Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Nature ; 611(7937): 688-694, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36352223

RESUMO

Metal halide perovskites are attracting a lot of attention as next-generation light-emitting materials owing to their excellent emission properties, with narrow band emission1-4. However, perovskite light-emitting diodes (PeLEDs), irrespective of their material type (polycrystals or nanocrystals), have not realized high luminance, high efficiency and long lifetime simultaneously, as they are influenced by intrinsic limitations related to the trade-off of properties between charge transport and confinement in each type of perovskite material5-8. Here, we report an ultra-bright, efficient and stable PeLED made of core/shell perovskite nanocrystals with a size of approximately 10 nm, obtained using a simple in situ reaction of benzylphosphonic acid (BPA) additive with three-dimensional (3D) polycrystalline perovskite films, without separate synthesis processes. During the reaction, large 3D crystals are split into nanocrystals and the BPA surrounds the nanocrystals, achieving strong carrier confinement. The BPA shell passivates the undercoordinated lead atoms by forming covalent bonds, and thereby greatly reduces the trap density while maintaining good charge-transport properties for the 3D perovskites. We demonstrate simultaneously efficient, bright and stable PeLEDs that have a maximum brightness of approximately 470,000 cd m-2, maximum external quantum efficiency of 28.9% (average = 25.2 ± 1.6% over 40 devices), maximum current efficiency of 151 cd A-1 and half-lifetime of 520 h at 1,000 cd m-2 (estimated half-lifetime >30,000 h at 100 cd m-2). Our work sheds light on the possibility that PeLEDs can be commercialized in the future display industry.

2.
Medicina (Kaunas) ; 59(2)2023 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-36837412

RESUMO

Background and Objectives: Left atrial hypertension is one of the pathophysiologies of heart failure with preserved ejection fraction. We hypothesized that left atrial pressure response (LAPR) to incremental pacing is higher in patients with atrial fibrillation (AF) and can predict left ventricular diastolic dysfunction. Materials and Methods: Patients requiring left atrial access as a part of a therapeutic procedure for AF (n = 204, AF group) or supraventricular tachycardia (n = 34, control group) were analyzed (male n = 183, 54 ± 12 years old). LAPR was measured during incremental pacing. Results: Baseline left atrial pressure and LAPR at all pacing rates were not different between the AF and control groups. They were higher in patients with a high E/e' (≥ 8) than in those with a low E/e' (<8). LAPR at a pacing interval of 400 ms and E/e' were positively correlated (r = 0.373, p < 0.001). Body mass index and a high E/e' were independent predictors of pacing-induced left atrial hypertension. Conclusions: LAPR to incremental pacing was constant regardless of AF. The non-invasive echocardiographic marker E/e' reflected pacing-induced left atrial hypertension.


Assuntos
Fibrilação Atrial , Hipertensão , Disfunção Ventricular Esquerda , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Pressão Atrial , Volume Sistólico/fisiologia , Átrios do Coração , Função Ventricular Esquerda/fisiologia
3.
J Med Virol ; 94(6): 2422-2430, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35130367

RESUMO

Infection is associated with the occurrence, recurrence, and progression of atrial fibrillation (AF), and is also closely related to poor prognosis. However, studies of the relationship between infectivity and severe complications of coronavirus infectious disease-19  (COVID-19) with a history of AF are limited. To estimate infectivity and severity of complications in COVID-19 patients with a history of AF, this study was done. From the Korean nationwide COVID-19 dataset, 212 678 participants with at least one severe acute respiratory syndrome coronavirus 2 (COVID-19) test were included between January 1 and June 4, 2020. AF was defined according to at least two outpatient hospital visits or one admission with an ICD-10 code of "I48" before the COVID-19 test. To investigate the association of AF with infectivity and severe complications of COVID-19, 1:4 ratio propensity score matching (PSM) was performed. Severe complications of COVID-19 were defined as a composite outcome of mechanical ventilation, intensive care unit admission, and death within 2 months after COVID-19 diagnosis. Among 212 678 participants who underwent the COVID-19 test, there were 7713 COVID-19 positive patients. After PSM, COVID-19 PCR positivity did not show a significant difference according to the presence of AF (odds ratio [OR]: 0.79, 95% confidence interval [CI]: [0.60-1.04]). Of 7713 COVID-19 patients, 62 (0.8%) had a history of AF and severe complications occurred in 444 (5.7%) patients. After PSM, AF was associated with the development of severe complications (OR: 2.04, 95% CI: [1.10-3.79]) and mortality (OR: 2.09, 95% CI: [1.01-4.31]) of COVID-19. We found that AF was associated with an increased risk of severe complications in COVID-19 infected patients.


Assuntos
Fibrilação Atrial , COVID-19 , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , COVID-19/complicações , Teste para COVID-19 , Estudos de Coortes , Humanos , Fatores de Risco , SARS-CoV-2
4.
J Med Virol ; 94(3): 1138-1145, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34738248

RESUMO

Infection is associated with occurrence and worsening of heart failure (HF). However, studies on the association of susceptibility and severe complications of coronavirus disease 2019 (COVID-19) with HF history are limited. From the Korean nationwide COVID-19 data set, 212,678 participants with at least one severe acute respiratory syndrome coronavirus 2 real-time reverse transcription polymerase chain reaction (RT-PCR) test were included between January 1 and June 4, 2020. To investigate the association of HF with susceptibility and severe complications of COVID-19, 1:4 ratio propensity score matching (PSM) and logistic regression analysis were performed. The primary outcome was a composite outcome of mechanical ventilation, intensive care unit (ICU) admission, and death. After PSM, COVID-19 PCR positivity did not show a significant difference according to HF history in multivariable analysis (odds ratio [OR]: 0.91, 95% confidence interval (CI) (0.79-1.04), p = 0.146). Of 7630 individuals with confirmed COVID-19 infection, 310 (4.1%) had HF history. The overall primary outcome occurred in 426 (5.6%) individuals, including 159 (2.1%) cases of mechanical ventilation, 254 (3.3%) cases of ICU admission, and 215 (2.8%) cases of death. In multivariate logistic analysis, presence of HF history was associated independently with primary outcome (OR: 1.99, 95% CI: 1.42-2.79, p < 0.001), particularly mortality (OR: 2.02, 95% CI: 1.36-3.00, p < 0.001). Our study demonstrated that HF history is associated poor prognosis, particularly mortality, in COVID-19. Patients with HF can have severe complication if infected with COVID-19; therefore, careful management are necessary.


Assuntos
COVID-19 , Insuficiência Cardíaca , COVID-19/complicações , Estudos de Coortes , Insuficiência Cardíaca/complicações , Humanos , Unidades de Terapia Intensiva , SARS-CoV-2
5.
Medicina (Kaunas) ; 57(6)2021 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-34199329

RESUMO

Background and Objectives: Direct current cardioversion (DCCV) is a safe and useful treatment for atrial tachyarrhythmias. In the past, the energy delivered in DCCV was decided upon empirically, based only on the type of tachyarrhythmia. This conventional method does not consider individual factors and may lead to unnecessary electrical damage. Materials and Methods: We performed DCCV in patients with atrial tachyarrhythmias. The impedance and electrical current at the moment of shock were measured. The human thoracic impedance between both defibrillator patches and the electric current that was used were measured. Results: A total of 683 DCCVs were performed on 466 atrial tachyarrhythmia patients. The average impedance was 64 ± 11 Ω and the average successful current was 23 ± 6 mA. The magnitude of the electrical current that was successful depended upon the human impedance (linear regression, B = -0.266, p < 0.001) and the left atrial diameter (B = 0.092, p < 0.001). Impedance was directly proportional to body mass index (BMI) (B = 1.598, p < 0.001) and was higher in females than in males (77 ± 15 Ω vs. 63 ± 11 Ω, p < 0.001). Notably, the high-impedance (>70 Ω) group had a higher BMI (27 ± 4 kg/m2 vs. 25 ± 3 kg/m2, p < 0.001) and a higher proportion of females (37% vs. 9%, p < 0.001) than the low-impedance group (<70 Ω). However, thoracic impedance was not an independent predictor for successful DCCV. Conclusions: Human thoracic impedance was one of the factors that impacted the level of electrical current required for successful DCCV in patients with atrial arrhythmias. In the future, it will be helpful to consider individual predictors, such as BMI and gender, to minimize electrical damage during DCCV.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardioversão Elétrica , Impedância Elétrica , Feminino , Átrios do Coração , Humanos , Masculino
6.
Europace ; 21(4): 598-606, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30649276

RESUMO

AIMS: Findings regarding efficacy of substrate modification for non-paroxysmal atrial fibrillation (AF) are inconsistent. We prospectively compared clinical outcomes of complex fractionated atrial electrogram (CFAE)-guided focal ablation (CFA) and CFAE-guided linear ablation (CLA) in patients with non-paroxysmal AF. METHODS AND RESULTS: We randomized 150 patients with non-paroxysmal AF into CFA and CLA groups in a 1:1 ratio. Complex fractionated atrial electrogram distribution was evaluated using an automated algorithm of a three-dimensional mapping system. After pulmonary vein isolation (PVI), CFAE-guided ablation was performed in the left atrium and then in the right atrium (RA). When compared with conventional CFA, CLA was performed based on conventional lines, with additional lines. Atrial fibrillation was not induced after PVI alone or with cavotricuspid isthmus ablation in 20.7% of patients. To achieve the endpoint, additional CFAE-guided RA ablation was required in 42.7% and 36.0% of patients undergoing CFA and CLA, respectively (P = 0.403). Atrial fibrillation was terminated during CFAE-guided ablation in 72.9% and 75.0% of patients undergoing CFA and CLA, respectively (P = 0.792). Termination of atrial tachycardia (AT) or non-inducibility of AF/AT was achieved in 61.3% and 68.0% of patients undergoing CFA and CLA, respectively (P = 0.393). The CLA group showed decreased 1-year freedom from AF/AT recurrence (60.0%, CFA vs. 47.3%, CLA; log rank P = 0.085), but no significant difference throughout the follow-up (22.2 ± 21.0 months) (67.1%, CFA vs. 68.9%, CLA; log rank P = 0.298). CONCLUSION: Long-term efficacy of CFAE-guided ablation was unaffected by the ablation technique in patients with non-paroxysmal AF.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Veias Pulmonares/cirurgia , Idoso , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
J Cardiovasc Electrophysiol ; 29(10): 1343-1351, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29927012

RESUMO

INTRODUCTION: Radiofrequency catheter ablation (RFCA) in atrial fibrillation (AF) patients can cause various complications and atrioesophageal (AE) fistula is one of the most catastrophic complications of RFCA. METHODS AND RESULTS: RFCA registries from 3 cardiovascular centers in the Republic of Korea consisted of 5721 patients undergoing 6724 procedures. Before undergoing RFCA, patients underwent either computed tomography or magnetic resonance imaging. We evaluated clinical, anatomical, and procedural characteristics of patients who developed AE fistula after RFCA. A total of 10 patients developed AE fistula after RFCA (0.15% per procedure). All AE fistulas occurred during first-time RFCA. Eight patients died and mortality rate was 80.0%. No patients had any gastrointestinal symptom at the time of discharge and mean duration time from RFCA to symptom onset was 23.4 days. Six patients (60.0%) had paroxysmal AF. Substrate modification in addition to pulmonary vein isolation was performed in 4 patients (40.0%). Patients with old age, low body weight, and high CHA2 DS2 -VASc score were at increased risk of AE fistula. Baseline imaging evaluation revealed that esophagus had closest contact with LA posterior wall near left inferior pulmonary vein rather than left superior pulmonary vein and all documented AE fistulas were located near left inferior pulmonary vein. CONCLUSION: Posterior wall of LA near left inferior pulmonary vein was the most vulnerable location for AE fistula. Pulmonary vein isolation was the main lesion set associated with AE fistula and old age, low body weight, and high CHA2 DS2 -VASc score were significant risk factors for AE fistula.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fístula Esofágica/etiologia , Fístula/etiologia , Cardiopatias/etiologia , Veias Pulmonares/cirurgia , Fatores Etários , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/mortalidade , Fibrilação Atrial/fisiopatologia , Peso Corporal , Ablação por Cateter/mortalidade , Ecocardiografia Transesofagiana , Fístula Esofágica/diagnóstico por imagem , Fístula Esofágica/mortalidade , Feminino , Fístula/diagnóstico por imagem , Fístula/mortalidade , Cardiopatias/diagnóstico por imagem , Cardiopatias/mortalidade , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Sistema de Registros , República da Coreia , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
BMC Cardiovasc Disord ; 18(1): 106, 2018 05 30.
Artigo em Inglês | MEDLINE | ID: mdl-29843616

RESUMO

BACKGROUND: There is a controversy as to whether catheter ablation should be the first-line therapy for tachycardia-bradycardia syndrome (TBS) in patients with atrial fibrillation (AF). METHODS: We aimed to investigate long-term clinical outcomes of catheter ablation in patients with TBS and AF. Among 145 consecutive patients who underwent catheter ablation of AF with TBS, 121 patients were studied. RESULTS: Among 121 patients, 11 (9.1%) received implantation of a permanent pacemaker during a mean 21 months after ablation. Length of pause on termination of AF was significantly greater in patients who received pacemaker implantation after ablation than those who underwent ablation only (7.9 ± 3.5 vs. 5.1 ± 2.1 s, p < 0.001). Using a multivariate model, a long pause of 6.3 s or longer after termination of AF was associated with the requirement to implant a permanent pacemaker after ablation (HR 1.332, 95% CI 1.115-1.591, p = 0.002). CONCLUSION: This study suggests that, in patients with AF predisposing to TBS, long pause on termination of AF predicts the need to implant a permanent pacemaker after catheter ablation.


Assuntos
Fibrilação Atrial/cirurgia , Bradicardia/terapia , Estimulação Cardíaca Artificial , Ablação por Cateter , Marca-Passo Artificial , Taquicardia/terapia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Bradicardia/diagnóstico , Bradicardia/fisiopatologia , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Síndrome , Taquicardia/diagnóstico , Taquicardia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 27(7): 788-95, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27062657

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is a common manifestation in cases of hypertrophic cardiomyopathy (HCM). Catheter ablation (CA) for AF in patients with asymmetric septal HCM (SeHCM) is selectively effective and often needs a repeat procedure. Apical HCM (ApHCM) has a better prognosis than SeHCM. However, the outcome of CA for AF in patients with ApHCM is unclear. METHODS AND RESULTS: Eighteen patients with ApHCM (ApHCM group) and 13 SeHCM patients (SeHCM group) underwent CA for AF. Ninety sex-, age-, and AF type-matched non-HCM patients who underwent CA for AF were selected as controls (5 controls for each ApHCM patient). During a median follow-up of 44.7 ± 30.8 months, 50% of the patients remained free from AF/atrial tachycardia (AT) in the ApHCM group. The ApHCM patients displayed enlarged left atrial (LA) diameter (47.1 ± 6.0 mm vs. 42.4 ± 5.5 mm, P = 0.006) and increased E/Ea ratio (13.5 ± 4.4 vs. 9.1 ± 3.1, P < 0.001) as compared to the control group. In contrast, the mean LA diameter and E/Ea ratio of the ApHCM group were not different than those of the SeHCM group. The overall freedom from AF/AT in the ApHCM group was significantly worse than in the control group (log rank P = 0.028), but there was no difference between the ApHCM and SeHCM groups (P = 0.831). High LA diameter index ≥25 mm/m(2) (HR 12.8, 95% CI [1.2-142.1]; P = 0.037) was an independent predictor of AF/AT recurrence among patients with ApHCM. CONCLUSION: Long-term outcome of CA for AF was worse in patients with ApHCM, as compared to controls, but was similar to patients with SeHCM.


Assuntos
Fibrilação Atrial/cirurgia , Cardiomiopatia Hipertrófica/complicações , Ablação por Cateter , Taquicardia Supraventricular/cirurgia , Adulto , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/etiologia , Fibrilação Atrial/fisiopatologia , Cardiomiopatia Hipertrófica/diagnóstico , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Ecocardiografia Doppler , Eletrocardiografia , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taquicardia Supraventricular/diagnóstico , Taquicardia Supraventricular/etiologia , Taquicardia Supraventricular/fisiopatologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
10.
Europace ; 17(9): 1391-401, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25736564

RESUMO

AIMS: Atrial fibrillation (AF) cycle length (CL) has been demonstrated to be one of the predictors for termination during ablation for AF. We evaluated the AF CL gradient between right atrium (RA) and left atrium (LA) and their mean AF CL in predicting the extent of substrate ablation. METHODS AND RESULTS: One-hundred and thirty-six patients undergoing first ablation for persistent AF were studied. Stepwise ablation, sequentially in the following order: pulmonary veins (PV), LA, and RA, was performed to achieve AF termination. Stepwise ablation terminated AF in 110 patients (81%). In the AF termination group, AF was terminated by PV isolation (PVI) (Group P), PVI plus LA ablation (Group L), and PVI plus LA plus RA ablation (Group R) in 14 patients (13%), 49 patients (44%), and 47 patients (43%), respectively. Group R had much shorter mean AF CL than Group L (156 ± 18 vs. 174 ± 24 ms, P < 0.001) and mean AF CL in Group L was much shorter than Group P (174 ± 24 vs. 209 ± 36 ms, P = 0.004). The RA to LA AF CL gradient was not significantly different between left-side ablation (Group P + Group L) and additional RA ablation (Group R) (P = 0.177). Mean AF CL >180.50 ms predicted AF termination by PVI (Group P) with 79% sensitivity and 84% specificity while mean AF CL >165.25 ms predicted AF termination by left-side ablation (Group P + Group L) with 67% sensitivity and 75% specificity. After a mean follow-up of 15 ± 7 months, freedom from arrhythmia recurrence was significantly higher in left-side ablation (Group P + Group L) than additional RA ablation (Group R) (P = 0.024). CONCLUSION: Baseline mean AF CL may identify the subset of patients in whom persistent AF can be terminated by different extent of substrate ablation, which may in turn predict the chance of recurrence. However, baseline RA to LA AF CL gradient cannot predict the need for additional RA ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/fisiopatologia , Veias Pulmonares/cirurgia , Idoso , Eletrocardiografia , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Prognóstico , Recidiva , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA