Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Clin Microbiol ; 58(8)2020 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-32366669

RESUMO

Nucleic acid amplification tests (NAATs) are the primary means of identifying acute infections caused by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Accurate and fast test results may permit more efficient use of protective and isolation resources and allow rapid therapeutic interventions. We evaluated the analytical and clinical performance characteristics of the Xpert Xpress SARS-CoV-2 (Xpert) test, a rapid, automated molecular test for SARS-CoV-2. Analytical sensitivity and specificity/interference were assessed with infectious SARS-CoV-2; other infectious coronavirus species, including SARS-CoV; and 85 nasopharyngeal swab specimens positive for other respiratory viruses, including endemic human coronaviruses (hCoVs). Clinical performance was assessed using 483 remnant upper- and lower-respiratory-tract specimens previously analyzed by standard-of-care (SOC) NAATs. The limit of detection of the Xpert test was 0.01 PFU/ml. Other hCoVs, including Middle East respiratory syndrome coronavirus, were not detected by the Xpert test. SARS-CoV, a closely related species in the subgenus Sarbecovirus, was detected by a broad-range target (E) but was distinguished from SARS-CoV-2 (SARS-CoV-2-specific N2 target). Compared to SOC NAATs, the positive agreement of the Xpert test was 219/220 (99.5%), and the negative agreement was 250/261 (95.8%). A third tie-breaker NAAT resolved all but three of the discordant results in favor the Xpert test. The Xpert test provided sensitive and accurate detection of SARS-CoV-2 in a variety of upper- and lower-respiratory-tract specimens. The high sensitivity and short time to results of approximately 45 min may impact patient management.


Assuntos
Betacoronavirus/isolamento & purificação , Técnicas de Laboratório Clínico/métodos , Infecções por Coronavirus/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Pneumonia Viral/diagnóstico , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Automação Laboratorial/métodos , Betacoronavirus/genética , COVID-19 , Teste para COVID-19 , Criança , Pré-Escolar , Infecções por Coronavirus/virologia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Nasofaringe/virologia , Pandemias , Pneumonia Viral/virologia , SARS-CoV-2 , Sensibilidade e Especificidade , Adulto Jovem
2.
J Clin Microbiol ; 51(11): 3780-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24006011

RESUMO

Detecting colonization of patients with carbapenemase-producing bacteria can be difficult. This study compared the sensitivity and specificity of a PCR-based method (Xpert MDRO) for detecting blaKPC, blaNDM, and blaVIM carbapenem resistance genes using GeneXpert cartridges to the results of culture with and without a broth enrichment step on 328 rectal, perirectal, and stool samples. The culture method included direct inoculation of a MacConkey agar plate on which a 10-µg meropenem disk was placed and plating on MacConkey agar after overnight enrichment of the sample in MacConkey broth containing 1 µg/ml of meropenem. Forty-three (13.1%) samples were positive by PCR for blaKPC and 11 (3.4%) were positive for blaVIM; none were positive for blaNDM. The sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of the PCR assay for blaKPC were 100%, 99.0%, 93.0%, and 100%, respectively, compared to broth enrichment culture and sequencing of target genes. The sensitivity, specificity, PPV, and NPV of the assay for blaVIM were 100%, 99.4%, 81.8%, and 100%, respectively. Since none of the clinical samples contained organisms with blaNDM, 66 contrived stool samples were prepared at various dilutions using three Klebsiella pneumoniae isolates containing blaNDM. The PCR assay showed 100% positivity at dilutions from 300 to 1,800 CFU/ml and 93.3% at 150 CFU/ml. The Xpert MDRO PCR assay required 2 min of hands-on time and 47 min to complete. Rapid identification of patients colonized with carbapenemase-producing organisms using multiplex PCR may help hospitals to improve infection control activities.


Assuntos
Proteínas de Bactérias/genética , Portador Sadio/diagnóstico , Bactérias Gram-Negativas/enzimologia , Bactérias Gram-Negativas/isolamento & purificação , Infecções por Bactérias Gram-Negativas/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Reação em Cadeia da Polimerase/métodos , beta-Lactamases/genética , Proteínas de Bactérias/metabolismo , Técnicas Bacteriológicas/métodos , Portador Sadio/microbiologia , Fezes/microbiologia , Bactérias Gram-Negativas/genética , Infecções por Bactérias Gram-Negativas/microbiologia , Humanos , Períneo/microbiologia , Reto/microbiologia , Sensibilidade e Especificidade , beta-Lactamases/metabolismo
3.
J Clin Microbiol ; 48(7): 2495-501, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20504986

RESUMO

We performed the first studies of analytic sensitivity, analytic specificity, and dynamic range for the new Xpert MTB/RIF assay, a nucleic acid amplification-based diagnostic system that detects Mycobacterium tuberculosis and rifampin (RIF) resistance in under 2 h. The sensitivity of the assay was tested with 79 phylogenetically and geographically diverse M. tuberculosis isolates, including 42 drug-susceptible isolates and 37 RIF-resistant isolates containing 13 different rpoB mutations or mutation combinations. The specificity of the assay was tested with 89 nontuberculosis bacteria, fungi, and viruses. The Xpert MTB/RIF assay correctly identified all 79 M. tuberculosis isolates and correctly excluded all 89 nontuberculosis isolates. RIF resistance was correctly identified in all 37 resistant isolates and in none of the 42 susceptible isolates. Dynamic range was assessed by adding 10(2) to 10(7) CFU of M. tuberculosis into M. tuberculosis-negative sputum samples. The assay showed a log-linear relationship between cycle threshold and input CFU over the entire concentration range. Resistance detection in the presence of different mixtures of RIF-resistant and RIF-susceptible DNA was assessed. Resistance detection was dependent on the particular mutation and required between 65% and 100% mutant DNA to be present in the sample for 95% certainty of resistance detection. Finally, we studied whether assay specificity could be affected by cross-contaminating amplicons generated by the GenoType MTBDRplus assay. M. tuberculosis was not detected until at least 10(8) copies of an MTBDRplus amplicon were spiked into 1 ml of sputum, suggesting that false-positive results would be unlikely to occur.


Assuntos
Antibióticos Antituberculose/farmacologia , Testes de Sensibilidade Microbiana/métodos , Técnicas de Diagnóstico Molecular/métodos , Mycobacterium tuberculosis , Técnicas de Amplificação de Ácido Nucleico/métodos , Rifampina/farmacologia , Proteínas de Bactérias/genética , DNA Bacteriano/análise , RNA Polimerases Dirigidas por DNA , Modelos Lineares , Mycobacterium tuberculosis/efeitos dos fármacos , Mycobacterium tuberculosis/genética , Mycobacterium tuberculosis/isolamento & purificação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Escarro/microbiologia
4.
J Clin Microbiol ; 48(1): 229-37, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19864480

RESUMO

Current nucleic acid amplification methods to detect Mycobacterium tuberculosis are complex, labor-intensive, and technically challenging. We developed and performed the first analysis of the Cepheid Gene Xpert System's MTB/RIF assay, an integrated hands-free sputum-processing and real-time PCR system with rapid on-demand, near-patient technology, to simultaneously detect M. tuberculosis and rifampin resistance. Analytic tests of M. tuberculosis DNA demonstrated a limit of detection (LOD) of 4.5 genomes per reaction. Studies using sputum spiked with known numbers of M. tuberculosis CFU predicted a clinical LOD of 131 CFU/ml. Killing studies showed that the assay's buffer decreased M. tuberculosis viability by at least 8 logs, substantially reducing biohazards. Tests of 23 different commonly occurring rifampin resistance mutations demonstrated that all 23 (100%) would be identified as rifampin resistant. An analysis of 20 nontuberculosis mycobacteria species confirmed high assay specificity. A small clinical validation study of 107 clinical sputum samples from suspected tuberculosis cases in Vietnam detected 29/29 (100%) smear-positive culture-positive cases and 33/39 (84.6%) or 38/53 (71.7%) smear-negative culture-positive cases, as determined by growth on solid medium or on both solid and liquid media, respectively. M. tuberculosis was not detected in 25/25 (100%) of the culture-negative samples. A study of 64 smear-positive culture-positive sputa from retreatment tuberculosis cases in Uganda detected 63/64 (98.4%) culture-positive cases and 9/9 (100%) cases of rifampin resistance. Rifampin resistance was excluded in 54/55 (98.2%) susceptible cases. Specificity rose to 100% after correcting for a conventional susceptibility test error. In conclusion, this highly sensitive and simple-to-use system can detect M. tuberculosis directly from sputum in less than 2 h.


Assuntos
Antituberculosos/farmacologia , Técnicas Bacteriológicas/métodos , Farmacorresistência Bacteriana , Mycobacterium tuberculosis/efeitos dos fármacos , Sistemas Automatizados de Assistência Junto ao Leito , Rifampina/farmacologia , Tuberculose/diagnóstico , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/isolamento & purificação , Reação em Cadeia da Polimerase/métodos , Sensibilidade e Especificidade , Escarro/microbiologia , Tuberculose/microbiologia , Uganda , Vietnã , Adulto Jovem
5.
J Clin Microbiol ; 43(2): 813-7, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15695685

RESUMO

The ViroSeq human immunodeficiency virus type 1 (HIV-1) genotyping system is an integrated system for identification of drug resistance mutations in HIV-1 protease and reverse transcriptase (RT). Reagents are included for sample preparation, reverse transcription, PCR amplification, and sequencing. Software is provided to assemble and edit sequence data and to generate a drug resistance report. We determined the sensitivity and specificity of the ViroSeq system for mutation detection using an ABI PRISM 3100 genetic analyzer with a set of clinical samples and recombinant viruses. Twenty clinical plasma samples (viral loads, 1,800 to 10,500 copies/ml) were characterized by cloning and sequencing individual viral variants. Twelve recombinant-virus samples (viral loads, approximately 2,000 to 5,000 copies/ml) were also prepared. Eleven recombinant-virus samples contained drug resistance mutations as 40% mixtures. One recombinant-virus sample contained an insertion at codon 69 in RT (100% mutant). Plasma and recombinant-virus samples were analyzed using the ViroSeq system. Each sample was analyzed on three consecutive days at each of three testing laboratories. The sensitivity of mutation detection was 99.65% for the clinical plasma samples and 99.7% for the recombinant-virus preparations. The specificity of mutation detection was 99.95% for the clinical samples and 100% for the recombinant-virus mixtures. The base calling accuracy of the 3100 instrument was 99.91%. Mutations in clinical plasma samples and recombinant-virus samples were detected with high sensitivity and specificity, including mutations present as mixtures. This report supports the use of the ViroSeq system for identification of drug resistance mutations in HIV-1 protease and RT genes.


Assuntos
Farmacorresistência Viral/genética , Protease de HIV/genética , Transcriptase Reversa do HIV/genética , HIV-1/efeitos dos fármacos , Mutação , Kit de Reagentes para Diagnóstico , Fármacos Anti-HIV/farmacologia , Genótipo , HIV-1/enzimologia , HIV-1/genética , Humanos , Testes de Sensibilidade Microbiana/métodos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA