Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 77
Filtrar
1.
J Electrocardiol ; 80: 166-173, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37467573

RESUMO

BACKGROUND: Electrocardiogram (ECG) interpretation training is a fundamental component of medical education across disciplines. However, the skill of interpreting ECGs is not universal among medical graduates, and numerous barriers and challenges exist in medical training and clinical practice. An evidence-based and widely accessible learning solution is needed. DESIGN: The EDUcation Curriculum Assessment for Teaching Electrocardiography (EDUCATE) Trial is a prospective, international, investigator-initiated, open-label, randomized controlled trial designed to determine the efficacy of self-directed and active-learning approaches of a web-based educational platform for improving ECG interpretation proficiency. Target enrollment is 1000 medical professionals from a variety of medical disciplines and training levels. Participants will complete a pre-intervention baseline survey and an ECG interpretation proficiency test. After completion, participants will be randomized into one of four groups in a 1:1:1:1 fashion: (i) an online, question-based learning resource, (ii) an online, lecture-based learning resource, (iii) an online, hybrid question- and lecture-based learning resource, or (iv) a control group with no ECG learning resources. The primary endpoint will be the change in overall ECG interpretation performance according to pre- and post-intervention tests, and it will be measured within and compared between medical professional groups. Secondary endpoints will include changes in ECG interpretation time, self-reported confidence, and interpretation accuracy for specific ECG findings. CONCLUSIONS: The EDUCATE Trial is a pioneering initiative aiming to establish a practical, widely available, evidence-based solution to enhance ECG interpretation proficiency among medical professionals. Through its innovative study design, it tackles the currently unaddressed challenges of ECG interpretation education in the modern era. The trial seeks to pinpoint performance gaps across medical professions, compare the effectiveness of different web-based ECG content delivery methods, and create initial evidence for competency-based standards. If successful, the EDUCATE Trial will represent a significant stride towards data-driven solutions for improving ECG interpretation skills in the medical community.


Assuntos
Currículo , Eletrocardiografia , Humanos , Estudos Prospectivos , Eletrocardiografia/métodos , Aprendizagem , Avaliação Educacional , Competência Clínica , Ensino
2.
J Electrocardiol ; 62: 148-154, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32905894

RESUMO

AIM: To evaluate the interaction between sex and rate corrected QT interval (QTc) duration in normal subjects after drug-induced QT prolongation and in LQTS patients. METHODS: Semi-automated measurements were performed on 875 digital ECGs (200 normal subjects off drugs (100 females), 200 normal subjects on Moxifloxacin (100 females), 259 LQT1 patients (161 females), 183 LQT2 patients (100 females) and 33 LQT3 patients (15 females)). A sex specific coefficient was calculated in each group and was used to calculate group specific corrected QT intervals (QTci). RESULTS: The mean sex difference (female minus male) in QTci interval duration was 17 ms 95%CI(12.7; 21.3) in normal subjects, 19 ms (14.5; 23.5) on Moxifloxacin, and 13 ms (4.8; 21.2) in LQT1 patients. The mean difference was 2 ms (-7.9; 11.9) in LQT2 and - 5 ms (-32.2; 22.2) in LQT3 patients (p = 0.0067 for the group and sex interaction). In the subgroup of patients above 15 years and without beta blocker treatment, the sex effect (female minus male) on QTci interval duration was 17 ms (4.1; 29.9) in LQT1 patients. QTc duration was not different between sex in LQT2 and in LQT3 patients (mean difference - 3 ms (-21.6; 15.6) and 12 ms (-28.4; 52.4), respectively) (p = 0.0191 for group and sex interaction). CONCLUSIONS: The interaction between sex and QTc interval is preserved in type 1 LQTS and drug-induced QTc prolongation but blurred in type 2 LQTS. Further experimental studies are warranted to better understand the interaction of sexual hormones with malfunctioning KCNH2 encoded repolarizing potassium channel.


Assuntos
Eletrocardiografia , Síndrome do QT Longo , Antagonistas Adrenérgicos beta , Feminino , Humanos , Síndrome do QT Longo/diagnóstico , Masculino
3.
Am Heart J ; 200: 1-10, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29898835

RESUMO

BACKGROUND: Automated measurements of electrocardiographic (ECG) intervals by current-generation digital electrocardiographs are critical to computer-based ECG diagnostic statements, to serial comparison of ECGs, and to epidemiological studies of ECG findings in populations. A previous study demonstrated generally small but often significant systematic differences among 4 algorithms widely used for automated ECG in the United States and that measurement differences could be related to the degree of abnormality of the underlying tracing. Since that publication, some algorithms have been adjusted, whereas other large manufacturers of automated ECGs have asked to participate in an extension of this comparison. METHODS: Seven widely used automated algorithms for computer-based interpretation participated in this blinded study of 800 digitized ECGs provided by the Cardiac Safety Research Consortium. All tracings were different from the study of 4 algorithms reported in 2014, and the selected population was heavily weighted toward groups with known effects on the QT interval: included were 200 normal subjects, 200 normal subjects receiving moxifloxacin as part of an active control arm of thorough QT studies, 200 subjects with genetically proved long QT syndrome type 1 (LQT1), and 200 subjects with genetically proved long QT syndrome Type 2 (LQT2). RESULTS: For the entire population of 800 subjects, pairwise differences between algorithms for each mean interval value were clinically small, even where statistically significant, ranging from 0.2 to 3.6milliseconds for the PR interval, 0.1 to 8.1milliseconds for QRS duration, and 0.1 to 9.3milliseconds for QT interval. The mean value of all paired differences among algorithms was higher in the long QT groups than in normals for both QRS duration and QT intervals. Differences in mean QRS duration ranged from 0.2 to 13.3milliseconds in the LQT1 subjects and from 0.2 to 11.0milliseconds in the LQT2 subjects. Differences in measured QT duration (not corrected for heart rate) ranged from 0.2 to 10.5milliseconds in the LQT1 subjects and from 0.9 to 12.8milliseconds in the LQT2 subjects. CONCLUSIONS: Among current-generation computer-based electrocardiographs, clinically small but statistically significant differences exist between ECG interval measurements by individual algorithms. Measurement differences between algorithms for QRS duration and for QT interval are larger in long QT interval subjects than in normal subjects. Comparisons of population study norms should be aware of small systematic differences in interval measurements due to different algorithm methodologies, within-individual interval measurement comparisons should use comparable methods, and further attempts to harmonize interval measurement methodologies are warranted.


Assuntos
Algoritmos , Eletrocardiografia , Síndrome do QT Longo/diagnóstico , Síndrome de Romano-Ward/diagnóstico , Adulto , Precisão da Medição Dimensional , Eletrocardiografia/métodos , Eletrocardiografia/normas , Feminino , Sistema de Condução Cardíaco/diagnóstico por imagem , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Distribuição Aleatória , Processamento de Sinais Assistido por Computador
4.
J Electrocardiol ; 50(6): 833-840, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28985886

RESUMO

Although automated ECG analysis has been available for many years, there are some aspects which require to be re-assessed with respect to their value while newer techniques which are worthy of review are beginning to find their way into routine use. At the annual International Society of Computerized Electrocardiology conference held in April 2017, four areas in particular were debated. These were a) automated 12 lead resting ECG analysis; b) real time out of hospital ECG monitoring; c) ECG imaging; and d) single channel ECG rhythm interpretation. One speaker presented the positive aspects of each technique and another outlined the more negative aspects. Debate ensued. There were many positives set out for each technique but equally, more negative features were not in short supply, particularly for out of hospital ECG monitoring.


Assuntos
Automação , Diagnóstico por Computador , Eletrocardiografia , Processamento de Sinais Assistido por Computador , Humanos , Sociedades Médicas
5.
J Electrocardiol ; 48(6): 1088-98, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26422547

RESUMO

At the April, 2015 International Society for Computerized Electrocardiology (ISCE) Annual Conference in San Jose, CA, a special session entitled Remembering Ron & Rory was held to pay tribute to the extraordinary work and lives of two experts in electrocardiology. The session was well attended by conference attendees, Childers' family members and friends, and additional colleagues who traveled to San Jose solely to participate in this session. The purpose of the present paper is to document the spirit of this special session as faithfully as possible using the words of the session speakers.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/história , Cardiologia/história , Eletrocardiografia/história , História do Século XX , História do Século XXI , Humanos , Estados Unidos
6.
Am Heart J ; 167(2): 150-159.e1, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24439975

RESUMO

BACKGROUND AND PURPOSE: Automated measurements of electrocardiographic (ECG) intervals are widely used by clinicians for individual patient diagnosis and by investigators in population studies. We examined whether clinically significant systematic differences exist in ECG intervals measured by current generation digital electrocardiographs from different manufacturers and whether differences, if present, are dependent on the degree of abnormality of the selected ECGs. METHODS: Measurements of RR interval, PR interval, QRS duration, and QT interval were made blindly by 4 major manufacturers of digital electrocardiographs used in the United States from 600 XML files of ECG tracings stored in the US FDA ECG warehouse and released for the purpose of this study by the Cardiac Safety Research Consortium. Included were 3 groups based on expected QT interval and degree of repolarization abnormality, comprising 200 ECGs each from (1) placebo or baseline study period in normal subjects during thorough QT studies, (2) peak moxifloxacin effect in otherwise normal subjects during thorough QT studies, and (3) patients with genotyped variants of congenital long QT syndrome (LQTS). RESULTS: Differences of means between manufacturers were generally small in the normal and moxifloxacin subjects, but in the LQTS patients, differences of means ranged from 2.0 to 14.0 ms for QRS duration and from 0.8 to 18.1 ms for the QT interval. Mean absolute differences between algorithms were similar for QRS duration and QT intervals in the normal and in the moxifloxacin subjects (mean ≤6 ms) but were significantly larger in patients with LQTS. CONCLUSIONS: Small but statistically significant group differences in mean interval and duration measurements and means of individual absolute differences exist among automated algorithms of widely used, current generation digital electrocardiographs. Measurement differences, including QRS duration and the QT interval, are greatest for the most abnormal ECGs.


Assuntos
Algoritmos , Eletrocardiografia/instrumentação , Sistema de Condução Cardíaco/fisiologia , Frequência Cardíaca/fisiologia , Processamento de Sinais Assistido por Computador , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
7.
J Nucl Cardiol ; 21(1): 192-220, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24374980

RESUMO

The American College of Cardiology Foundation along with key specialty and subspecialty societies, conducted an appropriate use review of common clinical presentations for stable ischemic heart disease (SIHD) to consider use of stress testing and anatomic diagnostic procedures. This document reflects an updating of the prior Appropriate Use Criteria (AUC) published for radionuclide imaging (RNI), stress echocardiography (Echo), calcium scoring, coronary computed tomography angiography (CCTA), stress cardiac magnetic resonance (CMR), and invasive coronary angiography for SIHD. This is in keeping with the commitment to revise and refine the AUC on a frequent basis. A major innovation in this document is the rating of tests side by side for the same indication. The side-by-side rating removes any concerns about differences in indication or interpretation stemming from prior use of separate documents for each test. However, the ratings were explicitly not competitive rankings due to the limited availability of comparative evidence, patient variability, and range of capabilities available in any given local setting. The indications for this review are limited to the detection and risk assessment of SIHD and were drawn from common applications or anticipated uses, as well as from current clinical practice guidelines. Eighty clinical scenarios were developed by a writing committee and scored by a separate rating panel on a scale of 1-9, to designate Appropriate, May Be Appropriate, or Rarely Appropriate use following a modified Delphi process following the recently updated AUC development methodology. The use of some modalities of testing in the initial evaluation of patients with symptoms representing ischemic equivalents, newly diagnosed heart failure, arrhythmias, and syncope was generally found to be Appropriate or May Be Appropriate, except in cases where low pre-test probability or low risk limited the benefit of most testing except exercise electrocardiogram (ECG). Testing for the evaluation of new or worsening symptoms following a prior test or procedure was found to be Appropriate. In addition, testing was found to be Appropriate or May Be Appropriate for patients within 90 days of an abnormal or uncertain prior result. Pre-operative testing was rated Appropriate or May Be Appropriate only for patients who had poor functional capacity and were undergoing vascular or intermediate risk surgery with 1 or more clinical risk factors or an organ transplant. The exercise ECG was suggested as an Appropriate test for cardiac rehabilitation clearance or for exercise prescription purposes. Testing in asymptomatic patients was generally found to be Rarely Appropriate, except for calcium scoring and exercise testing in intermediate and high-risk individuals and either stress or anatomic imaging in higher-risk individuals, which were all rated as May Be Appropriate. All modalities of follow-up testing after a prior test or percutaneous coronary intervention (PCI) within 2 years and within 5 years after coronary artery bypass graft (CABG) in the absence of new symptoms were rated Rarely Appropriate. Pre-operative testing for patients with good functional capacity, prior normal testing within 1 year, or prior to low-risk surgery also were found to be Rarely Appropriate. Imaging for an exercise prescription or prior to the initiation of cardiac rehabilitation was Rarely Appropriate except for cardiac rehabilitation clearance for heart failure patients.


Assuntos
Cardiologia/normas , Angiografia Coronária/normas , Isquemia Miocárdica/terapia , Adulto , Idoso , Algoritmos , American Heart Association , Tomada de Decisões , Exercício Físico , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Segurança do Paciente , Medição de Risco , Sociedades Médicas , Resultado do Tratamento , Estados Unidos
8.
Ann Noninvasive Electrocardiol ; 19(5): 412-25, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25262661

RESUMO

The electrocardiogram (ECG) is the most widely used imaging tool helping in diagnosis and initial management of patients presenting with symptoms compatible with acute coronary syndrome. Acute ischemia affects the configuration of the QRS complexes, the ST segments and the T waves. The ECG should be read along with the clinical assessment of the patient. ST segment elevation (and ST depression in leads V1 -V3 ) in patients with active symptoms usually indicates acute occlusion of an epicardial artery with ongoing transmural ischemia. These patients should be triaged for emergent reperfusion therapy per current guidelines. However, many patients have ST segment elevation secondary to nonischemic causes. ST depression in leads other than V1 -V3 usually are indicative of subendocardial ischemia secondary to subocclusion of the epicardial artery, distal embolization to small arteries or spasm supply/demand mismatch. ST depression may also be secondary to nonischemic etiologies, such as left ventricular hypertrophy, cardiomyopathies, etc. Knowing the clinical scenario, comparison to previous ECG and subsequent ECGs (in cases that there are changes in the quality or severity of symptoms) may add in the diagnosis and interpretation in difficult cases. This review addresses the different ECG patterns, typically seen in patients with active symptoms, after resolution of symptoms and the significance of such changes when seen in asymptomatic patients.


Assuntos
Síndrome Coronariana Aguda/diagnóstico , Eletrocardiografia , Síndrome Coronariana Aguda/fisiopatologia , Cateterismo Cardíaco , Consenso , Humanos , Medição de Risco , Triagem
9.
Ann Noninvasive Electrocardiol ; 19(5): 426-41, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25262662

RESUMO

BACKGROUND: For many years was considered that negative T wave in ischemic heart disease represents ischemia and for many authors located in subepicardial area. METHODS: We performed a review based in the literature and in the experience of the authors commenting the real significance of the presence of negative T wave in patients with ischemic heart disease. RESULTS: The negative T wave may be of primary or secondary type. Negative T wave observed in ischemic heart disease are of primary origin, therefore not a consequence of abnormal repolarization pattern. The negative T wave of ischemic origin presents the following characteristics: (1) are symmetrical and of variable deepness; (2) present mirror patterns; (3) starts in the second part of repolarization; and (4) may be accompanied by positive or negative U wave. The negative T wave of ischemic origin may be seen in the following clinical settings: (1) postmyocardial infarction due to a window effect of necrotic zone and (2) as a consequence of reperfusion in case of aborted MI when the artery has opened spontaneously, or after fibrinolysis, PCI, or coronary spasm. CONCLUSION: Acute ongoing ischemia do not cause negative T wave. This pattern appears when the ongoing ischemia is vanishing or in the chronic phase. In all these cases the cause of negative T wave is not located in the subepicardial area. Furthermore, positive exercise testing is expressed by ST depression never by isolated negative T wave. There are many circumstances that may present negative T wave outside ischemic heart disease and that have been discussed in this paper.


Assuntos
Eletrocardiografia , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Animais , Consenso , Circulação Coronária , Humanos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/fisiopatologia
10.
Cardiology ; 124(2): 108-15, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23428621

RESUMO

BACKGROUND: Nonsustained ventricular tachycardia (VT), frequent in unoperated severe mitral regurgitation (MR), confers mortality risk [sudden death (SD) and cardiac death (CD)]. The prognostic value of VT after mitral valve surgery (MVS) is unknown; we aimed to define this prognostic value and to assess its modulation by left (LV) and/or right (RV) ventricular ejection fraction (EF) for mortality after MVS. METHODS: In 57 patients (53% females, aged 58 ± 12 years) with severe MR prospectively followed before and after MVS, we performed 24-hour ambulatory electrocardiograms approximately annually. LVEF and RVEF were determined within 1 year after MVS by radionuclide cineangiography. RESULTS: During 9.52 ± 3.49 endpoint-free follow-up years, late postoperative CD occurred in 11 patients (7 SD, 4 heart failures). In univariable analysis, >1 VT episode after MVS predicted SD (p < 0.01) and CD (SD or heart failure; p < 0.04). Subnormal postoperative RVEF predicted CD (p < 0.04). When adjusted for preoperative age, gender, etiology or antiarrhythmics, both postoperative VT and RVEF predicted CD (p ≤ 0.05). When postoperative VT and RVEF were both in the multivariable model, only subnormal RVEF predicted CD (p < 0.04). Among those with normal RVEF, VT >1 episode predicted SD (p = 0.03). CONCLUSION: Postoperative VT and subnormal RVEF predict late postoperative deaths in nonischemic MR. Their assessment may aid patient management.


Assuntos
Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/mortalidade , Taquicardia Ventricular/mortalidade , Eletrocardiografia Ambulatorial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Prognóstico , Estudos Prospectivos , Volume Sistólico/fisiologia , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia
11.
Curr Probl Cardiol ; 48(10): 101924, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37394202

RESUMO

ECG interpretation is essential in modern medicine, yet achieving and maintaining competency can be challenging for healthcare professionals. Quantifying proficiency gaps can inform educational interventions for addressing these challenges. Medical professionals from diverse disciplines and training levels interpreted 30 12-lead ECGs with common urgent and nonurgent findings. Average accuracy (percentage of correctly identified findings), interpretation time per ECG, and self-reported confidence (rated on a scale of 0 [not confident], 1 [somewhat confident], or 2 [confident]) were evaluated. Among the 1206 participants, there were 72 (6%) primary care physicians (PCPs), 146 (12%) cardiology fellows-in-training (FITs), 353 (29%) resident physicians, 182 (15%) medical students, 84 (7%) advanced practice providers (APPs), 120 (10%) nurses, and 249 (21%) allied health professionals (AHPs). Overall, participants achieved an average overall accuracy of 56.4% ± 17.2%, interpretation time of 142 ± 67 seconds, and confidence of 0.83 ± 0.53. Cardiology FITs demonstrated superior performance across all metrics. PCPs had a higher accuracy compared to nurses and APPs (58.1% vs 46.8% and 50.6%; P < 0.01), but a lower accuracy than resident physicians (58.1% vs 59.7%; P < 0.01). AHPs outperformed nurses and APPs in every metric and showed comparable performance to resident physicians and PCPs. Our findings highlight significant gaps in the ECG interpretation proficiency among healthcare professionals.


Assuntos
Competência Clínica , Eletrocardiografia , Humanos , Atenção à Saúde
12.
Am Heart J ; 163(3): 365-71, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22424006

RESUMO

BACKGROUND: The Cardiac Safety Research Consortium (CSRC) provides both "learning" and blinded "testing" digital electrocardiographic (ECG) data sets from thorough QT (TQT) studies annotated for submission to the US Food and Drug Administration (FDA) to developers of ECG analysis technologies. This article reports the first results from a blinded testing data set that examines developer reanalysis of original sponsor-reported core laboratory data. METHODS: A total of 11,925 anonymized ECGs including both moxifloxacin and placebo arms of a parallel-group TQT in 181 subjects were blindly analyzed using a novel ECG analysis algorithm applying intelligent automation. Developer-measured ECG intervals were submitted to CSRC for unblinding, temporal reconstruction of the TQT exposures, and statistical comparison to core laboratory findings previously submitted to FDA by the pharmaceutical sponsor. Primary comparisons included baseline-adjusted interval measurements, baseline- and placebo-adjusted moxifloxacin QTcF changes (ddQTcF), and associated variability measures. RESULTS: Developer and sponsor-reported baseline-adjusted data were similar with average differences <1 ms for all intervals. Both developer- and sponsor-reported data demonstrated assay sensitivity with similar ddQTcF changes. Average within-subject SD for triplicate QTcF measurements was significantly lower for developer- than sponsor-reported data (5.4 and 7.2 ms, respectively; P < .001). CONCLUSION: The virtually automated ECG algorithm used for this analysis produced similar yet less variable TQT results compared with the sponsor-reported study, without the use of a manual core laboratory. These findings indicate that CSRC ECG data sets can be useful for evaluating novel methods and algorithms for determining drug-induced QT/QTc prolongation. Although the results should not constitute endorsement of specific algorithms by either CSRC or FDA, the value of a public domain digital ECG warehouse to provide prospective, blinded comparisons of ECG technologies applied for QT/QTc measurement is illustrated.


Assuntos
Algoritmos , Automação/instrumentação , Compostos Aza/uso terapêutico , Eletrocardiografia/métodos , Síndrome do QT Longo/diagnóstico , Quinolinas/uso terapêutico , Anti-Infecciosos/uso terapêutico , Método Duplo-Cego , Eletrocardiografia/efeitos dos fármacos , Fluoroquinolonas , Seguimentos , Humanos , Síndrome do QT Longo/tratamento farmacológico , Síndrome do QT Longo/fisiopatologia , Moxifloxacina , Estudos Prospectivos , Reprodutibilidade dos Testes
13.
J Electrocardiol ; 45(5): 500-4, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22809574

RESUMO

In this study, we consider the proposition that the criteria for the electrocardiographic (ECG) diagnosis of left bundle-branch block (LBBB) be revised, a proposition born from analysis of results of cardiac resynchronization therapy trials. The various ECG definitions for LBBB (or lack thereof) used in these trials are reviewed as are the results of the analysis of ECGs from patients with left ventricular conduction disturbances by Grant and Dodge (Am J Med. 1956;20:834-852) and the criteria for the ECG diagnosis of LBBB recommended by the World Health Organization and the International Society and Federation for Cardiology in 1985. These criteria stress that the QRS complex be notched or slurred, that the initial portion of the QRS complex (the "septal Q waves") be absent, and that the QRS duration be at least 120 milliseconds in duration. This is in contrast to the recent suggestion that the QRS complex has a minimum duration of 130 to 140 milliseconds. We conclude that the criteria for the ECG diagnosis of LBBB should be standardized to that recommended by the World Health Organization and International Society and Federation for Cardiology with retention of the minimum duration of 120 milliseconds and that the QRS prolongation should be not be gradual. However, we also conclude that in patients with LBBB being considered for cardiac resynchronization therapy, the duration of the QRS complex should be at least 130 milliseconds.


Assuntos
Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/fisiopatologia , Eletrocardiografia/normas , Ventrículos do Coração/fisiopatologia , Ensaios Clínicos como Assunto , Diagnóstico Diferencial , Humanos , Sociedades Médicas , Organização Mundial da Saúde
14.
J Electrocardiol ; 45(6): 690-2, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22999491

RESUMO

The Cardiac Safety Research Consortium (CSRC) ECG database was initiated to foster research using anonymized, XML-formatted, digitized ECGs with corresponding descriptive variables from placebo- and positive-control arms of thorough QT studies submitted to the US Food and Drug Administration (FDA) by pharmaceutical sponsors. The database can be expanded to other data that are submitted directly to CSRC from other sources, and currently includes digitized ECGs from patients with genotyped varieties of congenital long-QT syndrome; this congenital long-QT database is also linked to ambulatory electrocardiograms stored in the Telemetric and Holter ECG Warehouse (THEW). Thorough QT data sets are available from CSRC for unblinded development of algorithms for analysis of repolarization and for blinded comparative testing of algorithms developed for the identification of moxifloxacin, as used as a positive control in thorough QT studies. Policies and procedures for access to these data sets are available from CSRC, which has developed tools for statistical analysis of blinded new algorithm performance. A recently approved CSRC project will create a data set for blinded analysis of automated ECG interval measurements, whose initial focus will include comparison of four of the major manufacturers of automated electrocardiographs in the United States. CSRC welcomes application for use of the ECG database for clinical investigation.


Assuntos
Bases de Dados Factuais/estatística & dados numéricos , Eletrocardiografia/estatística & dados numéricos , Registros de Saúde Pessoal , Síndrome do QT Longo/diagnóstico , Síndrome do QT Longo/epidemiologia , Segurança do Paciente/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , Sistemas de Gerenciamento de Base de Dados/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Estados Unidos/epidemiologia
16.
Am Heart J ; 160(6): 1023-8, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21146653

RESUMO

This document examines the formation, structure, and principles guiding the use of electrocardiogram (ECG) data sets obtained during thorough QT studies that have been derived from the ECG Warehouse of the Cardiac Safety Research Consortium (CSRC). These principles are designed to preserve the fairness and public interest of access to these data, commensurate with the mission of the CSRC. The data sets comprise anonymized XML formatted digitized ECGs and descriptive variables from placebo and positive control arms of individual studies previously submitted on a proprietary basis to the US Food and Drug Administration by pharmaceutical sponsors. Sponsors permit the release of these studies into the public domain through the CSRC on behalf of the Food and Drug Administration's Critical Path Initiative and public health interest. For algorithm research protocols submitted to and approved by CSRC, unblinded "training" ECG data sets are provided for algorithm development and for initial evaluation, whereas separate blinded "testing" data sets are used for formal algorithm evaluation in cooperation with the CSRC according to methods detailed in this document.


Assuntos
Algoritmos , Pesquisa Biomédica , Eletrocardiografia/métodos , Síndrome do QT Longo/fisiopatologia , Humanos , Processamento de Sinais Assistido por Computador , Estados Unidos
18.
J Card Fail ; 20(2): 65-90, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24556531
19.
Circulation ; 115(10): 1325-32, 2007 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-17322456

RESUMO

This statement provides a concise list of diagnostic terms for ECG interpretation that can be shared by students, teachers, and readers of electrocardiography. This effort was motivated by the existence of multiple automated diagnostic code sets containing imprecise and overlapping terms. An intended outcome of this statement list is greater uniformity of ECG diagnosis and a resultant improvement in patient care. The lexicon includes primary diagnostic statements, secondary diagnostic statements, modifiers, and statements for the comparison of ECGs. This diagnostic lexicon should be reviewed and updated periodically.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia/normas , Humanos , Cooperação Internacional , Sensibilidade e Especificidade , Processamento de Sinais Assistido por Computador , Estados Unidos
20.
Circulation ; 115(10): 1306-24, 2007 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-17322457

RESUMO

This statement examines the relation of the resting ECG to its technology. Its purpose is to foster understanding of how the modern ECG is derived and displayed and to establish standards that will improve the accuracy and usefulness of the ECG in practice. Derivation of representative waveforms and measurements based on global intervals are described. Special emphasis is placed on digital signal acquisition and computer-based signal processing, which provide automated measurements that lead to computer-generated diagnostic statements. Lead placement, recording methods, and waveform presentation are reviewed. Throughout the statement, recommendations for ECG standards are placed in context of the clinical implications of evolving ECG technology.


Assuntos
Arritmias Cardíacas/diagnóstico , Eletrocardiografia/normas , Processamento de Sinais Assistido por Computador , Eletrocardiografia/tendências , Previsões , Humanos , Cooperação Internacional , Sensibilidade e Especificidade , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA