Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 36
Filtrar
1.
Circulation ; 130(11 Suppl 1): S39-44, 2014 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-25200054

RESUMO

BACKGROUND: Optimal management strategy of acute aortic dissection (AD) with retrograde extension from entry tear in the descending aorta into the ascending aorta remains undetermined. METHODS AND RESULTS: Of the 538 patients who were diagnosed as having acute AD from 1999 through 2011, 49 patients (37 men; 52.5±13.1 years) were identified as having entry tear in the descending aorta with retrograde extension of AD into the ascending aorta. Sixteen patients who were clinically stable with thrombosed false lumen in the ascending aorta were treated medically (MED group), whereas 33 patients underwent aortic replacement (SURG group) on an intention-to-treat basis. In the MED group, 1 patient was converted to urgent aortic surgery and 2 patients underwent endovascular stent grafting in the descending aorta during the initial hospitalization. The early (30-day or in-hospital) mortality rates were 0% and 9.1% in the MED and SURG group, respectively (P=0.54). Follow-up was complete in all patients (median, 61.4 months; Q1-Q3, 28.2-99.1 months). The 5-year 100% survival rate in the MED group was higher than that in the SURG group (81.2±7.0%; P=0.080), in the surgically treated patients with antegrade type A AD (74.5±2.8%; P=0.038), and in the patients with type B AD (75.3±3.3%; P=0.045). Aortic event-free survival at 5 years was 52.7±14.8% and 69.6±8.0% in the MED and SURG groups, respectively (P=0.98). CONCLUSIONS: Patients with acute retrograde type A AD showed a more favorable prognosis than patients with antegrade AD. In selected patients with retrograde type A AD, excellent outcomes could be achieved with initial medical management combined with timely interventions.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Ruptura Aórtica/cirurgia , Doença Aguda , Adulto , Idoso , Aorta/patologia , Doenças da Aorta/etiologia , Implante de Prótese Vascular , Procedimentos Cirúrgicos Cardíacos , Ponte Cardiopulmonar , Causas de Morte , Intervalo Livre de Doença , Emergências , Procedimentos Endovasculares , Feminino , Seguimentos , Mortalidade Hospitalar , Humanos , Hipotermia Induzida , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Prognóstico , Stents , Trombose/etiologia , Resultado do Tratamento
2.
Heliyon ; 10(6): e27310, 2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38509976

RESUMO

Since the introduction of transcatheter aortic valve (AV) implantation as a viable option, surgical bioprosthetic AVs have recently started incorporating shorter struts considering future valve-in-valve procedures. However, the effect of leaflet coaptation geometry on the longevity of these valves remains unexplored. To address this gap, we performed a finite element analysis on bioprosthetic AVs with varying strut heights using a two-way fluid-structure interaction method. To establish a baseline, we used a standard height based on a rendered platform image of the CE PERIMOUNT Magna Ease valve from Edward Lifesciences in Irvine, CA. Bovine pericardium properties were assigned to the leaflets, while normal saline properties were used as the recirculating fluid in hemodynamic simulations. The physiological pressure profile of the cardiac cycle was applied between the aorta and left ventricle. We calculated blood flow velocity, effective orifice area (EOA), and mechanical stress on the leaflets. The results reveal that as the strut height increases, the stroke volume increases, leakage volume decreases, and EOA improves. Additionally, the maximum mechanical stress experienced by the leaflet decreases by 62% as the strut height increases to 1.2 times the standard height. This research highlights that a low-strut design in bioprosthetic AVs may negatively affect their durability, which can be useful in design of next-generation bioprosthetic AVs.

3.
J Thorac Cardiovasc Surg ; 167(1): 116-126.e1, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-35248358

RESUMO

OBJECTIVES: The study objective was to evaluate the clinical implication of left ventricular diastolic dysfunction in patients with chronic severe aortic regurgitation undergoing aortic valve replacement. METHODS: We reviewed the medical records of 323 patients (age, 56.3 ± 14.1 years; 111 female) who underwent aortic valve replacement for chronic severe aortic regurgitation between 2005 and 2019. Left ventricular diastolic dysfunction was assessed by the ratio of peak left ventricular inflow velocity over mitral annular velocity (E/e'). The study end point was the composite of death and heart failure requiring hospital admission. RESULTS: The E/e' ratio was significantly correlated with age, left atrial dimension, left ventricular end-diastolic volume, mitral regurgitation grade, and tricuspid regurgitation grade (all P < .001). During follow-up (1748.3 patient-years), death and heart failure occurred in 36 patients (2.06/patient-year) and 9 patients (0.53/patient-year), respectively. In multivariable analysis, E/e' ratio (per 5 increment, hazard ratio, 1.32; 95% confidence interval, 1.02-1.71; P = .03), age (hazard ratio, 1.06; 95% confidence interval, 1.03-1.10; P < .001), and left ventricular ejection fraction (hazard ratio, 0.94; 95% confidence interval, 0.90-0.98; P = .002) were independent predictors of death and heart failure. The 5-year heart failure-free survival was 94.9% ± 1.7% in patients with E/e' less than 15% and 84.2% ± 4.2% in patients with E/e' 15 or greater (P < .001). CONCLUSIONS: The E/e' ratio was significantly associated with adverse outcomes in patients with chronic severe aortic regurgitation undergoing aortic valve replacement and may be useful as a prognostic marker in such patients.


Assuntos
Insuficiência da Valva Aórtica , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Prognóstico , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/etiologia
4.
Front Cardiovasc Med ; 10: 1305824, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38045912

RESUMO

Introduction: Amlodipine, widely used as a first-line treatment for hypertension, has inconclusive clinical evidence regarding its efficacy in patients with heart failure. This retrospective cohort study aimed to investigate the clinical effectiveness of amlodipine treatment after hospitalization for heart failure in patients with dilated cardiomyopathy (DCMP). Methods: A total of 20,851 patients who were diagnosed with DCMP and admitted for heart failure between 2005 and 2016 according to Korean nationwide medical insurance service database were enrolled. Amlodipine use was defined as its prescription at the time of discharge and for at least 180 days within a year. The primary outcome was all-cause death, and the secondary outcome was heart failure rehospitalization during a 5-year period. The outcomes between patients who received amlodipine (n = 6,798) and those who did not (n = 14,053) were compared. Results: During the 5-year follow-up, the group treated with amlodipine exhibited a significantly lower risk of all-cause death and heart failure rehospitalization than the group not treated with amlodipine [all-cause death: adjusted hazard ratio (HR): 0.64, 95% confidence interval (CI): 0.59-0.70, p < 0.001; cardiovascular death: adjusted HR: 0.71, 95% CI: 0.62-0.81, p < 0.001; heart failure rehospitalization: adjusted HR: 0.92, 95% CI: 0.86-0.98, p = 0.006]. In a subgroup analysis, amlodipine had a significant impact on decreasing all-cause mortality in older adults, those with a higher systolic blood pressure, and those with a lower Charlson Comorbidity Index. Conclusion: In summary, amlodipine use after hospitalization for heart failure in patients with DCMP was associated with a lower risk of all-cause death and readmission for heart failure.

5.
J Thorac Dis ; 15(11): 5942-5951, 2023 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-38090294

RESUMO

Background: Reports on the residual descending aortic dissection (AD) after acute type A AD (TAAD) repair has been limited. Therefore, we evaluated the fate of descending aorta in patients who underwent acute TAAD repair. Methods: We reviewed 299 patients (mean: 60.4 years, 51.5% male) patients who received acute TAAD repair between 2009 and 2018, except genetic aortopathy and concomitant surgeries for the descending aorta. Subjects are categorized into classic TAAD (Classic, n=226), retrograde extension of TAAD from the intimal tear in the descending aorta (Retro, n=31), and intramural hematoma (IMH, n=42) types of AD. Interested outcome was expansion rate of descending aorta. Secondary outcome was descending aorta events including surgical repair, interventions, and aortic rupture. To reduce selection bias, baseline variables were adjusted. Multivariable risk analyses were performed to find risk factors of the study outcomes. Results: In crude analysis, descending aorta in Retro [beta, 2.260; standard error (SE), 0.559] and Classic (beta, 1.542; SE, 0.233) groups expanded faster than IMH (beta, 0.443; SE, 0.491) group. Unadjusted risk of aortic event was significantly higher in the Retro group compared with the IMH [hazard ratio (HR) =4.80; 95% confidence interval (CI): 1.56-14.7] and Classic (HR =2.36; 95% CI: 1.24-4.49) groups. Baseline adjustment did not alter these findings. In multivariable analyses, the presence of intimal tear in the upper thoracic descending aorta (above 7th thoracic vertebra) was significantly associated with the aortic expansion (beta, 2.06; SE, 0.61) and events (HR =8.74; 95% CI: 4.34-17.6). Conclusions: The descending aorta growth was faster in Retro and Classic than IMH and related with the tear location. Careful assessment on the descending is warranted.

6.
J Chest Surg ; 56(4): 255-261, 2023 Jul 05.
Artigo em Inglês | MEDLINE | ID: mdl-37096250

RESUMO

Background: The surgical threshold for bicuspid aortic valve (BAV)-related aortopathy is a matter of debate due to its uncertain etiology and prognosis. This study investigated the prognosis of unrepaired BAV aortopathy in patients undergoing surgical aortic valve replacement (SAVR). Methods: We retrospectively analyzed data from 720 patients (age, 60.8±11.5 years; 246 women) who underwent SAVR for BAV disease without aortic repair between 2005 and 2020 at Asan Medical Center. The clinical endpoints were defined as occurrences of sudden death, aortic dissection or rupture, and elective aortic repair. To estimate postoperative changes in the dimensions of the unrepaired aorta, the individual annual aortic expansion rate was calculated. Multiple linear regression models were used to evaluate the risk of aortic expansion. Results: The mean ascending aortic diameter was 39.5±4.6 mm, and 299 patients (41.5%) had a baseline ascending aorta diameter >40 mm. During 70.0±68.3 months of follow-up, the mean annual aortic expansion rate was 0.39±1.96 mm/yr, no aortic dissection or rupture was observed, and sudden deaths were reported in 12 patients (0.34% per person-year). Linear regression analysis revealed no significant correlation between the baseline ascending aortic diameter and postoperative aortic expansion (R2=0.004, ß=-0.84, p=0.082). Conclusion: In selected patients undergoing SAVR for a BAV (<55 mm), the risk of adverse aortic events was very low. As this observation contradicts current practice guidelines advocating for proactive aortic replacement in dilated ascending aortas measuring >45 mm, the study results need further validation by studies involving larger populations or randomized controlled trials.

7.
J Thorac Cardiovasc Surg ; 165(4): 1374-1383.e7, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-34154801

RESUMO

OBJECTIVE: Tricuspid valve repair for mild tricuspid regurgitation during rheumatic mitral valve surgery is controversial. We evaluated the benefit of tricuspid valve repair for mild tricuspid regurgitation in rheumatic mitral valve surgery. METHODS: Among 1208 consecutive patients (52.6 ± 11.9 years) with mild tricuspid regurgitation who underwent rheumatic mitral valve surgery from 2000 to 2018 in 2 referral centers, 419 received concomitant tricuspid valve repair and 789 did not. The primary end point was the development of severe tricuspid regurgitation. Deaths were regarded as competing events. Secondary end points were death and heart failure. Inverse probability of treatment weighting was performed to reduce selection bias. Multivariable competing risk analysis was performed to determine the predictive factors of severe tricuspid regurgitation. RESULTS: There was no significant difference in early mortality rates between patients with and without tricuspid valve repair (P = .26). During a median follow-up of 71.6 (interquartile range: 25.3-124.2) months, the primary end point was detected in 7 of 419 patients (0.25%/patient-years) and 28 of 789 patients (0.57%/patient-years) with and without tricuspid valve repair, respectively (P = .04). There were no significant differences in the secondary end points. After baseline adjustment, the primary end point was not significantly different depending on the addition of tricuspid valve repair (hazard ratio, 0.64; 95% confidence interval, 0.23-1.77; P = .39). In multivariable analysis, only the omission of surgical atrial fibrillation ablation (hazard ratio, 4.52; 95% confidence interval, 2.07-9.87) was significantly associated with the development of severe tricuspid regurgitation. CONCLUSIONS: Tricuspid valve repair for mild tricuspid regurgitation in rheumatic mitral valve surgery provides no overt clinical benefit.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Insuficiência da Valva Tricúspide , Humanos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/complicações , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Fibrilação Atrial/cirurgia , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento , Estudos Retrospectivos , Implante de Prótese de Valva Cardíaca/efeitos adversos
8.
J Thorac Cardiovasc Surg ; 165(2): 622-629.e2, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-33867129

RESUMO

OBJECTIVE: Deterioration of the native aortic valve function by a late progression of rheumatic disease is not infrequent in patients who underwent rheumatic mitral valve surgery; however, this phenomenon has not been clearly quantified. METHODS: A total of 1155 consecutive patients (age 52.0 ± 12.9 years; 807 female) who underwent rheumatic mitral valve surgery without concomitant aortic valve surgery from 1997 to 2015 were enrolled. The primary end point was the composite of progression to severe aortic valve dysfunction or a requirement of subsequent aortic valve replacements during follow-up. To determine the risk factors of the primary outcome, we performed the generalized linear mixed model. RESULTS: The baseline severities of aortic valve were none to trivial in 880 patients (76.2%), mild in 256 patients (22.2%), and moderate in 19 patients (1.6%). The latest 1062 echocardiographic assessments (91.9%; median, 81.2 postoperative months; interquartile range, 37.3-132.1 months) demonstrated 26 cases (0.33%/patient-year) meeting the primary end point during follow-up. Cumulative incidence of the primary end point at 10 years was 0.4% ± 0.3% and 7.4% ± 2.5% depending on the presence of mild or greater aortic valve dysfunction at baseline (P < .01). In multivariable analyses, aortic valve peak pressure gradient (odds ratio, 1.14; 95% confidence interval, 1.10-1.20), aortic regurgitation degree (mild over none: odds ratio, 3.26; 95% confidence interval, 1.15-9.23), and time (odds ratio, 1.30; 95% confidence interval 1.19-1.41) were significantly associated with the occurrence of the primary end point. CONCLUSIONS: Progression of severe aortic valve dysfunction and the need for aortic valve replacement are uncommon in patients undergoing rheumatic mitral valve surgery. However, such events were relatively common among those with mild or greater aortic valve dysfunction at the time of mitral valve surgery.


Assuntos
Insuficiência da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cardiopatia Reumática , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Seguimentos , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Insuficiência da Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Cardiopatia Reumática/diagnóstico por imagem , Cardiopatia Reumática/cirurgia , Cardiopatia Reumática/complicações , Estudos Retrospectivos
9.
Heart Rhythm ; 20(1): 3-11, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36152976

RESUMO

BACKGROUND: The maze procedure is the dominant concomitant surgery performed with mitral valve (MV) surgery in patients with atrial fibrillation (AF). Most clinical recommendations regarding the maze procedure depend on the individual maze expert centers. OBJECTIVE: The purpose of this study was to evaluate the clinical benefits of the maze procedure during MV surgery in a national cohort. METHODS: Using the national health claims database established by the National Health Insurance Service of South Korea, data on subjects with AF who had undergone MV surgery from 2009 to 2017 were reviewed. The outcomes of interest were mortality; occurrence of ischemic or hemorrhagic stroke; hospitalization for bleeding events; and the composite of death, cerebrovascular accident, and major bleeding. Propensity score (PS) matching was performed for baseline adjustment. RESULTS: Among 9501 subjects, the maze procedure was performed in 5508 (58.0%). In the PS-matched cohort (3376 pairs), the risk of the composite event was significantly lower in the maze group (hazard ratio [HR] 0.799; 95% confidence interval [CI] 0.731-0.873) than in the nonmaze group. The superiority of the maze procedure was similar for individual clinical events, including death (HR 0.795; 95% CI 0.711-0.889); ischemic stroke (HR 0.788; 95% CI 0.67-0.926); and major bleeding (HR 0.749; 95% CI 0.627-0.895), but not for hemorrhagic stroke (HR 0.984; 95% CI 0.768-1.262). In subgroup analyses of the composite events, these benefits were consistent among subjects aged ≥70 years or <70 years, surgery type (replacement vs repair), MV pathologies, and subjects with CHA2DS2-VASc score ≥4 or <4. CONCLUSION: The addition of the maze procedure during MV surgery provided protective effects in the composite outcome of interest.


Assuntos
Fibrilação Atrial , Procedimentos Cirúrgicos Cardíacos , Ablação por Cateter , Acidente Vascular Cerebral Hemorrágico , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Valva Mitral/cirurgia , Acidente Vascular Cerebral Hemorrágico/complicações , Acidente Vascular Cerebral Hemorrágico/cirurgia , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ablação por Cateter/efeitos adversos
10.
JACC Case Rep ; 4(8): 470-472, 2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-35493799

RESUMO

Although rare, coronary arterial angiography carries a life-threatening risk of iatrogenic aortic dissection (AD). Given the paucity of data, an optimal treatment option for iatrogenic AD is a conundrum. In this report, we present our experience of spontaneous resolution of AD in a patient with catheter-driven iatrogenic AD during coronary arterial intervention. (Level of Difficulty: Advanced.).

11.
JTCVS Open ; 11: 37-48, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36172412

RESUMO

Objectives: To compare unilateral versus bilateral antegrade cerebral perfusion (ACP) techniques on cerebral protection during acute type A aortic dissection repair. Methods: Using an institutional database, we retrospectively reviewed patients who underwent acute type A aortic dissection repair with selective ACP techniques from October 2008 to December 2019. Primary end point was the detection of neurologic dysfunctions. The secondary end point was mortality. For baseline adjustment, the propensity score matching method was used. Multivariable logistic regression analysis was performed to determine the predictor of neurologic events. Results: Among 522 patients (aged 62.0 ± 14.9 years; 45.7% women), unilateral and bilateral ACP techniques were used in 357 (64.7%) and 165 (35.3%) patients, respectively. Transient (19.6% vs 21.2%; P = .65) and permanent (7.0% vs 10.3%; P = .70) neurologic dysfunction rates were not significantly different in patients with unilateral versus bilateral ACP, respectively. Observed mortality rate was higher in the patients with bilateral ACP (hazard ratio, 2.05; 95% CI, 1.33-3.14; P = .001). Propensity-score matching yielded 94 pairs of patients. In matched analysis, bilateral ACP did not significantly lower the risks for transient (odds ratio, 0.87; 95% CI, 0.42-1.81; P = .71) and permanent (odds ratio, 1.42; 95% CI, 0.55-3.85; P = .47) neurologic dysfunction or death (hazard ratio, 1.65; 95% CI, 0.87-3.15; P = .13). In the multivariable analysis, the ACP technique was not significantly associated with perioperative neurologic deficit. Conclusions: Despite additional supply, the patients undergoing bilateral ACP during acute type A aortic dissection repair did not have superior outcomes in neurologic and death events compared with the patients undergoing unilateral ACP.

12.
Korean Circ J ; 52(2): 136-146, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35043606

RESUMO

BACKGROUND AND OBJECTIVES: There still are controversies on which type between bovine pericardial and porcine valves is superior in the setting of aortic valve replacement (AVR). This study aims to compare clinical outcomes of AVR using between pericardial or porcine valves. METHODS: The study involved consecutive 636 patients underwent isolated AVR using stented bioprosthetic valves between January 2000 and May 2016. Of these, pericardial and porcine valves were implanted in 410 (pericardial group) and 226 patients (porcine group), respectively. Clinical outcomes including survival, structural valve deterioration (SVD) and trans-valvular pressure gradient were compared between the groups. To adjust for potential selection bias, inverse probability treatment weighting (IPTW) was conducted. RESULTS: The mean follow-up duration was 60.1±50.2 months. There were no significant differences in the rates of early mortality (3.1% vs. 3.1%; p=0.81) and SVD (0.3%/patient-year [PY] vs. 0.5%/PY; p=0.33) between groups. After adjustment using IPTW, however, landmark mortality analyses showed a significantly lower late (>8 years) mortality risk in pericardial group over porcine group (hazard ratio [HR], 0.61; 95% confidence interval, [CI] 0.41-0.90; p=0.01) while the risks of SVD were not significantly difference between groups (HR, 0.45; 95% CI, 0.12-1.70; p=0.24). Mean pressure gradient across prosthetic AV was lower in the Pericardial group than the Porcine group at both immediate postoperative point and latest follow-up (p values <0.001). CONCLUSIONS: In patients undergoing bioprosthetic surgical AVR, bovine pericardial valves showed superior results in terms of postoperative hemodynamic profiles and late survival rates over porcine valves.

13.
JACC Asia ; 1(2): 203-214, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36338168

RESUMO

Background: The lesion sets for surgical ablation of atrial fibrillation (AF) that provide optimal outcomes have remained controversial. Objectives: We evaluated the effects of left-atrial (LA) ablation of AF compared with bi-atrial (BA) ablation on the clinical and rhythm outcomes, and examined the predictors for AF recurrence and permanent pacing in consideration of ablation lesion sets. Methods: Between 2001 and 2018, 1,965 patients underwent surgical ablation during cardiac surgery at our institution. Among these, 796 and 1,169 patients underwent LA and BA ablation, respectively. The clinical outcomes were evaluated after propensity score adjustment, with death accounting for a competing event. The probability of AF recurrence was estimated with the generalized estimating equations model. Results: The patients with BA ablation had morbidities greater than those with LA ablation. The probability of AF recurrence at 1 and 5 years was 13.9% and 37.1% in patients with LA ablation, and 11.2% and 30.1% in those with BA ablation (hazard ratio [HR]: 1.24; 95% confidence interval [CI]: 0.96-1.61; P = 0.100). After adjustment, LA ablation was associated with a decreased risk of early death (<30 days) (odds ratio [OR]: 0.56; 95% CI: 0.31-0.96; P = 0.041) and new-onset dialysis (OR 0.47; 95% CI: 0.27-0.78; P = 0.003). However, the risk of overall mortality (HR: 1.03; 95% CI: 0.75-1.41; P = 0.878) and permanent pacing (HR: 0.68; 95% CI: 0.43-1.06; P = 0.091) was comparable between the 2 groups. Conclusions: The risk of AF recurrence and adverse events was comparable between the 2 ablation lesion sets. BA ablation was not related to an increased risk of permanent pacing.

14.
Ann Thorac Surg ; 109(3): e167-e169, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31400330

RESUMO

Gossypiboma-a surgical cotton matrix inadvertently left in the body cavity-is a rare postoperative complication, especially after cardiac surgery. We report a patient who presented with severe cardiac dysfunction caused by a huge pericardial gossypiboma that was detected 30 years after the previous cardiac surgery. This case delineates the serious medical consequences caused by pericardial gossypiboma and suggests considering gossypiboma as a differential diagnosis of a pericardial mass in patients with a history of cardiac surgery.


Assuntos
Corpos Estranhos/complicações , Cardiopatias/etiologia , Pericárdio , Corpos Estranhos/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Índice de Gravidade de Doença
15.
Heart ; 106(23): 1839-1846, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32376607

RESUMO

OBJECTIVES: This study aimed to evaluate the impact of left atrial appendage exclusion on clinical outcomes in patients with atrial fibrillation (AF) undergoing rheumatic mitral surgery. METHODS: We retrospectively reviewed 1226 consecutive patients with AF (54.5±11.6 years; 68.2% females) who underwent rheumatic mitral valve (MV) surgery from 1997 to 2016. The left atrial appendage was preserved in 836 (68.2%) and excluded in 390 (31.8%) patients. Surgical AF ablation was performed in 506 (60.5%) and 304 (77.9%) patients with preserved and excluded left atrial appendage, respectively. For baseline adjustment, propensity matching was used. RESULTS: During a median follow-up of 63.4 months (IQRs, 20-111 months), there were no significant intergroup differences in the risks of mortality (2.77% vs 3.03%/patient-years) and thromboembolic events (0.91% vs 1.02%/patient-years). In the 258 pairs of propensity-score matched patients, death (2.77% vs 3.03%/patient-years) and thromboembolism (1.36% vs 0.82%/patient-years) outcomes were comparable for both groups. In a subgroup undergoing ablation (n=810), there were no significant differences in the adjusted risks of death (HR, 0.67; 95% CI, 0.34 to 1.32) and thromboembolism (HR, 0.47; 95% CI, 0.18 to 1.26). In a subgroup not undergoing ablation (n=416), however, left atrial appendage preservation tended to have higher adjusted risks for death (HR, 2.24; 95% CI, 0.98 to 5.13) and thromboembolism (HR, 4.41; 95% CI, 0.97 to 20.1). CONCLUSIONS: Left atrial appendage preservation did not seem to have greater risks of adverse clinical events in patients with AF undergoing rheumatic MV surgery particularly when ablation procedure is combined.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial , Ablação por Cateter , Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Mitral , Complicações Pós-Operatórias , Cardiopatia Reumática , Tromboembolia , Adulto , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Estenose da Valva Mitral/complicações , Estenose da Valva Mitral/diagnóstico , Estenose da Valva Mitral/etiologia , Estenose da Valva Mitral/cirurgia , Avaliação de Processos e Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , República da Coreia/epidemiologia , Cardiopatia Reumática/diagnóstico , Cardiopatia Reumática/fisiopatologia , Cardiopatia Reumática/cirurgia , Dispositivo para Oclusão Septal , Tromboembolia/diagnóstico , Tromboembolia/etiologia , Tromboembolia/prevenção & controle
17.
JTCVS Tech ; 25: 19-23, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38899084
18.
J Thorac Cardiovasc Surg ; 158(4): 996-1004.e3, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-30578057

RESUMO

OBJECTIVES: The current guidelines do not consider chronic type A aortic dissection as one of the triggers for prophylactic aortic repair, and an aortic diameter of 55 mm is considered the threshold for surgery. METHODS: From the institutional database, we retrieved 82 patients who were diagnosed as having chronic type A aortic dissection but did not undergo immediate surgical repair from 1997 to 2016. The primary outcome was a composite of adverse aortic events defined as aortic rupture and sudden death. Conversion to elective surgery during follow-up was regarded as competing risk for adverse events. RESULTS: The median value of the maximal aortic diameter at baseline was 55.2 mm. During a median follow-up of 77.1 months, 19 adverse events occurred while 9 patients received elective aortic repair. On multivariable competing risk analyses, baseline aortic diameter and age emerged as significant and independent factors associated with aortic events. The estimated rates of aortic event within 5 years were 12.0%, 19.4%, and 29.7% for aortic diameters of 50, 60, and 70 mm, respectively, with escalating risk rates as age increased for the given aortic diameters. CONCLUSIONS: In unrepaired chronic type A aortic dissection, aortic events were not infrequent even for patients with an aortic diameter of less than 55 mm. This finding indicates that there may be a need to lower the surgical threshold for chronic type A aortic dissection.


Assuntos
Aorta/fisiopatologia , Aneurisma da Aorta Torácica/fisiopatologia , Dissecção Aórtica/fisiopatologia , Ruptura Aórtica/fisiopatologia , Idoso , Dissecção Aórtica/complicações , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/complicações , Aneurisma da Aorta Torácica/diagnóstico por imagem , Ruptura Aórtica/etiologia , Ruptura Aórtica/prevenção & controle , Implante de Prótese Vascular , Doença Crônica/terapia , Morte Súbita/etiologia , Morte Súbita/prevenção & controle , Progressão da Doença , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Medição de Risco , Tomografia Computadorizada por Raios X
19.
J Thorac Cardiovasc Surg ; 157(4): 1519-1528.e5, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30901792

RESUMO

OBJECTIVE: Efficacy of atrial fibrillation ablation in rheumatic mitral valve disease has been regarded inferior to that in nonrheumatic diseases. This study aimed to evaluate net clinical benefits by the addition of concomitant atrial fibrillation ablation in rheumatic mitral valve surgery. METHODS: Among 1229 consecutive patients with atrial fibrillation from 1997 to 2016 (54.4 ± 11.7 years; 68.2% were female), 812 (66.1%) received concomitant ablation of atrial fibrillation (ablation group), and 417 (33.9%) underwent valve surgery alone (no ablation group). Death and thromboembolic events were compared between these groups. Mortality was regarded as a competing risk to evaluate thromboembolic outcomes. To reduce selection bias, inverse probability of treatment weighting methods were performed. RESULTS: Freedom from atrial fibrillation occurrence at 5 years was 76.5% ± 1.8% and 5.3% ± 1.1% in the ablation and no ablation groups, respectively (P < .001). The ablation group had significantly lower risks for death (hazard ratio [HR], 0.69; 95% confidence interval [CI], 0.52-0.93) and thromboembolic events (HR, 0.49; 95% CI, 0.32-0.76) than the no ablation group. Time-varying Cox analysis revealed that the occurrence of stroke after surgery was significantly associated with death (HR, 3.97; 95% CI, 2.36-6.69). In subgroup analyses, the reduction in the composite risk of death and thromboembolic events was observed in all mechanical (n = 829; HR, 0.53; 95% CI, 0.39-0.73), bioprosthetic replacement (n = 239; HR, 0.67; 95% CI, 0.41-1.08), and repair (n = 161; HR, 0.17; 95% CI, 0.06-0.52) subgroups (P for interaction = .47). CONCLUSIONS: Surgical atrial fibrillation ablation during rheumatic mitral valve surgery was associated with a lower risk of long-term mortality and thromboembolic events. Therefore, atrial fibrillation ablation for rheumatic mitral valve disease may be a reasonable option.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Valva Mitral/cirurgia , Cardiopatia Reumática/cirurgia , Adulto , Idoso , Fibrilação Atrial/complicações , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Cardiopatia Reumática/complicações , Tromboembolia/etiologia
20.
Korean J Thorac Cardiovasc Surg ; 52(2): 61-69, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31089442

RESUMO

BACKGROUND: Scarce data have been reported on the efficacy of concomitant atrial fibrillation (AF) ablation in patients undergoing bioprosthetic valve replacement. METHODS: From 2001 and 2014, 146 consecutive patients (69.3±9.4 years, 84 females) who underwent bioprosthetic heart valve replacement concomitant with AF ablation were assessed. We evaluated long-term rhythm and valve-related outcomes. RESULTS: During 49.1 months of follow-up (interquartile range, 22.5-96.8 months), 7 in-hospital and 49 (6.7% per person-year) post-discharge deaths occurred. The thromboembolic event-free survival rate at 5 years was 79.2%±3.5%. The freedom from AF recurrence rate at 5 years was 59.8%±4.9%. Multivariate analysis showed that old age (hazard ratio [HR], 1.06; 95% confidence interval [CI], 1.02-1.11; p=0.002), previous cardiac operation (HR, 3.01; 95% CI, 1.22-7.43; p=0.02), and a large left atrial (LA) dimension (HR, 1.02; 95% CI, 1.00-1.05; p=0.045) were significantly associated with AF recurrence. CONCLUSION: The overall long-term clinical outcomes in these predominantly elderly patients undergoing AF ablation concomitantly with bioprosthetic valve replacement were satisfactory; however, AF recurrence was frequent. Older age, a history of prior cardiac surgery, and large LA size were associated with an increased risk of AF recurrence.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA