Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
AJNR Am J Neuroradiol ; 44(11): 1291-1295, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37827722

RESUMO

BACKGROUND AND PURPOSE: Time-resolved 3D rotational angiography (4D-DSA) has been used to demonstrate details of the angioarchitecture of AVM, whereas it has rarely been used to describe features of dural AVF. In this exploratory study, we analyzed dural AVFs with a novel 4D software prototype, developed and provided by Siemens, to determine whether identification of the location of the fistulous point, grading, and treatment planning were feasible. MATERIALS AND METHODS: 4D-DSA volumes were calculated from existing 3D rotational angiography data sets of patients with dural AVFs. The 4D-DSA volumes were displayed in a virtual DSA mode and MPR or MIP in 3 orthogonal planes and compared with 2D-DSA by 2 experienced neuroradiologists. Fusions with unenhanced CT or MR images were used to improve visualization of adjacent anatomic structures. RESULTS: Comparison with 2D-DSA showed that evaluation of the fistulous point and grading according to the classification of Borden, Cognard, or Barrow was feasible in 26 of 27 cases. In 8 of 27 cases, 4D-DSA was considered advantageous for determining the fistulous point and the course of the draining vein in the dural AVF with cortical venous drainage, especially in the frontoethmoidal and frontoparietal regions. In 6 cases, the display of angioarchitecture was considered inferior to that of 2D-DSA due to motion artifacts, suboptimal selection of the injected vessel, and lack of temporal resolution. CONCLUSIONS: Detailed analysis of dural AVFs according to the standardized display of 4D-DSA volumes was feasible and helpful in understanding the angioarchitecture in selected cases. Further improvement and validation of the 4D software should solidify the complementary role of 4D-DSA to conventional 2D-DSA series.


Assuntos
Imageamento Tridimensional , Crânio , Humanos , Imageamento Tridimensional/métodos , Angiografia Digital/métodos , Software , Artefatos
2.
AJNR Am J Neuroradiol ; 43(1): 102-109, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-35027345

RESUMO

BACKGROUND AND PURPOSE: Time-resolved 3DRA (4D-DSA) and flat panel conebeam CTA are new methods for visualizing the microangioarchitecture of cerebral AVMs. We applied a 4D software prototype to a series of cases of AVMs to assess the utility of this method in relation to treatment planning. MATERIALS AND METHODS: In 33 patients with AVMs, 4D volumes and flat panel conebeam CTA images were recalculated from existing 3D rotational angiography data. The multiplanar reconstructions were used to determine intranidal arteriovenous branching patterns, categorize them according to common classifications of AVM angioarchitecture, and compare the results with those from 2D-DSA. RESULTS: 4D flat panel conebeam CTA showed angioarchitectural features equal to or better than those of 2D-DSA in 30 of 33 cases. In particular, the reconstructions helped in understanding the intranidal microvasculature. Fistulous direct arteriovenous connections with a low degree of arterial branching (n = 22) could be distinguished from plexiform arterial networks before the transition to draining veins (n = 11). We identified AVMs with a single draining vein (n = 20) or multiple draining veins (n = 10). Arteriovenous shunts in the lateral wall of the draining veins (n = 22) could be distinguished from cases with increased venous branching and shunts between corresponding intranidal arteries and veins (n = 11). Limitations were the time-consuming postprocessing and the difficulties in correctly tracing intranidal vessels in larger and complex AVMs. CONCLUSIONS: 4D flat panel conebeam CTA reconstructions allow detailed analysis of the nidal angioarchitecture of AVMs. However, further improvements in temporal resolution and automated reconstruction techniques are needed to use the method generally in clinical practice.


Assuntos
Malformações Arteriovenosas Intracranianas , Angiografia Digital/métodos , Humanos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/cirurgia , Microvasos , Software
3.
AJNR Am J Neuroradiol ; 42(10): 1762-1768, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34503946

RESUMO

BACKGROUND AND PURPOSE: By means of artificial intelligence, 3D angiography is a novel postprocessing method for 3D imaging of cerebral vessels. Because 3D angiography does not require a mask run like the current standard 3D-DSA, it potentially offers a considerable reduction of the patient radiation dose. Our aim was an assessment of the diagnostic value of 3D angiography for visualization of cerebrovascular pathologies. MATERIALS AND METHODS: 3D-DSA data sets of cerebral aneurysms (n CA = 10), AVMs (n AVM = 10), and dural arteriovenous fistulas (dAVFs) (n dAVF = 10) were reconstructed using both conventional and prototype software. Corresponding reconstructions have been analyzed by 2 neuroradiologists in a consensus reading in terms of image quality, injection vessel diameters (vessel diameter [VD] 1/2), vessel geometry index (VGI = VD1/VD2), and specific qualitative/quantitative parameters of AVMs (eg, location, nidus size, feeder, associated aneurysms, drainage, Spetzler-Martin score), dAVFs (eg, fistulous point, main feeder, diameter of the main feeder, drainage), and cerebral aneurysms (location, neck, size). RESULTS: In total, 60 volumes have been successfully reconstructed with equivalent image quality. The specific qualitative/quantitative assessment of 3D angiography revealed nearly complete accordance with 3D-DSA in AVMs (eg, mean nidus size3D angiography/3D-DSA= 19.9 [SD, 10.9]/20.2 [SD, 11.2] mm; r = 0.9, P = .001), dAVFs (eg, mean diameter of the main feeder3D angiography/3D-DSA= 2.04 [SD, 0.65]/2.05 [SD, 0.63] mm; r = 0.9, P = .001), and cerebral aneurysms (eg, mean size3D angiography/3D-DSA= 5.17 [SD, 3.4]/5.12 [SD, 3.3] mm; r = 0.9, P = .001). Assessment of the geometry of the injection vessel in 3D angiography data sets did not differ significantly from that of 3D-DSA (vessel geometry indexAVM: r = 0.84, P = .003; vessel geometry indexdAVF: r = 0.82, P = .003; vessel geometry indexCA: r = 0.84, P <.001). CONCLUSIONS: In this study, the artificial intelligence-based 3D angiography was a reliable method for visualization of complex cerebrovascular pathologies and showed results comparable with those of 3D-DSA. Thus, 3D angiography is a promising postprocessing method that provides a significant reduction of the patient radiation dose.


Assuntos
Malformações Vasculares do Sistema Nervoso Central , Aneurisma Intracraniano , Malformações Arteriovenosas Intracranianas , Angiografia Digital , Inteligência Artificial , Angiografia Cerebral , Humanos , Imageamento Tridimensional , Aneurisma Intracraniano/diagnóstico por imagem , Angiografia por Ressonância Magnética
4.
AJNR Am J Neuroradiol ; 41(6): 976-979, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32439643

RESUMO

It was the aim of our pilot study to investigate whether time-resolved flat panel conebeam CTA is able to demonstrate small cortical vessels in vivo. In 8 patients with small AVMs, time-resolved coronal MPRs of the vasculature of the frontal cortex were recalculated from 3D rotational angiography datasets with the use of a novel software prototype. 4D flat panel conebeam CTA demonstrated the course of the cortical arteries with small perpendicular side branches to the underlying cortex. Pial arterial and venous networks could also be identified, corresponding to findings in injection specimens. Reasonable image quality was achieved in 6 of 8 cases. In this small study, in vivo display of the cortical microvasculature with 4D flat panel conebeam CTA was feasible and superior to other angiographic imaging modalities.


Assuntos
Córtex Cerebral/irrigação sanguínea , Angiografia por Tomografia Computadorizada/métodos , Tomografia Computadorizada Quadridimensional/métodos , Neuroimagem/métodos , Software , Angiografia Digital/métodos , Feminino , Humanos , Masculino , Microvasos/anatomia & histologia , Pessoa de Meia-Idade , Projetos Piloto
5.
AJNR Am J Neuroradiol ; 38(6): 1169-1176, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28408632

RESUMO

BACKGROUND AND PURPOSE: 4D DSA allows acquisition of time-resolved 3D reconstructions of cerebral vessels by using C-arm conebeam CT systems. The aim of our study was to evaluate this new method by qualitative and quantitative means. MATERIALS AND METHODS: 2D and 4D DSA datasets were acquired in patients presenting with AVMs, dural arteriovenous fistulas, and cerebral aneurysms. 4D DSA was compared with 2D DSA in a consensus reading of qualitative and quantitative parameters of AVMs (eg, location, feeder, associated aneurysms, nidus size, drainage, Martin-Spetzler Score), dural arteriovenous fistulas (eg, fistulous point, main feeder, diameter of the main feeder, drainage), and cerebral aneurysms (location, neck configuration, aneurysmal size). Identifiability of perforators and diameters of the injection vessel (ICA, vertebral artery) were analyzed in 2D and 4D DSA. Correlation coefficients and a paired t test were calculated for quantitative parameters. The effective patient dose of the 4D DSA protocol was evaluated with an anthropomorphic phantom. RESULTS: In 26 patients, datasets were acquired successfully (AVM = 10, cerebral aneurysm = 10, dural arteriovenous fistula = 6). Qualitative and quantitative evaluations of 4D DSA in AVMs (nidus size: r = 0.99, P = .001), dural arteriovenous fistulas (diameter of the main feeder: r = 0.954, P = .03), and cerebral aneurysms (aneurysmal size: r = 1, P = .001) revealed nearly complete accordance with 2D DSA. Perforators were comparably visualized with 4D DSA. Measurement of the diameter of the injection vessel in 4D DSA was equivalent to that in 2D DSA (P = .039). The effective patient dose of 4D DSA was 1.2 mSv. CONCLUSIONS: 4D DSA is feasible for imaging of AVMs, dural arteriovenous fistulas, and cerebral aneurysms. 4D DSA offers reliable visualization of the cerebral vasculature and may improve the understanding and treatment of AVMs and dural arteriovenous fistulas. The number of 2D DSA acquisitions required for an examination may be reduced through 4D DSA.


Assuntos
Angiografia Digital/métodos , Encéfalo/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Aneurisma Intracraniano/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Neuroimagem/métodos , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
AJNR Am J Neuroradiol ; 38(4): 740-746, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28126751

RESUMO

BACKGROUND AND PURPOSE: Time-resolved 3D-DSA (4D-DSA) enables viewing vasculature from any desired angle and time frame. We investigated whether these advantages may facilitate treatment planning and the feasibility of using 4D-DSA as a single imaging technique in AVM/dural arteriovenous fistula radiosurgery. MATERIALS AND METHODS: Twenty consecutive patients (8 dural arteriovenous fistulas and 12 AVMs; 13 men and 7 women; mean age, 45 years; range, 18-64 years) who were scheduled for gamma knife radiosurgery were recruited (November 2014 to October 2015). An optimal volume of reconstructed time-resolved 3D volumes that defines the AVM nidus/dural arteriovenous fistula was sliced into 2D-CT-like images. The original radiosurgery treatment plan was overlaid retrospectively. The registration errors of stereotactic 4D-DSA were compared with those of integrated stereotactic imaging. AVM/dural arteriovenous fistula volumes were contoured, and disjoint and conjoint components were identified. The Wilcoxon signed rank test and the Wilcoxon rank sum test were adopted to evaluate registration errors and contoured volumes of stereotactic 4D-DSA and integration of stereotactic MR imaging and stereotactic 2D-DSA. RESULTS: Sixteen of 20 patients were successfully registered in Advanced Leksell GammaPlan Program. The registration error of stereotactic 4D-DSA was smaller than that of integrated stereotactic imaging (P = .0009). The contoured AVM volume of 4D-DSA was smaller than that contoured on the integration of MR imaging and 2D-DSA, while major inconsistencies existed in cases of dural arteriovenous fistula (P = .042 and 0.039, respectively, for measurements conducted by 2 authors). CONCLUSIONS: Implementation of stereotactic 4D-DSA data for gamma knife radiosurgery for brain AVM/dural arteriovenous fistula is feasible. The ability of 4D-DSA to demonstrate vascular morphology and hemodynamics in 4 dimensions potentially reduces the target volumes of irradiation in vascular radiosurgery.


Assuntos
Angiografia Digital/métodos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Malformações Arteriovenosas Intracranianas/cirurgia , Radiocirurgia/métodos , Adolescente , Adulto , Idoso , Malformações Vasculares do Sistema Nervoso Central/diagnóstico por imagem , Malformações Vasculares do Sistema Nervoso Central/cirurgia , Circulação Cerebrovascular , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
7.
AJNR Am J Neuroradiol ; 36(5): 960-6, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25678483

RESUMO

BACKGROUND AND PURPOSE: Cerebral blood volume, acquired with flat panel detector CT by injecting contrast medium into the ascending aorta, enabled real-time acquisition of brain functional information with remarkable reduction of contrast medium usage comparing to an intravenous injection approach. However, individual vasculature and flow variations cause inhomogeneous contrast medium distribution and unexpected asymmetric perfusion for certain patients even without cerebral circulatory disorders. This work aimed at testing the feasibility of using color-coded quantitative DSA to predict the reliability of flat panel detector CT-based CBV maps by injecting contrast medium into the ascending aorta by exploring the correlation between measurements of color-coded quantitative DSA and the symmetry of CBV maps. MATERIALS AND METHODS: For 12 patients without perfusion-related cerebral abnormities, color-coded quantitative DSA at the aortic arch and flat panel detector CT-based CBV maps by injecting contrast medium into the ascending aorta were acquired. In color-coded quantitative DSA, ROIs were defined on the bilateral common carotid arteries. Time-density curves were extracted, and area under the curve values were calculated. To evaluate brain perfusion symmetry, we defined ROIs on the anterior and middle cerebral artery territories in CBV maps, and quantitative CBV values were extracted. RESULTS: Eight patients demonstrated good perfusion symmetry with relative CBV of 0.96 ± 0.06, and their relative area under the curve was found to be 0.99 ± 0.02. For the other 4 patients, CBV from the left hemisphere was significantly lower than that from the right with relative CBV of 0.81 ± 0.09. This asymmetric perfusion was confirmed by the color-coded quantitative DSA with relative area under the curve values of 0.79 ± 0.03. CONCLUSIONS: This preliminary study showed good correlation between relative area under the curve from color-coded quantitative DSA and relative CBV from CBV maps. Color-coded quantitative DSA potentially helped sort out patients whose vascular anatomy could support reliable CBV acquisitions of flat detector CT by injecting contrast medium into the ascending aorta.


Assuntos
Mapeamento Encefálico/métodos , Artéria Carótida Primitiva/fisiologia , Angiografia Cerebral/métodos , Circulação Cerebrovascular/fisiologia , Meios de Contraste/administração & dosagem , Idoso , Aorta/anatomia & histologia , Área Sob a Curva , Artéria Carótida Primitiva/anatomia & histologia , Meios de Contraste/farmacocinética , Feminino , Humanos , Injeções Intra-Arteriais , Masculino , Pessoa de Meia-Idade , Perfusão , Curva ROC , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
8.
AJNR Am J Neuroradiol ; 36(6): 1176-81, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25721077

RESUMO

BACKGROUND AND PURPOSE: From the time-attenuation curves of DSA flow parameters, maximal intensity, maximal slope, and full width at half maximum of selected vascular points are defined. The study explores the reliability of defining the flow parameters by the time-attenuation curves of DSA. MATERIALS AND METHODS: Seventy patients with unilateral carotid artery stenosis (group A) and 56 healthy controls (group B) were retrospectively enrolled. Fixed contrast injection protocols and DSA acquisition parameters were used with all patients. The M1, sigmoid sinus, and internal jugular vein on anteroposterior view DSA and the M2, parietal vein, and superior sagittal sinus on lateral view DSA were chosen as ROI targets for measuring flow parameters. The difference of time of maximal intensity between 2 target points was defined as the circulation time between the target points. RESULTS: The maximal intensity difference of 2 selected points from the ICA to the M1, sigmoid sinus, internal jugular vein, M2, parietal vein, and superior sagittal sinus was significantly longer in group A than in group B. The maximum slope of M1, M2, and the superior sagittal sinus was significantly lower in group A than in group B. The full width at half maximum of M1 and M2 was significantly larger in group A than in group B. The maximal slope of M1 demonstrated the best diagnostic performance. CONCLUSIONS: The maximal intensity difference of 2 selected points derived from DSA can be used as a definitive alternative flow parameter for intracranial circulation time measurement. Maximal slope and full width at half maximum complement the maximal intensity difference of 2 selected points in defining flow characteristics of healthy subjects and patients with carotid stenosis.


Assuntos
Angiografia Digital/métodos , Velocidade do Fluxo Sanguíneo/fisiologia , Estenose das Carótidas/diagnóstico , Estenose das Carótidas/fisiopatologia , Interpretação de Imagem Assistida por Computador/métodos , Adulto , Idoso , Estenose das Carótidas/diagnóstico por imagem , Estudos de Casos e Controles , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Fatores de Tempo
9.
Phys Med Biol ; 60(14): 5571-99, 2015 Jul 21.
Artigo em Inglês | MEDLINE | ID: mdl-26134417

RESUMO

The Challenge on Liver Ultrasound Tracking (CLUST) was held in conjunction with the MICCAI 2014 conference to enable direct comparison of tracking methods for this application. This paper reports the outcome of this challenge, including setup, methods, results and experiences. The database included 54 2D and 3D sequences of the liver of healthy volunteers and tumor patients under free breathing. Participants had to provide the tracking results of 90% of the data (test set) for pre-defined point-landmarks (healthy volunteers) or for tumor segmentations (patient data). In this paper we compare the best six methods which participated in the challenge. Quantitative evaluation was performed by the organizers with respect to manual annotations. Results of all methods showed a mean tracking error ranging between 1.4 mm and 2.1 mm for 2D points, and between 2.6 mm and 4.6 mm for 3D points. Fusing all automatic results by considering the median tracking results, improved the mean error to 1.2 mm (2D) and 2.5 mm (3D). For all methods, the performance is still not comparable to human inter-rater variability, with a mean tracking error of 0.5-0.6 mm (2D) and 1.2-1.8 mm (3D). The segmentation task was fulfilled only by one participant, resulting in a Dice coefficient ranging from 76.7% to 92.3%. The CLUST database continues to be available and the online leader-board will be updated as an ongoing challenge.


Assuntos
Benchmarking , Bases de Dados Factuais/normas , Imageamento Tridimensional/normas , Neoplasias Hepáticas/diagnóstico por imagem , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/normas , Ultrassonografia/normas , Algoritmos , Estudos de Casos e Controles , Congressos como Assunto , Humanos , Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas/patologia , Respiração
10.
AJNR Am J Neuroradiol ; 34(10): 1914-21, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23620072

RESUMO

BACKGROUND AND PURPOSE: Conventional 3D-DSA volumes are reconstructed from a series of projections containing temporal information. It was our purpose to develop a technique which would generate fully time-resolved 3D-DSA vascular volumes having better spatial and temporal resolution than that which is available with CT or MR angiography. MATERIALS AND METHODS: After a single contrast injection, projections from the mask and fill rotation are subtracted to create a series of vascular projections. With the use of these projections, a conventional conebeam CT reconstruction is generated (conventional 3D-DSA). This is used to constrain the reconstruction of individual 3D temporal volumes, which incorporate temporal information from the acquired projections (4D-DSA). RESULTS: Typically, 30 temporal volumes per second are generated with the use of currently available flat detector systems, a factor of ∼200 increase over that achievable with the use of multiple gantry rotations. Dynamic displays of the reconstructed volumes are viewable from any angle. Good results have been obtained by using both intra-arterial and intravenous injections. CONCLUSIONS: It is feasible to generate time-resolved 3D-DSA vascular volumes with the use of commercially available flat detector angiographic systems and clinically practical injection protocols. The spatial resolution and signal-to-noise ratio of the time frames are largely determined by that of the conventional 3D-DSA constraining image and not by that of the projections used to generate the 3D reconstruction. The spatial resolution and temporal resolution exceed that of CTA and MRA, and the small vessel contrast is increased relative to that of conventional 2D-DSA due to the use of maximum intensity projections.


Assuntos
Angiografia Digital/métodos , Tomografia Computadorizada Quadridimensional/métodos , Imageamento Tridimensional/métodos , Malformações Arteriovenosas Intracranianas/diagnóstico por imagem , Angiografia por Ressonância Magnética/métodos , Angiografia Digital/instrumentação , Animais , Bases de Dados Factuais , Estudos de Viabilidade , Tomografia Computadorizada Quadridimensional/instrumentação , Humanos , Imageamento Tridimensional/instrumentação , Angiografia por Ressonância Magnética/instrumentação , Imagens de Fantasmas , Razão Sinal-Ruído
11.
AJNR Am J Neuroradiol ; 33(9): 1685-90, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22499839

RESUMO

BACKGROUND AND PURPOSE: Intracranial hemodynamics are important for management of SOAD. This study aimed to monitor peri-stent placement intracranial CirT of patients with SOAD. MATERIALS AND METHODS: Twenty-five patients received stent placement for extracranial ICA stenosis, and 34 patients with normal CirT were recruited as controls. Their color-coded DSAs were used to define the Tmax of selected intravascular ROI. A total of 20 ROIs of the ICA, OphA, ACA, MCA, FV, PV, OV, SSS, SS, IJV, and MCV were selected. rTmax was defined as the Tmax at the selected region of interest minus Tmax at the cervical segment of the ICA (I1 on AP view and IA on lateral view). rTmax of the PV was defined as intracranial CirT. Intergroup and intragroup longitudinal comparisons of rTmax were performed. RESULTS: rTmax values of the normal cohorts were as follows: ICA-AP, 0.12; ICA-LAT, 0.10; A1, 0.28; A2, 0.53; A3, 0.81; M1, 0.40; M2, 0.80; M3, 0.95; OphA, 0.35; FV, 4.83; PV, 5.11; OV, 5.17; SSS, 6.16; SS, 6.51; IJV, 6.81; and MCV, 3.86 seconds. Before stent placement, the rTmax values of arterial ROIs, except A3 and M3, were prolonged compared with values from control subjects (P < .05). None of the rTmax of any venous ROIs in the stenotic group was prolonged with significance. After stent placement, the rTmax of all arterial ROIs shortened significantly, except A1and M3. Poststenting rTmax was not different from the control group. CONCLUSIONS: Without extra contrast medium and radiation dosages, color-coded quantitative DSA enables real-time monitoring of peri-therapeutic intracranial CirT in patients with SOAD .


Assuntos
Angiografia Digital/métodos , Angiografia Cerebral/métodos , Circulação Cerebrovascular , Transtornos Cerebrovasculares/diagnóstico , Transtornos Cerebrovasculares/fisiopatologia , Colorimetria/métodos , Idoso , Velocidade do Fluxo Sanguíneo , Transtornos Cerebrovasculares/cirurgia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Assistência Perioperatória/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA