scale. Radiofrequency ablation was performed with a combination of various energy power settings (30, 40, and 50 W), and various CFs (10, 30, and 50 g) for 60 s. The correlation between the LI-related indexes, power, and CF with the lesion formation was statistically analyzed. RESULTS: A positive correlation between the LI or lesion formation and CF was observed under all powers. Although the LI drop always correlated with the maximum lesion depth, lesion diameter, and lesion volume, the coefficient of the correlation value was lower under a high CF (lesion depth, diameter, and volume; 10 g, r = 0.8064, r = 0.8389, r = 0.8477; 30 g, r = 0.7590, r = 0.8063, r = 0.8060; 50 g r = 0.5555, r = 0.5701, and r = 0.5678, respectively). Steam pops occurred only under a 50 W ablation and the LI drop cutoff value for steam pops was 46 Ω. CONCLUSION: The same LI drop did not always lead to the same lesion size when the CF differed. Monitoring the LI and not exceeding 46 Ω would be useful for a safe ablation.


Assuntos
Ablação por Cateter , Animais , Catéteres , Impedância Elétrica , Modelos Teóricos , Vapor , Suínos
12.
J Cardiovasc Electrophysiol ; 32(7): 1877-1883, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33955099

RESUMO

INTRODUCTION: Detailed three-dimensional (3D) mapping has been useful for effective radiofrequency catheter ablation. The Rhythmia system can create atrio-ventricular dual-chamber mapping, which reveals the atrial and ventricular potentials all at once in the same map. The aim of this study was to investigate the utility of mapping the atrium and ventricle simultaneously with a high-density 3D mapping system for the ablation of accessory pathways (AP). METHODS: From July 2015 to August 2020, 111 patients underwent ablation of APs. Dual-chamber maps were created in 50 patients (median age 15 [10-54], 32 male [64.0%]), while 61 patients underwent radiofrequency (RF) ablation with conventional single-chamber 3D maps. The background characteristics and procedural details were compared between the dual-chamber mapping group and the conventional single-chamber mapping group. RESULTS: The number of RF applications (median [IQR]; 1.0 [1.0-3.0] vs. 3.0 [1.0-6.0], p = .0023), RF time (median [IQR], s; 9.2 [2.0-95.7] vs. 95.6 [4.1-248.7], p = .0107), and RF energy (median [IQR], J; 248.4 [58.7-3328.2] vs. 2867.6 [134.2-7728.4], p = .0115) were significantly lower in the dual-chamber group. The fluoroscopy time (median [IQR], min; 19.9 [14.2-26.1] vs. 26.5 [17.7-43.4], p = .0025) and fluoroscopy dose (median [IQR], mGy; 52.5 [31.3-146.0] vs. 119.0 [43.7-213.5], p = .0249) were also significantly lower in the dual-chamber than single-chamber mapping group. CONCLUSION: The dual-chamber mapping was useful for ablating accessory pathways and reducing the number of RF applications, total RF energy, and radiation exposure as compared with traditional mapping techniques.


Assuntos
Feixe Acessório Atrioventricular , Ablação por Cateter , Exposição à Radiação , Feixe Acessório Atrioventricular/diagnóstico por imagem , Feixe Acessório Atrioventricular/cirurgia , Adolescente , Fluoroscopia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Humanos , Masculino
13.
Pacing Clin Electrophysiol ; 44(3): 481-489, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33393087

RESUMO

BACKGROUND: After the reports of recalled leads, several technological improvements have been introduced and the durability of implantable cardioverter defibrillator (ICD) leads has improved. The incidence of lead failures is now less than in the previous studies. However, there are few reports that have shown the long-term durability of ICD leads as compared to pacemaker (PM) leads. This study analyzed the medium to long-term performance of transvenous ICD leads as compared to PM leads. METHODS: We retrospectively studied 1227 cases from April 2007 to December 2017 who underwent an initial transvenous ICD or PM implantation. The number of lead failures and patient background characteristics were analyzed. RESULTS: During a median 3-3.5 years follow up period, 1 (0.3%) ICD lead and 18 (2.4%) PM leads failed. The incidence of lead failures was significantly higher in the PM group than ICD group (p = .019). Males were associated with a higher incidence of lead failures in the PM group. CONCLUSION: Since the era of recalled ICD leads, the durability of ICD leads has remarkably improved and the incidence of lead failures with non-recalled ICD leads has been less than that for PM leads.


Assuntos
Desfibriladores Implantáveis , Eletrodos Implantados , Marca-Passo Artificial , Idoso , Remoção de Dispositivo , Análise de Falha de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores Sexuais
14.
Acta Med Okayama ; 75(6): 691-697, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34955536

RESUMO

Although diagnostic and therapeutic strategies for acute stroke patients in Japan depend largely on magnetic resonance imaging (MRI), patients with cardiac implantable electronic devices (CIED) must still rely on com-puted tomography (CT). We retrospectively analyzed clinical and neuroimaging data of ischemic stroke patients with CIED treated at our hospital. Forty-five patients were enrolled in the study. Patients were divided into two groups according to whether corresponding lesions were detected (group A, n = 21) or not detected (group B, n = 24) by the first brain CT. We also evaluated in detail the clinical courses of patients who arrived at hospital within therapeutic time windows for recanalization therapy. Negative fresh infarct in the first CT was associated, though not significantly, with early onset-to-arrival time and subcortical white matter infarction. Five patients did not undergo recanalization therapy because their families did not agree to the procedure. The reasons for their lack of consent included inadequate information about the safety and efficacy of recanalization therapy because MRI could not be performed. Our study confirmed delayed detection of the corresponding lesion and undertreatment for acute stroke in patients with CIED.


Assuntos
Marca-Passo Artificial/efeitos adversos , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Japão , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
15.
Int Heart J ; 61(4): 859, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32728005

RESUMO

The errors in the following list appeared in the article entitled "Differential Atrial Pacing to Detect Reconnection Gaps After Pulmonary Vein Isolation in Atrial Fibrillation" by Mai Tahara, Ritsushi Kato, Yoshifumi Ikeda, Koji Goto, So Asano, Hitoshi Mori, Shiro Iwanaga, Toshihiro Muramatsu, and Kazuo Matsumoto (Vol. 61, No. 3, 503-509, 2020).

16.
Int Heart J ; 61(3): 503-509, 2020 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-32418967

RESUMO

High-resolution mapping is useful to identify reconnection gaps in the pulmonary vein after pulmonary vein isolation for atrial fibrillation. However, it is sometimes difficult to differentiate pulmonary vein potentials from far-field potentials because of very low amplitudes. Our purpose was to evaluate the usefulness of a novel differential atrial pacing method to differentiate reconnected pulmonary vein potentials from isolated pulmonary vein potentials. This retrospective observational study included 34 patients with atrial fibrillation (22 men; mean age, 64 ± 14 years; 28 with paroxysmal atrial fibrillation) who underwent radiofrequency or cryoballoon ablation. Following pulmonary vein isolation, we created a high-resolution activation map during pacing from both the coronary sinus and left atrial appendage. We compared the characteristics of the pulmonary vein potentials and the pattern of activation between the reconnected and isolated pulmonary veins. We analyzed 131 pulmonary veins and found reconnections in 41 pulmonary veins (R group); 90 pulmonary veins had no reconnection (NR group). The R group had a significantly shorter distance between the earliest pulmonary vein activation sites in both activation maps, compared with the NR group (5.22 ± 0.53 mm versus 17.08 ± 0.36 mm, respectively; P < 0.0001). The amplitude of the pulmonary vein potentials was higher in the R group versus the NR group (0.61 ± 0.05 mV versus 0.04 ± 0.03 mV, respectively; P < 0.0001). Six gaps (14%) in the R group that were unrecognized using a conventional method were identified using our novel method. In conclusion, differential atrial pacing was useful to identify pulmonary vein reconnection gaps during ablation using a novel high-resolution mapping system.


Assuntos
Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial/métodos , Ablação por Cateter , Sistema de Condução Cardíaco , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares , Estudos Retrospectivos
17.
Int Heart J ; 61(5): 913-921, 2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-32921668

RESUMO

Previous study has identified marked differences in patient characteristics and causes of inappropriate shock (IAS) between Japan and the Western societies in terms of subcutaneous implantable cardioverter-defibrillator (S-ICD). However, evidence of IAS in Asian populations including Japan has been limited to one observational study.Thus, we conducted a single-center registry study that tracks the postoperative course of 61 consecutive patients who received S-ICD from February 2016 to January 2020. Our findings showed that IAS occurred in 9.8% of the study population (6/61), which is comparable to the previously reported incidence. Remarkably, T-wave oversensing did not result in an IAS (0/6). Instead, myopotential oversensing was determined to have caused the most IAS events (4/6), while atrial fibrillation ranked second (2/6). A provocation maneuver (e.g., abdominal clench, push-ups, lifting a heavy item) reproduced myopotential noise disguised as R-waves, which should potentially trigger an IAS if uninterrupted. R-wave amplitude of the IAS group appeared relatively low compared to that of the non-IAS group although this finding was not tested significant. Furthermore, no temporal changes were noted in R-wave amplitude between the time of implantation and IAS events, suggesting that it is neither constantly low nor acutely dropped R-wave amplitude but a relatively high noise level that drives IAS. All the myopotential-IAS patients were found to be male. Right-sided lead implantation was associated with a higher incidence of IAS.This study highlights the fact that IAS continues to occur due to myopotential noise oversensing instead of T-wave oversensing. To minimize the risk of IAS, it is desirable to search and secure high R-wave voltage.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/estatística & dados numéricos , Músculo Esquelético/fisiologia , Taquicardia Ventricular/diagnóstico , Fibrilação Ventricular/diagnóstico , Adolescente , Adulto , Idoso , Criança , Erros de Diagnóstico , Falha de Equipamento , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Taquicardia Ventricular/terapia , Fibrilação Ventricular/terapia , Adulto Jovem
18.
Int Heart J ; 61(1): 54-59, 2020 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-31956147

RESUMO

Right ventricular (RV) lead perforations are relatively rare but a potentially life-threatening complication of surgical implantations of cardiac implantable electronic devices (CIEDs). The result of percutaneous simple lead traction after lead perforations in the Japanese population has not been well clarified.We retrospectively studied 1359 patients (pacemakers [PMs], 973 patients; implantable cardioverter defibrillators [ICD], 386 patients) from April 2007 to December 2018 who underwent initial CIED implantation. Fifteen patients (1.1%) were diagnosed with RV lead perforations. The clinical data were evaluated in those patients, and the baseline characteristics and echocardiographic data were compared between the lead perforation group and the non-perforation group. The success and complication rates of the simple traction and repositioning of the RV lead were also assessed.The number of perforated RV leads was seven ICD leads (1.8%) and eight PM leads (0.82%). They were diagnosed on a median seven days (5.5-36.0) after the CIED implantation. Twelve patients were asymptomatic but were detected by an increased capture threshold. Three patients had pericarditis and stimulation of the diaphragm. Only one patient in the ICD lead group who took anticoagulants had a cardiac tamponade and needed an urgent pericardiocentesis (0.07%). No one required a thoracotomy or other devices related to complications after repositioning the RV lead. There was no significant difference in the baseline characteristics and echocardiographic parameters between the groups.RV lead perforations were relatively rare complications of CIED implantations. Percutaneous simple lead traction and repositioning the perforated lead was feasible and effective if the patients did not receive anticoagulants.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Traumatismos Cardíacos/terapia , Chumbo/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese , Estudos Retrospectivos
19.
J Cardiovasc Electrophysiol ; 30(8): 1330-1338, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31222862

RESUMO

INTRODUCTION: The influence of power (Watt [W]) and total energy (Joule [J]) on lesion size and the optimal overlap ratio remain unclear in laser balloon (LB) ablation for atrial fibrillation. We aimed to evaluate lesion size and visible gaps after LB ablation with various energy settings and different overlap ratios in vitro model. METHODS AND RESULTS: Chicken muscles were cauterized using the first-generation LB with single applications of full and a half duration of six energy settings (5.5 W/30 seconds [165 J] to 12 W/20 seconds [240 J]) and varying power (5.5-12 W) at the constant total energy (160 J). Three overlapped ablations with different ratios (25% and 50%) for each energy setting were also performed to evaluate the visible gap degree categorized from 1 (perfect) to 3 (poor). Twenty lesions were evaluated for each energy setting. In single applications of full duration, lesion depth, lesion volume, and maximum lesion diameter increased according to the total energy (all, P < .001) and were greater than in those of half duration in each energy setting (all, P < .05). However, applications with larger power created larger lesion volume and maximum lesion diameter at constant total energy (P < .05). The visible gap degree was better in all energy settings with 50% overlapped ablation than in those with 25% (all, P < .001). CONCLUSION: Lesion size depends not only on power but also on total energy in the LB ablation. Sufficiently overlapped ablations allow continuous lesion formation.


Assuntos
Terapia a Laser/instrumentação , Músculo Esquelético/cirurgia , Animais , Galinhas , Técnicas In Vitro , Terapia a Laser/efeitos adversos , Músculo Esquelético/patologia , Fatores de Tempo
20.
Europace ; 20(8): 1259-1267, 2018 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016780

RESUMO

Aims: Vagal responses such as marked bradycardia or a rapid blood pressure decrease are often observed during pulmonary vein (PV) isolation of atrial fibrillation (AF) using a cryoballoon (CB). However, the relationship between the marked vagal response and change in the heart rate variability (HRV) as a marker of the autonomic tone is not well understood. Methods and results: Fifty-four paroxysmal AF patients underwent CB ablation. The CB ablation was started from the right sided PVs in 25 patients (R group) and left sided PVs in 29 (L group). The HRV and haemodynamic status during the procedure were analysed. A vagal response was observed in 16 L group patients (61.5%) during the ablation of the different PVs (RSPV:1, RIPV:5, LSPV:15, LIPV:5), while it was observed in only 2 R group patients (9.5%) (RSPV:0, RIPV:0, LSPV:1, LIPV:1) (P = 0.0002). The HRV in the L group was significantly higher than that in the R group just after the CB ablation especially for the left sided PVs (L group vs. R group, total power of the HRV, median; RSPV, 11184.7 vs. 4360.0, P = 0.21; RIPV, 9044.3 vs. 2115.1, P = 0.01; LSPV, 21186.0 vs. 1314.2, P = 0.0002; LIPV 10265.9 vs. 1236.2, P = 0.0007). Conclusion: A marked increase in the HRV parameters was observed just after the CB ablation. An initial CB ablation of the right PVs decreased the change in the autonomic tone during the right PV ablation and subsequent left PV ablation. It prevented an excessive vagal response during the CB ablation and might be a safe procedure.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia , Frequência Cardíaca , Coração/inervação , Veias Pulmonares/cirurgia , Nervo Vago/fisiopatologia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento