Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
Am J Dent ; 28(2): 95-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26087575

RESUMO

PURPOSE: To investigate the influence of CAD-CAM diamond bur deterioration on surface roughness (Ra) and maximum failure load (Lf) of Y-TZP-based ceramic (YZ) substructures (SB) veneered with a feldspathic porcelain. METHODS: Two sets of burs (B1 and B2) were used to fabricate 30 YZ SB each in a CAD/CAM system (Cerec InLab). The SB were identified (1-30) according to the milling sequence (MS). SEM images of the burs were recorded before milling, and after milling 15 and 30 SB. The SB Ra was measured. All SB were veneered, cemented onto a fiber reinforced epoxy resin die, and loaded to failure. Specimens from B1 group were cyclic fatigued (106 cycles) before loading to failure. Fractographic analysis was performed. Data were statistically analyzed using Student's t-test, Weibull analysis, Pearson's correlation and ANOVA (α= 0.05). RESULTS: The mean Ra value of B1 specimens was statistically greater than B2. Weibull modulus of B1 and B2 were statistically similar. The correlation between MS and Lf was not statistically significant for the groups. MS and Ra had significant correlation for both groups (B1: r= -0.514, P= 0.015; B2: r= -0.462, P= 0.03). Although the visual aspect (SEM) of the burs was similar after 30 millings, the mean Ra values were significantly different after 27 millings for B1 and 24 millings for B2.


Assuntos
Cerâmica/química , Desenho Assistido por Computador/instrumentação , Materiais Dentários/química , Restauração Dentária Permanente , Diamante/química , Ítrio/química , Zircônio/química , Silicatos de Alumínio/química , Cimentação/métodos , Porcelana Dentária/química , Facetas Dentárias , Módulo de Elasticidade , Resinas Epóxi/química , Vidro/química , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Compostos de Potássio/química , Estresse Mecânico , Propriedades de Superfície
2.
J Prosthodont ; 23(6): 462-6, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24597786

RESUMO

PURPOSE: This study aimed to investigate the influence of ceramic thickness and shade on the Knoop hardness and dynamic elastic modulus of a dual-cured resin cement. MATERIALS AND METHODS: Six ceramic shades (Bleaching, A1, A2, A3, A3.5, B3) and two ceramic thicknesses (1 mm, 3 mm) were evaluated. Disk specimens (diameter: 7 mm; thickness: 2 mm) of the resin cement were light cured under a ceramic block. Light-cured specimens without the ceramic block at distances of 1 and 3 mm were also produced. The Knoop hardness number (KHN), density, and dynamic Young's moduli were determined. Statistical analysis was conducted using ANOVA and a Tukey B rank order test (p = 0.05). RESULTS: The bleaching 1-mm-thick group exhibited significantly higher dynamic Young's modulus. Lower dynamic Young's moduli were observed for the 3-mm-thick ceramic groups compared to bleaching 3-mm-thick group, and no difference was found among the other 3-mm groups. For the KHN, when A3.5 3-mm-thick was used, the KHN was significantly lower than bleaching and A1 1-mm-thick ceramic; however, no difference was exhibited between the thicknesses of the same shade. CONCLUSIONS: The dual-cured resin cement studied irradiated through the 1-mm-thick ceramic with the lightest shade (bleaching ceramic) exhibited a better elastic modulus, and there was no effect in KHN of the resin cement when light cured under different ceramic shades and thicknesses (1 and 3 mm), except when the A3.5 3-mm-thick ceramic was used. CLINICAL SIGNIFICANCE: Variolink II irradiated through ceramic with the lowest chroma exhibited the highest elastic modulus; therefore, the light activation method might not be the same for all clinical situations.


Assuntos
Cerâmica/química , Porcelana Dentária/química , Cimentos de Resina/química , Cor , Módulo de Elasticidade , Dureza , Humanos , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Polimerização , Autocura de Resinas Dentárias , Estresse Mecânico , Propriedades de Superfície
3.
J Adhes Dent ; 15(5): 461-6, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23593644

RESUMO

PURPOSE: To evaluate the microtensile bond strength (MTBS) of ceramic cemented to dentin varying the resin cement and ceramic shades. MATERIALS AND METHODS: Two VITA VM7 ceramic shades (Base Dentine 0M1 and Base Dentine 5M3) were used. A spectrophotometer was used to determine the percentage translucency of ceramic (thickness: 2.5 mm). For the MTBS test, 80 molar dentin surfaces were etched and an adhesive was applied. Forty blocks (7.2 x 7.2 x 2.5 mm) of each ceramic shade were produced and the ceramic surface was etched (10% hydrofluoric acid) for 60 s, followed by the application of silane and resin cement (A3 yellow and transparent). The blocks were cemented to dentin using either A3 or transparent cement. Specimens were photoactivated for 20 s or 40 s, stored in distilled water (37°C/24 h), and sectioned. Eight experimental groups were obtained (n = 10). Specimens were tested for MTSB using a universal testing machine. Data were statistically analyzed using ANOVA and Tukey's post-hoc tests (α <= 0.05). RESULTS: The percentage translucency of 0M1 and 5M3 ceramics were 10.06 (± 0.25)% and 1.34 (± 0.02)%, respectively. The lowest MTBS was observed for the ceramic shade 5M3. For the 0M1 ceramic, the A3 yellow cement that was photocured for 20 s exhibited the lowest MTBS, while the transparent cement that was photocured for 40 s presented the highest MTBS. CONCLUSIONS: For the 2.5-mm-thick 5M3 ceramic restorations, the MTBS of ceramic cemented to dentin significantly increased. The dual-curing cement Variolink II photocured for 40 s is not recommended for cementing the Base Dentine 5M3 feldspathic ceramic to dentin.


Assuntos
Colagem Dentária , Porcelana Dentária/química , Dentina/anatomia & histologia , Cimentos de Resina/química , Condicionamento Ácido do Dente/métodos , Silicatos de Alumínio/química , Cimentação/métodos , Cerâmica/química , Cor , Cimentos Dentários/química , Análise do Estresse Dentário/instrumentação , Humanos , Ácido Fluorídrico/química , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Ácidos Fosfóricos/química , Compostos de Potássio/química , Silanos/química , Espectrofotometria , Estresse Mecânico , Propriedades de Superfície , Temperatura , Resistência à Tração , Fatores de Tempo , Água/química
4.
J Adhes Dent ; 15(6): 569-74, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24278961

RESUMO

PURPOSE: To evaluate the influence of heat treatment (HT) procedures of a pre-hydrolyzed silane on bond strength of resin cement to a feldspathic ceramic. MATERIALS AND METHODS: Ceramic and composite blocks (N = 30) were divided into six groups (n = 5) and subjected to the following conditioning procedures: G1: 9.6% hydrofluoric acid (HF) for 20 s + silane (RelyX Ceramic Primer, 3M ESPE) + resin cement (Panavia F2.0, Kuraray) (control); G2: HF (20 s) + silane + heat treatment in furnace (HTF) (100°C, 2 min) + resin cement; G3: silane + HTF + resin cement; G4- HF (20 s) + silane + heat treatment with hot air (HTA) (50 ± 5°C for 1 min) + resin cement; G5: silane + HTA + resin cement; G6: silane + resin cement. The microtensile bond strength (MTBS) test was performed using a universal testing machine (1 mm/min). After debonding, the substrate and adherent surfaces were analyzed using a stereomicroscope and SEM to categorize the failure types. The data were statistically evaluated using one-way ANOVA and Tukey's test (5%). RESULTS: The control group (G1) showed no pre-test failures and presented significantly higher mean MTBS (16.01 ± 1.12 MPa) than did other groups (2.63 ± 1.05 to 12.55 ± 1.52 MPa) (p = 0.0001). In the groups where HF was not used, HTF (G3: 12.55 ± 1.52 MPa) showed significantly higher MTBS than did HTA (G5: 2.63 ± 1.05 MPa) (p < 0.05). All failure types were mixed, ie, adhesive between the resin cement and ceramic accompanied by cohesive failure in the cement. CONCLUSION: Heat treatment procedures for the pre-hydrolyzed silane either in a furnace or with the application of hot air cannot replace the use of HF gel for the adhesion of resin cement to feldspathic ceramic. Yet when mean bond strengths and incidence of pre-test failures are considered, furnace heat treatment delivered the second best results after the control group, being considerably better than hot air application.


Assuntos
Condicionamento Ácido do Dente/métodos , Silicatos de Alumínio/química , Colagem Dentária , Corrosão Dentária/métodos , Porcelana Dentária/química , Ácido Fluorídrico/química , Compostos de Potássio/química , Cimentos de Resina/química , Silanos/química , Adesividade , Resinas Compostas/química , Análise do Estresse Dentário/instrumentação , Temperatura Alta , Humanos , Hidrólise , Teste de Materiais , Microscopia Eletrônica de Varredura , Estresse Mecânico , Propriedades de Superfície , Fatores de Tempo
5.
J Contemp Dent Pract ; 11(1): E065-72, 2010 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-20098968

RESUMO

AIM: The aim of the study was to assess the accuracy of a new intraoral paralleling device for creating proximal guiding planes for removable partial dental prostheses. METHODS AND MATERIALS: Thirty gypsum casts were divided into two groups in which the proximal surfaces of selected teeth were prepared using either a surveying device (Group 1) or the new ParalAB paralleling device (Group 2). In each cast guiding planes were prepared on the distal surface of the maxillary left canine (A), on the mesial and distal surfaces of the maxillary left second molar (B and C), and on the distal surface of the maxillary right canine (D). Each prepared surface formed an angle related to the occlusal plane that was measured five times and averaged by one operator using a tridimensional coordinate machine. RESULTS: The mean guiding plane angles (+/- standard deviation) for the prepared surfaces were A=91.82 degrees (+/-0.48 degrees ), B=90.47 degrees (+/-0.47 degrees ), C=90.21 degrees (+/-0.76 degrees ), and D=90.50 degrees (+/-0.73 degrees ) for the dental surveyor (Group 1) and A=92.18 degrees (+/-0.87 degrees ), B=90.90 degrees (+/-0.85 degrees ), C=90.07 degrees (+/-0.92 degrees ), and D=90.66 degrees (+/-0.76 degrees ) for the ParalAB paralleling device (Group 2). A two-way ANOVA, Tukey's, and Levène's tests (at p<0.05) revealed statistically significant differences among surfaces prepared by both groups and that one surface (A in Group 2) was more parallel to the path of insertion than the other surfaces. CONCLUSIONS: The ParalAB device was able to prepare parallel surfaces and despite significant difference between groups, the ParalAB presented a small deviation from absolute parallelism and can be considered a valid method to transfer guide plans in the fabrication of removable partial dentures. CLINICAL SIGNIFICANCE: The preparation of suitable guiding planes on abutment teeth during the fabrication of removable partial dentures is dependent on the ability of the operator and requires considerable chair time. When multiple teeth are involved, achieving parallelism between abutment surfaces can be technically challenging, especially in posterior regions of the mouth. The ParalAB prototype intraoral paralleling device can aid the clinician during the preparation of accurate guiding planes with a minimum degree of occlusal divergence.


Assuntos
Cefalometria/instrumentação , Equipamentos Odontológicos , Oclusão Dentária , Planejamento de Dentadura/instrumentação , Prótese Parcial Removível , Desenho Assistido por Computador , Dente Suporte , Humanos , Modelos Dentários , Projetos Piloto , Ajuste de Prótese/instrumentação , Preparo Prostodôntico do Dente
6.
Eur J Prosthodont Restor Dent ; 18(3): 107-10, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21077418

RESUMO

The objective of this study was to evaluate the flexural strength of denture base resin reinforced with glass fibers and with a laboratorial composite resin. Group G1 was formed with specimens made of acrylic resin. Group G2 was formed with the same acrylic resin but reinforced with a glass-fiber system, and G3 was reinforced with the composite resin. A flexural strength test was performed in all groups (n=10). The mean value for the G1 was 86.70 MPa +/- 6.48, for G2 it was 86.60 MPa +/- 15.01 and for G3 it was 108.90 + 11.03. The addition of glass fiber did not increase the flexural strength however the use of a resin-based composite produced significant reinforcement.


Assuntos
Resinas Acrílicas/química , Análise do Estresse Dentário , Bases de Dentadura , Análise de Variância , Resinas Compostas , Vidro , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Maleabilidade , Estatísticas não Paramétricas
7.
Dent Mater ; 36(5): e149-e157, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32061444

RESUMO

OBJECTIVE: To evaluate the composition, flexural strength and fatigue behaviour of lithium disilicate ceramic (LD) after repeated firings and different staining techniques. METHODS: LD discs were fabricated and divided according to number of firing cycles and staining technique: CO - control, discs were crystallized (850°C/10min); SC - single-step characterization - crystallization and staining (applied with a thin brush) were performed in a single step with one firing cycle (850°C/10min); and DC - double-step characterization - crystallization firing cycle was performed first (850°C/10min), followed by staining firing cycle (770°C/90s). Specimens were fired two, four or six times (one crystallization firing cycle and one, three or five staining firing cycles), resulting into 9 groups (n=30): COII, COIV, COVI, SCII, SCIV, SCVI, DCII, DCIV and DCVI. The composition of the specimens was investigated (EDS, XRD, Raman spectroscopy), and the biaxial flexural strength (n=10) and staircase tests (n=20, 5×104 cycles, 5Hz) were performed. Data were subjected to one-way ANOVA and Tukey's test (α=0.05). RESULTS: EDS and XRD revealed amorphous content for stained groups. Biaxial flexural strength was not affected by repeated firings in any group, but stained groups presented lower flexural strength than control groups (p=0.001). The fatigue limit results decreased in all groups compared to flexural strength. SC groups showed similar (SCII and SCIV) or even higher fatigue limits (SCVI) than the control groups, and DC showed the lowest fatigue limit values. SEM and Raman suggested that the interfaces between staining and the LD showed only an overlap for the DC groups, whereas for the SC it was suggested an interaction between the stain and the LD. SIGNIFICANCE: Repeated firings did not result in decreased lithium disilicate flexural strength.Staining affected flexural strength and also resulted in increased amorphous content in the characterized specimens. Single-step staining resulted in the highest fatigue limit.


Assuntos
Cerâmica , Porcelana Dentária , Teste de Materiais , Coloração e Rotulagem , Propriedades de Superfície
8.
J Adhes Dent ; 10(6): 455-60, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19189676

RESUMO

PURPOSE: To assess the effect of adhesive application and aging on the bond durability of resin cement to etched and silanized feldspathic ceramic. MATERIALS AND METHODS: Twenty blocks (6.4 x 6.4 x 4.8 mm) of feldspathic ceramic (Vita VM7) were produced. The ceramic surfaces were conditioned with 10% hydrofluoric acid gel for 60 s and silanized. They were then randomly divided into two groups. While half of the group received no adhesive, in the other half, a layer of adhesive (Scotchbond Multi-Purpose Plus) was applied. Each ceramic block was then placed in its silicone mold with the treated surface exposed. The dual-cured resin cement (Variolink II) was injected into the mold over the treated surface and polymerized. Specimens were sectioned to achieve nontrimmed bar specimens (approximately 12 sticks/block) that were randomly divided into 2 groups: a) non-aged--microtensile bond test immediately after sectioning; b) aged-thermocycling (TC) 12,000 times, 5 degrees C to 55 degrees C, and water storage (50 days). The microtensile bond strength test was performed in a universal testing machine (crosshead speed: 1 mm/min). The failure types were examined using an optical light microscope and SEM. Bond strength results were analyzed using two-way ANOVA and Tukey's test (alpha = 0.05). RESULTS: The adhesive application affected the bond strength results significantly (p = 0.0001) (without adhesive > with adhesive). While aging conditions did not reduce the bond strength in the groups that received no adhesive (20 +/- 5.3 MPa non-aged and 21.5 +/- 5.6 aged) (p = 0.1698), it significantly affected the bond strength results of the group with adhesive application (18 +/- 4.4 MPa to 14.4 +/- 4.7 MPa) (p < 0.001). All groups showed mainly mixed type of failures between the ceramic and the resin cement (81% to 100%). The group in which no adhesive was applied presented a higher incidence of cohesive failure of ceramic after aging (18%) than those of the other groups. CONCLUSION: The use of adhesive did not improve resin cement adhesion to the etched and silanized feldspathic ceramic after long-term thermocycling and water storage.


Assuntos
Condicionamento Ácido do Dente/métodos , Silicatos de Alumínio/química , Colagem Dentária , Porcelana Dentária/química , Compostos de Potássio/química , Cimentos de Resina/química , Silanos/química , Análise do Estresse Dentário/instrumentação , Humanos , Ácido Fluorídrico/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Estresse Mecânico , Propriedades de Superfície , Temperatura , Resistência à Tração , Fatores de Tempo , Água/química
9.
J Prosthodont ; 17(8): 627-33, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-18761581

RESUMO

PURPOSE: The aim of this study was to evaluate the effectiveness of disinfectant solutions (1% sodium hypochlorite, 2% chlorhexidine digluconate, 2% glutaraldehyde, 100% vinegar, tabs of sodium perborate-based denture cleanser, and 3.8% sodium perborate) in the disinfection of acrylic resin specimens (n = 10/group) contaminated in vitro by Candida albicans, Streptococcus mutans, S. aureus, Escherichia coli, or Bacillus subtilis as measured by residual colony-forming unit (CFU). In a separate experiment, acrylic resin was treated with disinfectants to monitor potential effects on surface roughness, Ra (microm), which might facilitate microbial adherence. MATERIALS AND METHODS: Three hundred fifty acrylic resin specimens contaminated in vitro with 1 x 10(6) cells/ml suspensions of standard strains of the cited microorganisms were immersed in the disinfectants for 10 minutes; the control group was not submitted to any disinfection process. Final counts of microorganisms per ml were performed by plating method for the evaluation of microbial level reduction. Results were compared statistically by ANOVA and Tukey's test (p< or = 0.05). In a parallel study aiming to evaluate the effect of the tested disinfectant on resin surface, 60 specimens were analyzed in a digital rugosimeter before and after ten cycles of 10-minute immersion in the disinfectants. Measurements of superficial roughness, Ra (mum), were compared statistically by paired t-test (p< or = 0.05). RESULTS: The results showed that 1% sodium hypochlorite, 2% glutaraldehyde, and 2% chlorhexidine digluconate were most effective against the analyzed microorganisms, followed by 100% vinegar, 3.8% sodium perborate, and tabs of sodium perborate-based denture cleanser. Superficial roughness of the specimens was higher after disinfection cycles with 3.8% sodium perborate (p= 0.03) and lower after the cycles with 2% chlorhexidine digluconate (p= 0.04). CONCLUSION: Within the limits of this experiment, it could be concluded that 1% sodium hypochlorite, 2% glutaraldehyde, 2% chlorhexidine, 100% vinegar, and 3.8% sodium perborate are valid alternatives for the disinfection of acrylic resin.


Assuntos
Resinas Acrílicas/química , Bactérias/efeitos dos fármacos , Desinfetantes de Equipamento Odontológico/farmacologia , Materiais Dentários/química , Ácido Acético/química , Ácido Acético/farmacologia , Bacillus subtilis/efeitos dos fármacos , Aderência Bacteriana/efeitos dos fármacos , Boratos/química , Boratos/farmacologia , Candida albicans/efeitos dos fármacos , Clorexidina/análogos & derivados , Clorexidina/química , Clorexidina/farmacologia , Contagem de Colônia Microbiana , Desinfetantes de Equipamento Odontológico/química , Higienizadores de Dentadura/química , Higienizadores de Dentadura/farmacologia , Escherichia coli/efeitos dos fármacos , Glutaral/química , Glutaral/farmacologia , Humanos , Teste de Materiais , Hipoclorito de Sódio/química , Hipoclorito de Sódio/farmacologia , Staphylococcus aureus/efeitos dos fármacos , Streptococcus mutans/efeitos dos fármacos , Propriedades de Superfície , Fatores de Tempo
10.
J Mech Behav Biomed Mater ; 81: 173-177, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29525667

RESUMO

The aim of this study was compare the effect of two in vitro ageing protocols to intraoral aging on the flexural strength of a lithium disilicate (LD) ceramic bars with clamped ends. After polishing and crystallization, the both ends of the bars were cemented to a metallic device and subjected to mechanical cycling, thermomechanical cycling, or intraoral ageing. Ten volunteers used an intraoral device - similar to an occlusal splint with a balanced contact condition on the occlusal surface of the ceramic bar - during 8 h night time / 30 days. Both in vitro and intraoral ageing decreased the flexural residual strength of LD, with the lowest values obtained after intraoral ageing. Thus, the in vitro ageing protocols tested in this study revealed to be less deleterious than intraoral ageing of LD.


Assuntos
Porcelana Dentária , Resistência à Flexão , Teste de Materiais , Cerâmica , Fatores de Tempo
11.
Braz Oral Res ; 32: e34, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29742232

RESUMO

To evaluate the effect of different surface treatments on the marginal misfit and retentive strength between Y-TZP crowns and an epoxy resin. Forty (40) epoxy resin (G10) abutments (height: 5mm, conicity: 60, finish line: large chamfer) with equal dimensions were milled and included in polyurethane to simulate the periodontal ligament. Next, 40 Y-TZP crowns (thickness: 1mm) were milled (Cerec in Lab) and randomly divided into four groups (n=10) according to the surface treatment: GS(glaze spray), GP(glaze powder/liquid), P(zirconia primer) and RS(tribochemical silica coating). The conditioned surfaces were cemented with dual self-adhesive cement, light cured and submitted to thermomechanical cycling (2x106, 100N, 4Hz, 5°/55°C). Marginal misfit was analyzed by a stereomicroscope and SEM. Retentive strength test was performed (1mm/min) until crown debonding. Glaze layer thickness was also performed to GS and GP groups. Marginal misfit data were analyzed by Kruskal Wallis and Dunn tests; one-way ANOVA and Tukey (5%) analyzed the tensile strength data. The marginal misfit of the GS (48.6±19.9µm) and GP (65.4±42.5µm) were statistically lower than the RS (96±62.9µm) and P (156±113.3µm) (p=0.001). The retentive strength of the GP (470.5±104.1N) and GS (416.8±170.2N) were similar to the P (342.1±109.7N), but statistically higher than those of the RS (208.9±110N). The GS and GP glaze layer was 11.64µm and 9.73µm respectively. Thus, glaze application promoted lower marginal discrepancy and higher retentive strength values than conventional techniques.


Assuntos
Coroas , Colagem Dentária/métodos , Adaptação Marginal Dentária , Resinas Epóxi/química , Vidro/química , Ítrio/química , Zircônio/química , Análise de Variância , Desenho Assistido por Computador , Falha de Restauração Dentária , Teste de Materiais , Microscopia Eletrônica de Varredura , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Propriedades de Superfície , Resistência à Tração
12.
Braz. dent. sci ; 26(4): 1-8, 2023. ilus, tab
Artigo em Inglês | BBO, LILACS | ID: biblio-1512140

RESUMO

Objective: To evaluate the biaxial flexural strength (BFS) of lithium disilicate (L), cemented on different substrates (epoxy resin - E and metal - M) with dual-cure resin cement (Rc) and zinc phosphate cement (Zc), not aged, thermally aged (TC) or thermo-mechanical aged (TC/MC). Material and Methods: Disks of L, E, and M were fabricated, and the cementation was performed according to the following groups: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Ten samples from each described group were tested in BFS, ten more samples were subjected to TC (1×104 cycles between 5 ºC and 55 ºC water), and the last 10 samples were subjected to TC/MC (MC: 1.2×106 cycles, 50 N, 3.8 Hz). The BFS test was performed and scanning electron microscopy (SEM) was performed to evaluate the failure mode. The effect of the cementation strategy (cement/substrate) was compared in each aging method and the effect of the aging method was evaluated for each cementation strategy by one-way ANOVA and Tukey post-hoc test (α=0.05). Results: The strength values were highest to M (237.8 ~ 463.9 MPa), in comparison to the E (41.03 ~ 66.76 MPa), despite aging and luting agent. Flexural strength data decreased after TC and TC/MC in groups cemented with Zc, but was stable when cemented with Rc. SEM analysis indicated that failure origins were located at the tensile surface of the L. Conclusion: Lithium disilicate discs cemented to the metallic substrate presented the highest biaxial flexural strength. The cementation with dual-cure resin cement did not decrease BFS after aging (AU)


Objetivo: Avaliar a resistência à flexão biaxial (BFS) do dissilicato de lítio (L), cimentado sobre diferentes substratos (resina epóxi - E e metal - M) com cimento resinoso dual (Rc) e cimento de fosfato de zinco (Zc), não envelhecido, submetido ao envelhecido térmico (TC) ou ao envelhecido térmico-mecânico (TC/MC). Material e Métodos: Foram confeccionados discos de L, E e M, e a cimentação foi realizada de acordo com os seguintes grupos: ERc (L+E+Rc); MRc (L+M+Rc); MZc (L+M+Zc); EZc (L+E+Zc). Dez amostras de cada grupo descrito foram testadas em BFS, mais dez amostras foram submetidas à TC (1×104 ciclos de imersão em água entre 5 ºC e 55 ºC), e as últimas 10 amostras foram submetidas à TC/MC (MC: 1.2 ×106 ciclos, 50 N, 3.8 Hz). Foram realizados os testes de BFS e a microscopia eletrônica de varredura (MEV) para avaliar o modo de falha. O efeito da estratégia de cimentação (cimento/substrato) foi comparado em cada método de envelhecimento e o efeito do método de envelhecimento foi avaliado para cada estratégia de cimentação por ANOVA a um fator e teste post-hoc de Tukey (α=0,05). Resultados: Os valores de resistência foram maiores para M (237.8 ~ 463.9 MPa), em comparação com E (41.03 ~ 66.76 MPa), independentemente do envelhecimento e do agente cimentante utilizado. Os dados de resistência à flexão diminuíram após TC e TC/MC nos grupos cimentados com Zc, mas se mantiveram estáveis quando cimentados com Rc. A análise MEV indicou que a origem das falhas estava localizada na superfície de tração do L. Conclusão: Os discos de dissilicato de lítio cimentados ao substrato metálico apresentaram maior resistência à flexão biaxial. A cimentação com cimento resinoso dual não diminuiu o BFS após o envelhecimento (AU)


Assuntos
Envelhecimento , Cimentação , Resistência à Flexão
13.
Biosci. j. (Online) ; 39: e39051, 2023.
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1555445

RESUMO

Alternative surface treatments have been proposed for the cementation of lithium disilicate ceramics aiming to improve adhesive and flexural strength under fatigue. This study aimed to evaluate the slow crack growth (SCG) parameters of the lithium disilicate ceramic after hydrofluoric acid (HF) etching or air abrasion (AB) as surface treatments. Ceramic discs were treated with HF (5%, 20 s) or AB (30 µm silica-modified alumina particles, 2.8 bar, 10 mm distance, 15 s), and received a layer of resin cement. The surface roughness after surface treatment was evaluated (n = 5). Samples were tested in a piston-on-three-ball assembly to evaluate the flexural strength (n = 20), inert strength (n = 25), and to determine SCG parameters n and D (n = 35). The highest roughness (p < 0.01) was observed in the AB group, with the highest reliability according to the Weibull analysis, but the lowest SCG susceptibility. Flexural (p = 0.03) and inert strength (p < 0.01) were the greatest in the HF group. Despite exhibiting lower strength than 5% HF, air abrasion may be an alternative for the surface treatment of lithium disilicate surfaces, indicating the best prognosis over time.

14.
J Adhes Dent ; 9(5): 443-7, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18297825

RESUMO

PURPOSE: This study evaluated the effect of surface conditioning methods and thermocycling on the bond strength between a resin composite and an indirect composite system in order to test the repair bond strength. MATERIALS AND METHODS: Eighteen blocks (5 x 5 x 4 mm) of indirect resin composite (Sinfony) were fabricated according to the manufacturer's instructions. The specimens were randomly assigned to one of the following two treatment conditions (9 blocks per treatment): (1) 10% hydrofluoric acid (HF) for 90s (Dentsply) + silanization, (2) silica coating with 30-im SiOx particles (CoJet) + silanization. After surface conditioning, the bonding agent was applied (Adper Single Bond) and light polymerized. The composite resin (W3D Master) was condensed and polymerized incrementally to form a block. Following storage in distilled water at 37 degrees C for 24 h, the indirect composite/resin blocks were sectioned in two axes (x and y) with a diamond disk under coolant irrigation to obtain nontrimmed specimens (sticks) with approximately 0.6 mm2 of bonding area. Twelve specimens were obtained per block (N=216, n=108 sticks). The specimens from each repaired block were again randomly divided into 2 groups and tested either after storage in water for 24 h or thermocycling (6000 cycles, 5 degrees C to 55 degrees C). The microtensile bond strength test was performed in a universal testing machine (crosshead speed: 1 mm/min). The mean bond strengths of the specimens of each block were statistically analyzed using two-way ANOVA (alpha = 0.05). RESULTS: Both surface conditioning (p = 0.0001) and storage conditions (p = 0.0001) had a significant effect on the results. After 24 h water storage, silica coating and silanization (method 2) showed significantly higher bond strength results (46.4 +/- 13.8 MPa) than that of hydrofluoric acid etching and silanization (method 1) (35.8 +/- 9.7 MPa) (p < 0.001). After thermocycling, no significant difference was found between the mean bond strengths obtained with method 1 (34.1 +/- 8.9 MPa) and method 2 (31.9 +/- 7.9 MPa) (p > 0.05). CONCLUSION: Although after 24 h of testing, silica coating and silanization performed significantly better in resin-resin repair bond strength, both HF acid gel and silica coating followed by silanization revealed comparable bond strength results after thermocycling for 6000 times.


Assuntos
Resinas Compostas , Colagem Dentária , Corrosão Dentária/métodos , Reparação em Prótese Dentária , Análise de Variância , Análise do Estresse Dentário , Armazenamento de Medicamentos , Ácido Fluorídrico , Distribuição Aleatória , Silanos , Dióxido de Silício , Propriedades de Superfície , Resistência à Tração
15.
Braz Dent J ; 26(1): 44-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25672383

RESUMO

This study evaluated the influence of different forms of heat treatment on a pre-hydrolyzed silane to improve the adhesion of phosphate monomer-based (MDP) resin cement to glass ceramic. Resin and feldspathic ceramic blocks (n=48, n=6 for bond test, n=2 for microscopy) were randomly divided into 6 groups and subject to surface treatments: G1: Hydrofluoric acid (HF) 9.6% for 20 s + Silane + MDP resin cement (Panavia F); G2: HF 9.6% for 20 s + Silane + Heat Treatment (oven) + Panavia F; G3: Silane + Heat Treatment (oven) + Panavia F; G4: HF 9.6% for 20 s + Silane + Heat Treatment (hot air) + Panavia F; G5: Silane + Heat Treatment (hot air) + Panavia F; G6: Silane + Panavia F. Microtensile bond strength (MTBS) test was performed using a universal testing machine (1 mm/min). After debonding, the substrate and adherent surfaces were analyzed using stereomicroscope and scanning electron microscope (SEM) to categorize the failure types. Data were analyzed statistically using two-way test ANOVA and Tukey's test (=0.05). Heat treatment of the silane containing MDP, with prior etching with HF (G2: 13.15 ± 0.89a; G4: 12.58 ± 1.03a) presented significantly higher bond strength values than the control group (G1: 9.16 ± 0.64b). The groups without prior etching (G3: 10.47 ± 0.70b; G5: 9.47 ± 0.32b) showed statistically similar bond strength values between them and the control group (G1). The silane application without prior etching and heat treatment resulted in the lowest mean bond strength (G6: 8.05 ± 0.37c). SEM analysis showed predominantly adhesive failures and EDS analysis showed common elements of spectra (Si, Na, Al, K, O, C) characterizing the microstructure of the glass-ceramic studied. Heat treatment of the pre-hydrolyzed silane containing MDP in an oven at 100 °C for 2 min or with hot air application at 50 ± 5 ºC for 1 min, was effective in increasing the bond strength values between the ceramic and resin cement containing MDP.


Assuntos
Condicionamento Ácido do Dente , Cerâmica/química , Colagem Dentária/métodos , Temperatura Alta , Cimentos de Resina/química , Silanos/química , Ácido Fluorídrico/química , Teste de Materiais , Propriedades de Superfície , Resistência à Tração
16.
J Appl Biomater Funct Mater ; 13(3): e266-73, 2015 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-26391866

RESUMO

PURPOSE: This study evaluated the effect of air abrasion and polishing regimens on the flexural strength of yttrium stabilized polycrystalline tetragonal zirconia (Y-TZP). METHODS: From Y-TZP blocks (InCeram 2000 YZ Cubes; Vita Zahnfabrik, Bad Säckingen, Germany) 120 bars (25 mm × 4 mm × 1.2 mm) were obtained according to ISO 6872:2008 and randomly divided into 4 groups: Group C: (control) without surface treatment (n = 30); Group APA: Air abrasion with aluminum oxide (44 µm) (n = 30); Group SC: Silica-coating (CoJet, 30 µm) (n = 30); Group FD: Fine diamond bur (n = 30). Subsequently, all specimens were subjected to 4-point bending test (in distilled water at 37 °C) in a universal testing machine (EMIC DL 1000; São José dos Pinhais, Paraná, Brazil); cross-head speed: 0.5 mm/min). The characteristic strength (σ0) of each specimen was obtained from the flexural strength test and evaluated using Weibull analysis. X-ray diffraction analysis was utilized to quantity the monoclinic phase. The surface topography of specimens was analyzed using 3D optical profilometer and scanning electron microscopy (SEM) after surface conditioning methods. The flexural strength data (σ4p) were statistically analyzed by 1-way ANOVA, Tukey test (α = 0.05) and Weibull (m = modulus, σ0 = characteristic strength) were calculated. RESULTS: The mean ± standard deviations (MPa) of the groups were as follows: C: 1196.2 ± 284.2a; APA: 1369.7 ± 272.3a; SC: 1207.1 ± 229.7a and FD: 874.4 ± 365.4b. The values (m) and (σ0) were as follows: C: 4.5 and 1308.12; APA: 5.9 and 1477.88; SC: 6.0 and 1300.28; and FD: 2.6 and 985.901, respectively. CONCLUSIONS: Air particle abrasion with neither silica nor alumina showed significant difference compared to the control group but grinding with fine diamond bur impaired the flexural strength of the zirconia tested.


Assuntos
Materiais Dentários/química , Polimento Dentário , Zircônio/química , Diamante , Resistência ao Cisalhamento , Propriedades de Superfície , Ítrio/química
17.
Arq. odontol ; 56: 1-8, jan.-dez. 2020. ilus, tab
Artigo em Inglês | LILACS, BBO | ID: biblio-1097768

RESUMO

Aim: To evaluate the influence of lengths and different luting agents on the bond strength of fiberglass posts' adhesion to dentin.Methods: Sixty single-root bovine teeth were endodontically treated and included in polyether and acrilyc resin to simulate a periodontal ligament. These were divided into 6 groups according to the post lengths (6, 10 or 14 mm) and luting agents (self-adhesive dual resin cement ­ U; or etch-and-rinse dual resin cement ­ A): U6, U10, U14, A6, A19, and A14. All fiberglass posts were cemented according to manufacturer instructions. After this, mechanical aging was performed (1.2x106 cycles; 4 Hz, 90 N). The push-out specimens were then conducted (2.0 ± 0.1 mm), with the test executed in a universal machine (10 kgf at 0.5 mm/min). Data obtained were submitted to the Kruskal-Wallis and Dunn's test. Results: No statistically significant difference was observed in bond strength between the groups due to the type of luting agent (p > 0.05). However, the isolated post-length factor showed significantly different results for the U groups (p < 0.05). The U10 group showed similar union values to U6 but statistically inferior to U14. Conclusion: bond strength of fiberglass posts of the same length as the dentin presented no differences according to the luting agent, but the post-length property influenced the bond strength when self-adhesive resin cement was used.


Objetivo: avaliar a influência dos agentes cimentantes e dos diferentes comprimentos de pinos na resistência de união de pinos de fibra de vidro a dentina. Métodos: Sessenta dentes bovinos uniradiculares tiveram a raiz endodonticamente tratada, e foram incluídos em poliéter e resina acrílica para simular o ligamento periodontal. Os espécimes foram divididos em seis grupos de acordo com o comprimento dos pinos (6, 10 ou 14mm) e dos agentes de cimentantes (cimento resinoso dual autoadesivo (RelyX U200, 3M ESPE) - U; ou cimento resinoso dual convencional (AllCem Core, FGM) - A: U6, U10, U14, A6, A19 e A14. Todos os pinos de fibra de vidro foram cimentados conforme as recomendações do fabricante. Após, o envelhecimento mecânico (1,2x106 ciclos; 4 Hz, 90 N) as amostras foram fatiadas para o teste de push-out (2,0 ± 0,1 mm) executado em uma máquina de ensaio universal (10 kgf a 0,5 mm/min). Os dados foram submetidos ao teste de Kruskal-Wallis e Dunn. Resultados: não houve diferença estatística na resistência de união entre os grupos devido ao tipo de agente cimentante (p > 0,05), mas houve para o comprimento dos pinos dos grupos U (p < 0,05). O grupo U10 apresentou valores de união semelhantes a U6, mas estatisticamente inferiores ao U14. Conclusão: a resistência de união dos pinos de fibra de vidro de um mesmo comprimento não apresentou diferenças mesmo quando cimentados com cimentos diferentes, mas o comprimento dos pinos isoladamente influenciou quando o cimento resinoso autoadesivo foi utilizado.


Assuntos
Resinas Acrílicas , Teste de Materiais , Cimentos de Resina , Cimentos Dentários , Ciência dos Materiais , Cimentos de Ionômeros de Vidro , Pinos Dentários
18.
RGO (Porto Alegre) ; 68: e20200001, 2020. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1091892

RESUMO

ABSTRACT Objective Evaluate the influence of silane heat treatment in bond durability between two resin cements and CAD/CAM feldspathic ceramic. Methods 40 feldspathic ceramic blocks were obtained, and were duplicated in microhybrid composite. All ceramic blocks were etched with 10% hydrofluoric acid for 20 s and received application of silane agent. The blocks were randomizedinto eight groups (n=5) according to the surface treatments and luting agents: P- Panavia F; PAg- Panavia F + Aging; HP- Heat Treatment + Panavia F; HPAg- Heat Treatment + Panavia F + Aging; R- RelyX ARC; Rag- RelyX ARC + Aging; HR- Heat Treatment + RelyX ARC; HRAg- Heat Treatment + RelyX ARC + Aging. The heat treatment was performed in furnace at 100 °C for 2 min. All blocks were cemented and cut to obtain samples with adhesive area of 1 mm2. Aging was performed with 10000 thermal cycles. The samples were subjected to microtensile bond strength test. Results The three-way ANOVA test revealed a significant interaction between cement versus heat treatment (p=0.001) and heat treatment versus thermal cycling (p=0.001) indicating that there was a change in bond strength due to surface treatment and aging. Conclusion Therefore, the heat treatment of the silane at 100 ºC for 2 minutes obtained higher values of bond strength between the resin cement and a feldspathic ceramicafter aging.


RESUMO Objetivo Avaliar a influência do tratamento térmico do silano na resistência de união entre dois cimentos resinosos e uma cerâmica feldspática CAD/CAM. Métodos Quarenta blocos cerâmicos foram duplicados em resina micro-híbrida. Todas as cerâmicas foram condicionadas com ácido fluorídrico 10% por 20 s e receberam aplicação do silano. Os blocos foram randomizados em oito grupos (n = 5): P-Panavia F; PAg- Panavia F + Envelhecimento; HP-Tratamento térmico + Panavia F;HPAg-Tratamento térmico + Panavia F + Envelhecimento; R-RelyX ARC; RAg-RelyX ARC; HR-Tratamento térmico + RelyX ARC; HRAg - Tratamento térmico + RelyX ARC + Envelhecimento. O tratamento térmico foi realizado em forno a 100 °C durante2 min. Todos os blocos foram cimentados e cortados para obter amostras para microtração. Foram feitos 10000 ciclos térmicos. As amostras foram submetidas a teste de micro-tração. Resultados O teste ANOVA revelou uma interação significativa entre cimento/tratamento térmico (p=0,001) e tratamento térmico/ciclo térmico (p=0,001). Conclusão Dessa maneira, o tratamentotérmico do silano a 100ºC por 2 minutos foi capaz de aumentar a resistência de união entre o cimento resinoso e uma cerâmica feldspática mesmo após o envelhecimento.

19.
Braz. dent. sci ; 22(3): 305-312, 2019. tab, ilus
Artigo em Inglês | LILACS, BBO | ID: biblio-1008364

RESUMO

Objective: The aim of the study was to evaluate the influence of different surface post-etching treatments in flexural strength, contact angle and surface roughness of a lithium disilicate ceramic. Material and Methods: 60 bars (16 x 2 x 4 mm) were divided in six groups (n=10): C, no treatment; HF, hydrofluoric acid for 20 s (HF) + washing (60 s), drying (30s); HFL, HF + washing (60 s), drying (30 s) and luting; HFNL, HF + washing (60 s) + neutralization with sodium bicarbonate (SB) for 40 s + washing (5s), drying (30 s) and luting; HFUL, HF + washing (60 s) + ultrasonic bath (UB) for 4 min, drying (30 s) and luting; HFNUL, HF + washing (60 s) + SB (40 s) + UB (4 min) and luting. The bars were submitted to three-points flexural strength test. 25 ceramic blocks (12 x 7 x 7 mm) were divided into five groups (n=5) to evaluate roughness and contact angle C - no treatment; HF - HF ; HFU - HF and UB for 5 min ; HFN - HF and SB; HFNU - HF, UB and SB. A scanning electron microscope (SEM) showed the surface of the samples. ANOVA one-way statistical analysis was done for comparison of results. Results: There was no statistical difference for flexural strength (p-value = 0.15) and for surface roughness (p-valor = 0.15). However, it was obtained statistically significant difference for contact angle (p-valor = 0.00). SEM images showed precipitates after the acid etching, which were removed by post-etching treatments. Conclusion: It can be concluded that the different post-etching surface treatments did not increase the flexural strength, surface roughness, but it influenced the ceramic wetting and SEM images (AU)


Objetivo: O objetivo do estudo foi avaliar a influência de diferentes tratamentos pós-condicionamento na resistência à flexão, ângulo de contato e rugosidade superficial de uma cerâmica de dissilicato de lítio. Material e Métodos: 60 barras (16 x 2 x 4 mm) foram divididas em seis grupos (n = 10): C, sem tratamento; HF, ácido fluorídrico durante 20 s (HF) + lavagem (60 s), secagem (30 s); HFL, lavagem com HF + (60 s), secagem (30 s) e cimentação; HFNL, HF + lavagem (60 s) + neutralização com bicarbonato de sódio (SB) por 40 s + lavagem (5s), secagem (30 s) e cimentação; HFUL, HF + lavagem (60 s) + banho ultrassônico (UB) por 4 min, secagem (30 s) e cimentação; HFNUL, HF + lavagem (60 s) + SB (40 s) + UB (4 min) e cimentação. As barras foram submetidas ao teste de resistência à flexão de três pontos. 25 blocos cerâmicos (12 x 7 x 7 mm) foram divididos em cinco grupos (n = 5) para avaliação da rugosidade superficial e ângulo de contato C - sem tratamento; HF - HF; HFU - HF e UB por 5 min; HFN - HF e SB; HFNU - HF, UB e SB. Um microscópio eletrônico de varredura (MEV) foi utilizado para análise da superfície das amostras. A análise estatística unidirecional ANOVA-um fator foi realizada para comparação dos resultados. Resultados: Não houve diferença estatística para a resistência à flexão (p-valor = 0,15) e para a rugosidade superficial (p-valor = 0,15). No entanto, obteve-se diferença estatisticamente significante para o ângulo de contato (p-valor = 0,00). Imagens de microscopia eletrônica de varredura mostraram a formação de precipitados após o ataque ácido, que foram removidos pelos tratamentos pós-condicionamento. Conclusão: Pode-se concluir que os diferentes tratamentos de superfície pós-condicionamento não aumentaram a resistência à flexão, rugosidade da superfície, mas influenciaram na molhabilidade da cerâmica e nas imagens em MEV.(AU)


Assuntos
Tomografia com Microscopia Eletrônica , Resistência à Flexão , Ácido Fluorídrico
20.
Braz. dent. sci ; 22(4): 573-577, 2019. ilus
Artigo em Inglês | BBO, LILACS | ID: biblio-1024963

RESUMO

Accurate color selection of direct or indirect dental restorations is a subjective task. Mobile phones are tools that may minimize color assessment errors. The objective was to use photographs taken with smartphones to guide the dental surgeon in choosing the right color in oral rehabilitation. A tooth was photographed for color assessment and the VITA Toothguide 3D-MASTER® shade guide was used. Photographs were submitted to an image editing software for full saturation removal. Images of the tooth and scale in black and white were compared. This method allowed to select the tooth's value, which is considered the most subjective dimension in color choice. Although it is an auxiliary and complementary method to traditional methods, smartphones are tools capable of reducing the range of color possibilities and minimizing possible failures (AU)


A correta seleção da cor das restaurações dentais diretas ou indiretas é uma atividade subjetiva. Os celulares são ferramentas que podem minimizar os erros da tomada de cor. O objetivo foi utilizar fotografias realizadas com smartphones para orientar o cirurgião-dentista na escolha da cor em reabilitação oral. Foi fotografado um dente para tomada de cor e a escala Vita 3D Master. As imagens foram submetidas a um software de edição de imagem para remoção total da saturação. As imagens em preto e branco do dente e da escala foram comparadas. A metodologia permitiu selecionar o valor do dente que é o aspecto considerado mais subjetivo na escolha da cor. Apesar de ser um método auxiliar e complementar aos métodos tradicionais é uma ferramenta capaz de diminuir o leque de possibilidades de cores e minimizar possíveis falhas (AU)


Assuntos
Dente , Cor , Fotografia Dentária , Telefone Celular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA