Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
J Cardiovasc Magn Reson ; 26(1): 101040, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38522522

RESUMO

BACKGROUND: Late gadolinium enhancement (LGE) of the myocardium has significant diagnostic and prognostic implications, with even small areas of enhancement being important. Distinguishing between definitely normal and definitely abnormal LGE images is usually straightforward, but diagnostic uncertainty arises when reporters are not sure whether the observed LGE is genuine or not. This uncertainty might be resolved by repetition (to remove artifact) or further acquisition of intersecting images, but this must take place before the scan finishes. Real-time quality assurance by humans is a complex task requiring training and experience, so being able to identify which images have an intermediate likelihood of LGE while the scan is ongoing, without the presence of an expert is of high value. This decision-support could prompt immediate image optimization or acquisition of supplementary images to confirm or refute the presence of genuine LGE. This could reduce ambiguity in reports. METHODS: Short-axis, phase-sensitive inversion recovery late gadolinium images were extracted from our clinical cardiac magnetic resonance (CMR) database and shuffled. Two, independent, blinded experts scored each individual slice for "LGE likelihood" on a visual analog scale, from 0 (absolute certainty of no LGE) to 100 (absolute certainty of LGE), with 50 representing clinical equipoise. The scored images were split into two classes-either "high certainty" of whether LGE was present or not, or "low certainty." The dataset was split into training, validation, and test sets (70:15:15). A deep learning binary classifier based on the EfficientNetV2 convolutional neural network architecture was trained to distinguish between these categories. Classifier performance on the test set was evaluated by calculating the accuracy, precision, recall, F1-score, and area under the receiver operating characteristics curve (ROC AUC). Performance was also evaluated on an external test set of images from a different center. RESULTS: One thousand six hundred and forty-five images (from 272 patients) were labeled and split at the patient level into training (1151 images), validation (247 images), and test (247 images) sets for the deep learning binary classifier. Of these, 1208 images were "high certainty" (255 for LGE, 953 for no LGE), and 437 were "low certainty". An external test comprising 247 images from 41 patients from another center was also employed. After 100 epochs, the performance on the internal test set was accuracy = 0.94, recall = 0.80, precision = 0.97, F1-score = 0.87, and ROC AUC = 0.94. The classifier also performed robustly on the external test set (accuracy = 0.91, recall = 0.73, precision = 0.93, F1-score = 0.82, and ROC AUC = 0.91). These results were benchmarked against a reference inter-expert accuracy of 0.86. CONCLUSION: Deep learning shows potential to automate quality control of late gadolinium imaging in CMR. The ability to identify short-axis images with intermediate LGE likelihood in real-time may serve as a useful decision-support tool. This approach has the potential to guide immediate further imaging while the patient is still in the scanner, thereby reducing the frequency of recalls and inconclusive reports due to diagnostic indecision.


Assuntos
Meios de Contraste , Aprendizado Profundo , Interpretação de Imagem Assistida por Computador , Valor Preditivo dos Testes , Humanos , Meios de Contraste/administração & dosagem , Reprodutibilidade dos Testes , Interpretação de Imagem Assistida por Computador/normas , Bases de Dados Factuais , Miocárdio/patologia , Masculino , Feminino , Imagem Cinética por Ressonância Magnética/normas , Pessoa de Meia-Idade , Cardiopatias/diagnóstico por imagem , Garantia da Qualidade dos Cuidados de Saúde/normas , Variações Dependentes do Observador , Idoso , Imageamento por Ressonância Magnética/normas
2.
BMC Med Imaging ; 22(1): 122, 2022 07 07.
Artigo em Inglês | MEDLINE | ID: mdl-35799139

RESUMO

BACKGROUND: To assess the feasibility of biventricular SAPPHIRE T1 mapping in vivo across field strengths using diastolic, systolic and dark-blood (DB) approaches. METHODS: 10 healthy volunteers underwent same-day non-contrast cardiovascular magnetic resonance at 1.5 Tesla (T) and 3 T. Left and right ventricular (LV, RV) T1 mapping was performed in the basal, mid and apical short axis using 4-variants of SAPPHIRE: diastolic, systolic, 0th and 2nd order motion-sensitized DB and conventional modified Look-Locker inversion recovery (MOLLI). RESULTS: LV global myocardial T1 times (1.5 T then 3 T results) were significantly longer by diastolic SAPPHIRE (1283 ± 11|1600 ± 17 ms) than any of the other SAPPHIRE variants: systolic (1239 ± 9|1595 ± 13 ms), 0th order DB (1241 ± 10|1596 ± 12) and 2nd order DB (1251 ± 11|1560 ± 20 ms, all p < 0.05). In the mid septum MOLLI and diastolic SAPPHIRE exhibited significant T1 signal contamination (longer T1) at the blood-myocardial interface not seen with the other 3 SAPPHIRE variants (all p < 0.025). Additionally, systolic, 0th order and 2nd order DB SAPPHIRE showed narrower dispersion of myocardial T1 times across the mid septum when compared to diastolic SAPPHIRE (interquartile ranges respectively: 25 ms, 71 ms, 73 ms vs 143 ms, all p < 0.05). RV T1 mapping was achievable using systolic, 0th and 2nd order DB SAPPHIRE but not with MOLLI or diastolic SAPPHIRE. All 4 SAPPHIRE variants showed excellent re-read reproducibility (intraclass correlation coefficients 0.953 to 0.996). CONCLUSION: These small-scale preliminary healthy volunteer data suggest that DB SAPPHIRE has the potential to reduce partial volume effects at the blood-myocardial interface, and that systolic SAPPHIRE could be a feasible solution for right ventricular T1 mapping. Further work is needed to understand the robustness of these sequences and their potential clinical utility.


Assuntos
Óxido de Alumínio , Interpretação de Imagem Assistida por Computador , Frequência Cardíaca , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Valor Preditivo dos Testes , Reprodutibilidade dos Testes
3.
Circulation ; 141(16): 1282-1291, 2020 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-32078380

RESUMO

BACKGROUND: Myocardial perfusion reflects the macro- and microvascular coronary circulation. Recent quantitation developments using cardiovascular magnetic resonance perfusion permit automated measurement clinically. We explored the prognostic significance of stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR, the ratio of stress to rest MBF). METHODS: A 2-center study of patients with both suspected and known coronary artery disease referred clinically for perfusion assessment. Image analysis was performed automatically using a novel artificial intelligence approach deriving global and regional stress and rest MBF and MPR. Cox proportional hazard models adjusting for comorbidities and cardiovascular magnetic resonance parameters sought associations of stress MBF and MPR with death and major adverse cardiovascular events (MACE), including myocardial infarction, stroke, heart failure hospitalization, late (>90 day) revascularization, and death. RESULTS: A total of 1049 patients were included with a median follow-up of 605 (interquartile range, 464-814) days. There were 42 (4.0%) deaths and 188 MACE in 174 (16.6%) patients. Stress MBF and MPR were independently associated with both death and MACE. For each 1 mL·g-1·min-1 decrease in stress MBF, the adjusted hazard ratios for death and MACE were 1.93 (95% CI, 1.08-3.48, P=0.028) and 2.14 (95% CI, 1.58-2.90, P<0.0001), respectively, even after adjusting for age and comorbidity. For each 1 U decrease in MPR, the adjusted hazard ratios for death and MACE were 2.45 (95% CI, 1.42-4.24, P=0.001) and 1.74 (95% CI, 1.36-2.22, P<0.0001), respectively. In patients without regional perfusion defects on clinical read and no known macrovascular coronary artery disease (n=783), MPR remained independently associated with death and MACE, with stress MBF remaining associated with MACE only. CONCLUSIONS: In patients with known or suspected coronary artery disease, reduced MBF and MPR measured automatically inline using artificial intelligence quantification of cardiovascular magnetic resonance perfusion mapping provides a strong, independent predictor of adverse cardiovascular outcomes.


Assuntos
Inteligência Artificial , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Angiografia por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Idoso , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
J Cardiovasc Magn Reson ; 23(1): 37, 2021 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-33731141

RESUMO

BACKGROUND: Adenosine stress perfusion cardiovascular magnetic resonance (CMR) is commonly used in the assessment of patients with suspected ischaemia. Accepted protocols recommend administration of adenosine at a dose of 140 µg/kg/min increased up to 210 µg/kg/min if required. Conventionally, adequate stress has been assessed using change in heart rate, however, recent studies have suggested that these peripheral measurements may not reflect hyperaemia and can be blunted, in particular, in patients with heart failure. This study looked to compare stress myocardial blood flow (MBF) and haemodynamic response with different dosing regimens of adenosine during stress perfusion CMR in patients and healthy controls. METHODS: 20 healthy adult subjects were recruited as controls to compare 3 adenosine perfusion protocols: standard dose (140 µg/kg/min for 4 min), high dose (210 µg/kg/min for 4 min) and long dose (140 µg/kg/min for 8 min). 60 patients with either known or suspected coronary artery disease (CAD) or with heart failure and different degrees of left ventricular (LV) dysfunction underwent adenosine stress with standard and high dose adenosine within the same scan. All studies were carried out on a 3 T CMR scanner. Quantitative global myocardial perfusion and haemodynamic response were compared between doses. RESULTS: In healthy controls, no significant difference was seen in stress MBF between the 3 protocols. In patients with known or suspected CAD, and those with heart failure and mild systolic impairment (LV ejection fraction (LVEF) ≥ 40%) no significant difference was seen in stress MBF between standard and high dose adenosine. In those with LVEF < 40%, there was a significantly higher stress MBF following high dose adenosine compared to standard dose (1.33 ± 0.46 vs 1.10 ± 0.47 ml/g/min, p = 0.004). Non-responders to standard dose adenosine (defined by an increase in heart rate (HR) < 10 bpm) had a significantly higher stress HR following high dose (75 ± 12 vs 70 ± 14 bpm, p = 0.034), but showed no significant difference in stress MBF. CONCLUSIONS: Increasing adenosine dose from 140 to 210 µg/kg/min leads to increased stress MBF in patients with significantly impaired LV systolic function. Adenosine dose in clinical perfusion assessment may need to be increased in these patients.


Assuntos
Adenosina/administração & dosagem , Circulação Coronária , Hiperemia/fisiopatologia , Imagem Cinética por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Vasodilatadores/administração & dosagem , Disfunção Ventricular Esquerda/diagnóstico por imagem , Função Ventricular Esquerda , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Volume Sistólico , Sístole , Disfunção Ventricular Esquerda/fisiopatologia
5.
J Cardiovasc Magn Reson ; 23(1): 82, 2021 06 17.
Artigo em Inglês | MEDLINE | ID: mdl-34134696

RESUMO

BACKGROUND: Quantitative myocardial perfusion mapping using cardiovascular magnetic resonance (CMR) is validated for myocardial blood flow (MBF) estimation in native vessel coronary artery disease (CAD). Following coronary artery bypass graft (CABG) surgery, perfusion defects are often detected in territories supplied by the left internal mammary artery (LIMA) graft, but their interpretation and subsequent clinical management is variable. METHODS: We assessed myocardial perfusion using quantitative CMR perfusion mapping in 38 patients with prior CABG surgery, all with angiographically-proven patent LIMA grafts to the left anterior descending coronary artery (LAD) and no prior infarction in the LAD territory. Factors potentially determining MBF in the LIMA-LAD myocardial territory, including the impact of delayed contrast arrival through the LIMA graft were evaluated. RESULTS: Perfusion defects were reported on blinded visual analysis in the LIMA-LAD territory in 27 (71%) cases, despite LIMA graft patency and no LAD infarction. Native LAD chronic total occlusion (CTO) was a strong independent predictor of stress MBF (B = - 0.41, p = 0.014) and myocardial perfusion reserve (MPR) (B = - 0.56, p = 0.005), and was associated with reduced stress MBF in the basal (1.47 vs 2.07 ml/g/min; p = 0.002) but not the apical myocardial segments (1.52 vs 1.87 ml/g/min; p = 0.057). Extending the maximum arterial time delay incorporated in the quantitative perfusion algorithm, resulted only in a small increase (3.4%) of estimated stress MBF. CONCLUSIONS: Perfusion defects are frequently detected in LIMA-LAD subtended territories post CABG despite LIMA patency. Although delayed contrast arrival through LIMA grafts causes a small underestimation of MBF, perfusion defects are likely to reflect true reductions in myocardial blood flow, largely due to proximal native LAD disease.


Assuntos
Ponte de Artéria Coronária , Artéria Torácica Interna , Ponte de Artéria Coronária/efeitos adversos , Humanos , Isquemia , Espectroscopia de Ressonância Magnética , Artéria Torácica Interna/diagnóstico por imagem , Artéria Torácica Interna/cirurgia , Perfusão , Valor Preditivo dos Testes
6.
Magn Reson Med ; 84(5): 2788-2800, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32378776

RESUMO

PURPOSE: Quantification of myocardial perfusion has the potential to improve the detection of regional and global flow reduction. Significant effort has been made to automate the workflow, where one essential step is the arterial input function (AIF) extraction. Failure to accurately identify the left ventricle (LV) prevents AIF estimation required for quantification, therefore high detection accuracy is required. This study presents a robust LV detection method using the convolutional neural network (CNN). METHODS: CNN models were trained by assembling 25,027 scans (N = 12,984 patients) from three hospitals, seven scanners. Performance was evaluated using a hold-out test set of 5721 scans (N = 2805 patients). Model inputs were a time series of AIF images (2D+T). Two variations were investigated: (1) two classes (2CS) for background and foreground (LV mask), and (2) three classes (3CS) for background, LV, and RV. The final model was deployed on MRI scanners using the Gadgetron reconstruction software framework. RESULTS: Model loading on the MRI scanner took ~340 ms and applying the model took ~180 ms. The 3CS model successfully detected the LV in 99.98% of all test cases (1 failure out of 5721). The mean Dice ratio for 3CS was 0.87 ± 0.08 with 92.0% of all cases having Dice >0.75. The 2CS model gave a lower Dice ratio of 0.82 ± 0.22 (P < 1e-5). There was no significant difference in foot-time, peak-time, first-pass duration, peak value, and area-under-curve (P > .2) comparing automatically extracted AIF signals with signals from manually drawn contours. CONCLUSIONS: A CNN-based solution to detect the LV blood pool from the arterial input function image series was developed, validated, and deployed. A high LV detection accuracy of 99.98% was achieved.


Assuntos
Aprendizado Profundo , Ventrículos do Coração , Algoritmos , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Perfusão
7.
J Magn Reson Imaging ; 51(3): 693-711, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31111616

RESUMO

Cardiac MRI has become an indispensable imaging modality in the investigation of patients with suspected heart disease. It has emerged as the gold standard test for cardiac function, volumes, and mass and allows noninvasive tissue characterization and the assessment of myocardial perfusion. Quantitative MRI already has a key role in the development and incorporation of machine learning in clinical imaging, potentially offering major improvements in both workflow efficiency and diagnostic accuracy. As the clinical applications of a wide range of quantitative cardiac MRI techniques are being explored and validated, we are expanding our capabilities for earlier detection, monitoring, and risk stratification of disease, potentially guiding personalized management decisions in various cardiac disease models. In this article we review established and emerging quantitative techniques, their clinical applications, highlight novel advances, and appraise their clinical diagnostic potential. Level of Evidence: 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:693-711.


Assuntos
Cardiopatias , Imageamento por Ressonância Magnética , Coração/diagnóstico por imagem , Cardiopatias/diagnóstico por imagem , Humanos , Aprendizado de Máquina , Radiografia
8.
J Magn Reson Imaging ; 50(3): 756-762, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30684288

RESUMO

BACKGROUND: Cardiac MR stress perfusion remains a qualitative technique in clinical practice due to technical and postprocessing challenges. However, automated inline perfusion mapping now permits myocardial blood flow (MBF, ml/g/min) quantification on-the-fly without user input. PURPOSE: To investigate the diagnostic performance of this novel technique in detecting occlusive coronary artery disease (CAD) in patients scheduled to undergo coronary angiography. STUDY TYPE: Prospective, observational. SUBJECTS: Fifty patients with suspected CAD and 24 healthy volunteers. FIELD STRENGTH: 1.5T. SEQUENCE: "Dual" sequence multislice 2D saturation recovery. ASSESSMENT: All patients underwent cardiac MR with perfusion mapping and invasive coronary angiography; the healthy volunteers had MR with perfusion mapping alone. STATISTICAL TESTS: Comparison between numerical variables was performed using an independent t-test. Receiver operator characteristic (ROC) curves were generated for transmyocardial, endocardial stress MBF, and myocardial perfusion reserve (MPR, the stress:rest MBF ratio) to diagnose severe (>70%) stenoses as measured by 3D quantitative coronary angiography (QCA). ROC curves were compared by the method of DeLong et al. RESULTS: Compared with volunteers, patients had lower stress MBF and MPR even in vessels with <50% stenosis (2.00 vs. 3.08 ml/g/min, respectively). As stenosis severity increased (<50%, 50-70%, >70%), MBF and MPR decreased. To diagnose occlusive (>70%) CAD, endocardial and transmyocardial stress MBF were superior to MPR (area under the curve 0.92 [95% CI 0.86-0.97] vs. 0.90 [95% CI 0.84-0.95] and 0.80 [95% CI 0.72-0.87], respectively). An endocardial threshold of 1.31 ml/g/min provided a per-coronary artery sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 90%, 82%, 50%, and 98%, with a per-patient diagnostic performance of 100%, 66%, 57%, and 100%, respectively. DATA CONCLUSION: Perfusion mapping can diagnose occlusive CAD with high accuracy and, in particular, high sensitivity and NPV make it a potential "rule-out" test. LEVEL OF EVIDENCE: 1 Technical Efficacy Stage: 2 J. Magn. Reson. Imaging 2019;50:756-762.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Meios de Contraste , Vasos Coronários/diagnóstico por imagem , Feminino , Gadolínio , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sensibilidade e Especificidade
9.
Artigo em Inglês | MEDLINE | ID: mdl-39115498

RESUMO

BACKGROUND: Coronary microvascular function is impaired in patients with obesity, contributing to myocardial dysfunction and heart failure. Bariatric surgery decreases cardiovascular mortality and heart failure, but the mechanisms are unclear. OBJECTIVES: The authors studied the impact of bariatric surgery on coronary microvascular function in patients with obesity and its relationship with metabolic syndrome. METHODS: Fully automated quantitative perfusion cardiac magnetic resonance and metabolic markers were performed before and 6 months after bariatric surgery. RESULTS: Compared with age- and sex-matched healthy volunteers, 38 patients living with obesity had lower stress myocardial blood flow (MBF) (P = 0.001) and lower myocardial perfusion reserve (P < 0.001). A total of 27 participants underwent paired follow-up 6 months post-surgery. Metabolic abnormalities reduced significantly at follow-up including mean body mass index by 11 ± 3 kg/m2 (P < 0.001), glycated hemoglobin by 9 mmol/mol (Q1-Q3: 4-19 mmol/mol; P < 0.001), fasting insulin by 142 ± 131 pmol/L (P < 0.001), and hepatic fat fraction by 5.6% (2.6%-15.0%; P < 0.001). Stress MBF increased by 0.28 mL/g/min (-0.02 to 0.75 mL/g/min; P = 0.003) and myocardial perfusion reserve by 0.13 (-0.25 to 1.1; P = 0.036). The increase in stress MBF was lower in those with preoperative type 2 diabetes mellitus (0.1 mL/g/min [-0.09 to 0.46 mL/g/min] vs 0.75 mL/g/min [0.31-1.25 mL/g/min]; P = 0.002). Improvement in stress MBF was associated with reduction in fasting insulin (beta = -0.45 [95% CI: -0.05 to 0.90]; P = 0.03). CONCLUSIONS: Coronary microvascular function is impaired in patients with obesity, but can be improved significantly with bariatric surgery. Improvements in microvascular function are associated with improvements in insulin resistance but are attenuated in those with preoperative type 2 diabetes mellitus.

10.
Br J Cardiol ; 30(4): 41, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-39247420

RESUMO

To review the utility of cardiovascular magnetic resonance (CMR) in the management of hospital inpatients, we performed a retrospective review of all inpatient CMR scans performed over a six-month period at a tertiary referral cardiology centre. Patient demographics, indication for CMR imaging, results of the CMR scans and whether the results changed patient management were recorded. Change in management included medication changes, subsequent invasive procedures, or avoidance of such, and hospital discharge. Overall, 169 patients were included in the study cohort, 66% were male, mean age was 57.1 years. The most common indication for inpatient CMR was to investigate for cardiomyopathy (53% of patients). The most prevalent diagnosis post- CMR in our cohort was ischaemic heart disease, including ischaemic cardiomyopathy and coronary artery disease. There was a complete change in diagnosis or additional diagnosis found in 29% of patients following CMR. Overall, inpatient CMR led to a change in management in 77% of patients; the most common being changes to medication regimen. CMR was well tolerated in 99% of patients and image quality was diagnostic in 93% of cine scans performed. In conclusion, CMR is vital for the management of cardiology inpatients, having an impact that is at least as significant as in the management of outpatients.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA