Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 20(1)2020 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-31906283

RESUMO

Optical sensors, such as fiber Bragg gratings, offer advantages compared to other sensors in many technological fields due to their outstanding characteristics. This sensor technology is currently transferred to polymer waveguides that provide the potential for cost-effective, easy, and flexible manufacturing of planar structures. While sensor production itself, in the majority of cases, is performed by means of phase mask technique, which is limited in terms of its degrees of freedom, other inscription techniques enable the manufacture of more adaptable sensor elements for a wider range of applications. In this article, we demonstrate the point-by-point femtosecond laser direct inscription method for the processing of polymer Bragg gratings into waveguides of the epoxy-based negative photoresist material EpoCore for a wavelength range around 850 nm. By characterizing the obtained grating back-reflection of the produced sensing element, we determined the sensitivity for the state variables temperature, humidity, and strain to be 45 pm/K, 19 pm/%, and 0.26 pm/µÎµ, respectively. Individual and more complex grating structures can be developed from this information, thus opening new fields of utilization.

2.
Opt Lett ; 43(21): 5347-5350, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30383004

RESUMO

This Letter describes the design, production, and characterization of a 1×2 arrayed waveguide grating (AWG) for fiber Bragg grating (FBG) readout, centered at 850 nm, with a channel spacing of 1 nm. The employed manufacturing process is laser direct lithography, a low-cost, rapid-prototyping capable, maskless method that allows for short iteration cycles and simple migration of a successful design to mask-based high throughput methods. We also consider the achievable AWG performance if used for strain or temperature measurements with FBG sensors.

3.
Sensors (Basel) ; 17(3)2017 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-28273849

RESUMO

We present a full-polymer respiratory monitoring device suited for application in environments with strong magnetic fields (e.g., during an MRI measurement). The sensor is based on the well-known evanescent field method and consists of a 1 mm plastic optical fiber with a bent region where the cladding is removed and the fiber is coated with poly-dimethylacrylamide (PDMAA). The combination of materials allows for a mass-production of the device by spray-coating and enables integration in disposable medical devices like oxygen masks, which we demonstrate here. We also present results of the application of an autocorrelation-based algorithm for respiratory frequency determination that is relevant for real applications of the device.

4.
Chemosphere ; 161: 112-118, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27423128

RESUMO

We combine confocal Raman microscopy (CRM) of wet samples with subsequent Fluorescent in situ hybridization (FISH) without significant limitations to either technique for analyzing the same sample of a microbial community on a cell-to-cell basis. This combination of techniques allows a much deeper, more complete understanding of complex environmental samples than provided by either technique alone. The minimalistic approach is based on laboratory glassware with micro-engravings for reproducible localization of the sample at cell scale combined with a fixation and de- and rehydration protocol for the respective techniques. As proof of concept, we analyzed a floc of nitrifying activated sludge, demonstrating that the sample can be tracked with cell-scale precision over different measurements and instruments. The collected information includes the microbial content, spatial shape, variant chemical compositions of the floc matrix and the mineral microparticles embedded within. In addition, the direct comparison of CRM and FISH revealed a difference in reported cell size due to the different cell components targeted by the respective technique. To the best of our knowledge, this is the first report of a direct cell-to-cell comparison of confocal Raman microscopy and Fluorescent in situ hybridization analysis performed on the same sample. An adaptation of the method to include native samples as a starting point is planned for the near future. The micro-engraving approach itself also opens up the possibility of combining other, functionally incompatible techniques as required for further in-depth investigations of low-volume samples.


Assuntos
Biofilmes , Hibridização in Situ Fluorescente , Microscopia Confocal , Esgotos , Análise Espectral Raman
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA