Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 139
Filtrar
1.
Catheter Cardiovasc Interv ; 97(1): 20-21, 2021 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33460271

RESUMO

Coronary atherectomy has been around for many years, and the body of evidence for its use in complex calcified lesions has grown. Calcific coronary disease presents a particularly challenging clinical scenario in PCI, having poorer outcomes than noncalcified lesions. This study is the first to identify calcified nodules as an independent predictor of worse outcomes after atherectomy and PCI. Continued study of lesion characteristics will improve our understanding of PCI outcomes and help manage patients in the long-term after PCI and stenting.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Calcificação Vascular , Aterectomia Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/terapia
2.
Catheter Cardiovasc Interv ; 98(3): 586-587, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34498392

RESUMO

The MANTA is a new, easy-to-use, collagen plug-based vascular closure device specifically designed for large-bore arteriotomy closure. The authors report on their experience comparing the MANTA device with the Perclose ProGlide technique in patients undergoing transcatheter aortic valve replacement. They found similar rates of success and vascular complications with both devices, suggesting that MANTA is a suitable option for these patients. It remains to be determined whether one device will emerge as the ideal choice for most patients. Device cost is a significant barrier to widespread adoption, but price has decreased recently.


Assuntos
Cateterismo Periférico , Dispositivos de Oclusão Vascular , Cateterismo Periférico/efeitos adversos , Artéria Femoral , Técnicas Hemostáticas/efeitos adversos , Humanos , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 96(1): 98-99, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32652845

RESUMO

Atherothrombotic burden (ATB) correlates with myocardial blush grade (MBG), a known predictor of mortality and outcome after ST-elevation myocardial infarction. Quantitative or semiquantitative analysis of ATB with optical coherence tomography may assist interventional cardiologists in post-PCI prognostication and, perhaps, in rendering more aggressive antiplatelet therapy. Future studies comparing treatment strategies for post-PCI patients with elevated ATB or depressed MBG may identify best practices after acute coronary syndromes.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Angiografia Coronária , Humanos , Reperfusão Miocárdica , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Tomografia de Coerência Óptica , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 96(7): 1498-1499, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33306885

RESUMO

Identification of hypoattenuated leaflet thickening (HALT) and subacute leaflet thrombosis has become widely recognized. Patients with anatomical changes associated with moderate or greater aortic regurgitation (larger sinus of Valsalva and eccentric left ventricular remodeling) appear to have less HALT early postprocedure compared with those without. Further research on the risk factors including anatomical and hemodynamic variables should further our knowledge of these entities so we can better manage patient both pre and post TAVR.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 96(6): 1294-1295, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-33217181

RESUMO

The transcatheter pulmonary valve replacement technique has evolved over the past decade. There is risk of injuring the tricuspid valve if the transcatheter device is advanced uncovered across the right heart. Advancing a long sheath past the landing zone and uncovering the device can help mitigate this risk, at the expense of requiring larger-caliber sheaths. Additional refinements of the technique such as the one reported here, along with improvements in device design, are likely to further reduce complications.


Assuntos
Implante de Prótese de Valva Cardíaca , Valva Pulmonar , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/cirurgia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
6.
Catheter Cardiovasc Interv ; 95(6): 1169-1170, 2020 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-32421238

RESUMO

Thoracic aortic disease has usually been treated with surgery. Thoracic endovascular aortic repair is challenging if supra-aortic vessels are involved. In situ fenestration of the main graft from a retrograde approach while using bare-metal stents as bridge stents appears to be a safe and practical technique.


Assuntos
Aneurisma da Aorta Torácica , Doenças da Aorta , Implante de Prótese Vascular , Procedimentos Endovasculares , Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Prótese Vascular , Humanos , Metais , Stents , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 95(7): 1336-1337, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32537862

RESUMO

Patients with PAD have worse outcomes after TAVR. The extent and distribution of PAD are important considerations in determining TAVR feasibility and choosing an access site. Further research is needed to establish the best approaches to treating patients with aortic and iliofemoral disease severe enough to limit device delivery.


Assuntos
Pneumopatias , Doença Arterial Periférica , Substituição da Valva Aórtica Transcateter , Aorta , Humanos , Resultado do Tratamento
8.
Catheter Cardiovasc Interv ; 95(4): 765-766, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32159288

RESUMO

Multimodality interventions, including both percutaneous and surgical approaches, are paramount in maintaining vascular fistula and graft patency in hemodialysis patients. Mechanical thrombectomy with Angiojet AVX or Solent Proxi of AVFs and AVGs achieved acceptable technical and clinical success rates (>90%) in combination with adjuvant percutaneous transluminal angioplasty and stenting. Future prospective studies using intravascular imaging before therapy may be useful when deciding which treatment modalities to use for AVFs and AVGs.


Assuntos
Derivação Arteriovenosa Cirúrgica , Diálise Renal , Oclusão de Enxerto Vascular , Humanos , Estudos Prospectivos , Trombectomia , Resultado do Tratamento , Grau de Desobstrução Vascular
9.
J Endovasc Ther ; 27(3): 414-420, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32193971

RESUMO

Purpose: To evaluate the safety and effectiveness of the MANTA percutaneous vascular closure device in patients undergoing percutaneous endovascular aneurysm repair (PEVAR) or thoracic endovascular aortic repair (TEVAR). Materials and Methods: The SAFE MANTA Study (ClinicalTrials.gov identifier NCT02908880) was a prospective, single-arm, multicenter trial in patients undergoing endovascular interventions using large-bore sheaths (transcatheter aortic valve replacement, PEVAR, or TEVAR) at 20 sites in North America. Patient selection intended to test the MANTA device in populations without morbid obesity, severe calcification, or a severely scarred femoral access area. Of the 263 patients enrolled in the primary analysis cohort, 53 (20.2%) patients (mean age 74.9±8.9 years; 41 men) underwent PEVAR (n=51) or TEVAR (n=2) procedures and form the cohort for this subgroup analysis. Per protocol a single MANTA device was deployed in all PEVAR/TEVAR cases. Results: The mean time to hemostasis in the PEVAR/TEVAR cohort was 35±91 seconds, with a median time of 19 seconds vs 24 seconds in the overall SAFE MANTA population. The MANTA device met the definition for technical success in 52 (98%) of 53 PEVAR/TEVAR cases compared with 97.7% in the overall SAFE MANTA population. One (1.9%) major complication (access-site stenosis) occurred in this subgroup compared to 14 (5.3%) events in the SAFE population. In the PEVAR/TEVAR group, 1 pseudoaneurysm was noted prior to discharge, another at 30-day follow-up, and one at 60 days. One (1.9%) of the 3 minor pseudoaneurysms was treated with ultrasound-guided compression and the other 2 required no treatment. Conclusion: The MANTA device demonstrated a short time to hemostasis and low complication rates compared with published literature results of other percutaneous closure devices. Time to hemostasis and complication rates were comparable between the PEVAR/TEVAR patients and the full SAFE MANTA study cohort. The MANTA device provides reliable closure with a single percutaneous device for PEVAR/TEVAR procedures.


Assuntos
Aorta Torácica/cirurgia , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular , Cateterismo Periférico , Procedimentos Endovasculares , Hemorragia/prevenção & controle , Hemostasia , Técnicas Hemostáticas/instrumentação , Dispositivos de Oclusão Vascular , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Cateterismo Periférico/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Feminino , Hemorragia/sangue , Hemorragia/etiologia , Técnicas Hemostáticas/efeitos adversos , Humanos , Masculino , América do Norte , Estudos Prospectivos , Punções , Fatores de Tempo , Resultado do Tratamento
10.
Catheter Cardiovasc Interv ; 94(3): 414-415, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-31670878

RESUMO

Transcatheter pulmonary valve replacement (TPVR) is a safe and feasible procedure for treating pulmonary stenosis, failed right ventricular conduits, or failed bioprosthetic valves. The medtronic melody valve and the Edwards Sapien XT and S3 valves have been the main prosthetic valves used in TPVR. Using the GORE DrySeal sheath helps valve delivery and facilitates TPVR.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Cateterismo Cardíaco , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 93(6): 1150-1151, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-31025522

RESUMO

Preprocedural myocardial fibrosis as identified by magnetic resonance imaging correlates with worse outcomes after MitraClip placement. Post-MitraClip mitral regurgitation gradient >2 or ischemic cardiomyopathy also correlates with worse outcomes. In the literature, other variables are mentioned (e.g., severe tricuspid regurgitation, atrial fibrillation, postoperative mitral valve area and/or gradient) that correlate with worse post-MitraClip outcomes.


Assuntos
Cardiomiopatias , Insuficiência da Valva Mitral , Fibrose , Humanos , Valva Mitral , Estudos Retrospectivos , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 93(2): 322-323, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30719861

RESUMO

In a randomized, controlled trial, the Occlutech Figulla Flex II occluder was shown to be noninferior to the Amplatzer Septal Occluder. Both devices provided greater than 90% efficacy, with limited residual shunting and major complications. Although the risk of overall device erosions was low, larger and longer-term studies are needed to distinguish the differences between devices.


Assuntos
Forame Oval Patente , Comunicação Interatrial , Dispositivo para Oclusão Septal , Cateterismo Cardíaco , Humanos , Desenho de Prótese , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 93(3): E198-E199, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30770662

RESUMO

Children with branch pulmonary artery stenosis represent a challenging cohort for stenting Premounted stent implantation provides immediate obstruction relief and hemodynamic improvement in infants Planned stent intervention is required to account for somatic growth and next stage palliation in children Continued slenderization of adult coronary and peripheral interventions, stent technology, and delivery systems may allow for more durable solutions in light of patient size.


Assuntos
Estenose de Artéria Pulmonar , Adulto , Criança , Hemodinâmica , Humanos , Lactente , Artéria Pulmonar , Soluções , Stents
14.
Catheter Cardiovasc Interv ; 93(3): 464-465, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-30770667

RESUMO

The Edwards Sapien S3 demonstrated clinical and technical feasibility in this cohort undergoing percutaneous pulmonary valve implantation. Traversing the tricuspid apparatus with an unsheathed delivery system continues to pose a risk for tricuspid valve injury. Future design innovations need to accommodate for large outflow tracts without adjacent aortic or coronary compression and allow for safe device delivery with minimal trauma to the tricuspid apparatus.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Valva Pulmonar/cirurgia , Valva Aórtica/cirurgia , Uso Off-Label , Desenho de Prótese , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 93(4): 590-591, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30859730

RESUMO

Isolated valve surgery is associated with a small incidence of postoperative PCI. PCI after single-valve surgery is associated with elevated mortality and morbidity risk. Possible mechanisms for cardiac ischemia include iatrogenic causes (such as suture-related or air embolism), intimal hyperplasia, and immunologic reaction to the valve prosthesis.


Assuntos
Doença da Artéria Coronariana , Implante de Prótese de Valva Cardíaca , Intervenção Coronária Percutânea , Humanos , Incidência , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 93(4): E261, 2019 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-30859733

RESUMO

Baseline risk scores for TAVI patients, including STS and EuroSCORE, might not predict long-term outcomes. Including postprocedural data might improve risk stratification. The ACEF-7 risk score includes the lowest creatinine clearance in the first 7 postprocedural days and appears to be a good predictor of worse long-term outcomes.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Creatinina , Humanos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Volume Sistólico
20.
Catheter Cardiovasc Interv ; 92(4): 741-742, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30341822

RESUMO

Aortic dissection is associated with a high mortality rate and has been increasingly treated with endovascular therapy. False lumen (FL) patency has been shown to be associated with worse outcomes. FL interventions that incorporate the FLIRT (FL intervention to promote remodeling and thrombosis) concept have been associated with improved aortic remodeling that may confer favorable long-term outcomes.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Trombose/cirurgia , Aortografia , Humanos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA