Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Radiology ; 307(3): e221998, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36809218

RESUMO

Background Arterial spin labeling (ASL) MRI can be used to assess organ perfusion but has yet to be implemented for perfusion evaluation of the lung. Purpose To evaluate pseudo-continuous ASL (PCASL) MRI for the detection of acute pulmonary embolism (PE) and its potential as an alternative to CT pulmonary angiography (CTPA). Materials and Methods Between November 2020 and November 2021, 97 patients (median age, 61 years; 48 women) with suspected PE were enrolled in this prospective study. PCASL MRI was performed within a 72-hour period following CTPA under free-breathing conditions and included three orthogonal planes. The pulmonary trunk was labeled during systole, and the image was acquired during diastole of the subsequent cardiac cycle. Additionally, multisection, coronal, balanced, steady-state free-precession imaging was carried out. Two radiologists blindly assessed overall image quality, artifacts, and diagnostic confidence (five-point Likert scale, 5 = best). Patients were categorized as positive or negative for PE, and a lobe-wise assessment in PCASL MRI and CTPA was conducted. Sensitivity and specificity were calculated on a patient level with the final clinical diagnosis serving as the reference standard. Interchangeability between MRI and CTPA was also tested with use of an individual equivalence index (IEI). Results PCASL MRI was performed successfully in all patients with high scores for image quality, artifact, and diagnostic confidence (κ ≥ .74). Of the 97 patients, 38 were positive for PE. PCASL MRI depicted PE correctly in 35 of 38 patients with three false-positive and three false-negative findings, resulting in a sensitivity of 35 of 38 patients (92% [95% CI: 79, 98]) and a specificity of 56 of 59 patients (95% [95% CI: 86, 99]). Interchangeability analysis revealed an IEI of 2.6% (95% CI: 1.2, 3.8). Conclusion Free-breathing pseudo-continuous arterial spin labeling MRI depicted abnormal lung perfusion caused by acute pulmonary embolism and may be useful as a contrast material-free alternative to CT pulmonary angiography for selected patients. German Clinical Trials Register no. DRKS00023599 © RSNA, 2023.


Assuntos
Imageamento por Ressonância Magnética , Embolia Pulmonar , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Embolia Pulmonar/diagnóstico , Respiração , Meios de Contraste , Marcadores de Spin
2.
World J Urol ; 40(6): 1455-1461, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35357510

RESUMO

PURPOSE: Purpose of this study is to evaluate the diagnostic accuracy of quantitative T2/ADC values in differentiating between PCa and lesions showing non-specific inflammatory infiltrates and atrophy, features of chronic prostatitis, as the most common histologically proven differential diagnosis. METHODS: In this retrospective, single-center cohort study, we analyzed 55 patients suspected of PCa, who underwent mpMRI (3T) including quantitative T2 maps before robot-assisted mpMRI-TRUS fusion prostate biopsy. All prostate lesions were scored according to PI-RADS v2.1. Regions of interest (ROIs) were annotated in focal lesions and normal prostate tissue. Quantitative mpMRI values from T2 mapping and ADC were compared using two-tailed t tests. Receiver operating characteristic curves (ROCs) and cutoff were calculated to differentiate between PCa and chronic prostatitis. RESULTS: Focal lesions showed significantly lower ADC and T2 mapping values than normal prostate tissue (p < 0.001). PCa showed significantly lower ADC and T2 values than chronic prostatitis (p < 0.001). ROC analysis revealed areas under the receiver operating characteristic curves (AUCs) of 0.85 (95% CI 0.74-0.97) for quantitative ADC values and 0.84 (95% CI 0.73-0.96) for T2 mapping. A significant correlation between ADC and T2 values was observed (r = 0.70; p < 0.001). CONCLUSION: T2 mapping showed high diagnostic accuracy for differentiating between PCa and chronic prostatitis, comparable to the performance of ADC values.


Assuntos
Neoplasias da Próstata , Prostatite , Estudos de Coortes , Imagem de Difusão por Ressonância Magnética , Humanos , Biópsia Guiada por Imagem , Imageamento por Ressonância Magnética , Masculino , Próstata/diagnóstico por imagem , Próstata/patologia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Prostatite/diagnóstico por imagem , Prostatite/patologia , Estudos Retrospectivos
3.
J Chem Phys ; 157(16): 164705, 2022 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-36319417

RESUMO

We report on carbon monoxide desorption and oxidation induced by 400 nm femtosecond laser excitation on the O/Ru(0001) surface probed by time-resolved x-ray absorption spectroscopy (TR-XAS) at the carbon K-edge. The experiments were performed under constant background pressures of CO (6 × 10-8 Torr) and O2 (3 × 10-8 Torr). Under these conditions, we detect two transient CO species with narrow 2π* peaks, suggesting little 2π* interaction with the surface. Based on polarization measurements, we find that these two species have opposing orientations: (1) CO favoring a more perpendicular orientation and (2) CO favoring a more parallel orientation with respect to the surface. We also directly detect gas-phase CO2 using a mass spectrometer and observe weak signatures of bent adsorbed CO2 at slightly higher x-ray energies than the 2π* region. These results are compared to previously reported TR-XAS results at the O K-edge, where the CO background pressure was three times lower (2 × 10-8 Torr) while maintaining the same O2 pressure. At the lower CO pressure, in the CO 2π* region, we observed adsorbed CO and a distribution of OC-O bond lengths close to the CO oxidation transition state, with little indication of gas-like CO. The shift toward "gas-like" CO species may be explained by the higher CO exposure, which blocks O adsorption, decreasing O coverage and increasing CO coverage. These effects decrease the CO desorption barrier through dipole-dipole interaction while simultaneously increasing the CO oxidation barrier.

4.
J Magn Reson Imaging ; 52(6): 1767-1782, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32627293

RESUMO

BACKGROUND: Quantitative assessment of pulmonary blood flow and visualization of its temporal and spatial distribution without contrast media is of clinical significance. PURPOSE: To assess the potential of electrocardiogram (ECG)-triggered pseudocontinuous arterial spin labeling (PCASL) imaging with balanced steady-state free-precession (bSSFP) readout to measure lung perfusion under free-breathing (FB) conditions and to study temporal and spatial characteristics of pulmonary blood flow. STUDY TYPE: Prospective, observational. SUBJECTS: Fourteen volunteers; three patients with pulmonary embolism. FIELD STRENGTH/SEQUENCES: 1.5T, PCASL-bSSFP. ASSESSMENT: The pulmonary trunk was labeled during systole. The following examinations were performed: 1) FB and timed breath-hold (TBH) examinations with a postlabeling delay (PLD) of 1000 msec, and 2) TBH examinations with multiple PLDs (100-1500 msec). Scan-rescan measurements were performed in four volunteers and one patient. Images were registered and the perfusion was evaluated in large vessels, small vessels, and parenchyma. Mean structural similarity indices (MSSIM) was computed and time-to-peak (TTP) of parenchymal perfusion in multiple PLDs was evaluated. Image quality reading was performed with three independent blinded readers. STATISTICAL TESTS: Wilcoxon test to compare MSSIM, perfusion, and Likert scores. Spearman's correlation to correlate TTP and cardiac cycle duration. The repeatability coefficient (RC) and within-subject coefficient of variation (wCV) for scan-rescan measurements. Intraclass correlation coefficient (ICC) for interreader agreement. RESULTS: Image registration resulted in a significant (P < 0.05) increase of MSSIM. FB perfusion values were 6% higher than TBH (3.28 ± 1.09 vs. 3.10 ± 0.99 mL/min/mL). TTP was highly correlated with individuals' cardiac cycle duration (Spearman = 0.89, P < 0.001). RC and wCV were better for TBH than FB (0.13-0.19 vs. 0.47-1.54 mL/min/mL; 6-7 vs. 19-60%). Image quality was rated very good, with ICCs 0.71-0.89. DATA CONCLUSION: ECG-triggered PCASL-bSSFP imaging of the lung at 1.5T can provide very good image quality and quantitative perfusion maps even under FB. The course of labeled blood through the lung shows a strong dependence on the individuals' cardiac cycle duration. LEVEL OF EVIDENCE: 2 TECHNICAL EFFICACY STAGE: 2 J. MAGN. RESON. IMAGING 2020;52:1767-1782.


Assuntos
Imageamento por Ressonância Magnética , Circulação Pulmonar , Artérias , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Marcadores de Spin
5.
Phys Chem Chem Phys ; 21(31): 17142-17151, 2019 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-31339149

RESUMO

In this work we compute high-coverage hydrogen adsorption energies and geometries on the stepped platinum surfaces Pt(211) and Pt(533) which contain a (100)-step type and the Pt(221) and Pt(553) surface with a (111) step edge. We discuss these results in relation to ultra-high-vacuum temperature programmed desorption (TPD) data to elucidate the origin of the desorption features. Our results indicated that on surfaces with a (100)-step type, two distinct ranges of adsorption energy for the step and terrace are observed, which mirrors the TPD spectra for which we find a clear separation of the desorption peaks. For the (111) step type, the TPD spectra show much less separation of the step and terrace features, which we assign to the low individual adsorption energies for H atoms on this step edge. From our results we obtain a much clearer understanding of the surface-hydrogen bonding at high coverages and the origin of the different TPD features present for the two step types studied.


Assuntos
Teoria da Densidade Funcional , Hidrogênio/química , Platina/química , Adsorção , Cristalização , Ligação de Hidrogênio , Temperatura , Termodinâmica
6.
J Magn Reson Imaging ; 47(2): 459-467, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28594113

RESUMO

PURPOSE: To evaluate the feasibility of a self-gated free-breathing volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (CS) for contrast-enhanced multiphase liver MRI. MATERIALS AND METHODS: We identified 23 patients who underwent multiphase gadobutrol-enhanced liver magnetic resonance imaging (MRI) using 1) a prototype free-breathing VIBE sequence with respiratory self-gating and CS (VIBECS ), and 2) a standard breath-hold VIBE (VIBESTD ) on the same 1.5T scanner at two timepoints. VIBECS was continuously acquired for 128 seconds and a time-series of 16 timepoints was jointly reconstructed from the dataset. The unenhanced, arterial, portal-venous, and venous timepoints with the best image quality were selected and compared to the corresponding VIBESTD series serving as reference. Image quality was assessed qualitatively (image quality, sharpness, lesion conspicuity, vessel contrast, noise, motion/other artifacts; two readers independently; 5-point Likert scale; 5 = excellent) and quantitatively (vessel contrast [VC], coefficient-of-variation [CV]) Statistics were performed using Wilcoxon-sign-rank (ordinal) and paired t-test (continuous variables). RESULTS: Image quality and lesion conspicuity revealed no significant differences between the sequences (P ≥ 0.3). VIBESTD showed a tendency to higher motion artifacts (P ≥ 0.07). Image sharpness significantly increased in VIBECS as compared to VIBESTD (P ≤ 0.03). Arterial phase vessel contrast appeared significantly lower in VIBECS than in VIBESTD (P = 0.04). VIBECS showed reconstruction artifacts not present in VIBESTD (P = 0.001). Image noise was significantly lower in VIBECS than in VIBESTD (P ≤ 0.004). Arterial phase VC was significantly lower in VIBECS than in VIBESTD (P = 0.01). CV revealed no differences between sequences (P = 0.7). CONCLUSION: VIBECS is feasible for continuous free-breathing contrast-enhanced multiphase liver MRI, providing similar image quality and lesion conspicuity as VIBESTD . LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 3 J. Magn. Reson. Imaging 2018;47:459-467.


Assuntos
Meios de Contraste , Gadolínio DTPA , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Idoso , Idoso de 80 Anos ou mais , Artefatos , Suspensão da Respiração , Estudos de Viabilidade , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade
7.
Phys Rev Lett ; 116(13): 136101, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27081992

RESUMO

The interaction of platinum with water plays a key role in (electro)catalysis. Herein, we describe a combined theoretical and experimental study that resolves the preferred adsorption structure of water wetting the Pt(111)-step type with adjacent (111) terraces. Double stranded lines wet the step edge forming water tetragons with dissimilar hydrogen bonds within and between the lines. Our results qualitatively explain experimental observations of water desorption and impact our thinking of solvation at the Pt electrochemical interface.

8.
Phys Chem Chem Phys ; 18(5): 3416-22, 2016 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-26327406

RESUMO

Platinum is an active catalyst for a large number of (electro)chemical reactions in aqueous solution. The observed catalytic activities result from an interplay between the intrinsic adsorption properties of platinum surfaces and their interaction with the aqueous environment. Although water networks have been extensively studied on close-packed surfaces, little is known about high-coverage solvation environments around defects. Here, we report DFT calculations on medium- to high-coverage water adsorption structures near the (100) step edge on Pt(533). We find that isolated ring structures adjacent to step edges form hexagons or pentagons. For higher coverages, 6 possible adsorption structures with varying ring sizes along the step edge and almost identical adsorption energies are observed. From our results we conclude that the favorable interaction of the H-down oriented water molecules, adjacent to the step edge, with the step dipole plays an important role in the formation of these structures. Furthermore, our results explain why water networks on stepped surfaces originate at the step edges, and extend towards the adjacent terraces, in agreement with previous experiments. These results show how step edges act as anchoring points for water adsorption and suggest that solvation of defects might dominate water structures on real platinum surfaces.

9.
J Chem Phys ; 140(13): 134708, 2014 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-24712809

RESUMO

We report on density functional theory (DFT)-GGA (generalized gradient approximation) computed adsorption energetics of water and the water-related fragments OH, O, and H on stepped Pt surfaces in the low coverage limit. The Pt(100) step edge as encountered on Pt(533) shows increased binding for all species studied, while the Pt(110) step edge, as found on Pt(553) shows only significantly enhanced binding for O and OH. Comparing these results to ultra high vacuum experiments reveals that DFT can explain the main experimental trends semiquantitatively.

10.
J Am Chem Soc ; 135(38): 14329-38, 2013 Sep 25.
Artigo em Inglês | MEDLINE | ID: mdl-23980577

RESUMO

A surface structural preference for (1 0 0) terraces of fcc metals is displayed by many bond-breaking or bond-making reactions in electrocatalysis. Here, this phenomenon is explored in the electrochemical oxidation of dimethyl ether (DME) on platinum. The elementary C-O bond-breaking step is identified and clarified by combining information obtained from single-crystal experiments and density functional theory (DFT) calculations. Experiments on Pt(1 0 0), Pt(5 1 0), and Pt(10 1 0) surfaces show that the surface structure sensitivity is due to the bond-breaking step, which is unfavorable on step sites. DFT calculations suggest that the precursor for the bond-breaking step is a CHOC adsorbate that preferentially adsorbs on a square ensemble of four neighboring atoms on Pt(1 0 0) terraces, named as "the active site". Step sites fail to strongly adsorb CHOC and are, therefore, ineffective in breaking C-O bonds, resulting in a decrease in activity on surfaces with increasing step density. Our combined experimental and computational results allow the formulation of a new mechanism for the electro-oxidation of DME as well as a simple general formula for the activity of different surfaces toward electrocatalytic reactions that prefer (1 0 0) terrace active sites.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA