Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Hand Surg Eur Vol ; 37(4): 329-35, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22076730

RESUMO

The aim of this retrospective cross-sectional study was to assess vascular repair modalities and function in type IV ring finger replantations. Thirty-seven of 43 patients with complete ring avulsion amputations were replanted. After resection of the damaged arterial segments under microscopic magnification the arterial flow pattern was evaluated. The type of repair was chosen according to the adequacy of arterial flow and the defect between the vessels. The methods of bridging the arterial defect consisted of digital artery transfer from adjacent digit in 21 fingers, vein graft interposition in six fingers and end to end anastomosis in ten fingers. Thirty-one of the 37 fingers survived. The failures were due to four arterial and two venous insufficiencies. In our opinion, radical resection of damaged zones of vessels is important to evaluate the proximal flow pattern and decide which treatment modality is necessary for healthy vascular anastomosis.


Assuntos
Amputação Traumática/cirurgia , Traumatismos dos Dedos/cirurgia , Reimplante/métodos , Adolescente , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
2.
J Hand Surg Eur Vol ; 36(4): 320-4, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21282227

RESUMO

Fixation of unstable distal radius fractures with palmar locking plates provides a stable reduction and early return of function, but complications arising from unrecognized dorsally prominent screws penetrating the extensor compartments are increasingly reported. Standard radiographs and fluoroscopy may not adequately visualize screw lengths, owing to the complex shape of the dorsum of the distal radius. We examined 46 distal radius fractures treated with palmar locking plates by ultrasound. Of the total 230 locking screws, 59 protruded from the dorsal cortical surface by 0.5 mm or more (range 0.5-6.1 mm). The first extensor compartment was violated by one screw, the second compartment by 22 screws, the third compartment by 15 screws, and the fourth compartment by 21 screws. Asymptomatic tenosynovitis was detected in four and symptomatic tenosynovitis in 14 of the 59 prominent screws. Ultrasound imaging may be useful in cases where intra-articular and/or comminuted fractures require distal plate placement and engagement of screws in the dorsal cortex.


Assuntos
Fixação Interna de Fraturas/instrumentação , Fraturas do Rádio/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Placas Ósseas , Parafusos Ósseos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas do Rádio/complicações , Fraturas do Rádio/diagnóstico por imagem , Tenossinovite/etiologia , Articulação do Punho/diagnóstico por imagem
3.
J Hand Surg Eur Vol ; 36(5): 383-91, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21406567

RESUMO

We analysed 6549 hand injuries treated between 1992 and 2005 at a specialist hospital in Turkey to identify risk factors for amputations. There were 2899 (44%) hand amputations. Left-side injuries were more prone to amputation. The risk of amputation was higher in men, workers and those in the 15-24 and 45-54 year-old age groups. Compared to home, commercial areas were the places with highest risk, followed by farms and industrial/construction areas. The majority of amputations occurred in industrial/construction areas (87%). Among objects/substances producing injury, watercraft led to the highest risk of amputation and contact with machinery was the mechanism with highest risk. Press machines were the most frequent objects causing amputation both in men and women, followed almost equally by powered wood cutters in men. Doors were the most frequent objects of amputation in children, followed by powered wood cutters. Education, enforcement, and improved engineering are the keys to prevent amputations. Precluding illegal child labour is essential.


Assuntos
Acidentes Domésticos/estatística & dados numéricos , Acidentes de Trabalho/estatística & dados numéricos , Amputação Traumática/epidemiologia , Amputação Traumática/etiologia , Traumatismos da Mão/epidemiologia , Traumatismos da Mão/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Reimplante/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Turquia/epidemiologia
4.
J Hand Surg Eur Vol ; 36(3): 179-84, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21045019

RESUMO

A variety of flaps have been described to treat longitudinal soft tissue defects located on the dorsal aspect of the fingers. We report 13 dorsal soft tissue defects in four patients in which unipedicle laterodigital transposition flaps were used for reconstruction. This flap is especially useful for the reconstruction of long and narrow defects located on the dorsal region of the fingers in multi-digit injuries.


Assuntos
Traumatismos dos Dedos/cirurgia , Procedimentos de Cirurgia Plástica , Retalhos Cirúrgicos , Adulto , Estudos de Coortes , Feminino , Traumatismos dos Dedos/complicações , Traumatismos dos Dedos/patologia , Articulações dos Dedos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular/fisiologia , Recuperação de Função Fisiológica , Estudos Retrospectivos , Resultado do Tratamento
5.
J Bone Joint Surg Br ; 91(6): 762-5, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19483229

RESUMO

We prospectively studied 26 consecutive patients with clinically documented sensory or motor deficiency of a peripheral nerve due to trauma or entrapment using ultrasound, and in 19 cases surgical exploration of the nerves was undertaken. The ultrasonographic diagnoses were correlated with neurological examination and the surgical findings. Reliable visualisation of injured nerves on ultrasonography was achieved in all patients. Axonal swelling and hypoechogenity of the nerve was diagnosed in 15 cases, loss of continuity of a nerve bundle in 17, the formation of a neuroma of a stump in six, and partial laceration of a nerve with loss of the normal fascicular pattern in five. The ultrasonographic findings were confirmed at operation in those who had surgery. Ultrasound may be used for the evaluation of peripheral nerve injuries in the upper limb. High-resolution ultrasound can show the exact location, extent and type of lesion, yielding important information that might not be obtainable by other diagnostic aids.


Assuntos
Complicações Intraoperatórias/diagnóstico por imagem , Nervo Radial/lesões , Nervo Ulnar/lesões , Extremidade Superior/inervação , Adolescente , Adulto , Idoso , Criança , Feminino , Humanos , Fraturas do Úmero/complicações , Complicações Intraoperatórias/cirurgia , Masculino , Pessoa de Meia-Idade , Nervo Musculocutâneo/diagnóstico por imagem , Nervo Musculocutâneo/lesões , Prognóstico , Estudos Prospectivos , Nervo Radial/diagnóstico por imagem , Nervo Radial/cirurgia , Índice de Gravidade de Doença , Nervo Ulnar/diagnóstico por imagem , Nervo Ulnar/cirurgia , Ultrassonografia , Extremidade Superior/diagnóstico por imagem , Extremidade Superior/cirurgia , Adulto Jovem
6.
J Foot Ankle Surg ; 40(3): 158-65, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11417598

RESUMO

Four patients who developed combined tendon and overlying skin defects following operative repair of ruptured Achilles tendon were presented. Three patients had an infected wound. The average interval from the first operation for repairing the ruptured Achilles tendon and the reconstructive procedure was 46.2 days (range, 5-65 days). All patients were treated with a one-stage operation including radical debridement, reconstruction of the Achilles tendon defects using vascularized or nonvascularized tendon grafts, transfer of peroneus brevis for augmentation, and skin coverage with a free flap. The patients recovered uneventfully. The average follow-up period was 39.2 months (range, 18-79 months). In all patients, an evaluation of the clinical outcome, the performance of the calf muscles using a computerized dynamometer, and structural changes of the reconstructed Achilles tendon using magnetic resonance (MR) imaging were made. The clinical outcome was excellent in three patients and good in one. In isokinetic testing (Cybex-Norm), strength was found to be normal in one patient and abnormal in three patients. MR images revealed an intratendinous area of homogenous and normal intensity signal, and a significant increase in thickness and width in all levels of the reconstructed Achilles tendon. The authors conclude that it is possible to obtain satisfactory function in patients with complex wounds in the region of the Achilles tendon.


Assuntos
Tendão do Calcâneo/lesões , Tendão do Calcâneo/cirurgia , Complicações Pós-Operatórias/cirurgia , Retalhos Cirúrgicos , Traumatismos dos Tendões/cirurgia , Tendão do Calcâneo/patologia , Adulto , Procedimentos Cirúrgicos Dermatológicos , Feminino , Humanos , Masculino , Microcirurgia , Pessoa de Meia-Idade , Necrose , Reoperação , Estudos Retrospectivos , Ruptura , Traumatismos dos Tendões/patologia , Transferência Tendinosa , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA