Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BMC Pregnancy Childbirth ; 19(1): 532, 2019 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-31888631

RESUMO

BACKGROUND: Group B Streptococcus (GBS) is one of the most important causative agents of neonatal sepsis. As administration of prophylactic antibiotics during labor can prevent GBS infection, routine screening for this bacterium in prenatal care before the onset of labor is recommended. However, many women present in labor without having undergone such testing during antenatal care, and the turnaround time of detection methods is insufficient for results to be obtained before delivery. METHODS: Vaginal and anorectal specimens were collected from 270 pregnant women. Each sample was tested by Xpert GBS, qPCR, and culture for GBS detection. RESULTS: The overall prevalence of maternal GBS colonization was 30.7% according to Xpert GBS, 51.1% according to qPCR, and 14.3% according to cultures. Considering the qPCR method as the reference, the Xpert GBS had a sensitivity of 53% and specificity of 93%. Positive Xpert GBS results were correlated to marital status (married or cohabitating) and with prematurity as a cause of neonatal hospitalization. Positive cultures were related with ischemic-hypoxic encephalopathy requiring therapeutic hypothermia. CONCLUSIONS: Combined enrichment/qPCR and the Xpert GBS rapid test found a high prevalence of GBS colonization. The Xpert GBS technique gives faster results and could be useful for evaluating mothers who present without antenatal GBS screening results and are at risk of preterm labor, thus allowing institution of prophylactic antibiotic therapy.


Assuntos
Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Complicações Infecciosas na Gravidez/diagnóstico , Diagnóstico Pré-Natal/métodos , Infecções Estreptocócicas/diagnóstico , Streptococcus agalactiae/isolamento & purificação , Adulto , Técnicas Bacteriológicas , Feminino , Humanos , Gravidez , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade , Vagina/microbiologia , Adulto Jovem
2.
ScientificWorldJournal ; 2013: 209737, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24285934

RESUMO

The present study aimed to evaluate the physicochemical parameters and the genotoxic potential of water samples collected in the upper, middle, and lower courses of the Sinos River, southern Brazil. The comet assay was performed in the peripheral blood of fish Hyphessobrycon luetkenii exposed under laboratory conditions to water samples collected in summer and winter in three sampling sites of Sinos River. Water quality analysis demonstrated values above those described in Brazilian legislation in Parobé and Sapucaia do Sul sites, located in the middle and in the lower courses of the Sinos River, respectively. The Caraá site, located in the upper river reach, presented all the physicochemical parameters in accordance with the allowed limits in both sampling periods. Comet assay in fish revealed genotoxicity in water samples collected in the middle course site in summer and in the three sites in winter when compared to control group. Thus, the physicochemical parameters indicated that the water quality of the upper course complies with the limits set by the national guidelines, and the ecotoxicological assessment, however, indicated the presence of genotoxic agents. The present study highlights the importance of combining water physicochemical analysis and bioassays to river monitoring.


Assuntos
Monitoramento Ambiental/métodos , Testes de Mutagenicidade/métodos , Rios/química , Animais , Brasil , Ensaio Cometa , Peixes , Qualidade da Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA