Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
J Anesth ; 28(1): 38-50, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23912755

RESUMO

PURPOSE: We evaluated the safety and efficacy of long-term administration of dexmedetomidine in patients in the intensive care unit (ICU). Primary endpoint was the incidence of hypotension, hypertension, and bradycardia. Secondary endpoints were withdrawal symptoms, rebound effects, the duration of sedation with Richmond Agitation-Sedation Scale (RASS) ≤ 0 relative to the total infusion time of dexmedetomidine, and the dose of additional sedatives or analgesics. METHODS: Dexmedetomidine 0.2-0.7 µg/kg/h was continuously infused for maintaining RASS ≤ 0 in patients requiring sedation in the ICU. Safety and efficacy of short-term (≤ 24 h) and long-term (>24 h) dexmedetomidine administration were compared. RESULTS: Seventy-five surgical and medical ICU patients were administered dexmedetomidine. The incidence of hypotension, hypertension, and bradycardia that occurred after 24 h (long-term) was not significantly different from that occurring within 24 h (short-term) (P = 0.546, 0.513, and 0.486, respectively). Regarding withdrawal symptoms, one event each of hypertension and headache occurred after the end of infusion, but both were mild in severity. Increases of mean arterial blood pressure and heart rate after terminating the infusion of dexmedetomidine were not associated with the increasing duration of its infusion. The ratio of duration with RASS ≤ 0 was ≥ 85 % until day 20, except day 9 (70 %) and day 10 (75 %). There was no increase in the dose of additional sedatives or analgesics after the first 24-h treatment period. CONCLUSIONS: Long-term safety of dexmedetomidine compared to its use for 24 h was confirmed. Dexmedetomidine was useful to maintain an adequate sedation level (RASS ≤ 0) during long-term infusion.


Assuntos
Analgésicos/uso terapêutico , Dexmedetomidina/administração & dosagem , Hipnóticos e Sedativos/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Estado Terminal , Dexmedetomidina/efeitos adversos , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Hipnóticos e Sedativos/efeitos adversos , Hipotensão/epidemiologia , Unidades de Terapia Intensiva , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
3.
J Comput Assist Tomogr ; 33(1): 58-62, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19188786

RESUMO

PURPOSE: To evaluate the findings of magnetic resonance mammography for suspicious nipple discharge based on breast imaging-reporting and data system magnetic resonance imaging (MRI) descriptors and establish any correlations with the histopathologic diagnoses. METHODS: Forty-seven patients with suspicious nipple discharge underwent MRI using a 1.5-T system. Images were evaluated for a signal of abnormal discharge, related abnormal enhancement according to the breast imaging-reporting and data system MRI descriptors, and the presence of clustered ring enhancement and were compared with the histopathologic diagnoses established in 39 lesions. RESULTS: The most common finding in patients with suspicious nipple discharge was non-masslike enhancement. Seventeen malignant and 22 benign lesions were detected. The most frequent findings in the malignant lesions were "segmental" (59%), "heterogeneous" (57%), and plateau pattern (40%). Clustered ring enhancement was found in 60% of the enhanced malignant lesions (P = 0.002). The combination of segmental distribution and clustered ring enhancement showed a significant association with malignant lesions (P = 0.004). CONCLUSIONS: Magnetic resonance imaging provides clinically useful information in patients with suspicious nipple discharge.


Assuntos
Algoritmos , Doenças Mamárias/diagnóstico , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Mamilos/patologia , Reconhecimento Automatizado de Padrão/métodos , Adulto , Idoso , Diagnóstico Diferencial , Feminino , Humanos , Aumento da Imagem/métodos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Eur J Radiol ; 84(6): 1191-5, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25802206

RESUMO

PURPOSE: To evaluate the prevalence rates and the correlations of thoracic computed tomography (CT) findings of neurofibromatosis 1 (NF1) in 88 patients. MATERIALS AND METHODS: Chest CT images of 88 NF1 patients were independently reviewed by three observers, and the CT findings were evaluated. If abnormal findings were present, their number, size, and distribution were recorded. The prevalence rate of each CT finding was calculated, and the correlations between CT findings were analyzed. RESULTS: Of the 88 cases, 13 were positive for cysts, 16 for emphysema, 8 for nodules, 8 for GGNs (ground glass nodules), 13 for mediastinal masses, 20 for scoliosis, 44 for subcutaneous nodules, and 34 for skin nodules. Cysts showed upper and peripheral dominant distributions. Regarding 13 mediastinal masses, 2 were diagnosed as malignant peripheral nerve sheath tumors (MPNSTs), 1 was diagnosed as primary lung cancer, 2 were diagnosed as lateral meningocele, 3 were diagnosed as neurofibromas, and the remaining 7 were considered neurofibromas. There was a significant correlation between the prevalence of subcutaneous nodules and that of skin nodules. Significant positive correlations were also seen between size and number, size and rate of central distribution, and number and rate of central distribution of cysts. CONCLUSION: Various CT findings were found in NF-1 patients, and the prevalence rates of subcutaneous and skin nodules were higher than other findings. Though the prevalence rates of subcutaneous nodules and skin nodules were significantly correlated, the other CT findings in NF-1 occurred independently. The number, size, and distribution of the cysts showed significant positive correlations with each other.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias de Bainha Neural/diagnóstico por imagem , Neurofibromatose 1/diagnóstico por imagem , Neoplasias Cutâneas/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/epidemiologia , Masculino , Pessoa de Meia-Idade , Neurofibromatose 1/epidemiologia , Variações Dependentes do Observador , Prevalência , Estudos Retrospectivos , Neoplasias Cutâneas/epidemiologia , Adulto Jovem
5.
Acad Radiol ; 21(6): 695-703, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24713541

RESUMO

RATIONALE AND OBJECTIVES: To compare quality of ultra-low-dose thin-section computed tomography (CT) images of the lung reconstructed using model-based iterative reconstruction (MBIR) and adaptive statistical iterative reconstruction (ASIR) to filtered back projection (FBP) and to determine the minimum tube current-time product on MBIR images by comparing to standard-dose FBP images. MATERIALS AND METHODS: Ten cadaveric lungs were scanned using 120 kVp and four different tube current-time products (8, 16, 32, and 80 mAs). Thin-section images were reconstructed using MBIR, three ASIR blends (30%, 60%, and 90%), and FBP. Using the 8-mAs data, side-to-side comparison of the four iterative reconstruction image sets to FBP was performed by two independent observers who evaluated normal and abnormal findings, subjective image noise, streak artifact, and overall image quality. Image noise was also measured quantitatively. Subsequently, 8-, 16-, and 32-mAs MBIR images were compared to standard-dose FBP images. Comparisons of image sets were analyzed using the Wilcoxon signed rank test with Bonferroni correction. RESULTS: At 8 mAs, MBIR images were significantly better (P < .005) than other reconstruction techniques except in evaluation of interlobular septal thickening. Each set of low-dose MBIR images had significantly lower (P < .001) subjective and objective noise and streak artifacts than standard-dose FBP images. Conspicuity and visibility of normal and abnormal findings were not significantly different between 16-mAs MBIR and 80-mAs FBP images except in identification of intralobular reticular opacities. CONCLUSIONS: MBIR imaging shows higher overall quality with lower noise and streak artifacts than ASIR or FBP imaging, resulting in nearly 80% dose reduction without any degradations of overall image quality.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Pulmão/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Artefatos , Cadáver , Humanos , Variações Dependentes do Observador , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Eur J Radiol ; 83(6): 1016-1021, 2014 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-24721003

RESUMO

PURPOSE: To evaluate the intracystic MRI (magnetic resonance imaging) signal intensity of mediastinal cystic masses on T2-weighted images. MATERIALS AND METHODS: A phantom study was performed to evaluate the signal intensity of a mediastinal cystic mass phantom (rubber balloon containing water) adjacent to a cardiac phantom pulsing at the rate of 60/min. T2-weighted images (sequence, fast spin echo [FSE] and single shot fast spin echo [SSFSE]) were acquired for the mediastinal cystic mass phantom. Further, a clinical study was performed in 33 patients (16 men, 17 women; age range, 19-85 years; mean, 65 years) with thymic cysts or pericardial cysts. In all patients, T2-weighted images (FSE and SSFSE) were acquired. The signal intensity of cystic lesion was evaluated and was compared with that of muscle. A region of interest (ROI) was positioned on the standard MR console, and signal intensity of the cystic mass (cSI), that of the muscle (mSI), and the rate of absolute value of cSI-mSI to standard deviation (SD) of background noise (|cSI-mSI|/SD=CNR [contrast-to-noise ratio]) were measured. RESULTS: The phantom study demonstrated that the rate phantom-ROI/saline-ROI was higher in SSFSE (0.36) than in FSE (0.19). In clinical cases, the degree of the signal intensity was higher in SSFSE than in FSE. The CNR was significantly higher in SSFSE (mean ± standard deviation, 111.0 ± 47.6) than in FSE (72.8 ± 36.6) (p<0.001, Wilcoxon signed-rank test). CONCLUSIONS: Anterior mediastinal cysts often show lower signal intensity than the original signal intensity of water on T2-weighted images. SSFSE sequence reduces this paradoxical signal pattern on T2-weighted images, which may otherwise cause misinterpretation when assessing cystic lesions.


Assuntos
Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Cisto Mediastínico/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA