Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr Orthop ; 2024 Aug 22.
Artigo em Inglês | MEDLINE | ID: mdl-39171367

RESUMO

OBJECTIVE: While the implementation of enhanced recovery after surgery protocols and improvements in pain control have decreased the length of stay (LOS) after scoliosis surgery, adolescents are typically hospitalized for several days after posterior spinal instrumented fusion (PSF). The purpose of this study was to determine whether next-day discharge after PSF for adolescent idiopathic scoliosis (AIS) had an equivalent safety profile compared with longer LOS. The secondary purpose was to examine perioperative factors associated with next-day discharge. METHODS: We performed a retrospective study of all patients who underwent PSF for AIS at a single institution from 2017 to 2022. We compared patients based on postoperative LOS with an early discharge group consisting of those who were discharged on the first postoperative day 1 (POD1; n = 40) and a standard discharge group consisting of those who were discharged after POD1 (n = 71). We documented preoperative variables, including patient demographics and curve characteristics, intraoperative variables, including levels fused, implant density, operative time, and blood loss, and postoperative variables, including emergency department (ED) visits within 30 days and hospital readmissions within 90 days. RESULTS: One hundred eleven patients were included with a mean curve magnitude of 67 degrees. Forty patients (36%) were discharged on POD1. There were one (3%) ED visit and 2 (5%) readmissions in the early discharge group and 3 (4%) ED visits and 2 (3%) readmissions in the standard discharge group (P = 0.64 and 0.55, respectively). Patients in whom intravenous methadone was used intraoperatively were more likely to discharge POD1 (P = 0.02). There were no other significant differences in perioperative variables between the two groups including: BMI, distance from home to hospital, magnitude of main curve, curve flexibility, number of levels fused, estimated blood loss, implant density, operative time, or postoperative pain scores. CONCLUSIONS: Next-day discharge after PSF for AIS has an equivalent safety profile compared with longer LOS. Over one-third of patients were discharged on POD1, and there was no statistically significant difference in ED visits or hospital readmissions between the groups. Patients in whom intravenous methadone was used intraoperatively were more likely to discharge POD1. CLINICAL RELEVANCE: In a retrospective study of posterior spinal fusions for AIS, we found no increase in ED visits or hospital readmissions for those discharged the next day. LEVEL OF EVIDENCE: Level III.

2.
J Pediatr Orthop ; 44(1): 63-67, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37796155

RESUMO

BACKGROUND: Thermal injuries can occur during cast removal with an oscillating saw. The purpose of this study is to describe the effect of blade material, blade wear, and cast material on blade temperature. METHODS: Short arm plaster and fiberglass casts were cured overnight and bivalved with either new or worn stainless-steel or tungsten-disulfide coated blades. Blade use was defined as removing 1 short arm cast. Blades used to remove more than 20 casts were defined as worn. Ten trials were performed with each combination of blade material, blade wear, and cast material, except for the combination of fiberglass and a worn stainless-steel blade due to complete erosion of cutting teeth. Thirty casts were removed with stainless-steel blades, and 40 casts were removed with coated blades. Blade temperature was measured continuously at 5 Hz using a T-type thermocouple and microcontroller board. A Mann-Whitney U test was used to compare the mean maximum temperature between groups. RESULTS: For plaster casts, new and worn stainless-steel blades produced mean maximum temperatures of 51.4°C and 63.7°C ( P =0.003), respectively. New stainless-steel blades produced significantly higher mean maximum temperatures on fiberglass casts than plaster casts (95.9°C vs. 51.4°C, P <.001). For plaster casts, new and worn coated blades produced mean maximum temperatures of 56.9°C and 53.8°C ( P =0.347). For fiberglass casts, new and worn coated blades produced mean maximum temperatures of 76.6°C and 77.7°C ( P =0.653). As with new stainless-steel blades, new coated blades produced significantly higher mean maximum temperatures on fiberglass than plaster (76.6°C vs. 56.9°C, P <0.001). Mean maximum temperatures between new stainless-steel and coated blades during removal of plaster casts were 51.4°C and 56.9°C ( P =0.131), respectively. However, new coated blades demonstrated significantly lower mean maximum temperatures during fiberglass cast removal compared to new stainless-steel blades (76.6°C vs. 95.9°C, P =0.016). CONCLUSIONS: Coated blades outperformed stainless-steel in nearly all combinations. We recommend limited use of stainless-steel blades to minimize blade temperatures during cast removal. CLINICAL RELEVANCE: Appropriate selection of blade material and monitoring blade wear minimizes blade temperature during cast removal.


Assuntos
Remoção de Dispositivo , Procedimentos Ortopédicos , Humanos , Temperatura , Moldes Cirúrgicos , Aço Inoxidável
3.
Trauma Surg Acute Care Open ; 9(1): e001355, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38375026

RESUMO

Innovations in projectile design present unique challenges for trauma surgeons when treating gunshot victims. The G2 Radically Invasive Projectile (G2 Research, Winder, Georgia, USA) (G2RIP) is a frangible, rapidly expanding bullet resulting in a distinct pattern of injury consisting of diffuse hemorrhage with multicavity trauma as well as unique radiographic features of the projectile. To efficiently manage patients injured by the G2RIP, trauma surgeons must be aware of these distinct characteristics, and of previous patterns in effective management such as liberal damage control and extensive use of CT. Understanding previous presentation and management of patients injured by the G2RIP can aid in improving patient care in the trauma center.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA