Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(7)2022 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-35408147

RESUMO

This work investigates sensor fault diagnostics and fault-tolerant control for a voltage source converter based microgrid (model) using a sliding-mode observer. It aims to provide a diagnosis of multiple faults (i.e., magnitude, phase, and harmonics) occurring simultaneously or individually in current/potential transformers. A modified algorithm based on convex optimization is used to determine the gains of the sliding-mode observer, which utilizes the feasibility optimization or trace minimization of a Ricatti equation-based modification of H-Infinity (H∞) constrained linear matrix inequalities. The fault and disturbance estimation method is modified and improved with some corrections in previous works. The stability and finite-time reachability of the observers are also presented for the considered faulty and perturbed microgrid system. A proportional-integral (PI) based control is utilized for the conventional regulations required for frequency and voltage sags occurring in a microgrid. However, the same control block features fault-tolerant control (FTC) functionality. It is attained by incorporating a sliding-mode observer to reconstruct the faults of sensors (transformers), which are fed to the control block after correction. Simulation-based analysis is performed by presenting the results of state/output estimation, state/output estimation errors, fault reconstruction, estimated disturbances, and fault-tolerant control performance. Simulations are performed for sinusoidal, constant, linearly increasing, intermittent, sawtooth, and random sort of often occurring sensor faults. However, this paper includes results for the sinusoidal nature voltage/current sensor (transformer) fault and a linearly increasing type of fault, whereas the remaining results are part of the supplementary data file. The comparison analysis is performed in terms of observer gains being estimated by previously used techniques as compared to the proposed modified approach. It also includes the comparison of the voltage-frequency control implemented with and without the incorporation of the used observer based fault estimation and corrections, in the control block. The faults here are considered for voltage/current sensor transformers, but the approach works for a wide range of sensors.

2.
Sensors (Basel) ; 22(4)2022 Feb 18.
Artigo em Inglês | MEDLINE | ID: mdl-35214494

RESUMO

This paper focuses on robustness and sensitivity analysis for sensor fault diagnosis of a voltage source converter based microgrid model. It uses robust control parameters such as minimum sensitivity parameter (H-), maximum robustness parameter (H∞), and compromised both (H-/H∞), being incorporated in the sliding mode observer theory using the game theoretic saddle point estimation achieved through convex optimization of constrained LMIs. The approach used works in a way that the mentioned robust control parameters are embedded in Hamilton-Jacobi-Isaacs-Equation (HJIE) and are also used to determine the inequality version of HJIE, which is, in terms of the Lyapunov function, faults/disturbances and augmented state/output estimation error as its variables. The stability analysis is also presented by negative definiteness of the same inequality version of HJIE, and additionally, it also gives linear matrix inequalities (LMIs), which are optimized using iterative convex optimization algorithms to give optimal sliding mode observer gains enhanced with robustness to maximal preset values of disturbances and sensitivity to minimal preset values of faults. The enhanced sliding mode observer is used to estimate states, faults, and disturbances using sliding mode observer theory. The optimality of sliding mode observer gains for sensitivity of the observer to minimal faults and robustness to maximal disturbance is a game theoretic saddle point estimation achieved through convex optimization of LMIs. The paper includes results for state estimation errors, faults' estimation/reconstruction, fault estimation errors, and fault-tolerant-control performance for current and potential transformer faults. The considered faults and disturbances in current and potential transformers are sinusoidal nature composite of magnitude/phase/harmonics at the same time.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA