Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 405
Filtrar
1.
J Ultrasound Med ; 42(2): 309-344, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35993596

RESUMO

Following the innovations and new discoveries of the last 10 years in the field of lung ultrasound (LUS), a multidisciplinary panel of international LUS experts from six countries and from different fields (clinical and technical) reviewed and updated the original international consensus for point-of-care LUS, dated 2012. As a result, a total of 20 statements have been produced. Each statement is complemented by guidelines and future developments proposals. The statements are furthermore classified based on their nature as technical (5), clinical (11), educational (3), and safety (1) statements.


Assuntos
COVID-19 , Humanos , SARS-CoV-2 , Consenso , Pulmão/diagnóstico por imagem , Testes Imediatos , Ultrassonografia
2.
Tech Coloproctol ; 27(9): 747-757, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-36749438

RESUMO

BACKGROUND: Immunocompromised patients with acute diverticulitis are at increased risk of morbidity and mortality. The aim of this study was to compare clinical presentations, types of treatment, and outcomes between immunocompromised and immunocompetent patients with acute diverticulitis. METHODS: We compared the data of patients with acute diverticulitis extracted from the Web-based International Registry of Emergency Surgery and Trauma (WIRES-T) from January 2018 to December 2021. First, two groups were identified: medical therapy (A) and surgical therapy (B). Each group was divided into three subgroups: nonimmunocompromised (grade 0), mildly to moderately (grade 1), and severely immunocompromised (grade 2). RESULTS: Data from 482 patients were analyzed-229 patients (47.5%) [M:F = 1:1; median age: 60 (24-95) years] in group A and 253 patients (52.5%) [M:F = 1:1; median age: 71 (26-94) years] in group B. There was a significant difference between the two groups in grade distribution: 69.9% versus 38.3% for grade 0, 26.6% versus 51% for grade 1, and 3.5% versus 10.7% for grade 2 (p < 0.00001). In group A, severe sepsis (p = 0.027) was more common in higher grades of immunodeficiency. Patients with grade 2 needed longer hospitalization (p = 0.005). In group B, a similar condition was found in terms of severe sepsis (p = 0.002), quick Sequential Organ Failure Assessment score > 2 (p = 0.0002), and Mannheim Peritonitis Index (p = 0.010). A Hartmann's procedure is mainly performed in grades 1-2 (p < 0.0001). Major complications increased significantly after a Hartmann's procedure (p = 0.047). Mortality was higher in the immunocompromised patients (p = 0.002). CONCLUSIONS: Immunocompromised patients with acute diverticulitis present with a more severe clinical picture. When surgery is required, immunocompromised patients mainly undergo a Hartmann's procedure. Postoperative morbidity and mortality are, however, higher in immunocompromised patients, who also require a longer hospital stay.


Assuntos
Doença Diverticular do Colo , Diverticulite , Perfuração Intestinal , Peritonite , Humanos , Pessoa de Meia-Idade , Idoso , Doença Diverticular do Colo/cirurgia , Doença Diverticular do Colo/complicações , Resultado do Tratamento , Diverticulite/complicações , Colostomia/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Hospedeiro Imunocomprometido , Internet , Perfuração Intestinal/etiologia , Perfuração Intestinal/cirurgia , Peritonite/etiologia
3.
Can J Surg ; 66(1): E48-E51, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36731913

RESUMO

The comparative performance of synthetic and biologic meshes in complex and contaminated abdominal wall repairs remains controversial. Though biologic meshes are generally favoured in contaminated fields, this practice is based on limited data. Standard dictum regarding infected mesh is to either explant it early or pursue aggressive conservation measures depending on mesh position and composition. Explantation is typically morbid, leaving the patient with recurrent hernias and few reconstructive options. We report a case in which a hernia repaired with synthetic mesh recurred and was reconstructed with underlay biologic mesh. Delayed wound hematoma occurred after initiating anticoagulation for late postoperative pulmonary embolism, which became chronically infected. After multiple failed attempts at medical and interventional salvage of the mesh infection, the patient underwent selective explantation of synthetic mesh with conservation of the underlying biological mesh. She recovered completely without recurrent abdominal wall failure at long-term follow-up. We suggest the "salvageable" characteristics of biologic meshes may allow conservation, rather than explantation, in select cases of infection.


Assuntos
Parede Abdominal , Hérnia Ventral , Herniorrafia , Telas Cirúrgicas , Feminino , Humanos , Parede Abdominal/cirurgia , Produtos Biológicos , Hérnia Ventral/cirurgia , Herniorrafia/efeitos adversos , Recidiva , Telas Cirúrgicas/efeitos adversos , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/cirurgia , Resultado do Tratamento
4.
Can J Surg ; 66(6): E522-E534, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37914210

RESUMO

People suffering from critical injuries/illness face marked challenges before transportation to definitive care. Solutions to diagnose and intervene in the prehospital setting are required to improve outcomes. Despite advances in artificial intelligence and robotics, near-term practical interventions for catastrophic injuries/illness will require humans to perform unfamiliar, uncomfortable and risky interventions. Development of posttraumatic stress disorder is already disproportionately high among first responders and correlates with uncertainty and doubts concerning decisions, actions and inactions. Technologies such as remote telementoring (RTM) may enable such interventions and will hopefully decrease potential stress for first responders. How thought processes may be remotely assisted using RTM and other technologies should be studied urgently. We need to understand if the use of cognitively offloading technologies such as RTM will alleviate, or at least not exacerbate, the psychological stresses currently disabling first responders.


Assuntos
Inteligência Artificial , Serviços Médicos de Emergência , Humanos , Cognição
5.
Annu Rev Biomed Eng ; 23: 115-139, 2021 07 13.
Artigo em Inglês | MEDLINE | ID: mdl-33770455

RESUMO

Telemedicine is perhaps the most rapidly growing area in health care. Approximately 15 million Americans receive medical assistance remotely every year. Yet rural communities face significant challenges in securing subspecialist care. In the United States, 25% of the population resides in rural areas, where less than 15% of physicians work. Current surgery residency programs do not adequately prepare surgeons for rural practice. Telementoring, wherein a remote expert guides a less experienced caregiver, has been proposed to address this challenge. Nonetheless, existing mentoring technologies are not widely available to rural communities, due to a lack of infrastructure and mentor availability. For this reason, some clinicians prefer simpler and more reliable technologies. This article presents past and current telementoring systems, with a focus on rural settings, and proposes aset of requirements for such systems. We conclude with a perspective on the future of telementoring systems and the integration of artificial intelligence within those systems.


Assuntos
Tutoria , Cirurgiões , Telemedicina , Inteligência Artificial , Humanos , População Rural , Estados Unidos
6.
Opt Express ; 30(7): 11809-11824, 2022 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-35473116

RESUMO

Phase aberrations are introduced when focusing by a high-numerical aperture (NA) objective lens into refractive-index-mismatched (RIM) media. The axial focus position in these media can be adjusted through either optical remote-focusing or mechanical stage translation. Despite the wide interest in remote-focusing, no generalised control algorithm using Zernike polynomials has been presented that performs independent remote-focusing and RIM correction in combination with mechanical stage translation. In this work, we thoroughly review derivations that model high-NA defocus and RIM aberration. We show through both numerical simulation and experimental results that optical remote-focusing using an adaptive device and mechanical stage translation are not optically equivalent processes, such that one cannot fully compensate for the other without additional aberration compensation. We further establish new orthogonal modes formulated using conventional Zernike modes and discuss its device programming to control high-NA remote-focusing and RIM correction as independent primary modes in combination with mechanical stage translation for aberration-free refocusing. Numerical simulations are performed, and control algorithms are validated experimentally by fabricating graphitic features in diamond using direct laser writing.

7.
Can J Surg ; 65(5): E720-E726, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36283697

RESUMO

BACKGROUND: Open surgical and percutaneous endovascular procedures aimed at arresting traumatic life-threatening hemorrhage are usually performed in rapid serial fashion by surgeons and interventional radiologists; truly simultaneous procedures require modifications in technique, workflow and team collaboration. The primary objective of this study was to prospectively audit outcomes in patients with ongoing hemorrhage who underwent truly simultaneous open and percutaneous procedures. METHODS: We prospectively evaluated the cases of all severely injured patients who required an open and percutaneous procedure within the hybrid RAPTOR (resuscitation with angiography, percutaneous techniques and operative repair) suite at the Foothills Medical Centre, Calgary, Alberta, Canada, between Apr. 4, 2013, and Dec. 5, 2019. We compared outcomes between the truly simultaneous and rapid serial cases. RESULTS: Thirty-five patients (31 [89%] male, median age 46 yr, median Injury Severity Score 30, blunt mechanism in 26 cases [74%]) underwent a hybrid intervention in the RAPTOR suite to stop ongoing hemorrhage during the study period. Twenty-three patients (66%) had a rapid serial procedure, and 12 (34%) had a truly simultaneous procedure. Demographic characteristics were similar between the 2 groups. Compared to the rapid serial group, a higher proportion of patients in the truly simultaneous group were hemodynamically unstable (11 [92%] v. 13 [56%], p = 0.03) and required damage-control procedures (10 [83%] v. 12 [52%], p = 0.03). The time from hospital arrival to procedure initiation was shorter for the truly simultaneous group (mean 31 min v. 59 min, p = 0.02), and a lower proportion had initial radiologic studies (3 [25%] v. 16 [70%], p = 0.01). The median hospital length of stay, intensive care unit stay and mortality rate were similar between the 2 groups. CONCLUSION: Truly simultaneous open and percutaneous procedures to stop ongoing hemorrhage were unique in both patient and procedural details. For the most severely injured patients, the provision of truly simultaneous modalities is necessary to achieve clinical outcomes equivalent to those of less ill patients.


Assuntos
Aves Predatórias , Humanos , Masculino , Animais , Pessoa de Meia-Idade , Feminino , Escala de Gravidade do Ferimento , Hemorragia , Ressuscitação/métodos , Alberta , Estudos Retrospectivos , Resultado do Tratamento
8.
Can J Surg ; 65(2): E266-E268, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35396269

RESUMO

The Pringle manoeuvre (vascular inflow occlusion) has been a mainstay technique in trauma surgery and hepato-pancreato-biliary surgery since it was first described in the early 1900s. We sought to determine how frequently the manoeuvre is used today for both elective and emergent cases in these disciplines. To reflect on its evolution, we evaluated the Pringle manoeuvre over a recent 10-year period (2010-2020). We found it is used less frequently owing to more frequent nonoperative management and more advanced elective hepatic resection techniques. Continuing educational collaboration is critical to ensure continued insight into the impact of hepatic vascular inflow occlusion among trainees who observe this procedure less frequently.


Assuntos
Hepatectomia , Neoplasias Hepáticas , Perda Sanguínea Cirúrgica , Procedimentos Cirúrgicos Eletivos , Hepatectomia/métodos , Humanos , Fígado/cirurgia , Neoplasias Hepáticas/cirurgia
9.
Can J Surg ; 65(4): E541-E549, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35961662

RESUMO

BACKGROUND: Complex abdominal wall reconstruction technique remains controversial. The use of biologic mesh products is also debated in active infection, sepsis prophylaxis and high-risk patients. Differences in biologic mesh technology and cost remain significant. We aimed to compare the efficacy of 2 commonly used biologic meshes in regards to hernia recurrence at 1 year. METHODS: This study was a parallel, dual-arm, double-blind randomized controlled trial involving adult patients undergoing complex abdominal wall reconstruction with a biologic mesh at a quaternary care institution (2017-2020). Patients were randomly assigned to receive Permacol (cross-linked) compared with Strattice (not crosslinked). The main outcome measure was hernia recurrence at 1 or more years following the index repair. RESULTS: We included 94 patients randomized to undergo reconstruction with 1 of 2 commonly used biologic mesh products (mean age 59.4 yr, standard deviation [SD] 9.9; 51% female; body mass index 32.9, SD 6.8). We found no significant differences between the groups (patient comorbidities, hernia recurrence risk factors, hernia size or infection profiles). Hernia recurrence rates (15%) were similar between groups (median 783 days of follow up, interquartile range 119). We found there was significantly less of a need for a component separation technique in the Strattice group (69% v. 87%). All other secondary outcome measures were equivalent between study arms. Multivariate analysis identified hepatic transplantation (odds ratio [OR] 1.94, 95% confidence intervals [CI] 0.33-4.41), active abdominal wall infection (OR 2.01, 95% CI 0.50-7.01), and more than 1 previous hernia repair (OR 2.68, 95% CI 0.41-5.99) as risk factors for subsequent hernia recurrence; however, there was no difference in recurrence factors between patient study groups. CONCLUSION: Given similar clinical performance between the 2 most commonly used biologic mesh products, the most cost effective mesh should be used in cost-conscious health care systems.


Assuntos
Parede Abdominal , Produtos Biológicos , Hérnia Ventral , Parede Abdominal/cirurgia , Adulto , Feminino , Hérnia Ventral/prevenção & controle , Hérnia Ventral/cirurgia , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Estudos Retrospectivos , Telas Cirúrgicas , Resultado do Tratamento
10.
Can J Surg ; 65(2): E242-E249, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35365497

RESUMO

BACKGROUND: Early hemorrhage control after interpersonal violence is the most urgent requirement to preserve life and is now recognized as a responsibility of law enforcement. Although earlier entry of first responders is advocated, many shooting scenes remain unsafe for humans, necessitating first responses conducted by robots. Thus, robotic hemorrhage control warrants study as a care-under-fire treatment option. METHODS: Two bomb disposal robots (Wolverine and Dragon Runner) were retrofitted with hemostatic wound clamps. The robots' ability to apply a wound clamp to a simulated extremity exsanguination while controlled by 4 experienced operators was tested. The operators were randomly assigned to perform 10 trials using 1 robot each. A third surveillance robot (Stair Climber) provided further visualization for the operators. We assessed the success rate of the application of the wound clamp to the simulated wound, the time to application of the wound clamp and the amount of fluid loss. We also assessed the operators' efforts to apply the wound clamp after an initial attempt was unsuccessful or after the wound clamp was dropped. RESULTS: Remote robotic application of a wound clamp was demonstrated to be feasible, with complete cessation of simulated bleeding in 60% of applications. This finding was consistent across all operators and both robots. There was no difference in the success rates with the 2 robots (p = 1.00). However, there were differences in fluid loss (p = 0.004) and application time (p < 0.001), with the larger (Wolverine) robot being faster and losing less fluid. CONCLUSION: Law enforcement tactical robots were consistently able to provide partial to complete hemorrhage control in a simulated extremity exsanguination. Consideration should be given to using this approach in care-under-fire and care-behind-the-barricade scenarios as well as further developing the technology and doctrine for robotic hemorrhage control.


Assuntos
Bombas (Dispositivos Explosivos) , Hemostáticos , Robótica , Constrição , Hemorragia/etiologia , Hemorragia/prevenção & controle , Humanos
11.
Can J Surg ; 65(3): E310-E316, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35545282

RESUMO

SummaryResuscitative endovascular balloon occlusion of the aorta (REBOA) is a well-described intervention for noncompressible torso hemorrhage. Several Canadian centres have included REBOA in their hemorrhagic shock protocols. However, REBOA has known complications and equipoise regarding its use persists. The Canadian Collaborative on Urgent Care Surgery (CANUCS) comprises surgeons who provide acute trauma care and leadership in Canada, with experience in REBOA implementation, use, education and research. Our goal is to provide evidence- and experience-based recommendations regarding institutional implementation of a REBOA program, including multidisciplinary educational programs, attention to device and care pathway logistics, and a robust quality assurance program. This will allow Canadian trauma centres to maximize patient benefits and minimize risks of this potentially life-saving technology.


Assuntos
Oclusão com Balão , Procedimentos Endovasculares , Choque Hemorrágico , Assistência Ambulatorial , Aorta/lesões , Aorta/cirurgia , Oclusão com Balão/métodos , Canadá , Procedimentos Endovasculares/métodos , Humanos , Ressuscitação/métodos , Choque Hemorrágico/cirurgia
12.
Isr Med Assoc J ; 24(9): 596-601, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36168179

RESUMO

BACKGROUND: Handheld ultrasound devices present an opportunity for prehospital sonographic assessment of trauma, even in the hands of novice operators commonly found in military, maritime, or other austere environments. However, the reliability of such point-of-care ultrasound (POCUS) examinations by novices is rightly questioned. A common strategy being examined to mitigate this reliability gap is remote mentoring by an expert. OBJECTIVES: To assess the feasibility of utilizing POCUS in the hands of novice military or civilian emergency medicine service (EMS) providers, with and without the use of telementoring. To assess the mitigating or exacerbating effect telementoring may have on operator stress. METHODS: Thirty-seven inexperienced physicians and EMTs serving as first responders in military or civilian EMS were randomized to receive or not receive telementoring during three POCUS trials: live model, Simbionix trainer, and jugular phantom. Salivary cortisol was obtained before and after the trial. Heart rate variability monitoring was performed throughout the trial. RESULTS: There were no significant differences in clinical performance between the two groups. Iatrogenic complications of jugular venous catheterization were reduced by 26% in the telementored group (P < 0.001). Salivary cortisol levels dropped by 39% (P < 0.001) in the telementored group. Heart rate variability data also suggested mitigation of stress. CONCLUSIONS: Telementoring of POCUS tasks was not found to improve performance by novices, but findings suggest that it may mitigate caregiver stress.


Assuntos
Serviços Médicos de Emergência , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Hidrocortisona , Reprodutibilidade dos Testes , Ultrassonografia
13.
BMC Biol ; 18(1): 79, 2020 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-32620121

RESUMO

BACKGROUND: Luminescent reporter proteins are vital tools for visualizing cells and cellular activity. Among the current toolbox of bioluminescent systems, only bacterial luciferase has genetically defined luciferase and luciferin synthesis pathways that are functional at the mammalian cell temperature optimum of 37 °C and have the potential for in vivo applications. However, this system is not functional in all cell types, including stem cells, where the ability to monitor continuously and in real-time cellular processes such as differentiation and proliferation would be particularly advantageous. RESULTS: We report that artificial subdivision of the bacterial luciferin and luciferase pathway subcomponents enables continuous or inducible bioluminescence in pluripotent and mesenchymal stem cells when the luciferin pathway is overexpressed with a 20-30:1 ratio. Ratio-based expression is demonstrated to have minimal effects on phenotype or differentiation while enabling autonomous bioluminescence without requiring external excitation. We used this method to assay the proliferation, viability, and toxicology responses of iPSCs and showed that these assays are comparable in their performance to established colorimetric assays. Furthermore, we used the continuous luminescence to track stem cell progeny post-differentiation. Finally, we show that tissue-specific promoters can be used to report cell fate with this system. CONCLUSIONS: Our findings expand the utility of bacterial luciferase and provide a new tool for stem cell research by providing a method to easily enable continuous, non-invasive bioluminescent monitoring in pluripotent cells.


Assuntos
Diferenciação Celular , Proliferação de Células , Sobrevivência Celular , Medições Luminescentes/métodos , Células-Tronco/fisiologia , Linhagem Celular , Fibroblastos/fisiologia , Humanos , Proteínas Luminescentes/química
14.
Can J Surg ; 64(5): E537-E539, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34649922

RESUMO

Traumatic pneumothoraces remain a life-threatening problem that may be resolved quickly with timely diagnosis. Unfortunately, they are still not optimally managed. The most critically injured patients with hemodynamic instability require immediate diagnoses of potentially correctible conditions in the primary survey. Point-of-care ultrasonography (POCUS) performed by the responsible physician can be a tremendous adjunct to expediting diagnoses in the primary surgery and can typically be done in seconds rather than minutes. If more detailed sonographic examination is required, the secondary survey of the hemodynamically unstable patient is more appropriate. All involved in bedside care need to be conscious to efficiently integrate POCUS into resuscitation with the right intentions and goals to avoid sono-paralysis of the resuscitation sequence. Sono-paralysis has recently been described as critical situations wherein action is delayed through unnecessary imaging after a critical diagnosis has been made or unnecessary imaging details are sought despite an urgent diagnosis being made.


Assuntos
Pneumotórax/diagnóstico , Testes Imediatos , Ressuscitação , Ultrassonografia , Procedimentos Desnecessários , Humanos , Pneumotórax/diagnóstico por imagem , Testes Imediatos/normas , Radiografia , Ressuscitação/normas , Ultrassonografia/normas
15.
Can J Surg ; 64(6): E677-E679, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34933945

RESUMO

Traumatic inuries to the pancreas are notoriously challenging to diagnose and treat. Detecting a main pancreatic ductal injury can be particularly difficult on screening computed tomography (CT). Twenty-four blinded faculty clinicians from 4 differing specialties and 6 institutions reviewed 9 video CT cases of potential pancreatic ductal injuries. Clinician performance in detection of confirmed grade III pancreatic injuries varied widely among specialties. This heterogeneity confirms the critical need for multidisciplinary care and image interpretation for even "minor" (i.e., not grade IV or V) potential pancreatic injuries to optimize outcomes for injured patients. The ubiquitous availability of electronic devices allows real-time collegial second opinions to be easily available.


Assuntos
Ductos Pancreáticos/lesões , Tomografia Computadorizada por Raios X , Ferimentos não Penetrantes/diagnóstico , Humanos , Variações Dependentes do Observador , Ductos Pancreáticos/diagnóstico por imagem , Índice de Gravidade de Doença
16.
J Digit Imaging ; 34(4): 841-845, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34173090

RESUMO

Remotely Piloted Aerial Systems (RPAS) are poised to revolutionize healthcare in out-of-hospital settings, either from necessity or practicality, especially for remote locations. RPAS have been successfully used for surveillance, search and rescue, delivery, and equipping drones with telemedical capabilities being considered. However, we know of no previous consideration of RPAS-delivered tele-ultrasound capabilities. Of all imaging technologies, ultrasound is the most portable and capable of providing real-time point-of-care information regarding anatomy, physiology, and procedural guidance. Moreover, remotely guided ultrasound including self-performed has been a backbone of medical care on the International Space Station since construction. The TeleMentored Ultrasound Supported Medical Interventions Group of the University of Calgary partnered with the Southern Alberta Institute of Technology to demonstrate RPAS delivery of a smartphone-supported tele-ultrasound system by the SwissDrones SDO50 RPAS. Upon receipt of the sanitized probe, a completely ultrasound-naïve volunteer was guided by a remote expert located 100 km away using online video conferencing (Zoom), to conduct a self-performed lung ultrasound examination. It proved feasible for the volunteer to examine their anterior chest, sides, and lower back bilaterally, correlating with standard recommended examinations in trauma/critical care, including the critical locations of a detailed COVID-19 lung diagnosis/surveillance examination. We contend that drone-delivered telemedicine including a tele-ultrasound capability could be leveraged to enhance point-of-care diagnostic accuracy in catastrophic emergencies, and allow diagnostic capabilities to be delivered to vulnerable populations in remote locations for whom transport is impractical or undesirable, speeding response times, or obviating the risk of disease transmission depending on the circumstances.


Assuntos
COVID-19 , Consulta Remota , Humanos , SARS-CoV-2 , Ultrassonografia , Populações Vulneráveis
17.
Ann Surg ; 271(5): 958-961, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-30601253

RESUMO

OBJECTIVE: The primary objective of this study was to evaluate the utility, clinical impact, and work flow of a new trauma hybrid operating theater. SUMMARY BACKGROUND DATA: The potential utility and clinical benefit of hybrid operating theaters are increasingly postulated. Unfortunately, the clinical outcomes and efficiencies of these environments remain unclear. METHODS: All severely injured patients who were transferred to the hybrid suite for emergent intervention between 2013 and 2017 were compared to consecutive prehybrid patients. Standard statistical methodology was employed (P < 0.05 = significant). RESULTS: One hundred sixty-nine patients with severe injuries (mean ISS = 23; hemodynamic instability = 70%; hospital/ICU stay = 12 d; mortality = 14%) were transferred urgently to the hybrid suite. Most were young (38 yrs) males (84%) with blunt injuries (51%). Combined hybrid trauma procedures occurred in 18% of cases (surgery (82%) and angiography (11%) alone). Procedures within the hybrid suite included: laparotomy (57%), extremity (14%), thoracotomy/sternotomy (12%), angioembolization of the spleen/pelvis/liver/other (9%), neck (9%), craniotomy (4%), and aortic endostenting (6%). Compared with historical controls, use of the hybrid suite resulted in shorter arrival to intervention and total procedure times (P < 0.05). A clear benefit for survival was evident (42% vs. 22%). CONCLUSIONS: Availability of a hybrid environment for severely injured patients reduces time to intervention, total procedural duration, blood product transfusion and salvages a small subset of patients who would not otherwise survive. The cost associated with a hybrid suite remains prohibitive for many centers.


Assuntos
Ambiente de Instituições de Saúde , Salas Cirúrgicas/estatística & dados numéricos , Avaliação de Resultados em Cuidados de Saúde , Ferimentos e Lesões/cirurgia , Adulto , Transfusão de Componentes Sanguíneos/estatística & dados numéricos , Canadá , Feminino , Humanos , Escala de Gravidade do Ferimento , Tempo de Internação/estatística & dados numéricos , Masculino , Duração da Cirurgia , Estudos Prospectivos , Tempo para o Tratamento/estatística & dados numéricos
18.
World J Surg ; 44(12): 4032-4040, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32833107

RESUMO

BACKGROUND: Open abdomen (OA) is a surgical option that can be used in patients with severe peritonitis. Few evidences exist to recommend the use of intraperitoneal fluid instillation associated with OA in managing septic abdomen. MATERIALS AND METHODS: A prospective analysis of adult patients enrolled in the International Register of Open Abdomen (trial registration: NCT02382770) was performed. RESULTS: A total of 387 patients were enrolled in two groups: 84 with peritoneal fluid instillation (FI) and 303 without (NFI). The groups were homogeneous for baseline characteristics. Overall complications were 92.9% in FI and 86.3% in NFI (p = 0.106). Complications during OA were 72.6% in FI and 59.9% in NFI (p = 0.034). Complications after definitive closure were 70.8% in FI and 61.1% in NFI (p = 0.133). Entero-atmospheric fistula was 13.1% in FI and 12% in NFI (p = 0.828). Fascial closure was 78.6% in FI and 63.7% in NFI (p = 0.02). Analysis of FI in negative pressure wound therapy (NPWT) showed: Overall morbidity in NPWT was 94% and in non-NPWT 91.2% (p = 0.622) and morbidity during OA was 68% and 79.4% (p = 0.25), respectively. Definitive fascial closure in NPWT was 87.8% and 96.8% in non-NPWT (p = 0.173). Overall mortality was 40% in NPWT and 29.4% in non-NPWT (p = 0.32) and morality during OA period was 18% and 8.8% (p = 0.238), respectively. CONCLUSION: We found intraperitoneal fluid instillation during open abdomen in peritonitic patients to increase the complication rate during the open abdomen period, with no impact on mortality, entero-atmospheric fistula rate and opening time. Fascial closure rate is increased by instillation. Fluid instillation is feasible even when associated with nonnegative pressure temporary abdominal closure techniques.


Assuntos
Abdome/cirurgia , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Hidratação , Tratamento de Ferimentos com Pressão Negativa/métodos , Sepse/etiologia , Infecção da Ferida Cirúrgica/terapia , Cavidade Abdominal , Técnicas de Fechamento de Ferimentos Abdominais , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Infecção da Ferida Cirúrgica/complicações , Resultado do Tratamento
19.
Ann Intern Med ; 171(12): 896-905, 2019 12 17.
Artigo em Inglês | MEDLINE | ID: mdl-31739316

RESUMO

Background: Optic nerve ultrasonography (optic nerve sheath diameter sonography) has been proposed as a noninvasive, quick method for diagnosing increased intracranial pressure. Purpose: To examine the accuracy of optic nerve ultrasonography for diagnosing increased intracranial pressure in children and adults. Data Sources: 13 databases from inception through May 2019, reference lists, and meeting proceedings. Study Selection: Prospective optic nerve ultrasonography diagnostic accuracy studies, published in any language, involving any age group or reference standard. Data Extraction: 3 reviewers independently abstracted data and performed quality assessment. Data Synthesis: Of 71 eligible studies involving 4551 patients, 61 included adults, and 35 were rated as having low risk of bias. The pooled sensitivity, specificity, positive likelihood ratio, and negative likelihood ratio of optic nerve ultrasonography in patients with traumatic brain injury were 97% (95% CI, 92% to 99%), 86% (CI, 74% to 93%), 6.93 (CI, 3.55 to 13.54), and 0.04 (CI, 0.02 to 0.10), respectively. Respective estimates in patients with nontraumatic brain injury were 92% (CI, 86% to 96%), 86% (CI, 77% to 92%), 6.39 (CI, 3.77 to 10.84), and 0.09 (CI, 0.05 to 0.17). Accuracy estimates were similar among studies stratified by patient age, operator specialty and training level, reference standard, sonographer blinding status, and cutoff value. The optimal cutoff for optic nerve sheath dilatation on ultrasonography was 5.0 mm. Limitation: Small studies, imprecise summary estimates, possible publication bias, and no evaluation of effect on clinical outcomes. Conclusion: Optic nerve ultrasonography can help diagnose increased intracranial pressure. A normal sheath diameter measurement has high sensitivity and a low negative likelihood ratio that may rule out increased intracranial pressure, whereas an elevated measurement, characterized by a high specificity and positive likelihood ratio, may indicate increased intracranial pressure and the need for additional confirmatory tests. Primary Funding Source: None. (PROSPERO: CRD42017055485).


Assuntos
Hipertensão Intracraniana/diagnóstico por imagem , Nervo Óptico/diagnóstico por imagem , Testes Imediatos , Ultrassonografia , Adulto , Lesões Encefálicas/complicações , Lesões Encefálicas/diagnóstico por imagem , Criança , Interpretação Estatística de Dados , Humanos , Hipertensão Intracraniana/diagnóstico , Hipertensão Intracraniana/etiologia , Pressão Intracraniana , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Ultrassonografia/métodos
20.
Can J Surg ; 63(6): E533-E536, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33211643

RESUMO

SUMMARY: Biologic mesh is preferred over synthetic mesh for complex and contaminated abdominal wall repairs; however, there are very little data on the risks and complications associated with its use. We report the case of a 67-year-old man with failed synthetic mesh repair for recurrent ventral hernia, who subsequently required an abdominal wall reconstruction (AWR), including the intraperitoneal sublay of noncrosslinked biologic mesh. His postoperative course was complicated with catastrophic sepsis and sustained hemodynamic instability, responding only to mesh explantation. The biologic mesh was subsequently noted to be histologically infected with invasive Candida albicans. Although noncrosslinked biologic mesh is a valuable adjunct to AWR, it is not infection-resistant. Although it is rare, infection of any foreign tissue, including biologic mesh, can occur in the setting of complex ventral abdominal wall repairs. Clinicians should be watchful for such infections in complex repairs as they may require biologic mesh explantation for clinical recovery.


Assuntos
Parede Abdominal/cirurgia , Candida albicans/isolamento & purificação , Candidíase Invasiva/cirurgia , Remoção de Dispositivo , Procedimentos de Cirurgia Plástica/efeitos adversos , Infecção da Ferida Cirúrgica/cirurgia , Alicerces Teciduais/microbiologia , Idoso , Animais , Candidíase Invasiva/diagnóstico , Candidíase Invasiva/microbiologia , Hérnia Ventral/cirurgia , Herniorrafia/efeitos adversos , Humanos , Masculino , Procedimentos de Cirurgia Plástica/instrumentação , Recidiva , Infecção da Ferida Cirúrgica/diagnóstico , Infecção da Ferida Cirúrgica/microbiologia , Suínos , Alicerces Teciduais/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA