Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Infect Control Hosp Epidemiol ; 43(11): 1705-1707, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-34250879

RESUMO

We describe the follow-up investigation of an outbreak of endophthalmitis due to Burkholderia contaminans following cataract surgery in a single clinic. Whole-genome sequence analysis of bacteria recovered from affected patients and the clinic identified the clinic's ventilation system as the source of infection.


Assuntos
Infecções por Burkholderia , Complexo Burkholderia cepacia , Endoftalmite , Humanos , Infecções por Burkholderia/epidemiologia , Endoftalmite/epidemiologia , Surtos de Doenças
2.
J Cataract Refract Surg ; 47(10): 1327-1332, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34156771

RESUMO

PURPOSE: To investigate the effectiveness of a mobile laminar airflow (LAF) device designed to reduce both airborne particles and lint fibers within the sterile field during cataract surgery. SETTING: Cincinnati Eye Institute, Cincinnati, Ohio. DESIGN: Prospective case series. METHODS: The number of airborne particles sized 0.5 µm, 1.0 µm, and 1.5 µm were measured at different locations and times during 116 routine phacoemulsification procedures with and without the use of a mobile LAF device. In a companion study, the presence of lint fibers in 99 eyes undergoing cataract surgery with a mobile LAF device was compared with 50 eyes in the control group. Lint fibers were differentiated as either falling onto the ocular surface or being carried into the sterile field by an instrument. RESULTS: A statistically significant reduction (P < .0005) occurred in all 3 particle sizes measurements when the LAF device was used: 79.0% (93.6 ± 16.1 vs 445.3 ± 30.9), 81.7% (11.30 ± 1.98 vs 61.85 ± 5.34), and 90.8% (0.241 ± 0.056 vs 2.624 ± 0.362) in the 0.5 µm, 1.0 µm and 5.0 µm particles, respectively. Lint fibers were identified in 18% (9/50) of eyes in the control group and 16.16% (16/99) of eyes in the LAF group. Although the number of lint fibers carried into the sterile field was similar in each group, the incidence of lint fibers falling onto the sterile field was reduced from 6% (3/50) to 0% (0/99) when the LAF was used (P = .014). CONCLUSIONS: The mobile LAF device was highly effective in reducing the number of particulate matter and lint fibers within the sterile surgical field when used during cataract surgery.


Assuntos
Cristalino , Oftalmologia , Facoemulsificação , Humanos , Salas Cirúrgicas , Infecção da Ferida Cirúrgica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA