Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Radiographics ; 44(8): e230173, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38990776

RESUMO

T1-weighted (T1W) pulse sequences are an indispensable component of clinical protocols in abdominal MRI but usually require multiple breath holds (BHs) during the examination, which not all patients can sustain. Patient motion can affect the quality of T1W imaging so that key diagnostic information, such as intrinsic signal intensity and contrast enhancement image patterns, cannot be determined. Patient motion also has a negative impact on examination efficiency, as multiple acquisition attempts prolong the duration of the examination and often remain noncontributory. Techniques for mitigation of motion-related artifacts at T1W imaging include multiple arterial acquisitions within one BH; free breathing with respiratory gating or respiratory triggering; and radial imaging acquisition techniques, such as golden-angle radial k-space acquisition (stack-of-stars). While each of these techniques has inherent strengths and limitations, the selection of a specific motion-mitigation technique is based on several factors, including the clinical task under investigation, downstream technical ramifications, patient condition, and user preference. The authors review the technical principles of free-breathing motion mitigation techniques in abdominal MRI with T1W sequences, offer an overview of the established clinical applications, and outline the existing limitations of these techniques. In addition, practical guidance for abdominal MRI protocol strategies commonly encountered in clinical scenarios involving patients with limited BH abilities is rendered. Future prospects of free-breathing T1W imaging in abdominal MRI are also discussed. ©RSNA, 2024 See the invited commentary by Fraum and An in this issue.


Assuntos
Abdome , Artefatos , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Abdome/diagnóstico por imagem , Movimento (Física) , Aumento da Imagem/métodos , Técnicas de Imagem de Sincronização Respiratória/métodos
2.
J Comput Assist Tomogr ; 45(6): 877-887, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34469903

RESUMO

OBJECTIVE: To investigate in an anthropomorphic phantom study the accuracy of dual-energy computed tomography (DECT) techniques for fat quantification in comparison with magnetic resonance (MR) proton density fat fraction (PDFF) and single-energy computed tomography (SECT), using known fat content as reference standard. METHODS: Between August 2018 and November 2020, organic material-based cylinders, composed of mixtures of lean and fat tissues mimics, iodine, and iron, were constructed to simulate varying fat content levels (0%, 10%, 15%, 25%, 50%, 75%, and 100%) in a parenchymal organ and were embedded into an anthropomorphic phantom simulating 3 patient sizes (circumference, 91, 126, and 161 cm). The phantom was imaged with multiecho MR, DECT, and SECT. Magnetic resonance PDFF, DECT fat fraction, and computed tomography (CT) numbers (SECT polychromatic and DECT monochromatic data, virtual unenhanced images) were estimated. Performances of MR PDFF and CT techniques to detect differences in fat content were measured using the area under the curve (AUC). Noninferiority of each CT technique relative to MR PDFF was tested using a noninferiority margin of -0.1. RESULTS: MR PDFF, DECT 140 keV monochromatic data, and fat fraction most closely correlated with known fat content (R2 = 0.98, 0.98, and 0.96, respectively). Unlike SECT and all other DECT techniques, DECT fat fraction was not affected by presence of iodine (mean difference, 0.3%; 95% confidence interval [CI], -0.9% to 1.5%). Dual-energy computed tomography fat fraction showed noninferiority to MR PDFF in detecting differences of 5% in fat content in medium-sized phantoms (ΔAUC, -0.05; 95% CI, -0.08 to -0.01), and 7% in large (ΔAUC, -0.04; 95% CI, -0.0 to 0.00) or extralarge sized phantoms (ΔAUC, -0.02; 95% CI, -0.07 to 0.00). CONCLUSIONS: Dual-energy computed tomography fat fraction shows linear correlation with true fat content in the range up to 50% fat fraction. Dual-energy computed tomography fat fraction has comparable estimation error and shows noninferiority to MR PDFF in detecting small differences in fat content across different body sizes.


Assuntos
Tecido Adiposo/anatomia & histologia , Imageamento por Ressonância Magnética/métodos , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes
3.
Eur Radiol ; 30(12): 6933-6936, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32607631

RESUMO

KEY POINTS: • The COVID-19 crisis resulted in a variety of physical and mental health issues beyond the viral infection itself, as indicated by an increase in domestic violence.• Radiologists should be aware of typical intimate partner violence (IPV) injury patterns, actively ask potential IPV victims about the cause of injury, and be familiar with support systems for IPV victims of their institutions.• Emergency and radiology departments should review their protocols for identifying and supporting IPV victims, and train their staff to work together to implement these measures during and beyond the COVID-19 crisis.


Assuntos
Infecções por Coronavirus/diagnóstico , Serviço Hospitalar de Emergência , Violência por Parceiro Íntimo/psicologia , Pandemias , Pneumonia Viral/diagnóstico , Radiologistas , Betacoronavirus , COVID-19 , Infecções por Coronavirus/psicologia , Feminino , Humanos , Masculino , Pneumonia Viral/psicologia , SARS-CoV-2
4.
Eur Radiol ; 29(11): 5813-5822, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31020338

RESUMO

PURPOSE: To identify independent confounding variables of gadoxetate-enhanced hepatobiliary-phase liver MRI using multiple regression analysis. MATERIALS AND METHODS: The institutional review board generally approved retrospective analyses and all patients provided written informed consent. One hundred ten patients who underwent a standardized 3.0-T gadoxetate-enhanced liver MRI between November 2008 and June 2013 were retrospectively reviewed. The gadoxetate liver enhancement normalized to enhancement in the erector spinae muscle (relative signal enhancement, SE) was related to biochemical laboratory parameters and descriptive patient characteristics (patient age, body mass index) using non-parametric univariate correlation analysis followed by a multiple linear regression model. RESULTS: Using univariate statistics, relative SE was inversely correlated with patient age, ALP, AST, total bilirubin, gamma-glutamyltransferase, INR, model of end-stage liver disease score, and proportionally with albumin and hemoglobin (all p < 0.01). In a multiple regression analysis, total bilirubin (p = 0.001), serum albumin (p = 0.016), and patient age (p = 0.018) were independently correlated with relative liver SE (n = 110). CONCLUSION: A multiple regression analysis showed that high total bilirubin, low serum albumin, or advanced age was associated with low hepatobiliary-phase gadoxetate parenchymal liver enhancement. In these patients, the lower contrast-to-noise ratio might impair diagnostic evaluation of non-enhancing liver lesions (e.g., HCC, liver metastasis). KEY POINTS: • A multiple regression analysis identified independent confounding variables of hepatobiliary-phase gadoxetate liver enhancement. • High bilirubin, low albumin, or advanced age was associated with low enhancement. • Diagnostic evaluation might be hampered in these patients.


Assuntos
Bilirrubina/metabolismo , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/patologia , Albumina Sérica/metabolismo , Adulto , Idoso , Biomarcadores Tumorais/metabolismo , Meios de Contraste , Feminino , Gadolínio DTPA , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , gama-Glutamiltransferase/metabolismo
5.
Eur Radiol ; 29(1): 224-231, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-29943178

RESUMO

OBJECTIVES: To investigate patients' perception of the radiology service when the radiologist communicates the findings to patients. METHODS: After routine MRI, patients in group 1 (n = 101) were given the opportunity to discuss the findings with the radiologist. Patients in group 2 (n = 101) left the radiology department without any personal communication. Subsequently, by means of a questionnaire designed by an expert psychologist, both groups were asked regarding their anxiety, emotional attachment to the institute and subjective assessment of competence. RESULTS: Overall 76 % of all patients were concerned about their imaging findings without significant difference between both groups (p = 0.179). Significantly more patients in group 1 (81%) versus group 2 (14%; p < 0.001) perceived the opportunity to discuss their imaging findings with a radiologist to be a characteristic of a good radiology consultation. A larger number of patients in group 1 experienced significantly higher bonding and only wanted in the future to be examined in the department with communication (p = 0.001) (93%/75%). Significantly more patients in group 1 regarded the radiology department they attended as being more competent (mean score 4.72/4.09, p < 0.001). CONCLUSION: Direct communication of imaging findings from radiologists to patients after an MRI examination leads to increased confidence in the radiology service and higher bonding between the patient and radiologist. Radiologists who refrain from direct communication have a lower bonding to patients and are assessed to have lower competence from the patient's point of view. KEY POINTS: • Communication between radiologists and patients leads to an increased bonding affinity. • Direct communication leads to increased patient confidence in the radiology service. • Patients perceived discussion with a radiologist of high value.


Assuntos
Comunicação , Imageamento por Ressonância Magnética/psicologia , Relações Médico-Paciente , Radiologistas/psicologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ansiedade/etiologia , Atitude Frente a Saúde , Competência Clínica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Assistência ao Paciente , Encaminhamento e Consulta , Inquéritos e Questionários , Revelação da Verdade , Adulto Jovem
6.
Radiographics ; 39(7): 1965-1982, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31584860

RESUMO

Certain inflammatory pancreatic abnormalities may mimic pancreatic ductal adenocarcinoma at imaging, which precludes accurate preoperative diagnosis and may lead to unnecessary surgery. Inflammatory conditions that may appear masslike include mass-forming chronic pancreatitis, focal autoimmune pancreatitis, and paraduodenal pancreatitis or "groove pancreatitis." In addition, obstructive chronic pancreatitis can mimic an obstructing ampullary mass or main duct intraductal papillary mucinous neoplasm. Secondary imaging features such as the duct-penetrating sign, biliary or main pancreatic duct skip strictures, a capsulelike rim, the pancreatic duct-to-parenchyma ratio, displaced calcifications in patients with chronic calcific pancreatitis, the "double duct" sign, and vessel encasement or displacement can help to suggest the possibility of an inflammatory mass or a neoplastic process. An awareness of the secondary signs that favor a diagnosis of malignant or inflammatory lesions in the pancreas can help the radiologist to perform the differential diagnosis and determine the degree of suspicion for malignancy. Repeat biopsy or surgical resection may be necessary to achieve an accurate diagnosis and prevent unnecessary surgery for inflammatory conditions. Online supplemental material and DICOM image stacks are available for this article. ©RSNA, 2019.


Assuntos
Carcinoma Ductal Pancreático/diagnóstico por imagem , Neoplasias Pancreáticas/diagnóstico por imagem , Pancreatite Crônica/diagnóstico por imagem , Pancreatite Autoimune/sangue , Pancreatite Autoimune/diagnóstico por imagem , Biomarcadores Tumorais/sangue , Antígeno CA-19-9/sangue , Calcinose/diagnóstico por imagem , Carcinoma Ductal Pancreático/sangue , Diagnóstico Diferencial , Humanos , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada Multidetectores/métodos , Ductos Pancreáticos/diagnóstico por imagem , Neoplasias Pancreáticas/sangue , Pancreatite Crônica/sangue , Ultrassonografia/métodos
7.
Radiology ; 289(2): 443-454, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30015591

RESUMO

Purpose To investigate performance in detectability of small (≤1 cm) low-contrast hypoattenuating focal lesions by using filtered back projection (FBP) and iterative reconstruction (IR) algorithms from two major CT vendors across a range of 11 radiation exposures. Materials and Methods A low-contrast detectability phantom consisting of 21 low-contrast hypoattenuating focal objects (seven sizes between 2.4 and 10.0 mm, three contrast levels) embedded into a liver-equivalent background was scanned at 11 radiation exposures (volume CT dose index range, 0.5-18.0 mGy; size-specific dose estimate [SSDE] range, 0.8-30.6 mGy) with four high-end CT platforms. Data sets were reconstructed by using FBP and varied strengths of image-based, model-based, and hybrid IRs. Sixteen observers evaluated all data sets for lesion detectability by using a two-alternative-forced-choice (2AFC) paradigm. Diagnostic performances were evaluated by calculating area under the receiver operating characteristic curve (AUC) and by performing noninferiority analyses. Results At benchmark exposure, FBP yielded a mean AUC of 0.79 ± 0.09 (standard deviation) across all platforms which, on average, was approximately 2% lower than that observed with the different IR algorithms, which showed an average AUC of 0.81 ± 0.09 (P = .12). Radiation decreases of 30%, 50%, and 80% resulted in similar declines of observer detectability with FBP (mean AUC decrease, -0.02 ± 0.05, -0.03 ± 0.05, and -0.05 ± 0.05, respectively) and all IR methods investigated (mean AUC decrease, -0.00 ± 0.05, -0.04 ± 0.05, and -0.04 ± 0.05, respectively). For each radiation level and CT platform, variance in performance across observers was greater than that across reconstruction algorithms (P = .03). Conclusion Iterative reconstruction algorithms have limited radiation optimization potential in detectability of small low-contrast hypoattenuating focal lesions. This task may be further complicated by a high degree of variation in radiologists' performances, seemingly exceeding real performance differences among reconstruction algorithms. © RSNA, 2018 Online supplemental material is available for this article.


Assuntos
Fígado/diagnóstico por imagem , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Variações Dependentes do Observador , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes
8.
AJR Am J Roentgenol ; 211(6): 1306-1312, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30247978

RESUMO

OBJECTIVE: The objective of our study was to compare MRI findings in the sacroiliac joints of postpartum women (as a model of mechanical changes) and women with known axial spondyloarthritis (as an inflammatory model). SUBJECTS AND METHODS: For this prospective multicenter age-matched, case-control study, sacroiliac joint MRI examinations of 30 healthy women (mean age, 34.0 years) in the early postpartum period (mechanical group) and 30 age-matched women (mean age, 33.8 years) with known axial spondyloarthritis (retrospective inflammatory group) were compared. Blinded to clinical information, readers assessed MR images using the following scoring systems: Spondyloarthritis Research Consortium of Canada (SPARCC) MRI index, Berlin method, Assessment of Spondyloarthritis International Society (ASAS) criteria, and SPARCC MRI structural score. Descriptive statistics as percentages of the different findings (i.e., bone marrow edema [BME], erosion, fatty bone marrow replacement, backfill, ankylosis) and scores between groups and between delivery modes were compared. RESULTS: In the postpartum group, 63.3% (19/30) of women showed BME around the sacroiliac joints compared with 86.7% (26/30) of women in the spondyloarthritis group (based on ASAS criteria). Erosions were uncommon in the postpartum group (10.0% [3/30] postpartum vs 56.7% [17/30] spondyloarthritis). Fatty bone marrow replacement, backfill, and ankylosis were not seen in the postpartum group. In subjects with positive MRI findings for sacroiliitis based on ASAS criteria, the SPARCC MRI index (mean ± SD, 13.6 ± 14.5 vs 13.0 ± 10.7; p = 0.818) and Berlin method (4.5 ± 3.0 and 5.5 ± 3.5, p = 0.378) were not different between the postpartum and spondyloarthritis groups. Scores were not different between birth modalities. CONCLUSION: Pregnancy-induced BME at the sacroiliac joints, as a result of prolonged mechanical stress, was present in 63.3% of women who underwent MRI during the early postpartum period and may mimic sacroiliitis of axial spondyloarthritis.


Assuntos
Edema/diagnóstico por imagem , Imageamento por Ressonância Magnética , Transtornos Puerperais/diagnóstico por imagem , Articulação Sacroilíaca , Sacroileíte/diagnóstico por imagem , Espondilartrite/diagnóstico por imagem , Adulto , Doenças da Medula Óssea , Estudos de Casos e Controles , Diagnóstico Diferencial , Feminino , Humanos , Estudos Prospectivos , Adulto Jovem
9.
Eur Radiol ; 27(10): 4181-4187, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28374081

RESUMO

OBJECTIVES: Aim was to investigate hygienic conditions of ultrasound probes before and after hygiene training in radiology institutions in comparison to bacterial contamination in public places. METHODS: In three radiology departments, bacterial contamination was evaluated using baseline agar plates for cultures taken from 36 ultrasound probes. Afterwards teams were trained by a hygiene service centre and 36 ultrasound probes were routinely disinfected with regular disinfecting wipes and then evaluated. In comparison, bacterial contamination in public places (bus poles, n = 11; toilet seats, n = 10) were analysed. Plates were routinely incubated and the number of colony forming units (CFU) analysed. RESULTS: Cultures taken from the probes showed a median of 53 CFU before and 0 CFU after training (p < 0.001). Cultures taken from public places showed a median of 4 CFU from toilets and 28 from bus poles and had lower bacterial load in comparison to ultrasound probes before training (p = 0.055, toilets; p = 0.772, bus poles), without statistical significance. CONCLUSIONS: Bacterial contamination of ultrasound probes prior to hygiene training proved to be high and showed higher bacterial load than toilets seats or bus poles. Radiologists should be aware that the lack of hygiene in the field of ultrasound diagnostics puts patients at risk of healthcare-associated infections. KEY POINTS: • Hospital-associated infections are a problem for patient care. • Hygiene training of staff prevents bacterial contamination of ultrasound probes. • Disinfection of ultrasound probes is an easy method to protect patients.


Assuntos
Bactérias/isolamento & purificação , Desinfetantes/uso terapêutico , Desinfecção/normas , Contaminação de Equipamentos/prevenção & controle , Higiene/educação , Transdutores/microbiologia , Ultrassonografia/instrumentação , Contagem de Colônia Microbiana , Infecção Hospitalar/prevenção & controle , Humanos
10.
Eur Radiol ; 26(8): 2714-22, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26573682

RESUMO

OBJECTIVE: To investigate whether a trained group of technicians using a modified breathing command during gadoxetate-enhanced liver MRI reduces respiratory motion artefacts compared to non-trained technicians using a traditional breathing command. MATERIALS AND METHODS: The gadoxetate-enhanced liver MR images of 30 patients acquired using the traditional breathing command and the subsequent 30 patients after training the technicians to use a modified breathing command were analyzed. A subgroup of patients (n = 8) underwent scans both by trained and untrained technicians. Images obtained using the traditional and modified breathing command were compared for the presence of breathing artefacts [respiratory artefact-based image quality scores from 1 (best) to 5 (non-diagnostic)]. RESULTS: There was a highly significant improvement in the arterial phase image quality scores in patients using the modified breathing command compared to the traditional one (P < 0.001). The percentage of patients with severe and extensive breathing artefacts in the arterial phase decreased from 33.3 % to 6.7 % after introducing the modified breathing command (P = 0.021). In the subgroup that underwent MRI using both breathing commands, arterial phase image quality improved significantly (P = 0.008) using the modified breathing command. CONCLUSION: Training technicians to use a modified breathing command significantly improved arterial phase image quality of gadoxetate-enhanced liver MRI. KEY POINTS: • A modified breathing command reduced respiratory artefacts on arterial-phase gadoxetate-enhanced MRI (P < 0.001). • The modified command decreased severe and extensive arterial-phase breathing artefacts (P = 0.021). • Training technicians to use a modified breathing command improved arterial-phase images.


Assuntos
Artefatos , Gadolínio DTPA/farmacologia , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Respiração , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste/farmacologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento (Física)
11.
Radiology ; 270(2): 400-8, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24471389

RESUMO

PURPOSE: To determine whether magnetic resonance (MR) imaging heating guidewire-mediated radiofrequency (RF) hyperthermia could enhance the therapeutic effect of gemcitabine and 5-fluorouracil (5-FU) in a cholangiocarcinoma cell line and local deposit doses of chemotherapeutic drugs in swine common bile duct (CBD) walls. MATERIALS AND METHODS: The animal protocol was approved by the institutional animal care and use committee. Green fluorescent protein-labeled human cholangiocarcinoma cells and cholangiocarcinomas in 24 mice were treated with (a) combination therapy with chemotherapy (gemcitabine and 5-FU) plus RF hyperthermia, (b) chemotherapy only, (c) RF hyperthermia only, or (d) phosphate-buffered saline. Cell proliferation was quantified, and tumor changes over time were monitored with 14.0-T MR imaging and optical imaging. To enable further validation of technical feasibility, intrabiliary local delivery of gemcitabine and 5-FU was performed by using a microporous balloon with (eight pigs) or without (eight pigs) RF hyperthermia. Chemotherapy deposit doses in the bile duct walls were quantified by means of high-pressure liquid chromatography. The nonparametric Mann-Whitney U test and the paired-sample Wilcoxon signed rank test were used for data analysis. RESULTS: Combination therapy induced lower mean levels of cell proliferation than chemotherapy only and RF hyperthermia only (0.39 ± 0.13 [standard deviation] vs 0.87 ± 0.10 and 1.03 ± 0.13, P < .001). Combination therapy resulted in smaller relative tumor volume than chemotherapy only and RF hyperthermia only (0.65 ± 0.03 vs 1.30 ± 0.021 and 1.37 ± 0.05, P = .001). Only in the combination therapy group did both MR imaging and optical imaging show substantial decreases in apparent diffusion coefficients and fluorescent signals in tumor masses immediately after the treatments. Chemotherapy quantification showed a higher average drug deposit dose in swine CBD walls with intrabiliary RF hyperthermia than without it (gemcitabine: 0.32 mg/g of tissue ± 0.033 vs 0.260 mg/g ± 0.030 and 5-FU: 0.660 mg/g ± 0.060 vs 0.52 mg/g ± 0.050, P < .05). CONCLUSION: The use of intrabiliary MR imaging heating guidewire-mediated RF hyperthermia can enhance the chemotherapeutic effect on a human cholangiocarcinoma cell line and local drug deposition in swine CBD tissues.


Assuntos
Neoplasias dos Ductos Biliares/terapia , Colangiocarcinoma/terapia , Desoxicitidina/análogos & derivados , Fluoruracila/farmacologia , Hipertermia Induzida , Imageamento por Ressonância Magnética/métodos , Animais , Linhagem Celular Tumoral , Cromatografia Líquida de Alta Pressão , Terapia Combinada , Desoxicitidina/farmacologia , Humanos , Camundongos , Ondas de Rádio , Suínos , Gencitabina
12.
AJR Am J Roentgenol ; 203(1): W34-47, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24951228

RESUMO

OBJECTIVE: Hepatocellular carcinomas (HCCs) that arise in noncirrhotic livers have several histologic and biochemical features that distinguish them from HCCs occurring in the setting of cirrhosis. Because the presentation, management, and prognosis of these entities are distinct, the accurate preoperative characterization of these lesions is of great clinical significance. We review the pathogenesis, imaging appearance, and clinical implications of noncirrhotic HCCs as they pertain to the clinical radiologist. CONCLUSION: HCCs that develop in noncirrhotic patients have distinct etiologic, cytogenetic, histopathologic, and clinical features. Despite a larger tumor burden at the time of HCC diagnosis, noncirrhotic patients with HCC have better overall survival and disease-free survival than cirrhotic patients with HCC. Knowledge of the precise clinical and imaging features of this entity and of other diagnostic considerations for the noncirrhotic liver is essential for improved patient care.


Assuntos
Carcinoma Hepatocelular/patologia , Diagnóstico por Imagem , Neoplasias Hepáticas/patologia , Biomarcadores Tumorais/análise , Carcinoma Hepatocelular/etiologia , Carcinoma Hepatocelular/terapia , Meios de Contraste , Diagnóstico Diferencial , Humanos , Cirrose Hepática/patologia , Neoplasias Hepáticas/etiologia , Neoplasias Hepáticas/terapia , Prognóstico , Fatores de Risco , Análise de Sobrevida
13.
NPJ Vaccines ; 9(1): 58, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38467663

RESUMO

Vaccine priming immunogens that activate germline precursors for broadly neutralizing antibodies (bnAbs) have promise for development of precision vaccines against major human pathogens. In a clinical trial of the eOD-GT8 60mer germline-targeting immunogen, higher frequencies of vaccine-induced VRC01-class bnAb-precursor B cells were observed in the high dose compared to the low dose group. Through immunoglobulin heavy chain variable (IGHV) genotyping, statistical modeling, quantification of IGHV1-2 allele usage and B cell frequencies in the naive repertoire for each trial participant, and antibody affinity analyses, we found that the difference between dose groups in VRC01-class response frequency was best explained by IGHV1-2 genotype rather than dose and was most likely due to differences in IGHV1-2 B cell frequencies for different genotypes. The results demonstrate the need to define population-level immunoglobulin allelic variations when designing germline-targeting immunogens and evaluating them in clinical trials.

14.
J Magn Reson Imaging ; 37(6): 1476-9, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23097302

RESUMO

Ferumoxytol is an iron-containing parenteral treatment for iron deficiency anemia that was recently approved by the Food and Drug Administration. The iron is in the form of a superparamagnetic iron oxide that causes T1, T2, and T2* shortening on magnetic resonance imaging (MRI). Furthermore, the drug has a long intravascular half-life of 14-15 hours; a standard dose can affect MRI for days to months. We describe a case in which a patient underwent contrast-enhanced MRI of the liver 2 days after receiving a dose of ferumoxytol, which was unknown to the radiology team. The blood pool and soft tissues were hyperintense on T1-weighted images, concealing enhancement from the gadolinium-based contrast agent that was administered during the exam and rendering the exam nondiagnostic. Radiologists must be aware of this potential effect in screening patients for MRI and interpreting exams.


Assuntos
Artefatos , Erros de Diagnóstico/prevenção & controle , Óxido Ferroso-Férrico/uso terapêutico , Imageamento por Ressonância Magnética , Contraindicações , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
J Magn Reson Imaging ; 38(4): 987-90, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23172590

RESUMO

PURPOSE: To compare the derived T2* values and reproducibility of three methods used to assess iron-loading in heart and liver. MATERIALS AND METHODS: In 23 pediatric patients, liver and cardiac gradient-echo imaging datasets (within-exam repeated sequence pairs) were evaluated. Data analyses compared derived relaxation values (average of pairs) and coefficient of variation (reproducibility of pairs). RESULTS: T2* values showed differences across methods, with pixel-wise mean > average fit > pixel-wise median. Coefficient of variation was found to be lower (better) with pixel-wise median and average fit methods compared to the pixel-wise mean technique. Maximum coefficient of variation values were lowest for the pixel-wise median approach in both the heart and liver. CONCLUSION: Differences in derived T2* values between methods must be considered when comparing values to established magnetic resonance imaging (MRI)-biopsy formulas. The pixel-wise median and average fit methods demonstrate substantial benefits in reproducibility compared to the pixel-wise mean method. Since minimal variation in measurement is critical for patient care, median processing of relaxometry data may be preferable in both tissue types.


Assuntos
Ferro/química , Fígado/patologia , Imageamento por Ressonância Magnética , Miocárdio/patologia , Adolescente , Anemia Aplástica/patologia , Anemia de Diamond-Blackfan/patologia , Anemia Falciforme/patologia , Criança , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Talassemia/patologia , Adulto Jovem
16.
AJR Am J Roentgenol ; 200(5): 1071-6, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23617492

RESUMO

OBJECTIVE: The purpose of this study is to compare three CT image reconstruction algorithms for liver lesion detection and appearance, subjective lesion conspicuity, and measured noise. MATERIALS AND METHODS: Thirty-six patients with known liver lesions were scanned with a routine clinical three-phase CT protocol using a weight-based noise index of 30 or 36. Image data from each phase were reconstructed with filtered back projection (FBP), adaptive statistical iterative reconstruction (ASIR), and model-based iterative reconstruction (MBIR). Randomized images were presented to two independent blinded reviewers to detect and categorize the appearance of lesions and to score lesion conspicuity. Lesion size, lesion density (in Hounsfield units), adjacent liver density (in Hounsfield units), and image noise were measured. Two different unblinded truth readers established the number, appearance, and location of lesions. RESULTS: Fifty-one focal lesions were detected by truth readers. For blinded reviewers compared with truth readers, there was no difference for lesion detection among the reconstruction algorithms. Lesion appearance was statistically the same among the three reconstructions. Although one reviewer scored lesions as being more conspicuous with MBIR, the other scored them the same. There was significantly less background noise in air with MBIR (mean [± SD], 2.1 ± 1.4 HU) than with ASIR (8.9 ± 1.9 HU; p < 0.001) or FBP (10.6 ± 2.6 HU; p < 0.001). Mean lesion contrast-to-noise ratio was statistically significantly higher for MBIR (34.4 ± 29.1) than for ASIR (6.5 ± 4.9; p < 0.001) or FBP (6.3 ± 6.0; p < 0.001). CONCLUSION: In routine-dose clinical CT of the liver, MBIR resulted in comparable lesion detection, lesion characterization, and subjective lesion conspicuity, but significantly lower background noise and higher contrast-to-noise ratio compared with ASIR or FBP. This finding suggests that further investigation of the use of MBIR to enable dose reduction in liver CT is warranted.


Assuntos
Algoritmos , Artefatos , Neoplasias Hepáticas/diagnóstico por imagem , Modelos Biológicos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Interpretação Estatística de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
17.
Radiographics ; 33(4): 1125-43, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23842975

RESUMO

Cysts of the lower male genitourinary tract are uncommon and usually benign. These cysts have different anatomic origins and may be associated with a variety of genitourinary abnormalities and symptoms. Various complications may be associated with these cysts, such as urinary tract infection, pain, postvoiding incontinence, recurrent epididymitis, prostatitis, and hematospermia, and they may cause infertility. Understanding the embryologic development and normal anatomy of the lower male genitourinary tract can be helpful in evaluating these cysts and in tailoring an approach for developing a differential diagnosis. There are two main groups of cysts of the lower male genitourinary tract: intraprostatic cysts and extraprostatic cysts. Intraprostatic cysts can be further classified into median cysts (prostatic utricle cysts, müllerian duct cysts), paramedian cysts (ejaculatory duct cysts), and lateral cysts (prostatic retention cysts, cystic degeneration of benign prostatic hypertrophy, cysts associated with tumors, prostatic abscess). Extraprostatic cysts include cysts of the seminal vesicle, vas deferens, and Cowper duct. A variety of pathologic conditions can mimic these types of cysts, including ureterocele, defect resulting from transurethral resection of the prostate gland, bladder diverticulum, and hydroureter and ectopic insertion of ureter. Accurate diagnosis depends mainly on the anatomic location of the cyst. Magnetic resonance imaging and transrectal ultrasonography (US) are excellent for detecting and characterizing the nature and exact anatomic origin of these cysts. In addition, transrectal US can play an important therapeutic role in the management of cyst drainage and aspiration, as in cases of prostatic abscess.


Assuntos
Cistos/diagnóstico , Cistos/embriologia , Imageamento por Ressonância Magnética/métodos , Doenças Urogenitais Masculinas/diagnóstico , Doenças Urogenitais Masculinas/embriologia , Ultrassonografia/métodos , Humanos , Masculino
18.
Ultrasound Q ; 39(4): 188-193, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37543732

RESUMO

ABSTRACT: Nonalcoholic fatty liver disease (NAFLD) is a primary cause of parenchymal liver disease globally. There are currently several methods available to test the degree of steatosis in NAFLD patients, but all have drawbacks that limit their use.The objective of this study is to determine if a new technique, ultrasound (US) attenuation imaging (ATI), correlates with magnetic resonance proton density fat fraction imaging and hepatic echogenicity as seen on gray scale US imaging.Fifty-four patients were recruited at the University of Washington Medical Center from individuals who had already been scheduled for hepatic US or magnetic resonance imaging (MRI). All participants then underwent both hepatic MRI proton density fat fraction and US. Ultrasound images were then evaluated using ATI with 2 observers who individually determined relative grayscale echogenicity.Analysis showed positive correlation between ATI- and MRI-determined fat percentage in the case group (Spearman correlation: 0.50; P = 0.015). Furthermore, participants with NAFLD tended to have a higher ATI than controls (median: 0.70 vs 0.54 dB/cm/MHz; P < 0.001).This study demonstrates that US ATI combined with grayscale imaging is an effective way of assessing the degree of steatosis in patients with moderate to severe NAFLD.


Assuntos
Hepatopatia Gordurosa não Alcoólica , Humanos , Hepatopatia Gordurosa não Alcoólica/complicações , Hepatopatia Gordurosa não Alcoólica/diagnóstico por imagem , Hepatopatia Gordurosa não Alcoólica/patologia , Prótons , Estudos Prospectivos , Fígado/diagnóstico por imagem , Fígado/patologia , Imageamento por Ressonância Magnética/métodos , Ultrassonografia/métodos
19.
Abdom Radiol (NY) ; 48(7): 2302-2310, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37055586

RESUMO

PURPOSE: To investigate the intra-examination agreement between multi-echo gradient echo (MEGE) and confounder-corrected chemical shift-encoded (CSE) sequences for liver T2*/R2* estimations in a wide range of T2*/R2* and proton density fat fraction (PDFF) values. Exploratorily, to search for the T2*/R2* value where the agreement line breaks and examine differences between regions of low and high agreement. METHODS: Consecutive patients at risk for liver iron overload who underwent MEGE and CSE sequences within the same exam at 1.5 T were retrospectively selected. Regions of interest were drawn in the right and one in the left liver lobes on post-processed images for R2*(sec-1) and PDFF (%) estimation. Agreement between MEGE-R2* and CSE-R2* was evaluated using intra-class correlation coefficient (ICC) and Bland-Altman analysis. 95% confidence intervals (CI) were computed. Segment-and-regression analysis was performed to find the point where the agreement between sequences is interrupted. Regions of low and high agreement were examined using tree-based partitioning analyses. RESULTS: 49 patients were included. Mean MEGE-R2* was 94.2 s-1 (range: 31.0-737.1) and mean CSE-R2* 87.7 (29.7-748.1). Mean CSE-PDFF was 9.12% (0.1-43.3). Agreement was strong for R2* estimations (ICC: 0.992,95%CI 0.987,0.996), but the relation was nonlinear and possibly heteroskedastic. Lower agreement occurred when MEGE-R2* > 235 s-1, with MEGE-R2* values consistently lower than CSE-R2*. Higher agreement was observed when PDFF < 14%. CONCLUSION: MEGE-R2* and CSE-R2* strongly agree, though at higher iron content, MEGE-R2* is consistently lower than CSE-R2*. In this preliminary dataset, a breaking point for agreement was found at R2* > 235. Lower agreement was observed in patients with moderate to severe liver steatosis.


Assuntos
Ferro , Prótons , Humanos , Ferro/análise , Estudos Retrospectivos , Imageamento por Ressonância Magnética/métodos , Interpretação de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Biomarcadores
20.
Eur Radiol Exp ; 7(1): 21, 2023 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-37093398

RESUMO

BACKGROUND: We compared T1- and T2-weighted signal intensities of liver-specific (gadoxetate, gadobenate) and non-specific (gadoterate) gadolinium contrast agents (CAs) in a bile phantom. METHODS: In a phantom study, gadoxetate, gadobenate, and gadoterate were diluted in saline, blood, and bile at different concentrations (0, 0.25, 0.5. 1, 2.5, 5, 10, and 25 mM) and imaged in a 3-T magnetic resonance imaging (MRI) system using T1- and T2-weighted sequences. The maximum signal intensities of CAs were compared for each sequence separately and across all T1-weighted sequences using one-way ANOVA. RESULTS: Using T1-weighted sequences, CA concentration-dependent signal intensity increase was followed by decrease due to T2* effects. Comparing CAs for each sequence in bile yielded higher maximum signal intensities with gadobenate than gadoxetate and gadoterate using T1-weighted spin-echo (p < 0.010), multiecho gradient- and spin-echo (p < 0.001), and T1-weighted high-resolution isotropic volume excitation (eTHRIVE) sequences (p < 0.010). Comparing across all T1-weighted sequences in the bile phantom, gadobenate imaged using T1-weighted turbo field-echo (TFE) sequence showed the highest signal intensity, significantly higher than that using other CAs agents or sequences (p < 0.004) except for gadobenate and gadoxetate evaluated with three-dimensional multiecho fast field-echo (3D-mFFE) and gadoxetate with T1-weighted TFE sequence (p > 0.141). Signal reduction with CA concentration-dependent decrease was observed on T2-weighted images. CONCLUSION: In this bile phantom study of gadolinium-based CA, gadobenate and gadoxetate showed high signal intensity with T1-weighted TFE and 3D-mFFE sequences, which supports their potential utility for contrast-enhanced hepatobiliary MRI. KEY POINTS: • Contrast-enhanced magnetic resonance (MR) cholangiography depends on contrast agent type, kinetics, and concentration in bile, • We compared signal intensities of three contrast agents in a bile phantom study. • Gadobenate, gadoxetate, and gadoterate demonstrated different signal intensities at identical concentrations. • Gadoxetate and gadobenate showed high signal intensities on T1-weighted MR sequences.


Assuntos
Meios de Contraste , Gadolínio , Bile , Imageamento por Ressonância Magnética/métodos , Colangiografia , Meglumina , Espectroscopia de Ressonância Magnética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA