Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Med Phys ; 48(12): 7641-7656, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34651705

RESUMO

PURPOSE: The first purpose of this phantom study was to verify whether a contrast-to-noise ratio (CNR)-driven exposure control (CEC) can maintain target CNR in angiography more precisely compared to a conventional detector dose-driven exposure control (DEC). The second purpose was to estimate the difference between incident air kerma produced by CEC and DEC when both exposure controls reach the same CNR. METHODS: A standardized 3D-printed phantom with an iron foil and a cavity, filled with iodinated contrast material, was developed to measure CNR using different image acquisition settings. This phantom was placed into a stack of polymethylmethacrylate and aluminum plates, simulating a patient equivalent thickness (PET) of 2.5-40 cm. Images were acquired using fluoroscopy and digital radiography modes with CEC using one image quality level and four image quality gradients and DEC having three different detector dose levels. The spatial frequency weighted CNR and incident air kerma were determined. The differences in incident air kerma between DEC and CEC were estimated. RESULTS: When using DEC, CNR decreased continuously with increasing attenuation, while CEC within physical limits maintained a predefined CNR level. Furthermore, CEC could be parameterized to deliver the CNR as a predefined function of PET. To provide a given CNR level, CEC used equal or lower air kerma than DEC. The mean estimated incident air kerma of CEC compared to DEC was between 3% (PET 20 cm) and 40% (PET 27.5 cm) lower in fluoroscopy and between 1% (PET 20 cm) and 55% (PET 2.5 cm) lower in digital radiography while maintaining CNR. CONCLUSION: Within physical and legislative limits, the CEC allows for a flexible adjustment of the CNR as a function of PET. Thus, the CEC enables task-dependent examination protocols with predefined image quality in order to easier achieve the as low as reasonably achievable principle. CEC required equal or lower incident air kerma than DEC to provide similar CNR, which allows for a substantial reduction of skin radiation dose in these situations.


Assuntos
Angiografia , Intensificação de Imagem Radiográfica , Fluoroscopia , Humanos , Imagens de Fantasmas , Doses de Radiação
2.
Phys Med Biol ; 66(6): 065020, 2021 03 12.
Artigo em Inglês | MEDLINE | ID: mdl-33709957

RESUMO

Conventional detector-dose driven exposure controls (DEC) do not consider the contrasting material of interest in angiography. Considering the latter when choosing the acquisition parameters should allow for optimization of x-ray quality and consecutively lead to a substantial reduction of radiation exposure. Therefore, the impact of a material-specific, contrast-to-noise ratio (CNR) driven exposure control (CEC) compared to DEC on radiation exposure was investigated. A 3D-printed phantom containing iron, tantalum, and platinum foils and cavities, filled with iodine, barium, and gas (carbon dioxide), was developed to measure the CNR. This phantom was placed within a stack of polymethylmethacrylate and aluminum plates simulating a patient equivalent thickness (PET) of 2.5-40 cm. Fluoroscopy and digital radiography (DR) were conducted applying either CEC or three, regular DEC protocols with parameter settings used in abdominal interventions. CEC protocols where chosen to achieve material-specific CNR values similar to those of DEC. Incident air kerma at the reference point(Ka,r), using either CEC or DEC, was assessed and possible Ka,r reduction for similar CNR was estimated. We show that CEC provided similar CNR as DEC at the same or lower Ka,r. When imaging barium, iron, and iodine Ka,r was substantially reduced below a PET of 20 cm and between 25 cm and 30 cm for fluoroscopy and Dr When imaging platinum and tantalum using fluoroscopy and DR and gas using DR, the Ka,r reduction was substantially higher. We estimate the Ka,r reduction for these materials between 15% and 84% for fluoroscopy and DR between 15% and 93% depending on the PET. The results of this study demonstrate a high potential for skin dose reduction in abdominal radiology when using a material-specific CEC compared to DEC. This effect is substantial in imaging materials with higher energy K-edges, which is beneficial, for example, in long-lasting embolization procedures with tantalum-based embolization material in young patients with arterio-venous malformations.


Assuntos
Angiografia/métodos , Meios de Contraste , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Bário , Fluoroscopia/métodos , Humanos , Imageamento Tridimensional/métodos , Iodo , Ferro , Tomografia por Emissão de Pósitrons , Doses de Radiação , Exposição à Radiação , Radiografia , Pele/efeitos da radiação , Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA