Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Chem ; 94(25): 8867-8873, 2022 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-35699939

RESUMO

Nanomaterial-based biosensors are a promising fit for portable and field-deployable diagnosis sensor devices due to their mass production, miniaturization, and integration capabilities. However, the fabrication of highly stable and reproducible biosensor devices is challenging. In this work, we grow a vertically oriented architecture of zinc oxide nanorods onto the active working area (i.e., the channel between the source and drain) of a field-effect transistor (FET) using a low-temperature hydrothermal method. The glucose oxidase enzyme was immobilized on the zinc oxide nanorod surface by a physical adsorption method to fabricate the electrolyte-gated FET-based glucose biosensor. The electrical properties of the electrolyte-gated FET biosensor were measured with different glucose concentrations. We found a linear increase in current up to 80 mM glucose concentration with high sensitivity (74.78 µA/mMcm2) and a low detection limit (∼0.05 mM). We illustrate a highly reproducible fabrication process of zinc oxide nanorod-based FETs, where vertically grown nanorods with a higher surface-to-volume ratio enhance the enzyme immobilization, provide a microenvironment for longer enzyme activity, and translate to better glucose sensing parameters. Additionally, our electrolyte-gated FET biosensor showed promising application in freshly drawn mouse blood samples. These findings suggest a great opportunity to translate into practical high-performance biosensors for a broad range of analytes.


Assuntos
Técnicas Biossensoriais , Nanotubos , Óxido de Zinco , Animais , Técnicas Biossensoriais/métodos , Eletrólitos , Glucose , Camundongos
2.
Biosensors (Basel) ; 13(3)2023 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-36979587

RESUMO

Early-stage uric acid (UA) abnormality detection is crucial for a healthy human. With the evolution of nanoscience, metal oxide nanostructure-based sensors have become a potential candidate for health monitoring due to their low-cost, easy-to-handle, and portability. Herein, we demonstrate the synthesis of puffy balls-like cobalt oxide nanostructure using a hydrothermal method and utilize them to modify the working electrode for non-enzymatic electrochemical sensor fabrication. The non-enzymatic electrochemical sensor was utilized for UA determination using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The puffy balls-shaped cobalt oxide nanostructure-modified glassy carbon (GC) electrode exhibited excellent electro-catalytic activity during UA detection. Interestingly, when we compared the sensitivity of non-enzymatic electrochemical UA sensors, the DPV technique resulted in high sensitivity (2158 µA/mM.cm2) compared to the CV technique (sensitivity = 307 µA/mM.cm2). The developed non-enzymatic electrochemical UA sensor showed good selectivity, stability, reproducibility, and applicability in the human serum. Moreover, this study indicates that the puffy balls-shaped cobalt oxide nanostructure can be utilized as electrode material for designing (bio)sensors to detect a specific analyte.


Assuntos
Nanoestruturas , Ácido Úrico , Humanos , Reprodutibilidade dos Testes , Óxidos/química , Eletrodos , Técnicas Eletroquímicas/métodos
3.
Acad Pediatr ; 22(3S): S81-S91, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35339248

RESUMO

OBJECTIVE: Context is a critical determinant of the effectiveness of quality improvement programs. We assessed the role of contextual factors in influencing the efforts of 5 diverse quality improvement projects as part of the Pediatric Quality Measure Program (PQMP) directed by the Agency for Health Care Research and Quality. METHODS: We conducted a mixed methods study of 5 PQMP grantees involving semistructured interviews followed by structured worksheets to identify influential contextual factors. Semistructured interviews and worksheets were completed between August and October 2020. Participants were comprised of PQMP grantee teams (2-4 team members per team for a total of 15 participants). Coding and analysis was based on the Tailored Implementation for Chronic Diseases (TICD) framework. RESULTS: Despite heterogeneity in the process and outcome targets of the PQMP initiatives, professional interactions, incentives and resources, and capacity for organizational change were the domains most commonly identified as influential across the grantees. While social, political, and legal factors was not commonly referenced as an important domain, payer or funder policies (a factor within this domain) was highlighted as one of the most influential factors. Overall, the incentives and resources domain was identified as the most influential. CONCLUSIONS: We found that using a determinant framework, such as the TICD, is valuable in facilitating comparisons across heterogeneous projects, allowing us to identify key contextual factors influencing the implementation of pediatric quality measures across a diverse range of clinical topics and settings. Future quality improvement work should account for this and include resources to support infrastructure development in addition to program implementation.


Assuntos
Melhoria de Qualidade , Criança , Humanos , Inovação Organizacional
4.
Biosensors (Basel) ; 12(12)2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36551107

RESUMO

Transition metal oxide (TMO)-based nanomaterials are effectively utilized to fabricate clinically useful ultra-sensitive sensors. Different nanostructured nanomaterials of TMO have attracted a lot of interest from researchers for diverse applications. Herein, we utilized a hydrothermal method to develop porous nanosheets of cobalt oxide. This synthesis method is simple and low temperature-based. The morphology of the porous nanosheets like cobalt oxide was investigated in detail using FESEM and TEM. The morphological investigation confirmed the successful formation of the porous nanosheet-like nanostructure. The crystal characteristic of porous cobalt oxide nanosheets was evaluated by XRD analysis, which confirmed the crystallinity of as-synthesized cobalt oxide nanosheets. The uric acid sensor fabrication involves the fixing of porous cobalt oxide nanosheets onto the GCE (glassy carbon electrode). The non-enzymatic electrochemical sensing was measured using CV and DPV analysis. The application of DPV technique during electrochemical testing for uric acid resulted in ultra-high sensitivity (3566.5 µAmM-1cm-2), which is ~7.58 times better than CV-based sensitivity (470.4 µAmM-1cm-2). Additionally, uric acid sensors were tested for their selectivity and storage ability. The applicability of the uric acid sensors was tested in the serum sample through standard addition and recovery of known uric acid concentration. This ultrasensitive nature of porous cobalt oxide nanosheets could be utilized to realize the sensing of other biomolecules.


Assuntos
Nanoestruturas , Ácido Úrico , Porosidade , Óxidos/química , Nanoestruturas/química , Eletrodos , Técnicas Eletroquímicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA