Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Appl Opt ; 62(36): 9568-9576, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38108782

RESUMO

X-ray reflectance and film stress were measured for 12 bilayer and trilayer reflective interference coatings and compared with a single-layer Ir coating. The interference coatings comprise a base layer of W, Pt, or Ir, top layers of either C or B 4 C, and, in the case of the trilayer coatings, middle layers of either Co or Ni. The coatings were deposited by magnetron sputtering. Film stress was measured using the wafer curvature technique, while X-ray reflectance was measured at grazing incidence over the ∼0.1-10k e V energy band using synchrotron radiation. Re-measurements over a period of more than two years of both stress and X-ray reflectance were used to assess temporal stability. The X-ray reflectance of all 12 bilayer and trilayer coatings was found to be both stable over time and substantially higher than single-layer Ir over much of the energy range investigated, particularly below ∼4k e V, except near the B and C K-edges, and the Co and Ni L-edges, where we observe sharp, narrow drops in reflectance due to photo-absorption in layers containing these materials. Film stress was found to be substantially smaller than single-layer Ir in all cases as well; however, film stress was also found to change over time for all coatings (including the single-layer Ir coating). The effective area of future X-ray telescopes will be substantially higher if these high reflectance bilayer and/or trilayer coatings are used in place of single-layer coatings. Additionally, the smaller film stresses found in the bilayer and trilayer coatings relative to single-layer Ir will reduce coating-stress-driven mirror deformations. Nevertheless, as all the interference films studied here have stresses that are far from zero (albeit smaller than that of single-layer Ir), methods to mitigate such deformations must be developed in order to construct high-angular-resolution telescopes using thin mirror segments. Furthermore, unless film stress can be sufficiently stabilized over time, perhaps through thermal annealing, any such mitigation methods must also account for the temporal instability of film stress that was found in all coatings investigated here.

2.
J Synchrotron Radiat ; 25(Pt 2): 407-412, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-29488919

RESUMO

Precise monitoring of the incoming photon flux is crucial for many experiments using synchrotron radiation. For photon energies above a few keV, thin semiconductor photodiodes can be operated in transmission for this purpose. Diamond is a particularly attractive material as a result of its low absorption. The responsivity of a state-of-the art diamond quadrant transmission detector has been determined, with relative uncertainties below 1% by direct calibration against an electrical substitution radiometer. From these data and the measured transmittance, the thickness of the involved layers as well as the mean electron-hole pair creation energy were determined, the latter with an unprecedented relative uncertainty of 1%. The linearity and X-ray scattering properties of the device are also described.

3.
J Pept Sci ; 23(7-8): 539-548, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28429417

RESUMO

The chemical synthesis of proteins typically involves the solid-phase peptide synthesis of unprotected peptide fragments that are stitched together in solution by native chemical ligation (NCL). The process is slow, and throughput is limited because of the need for repeated high performance liquid chromatography purification steps after both solid-phase peptide synthesis and NCL. With an aim to provide faster access to functional proteins and to accelerate the functional analysis of synthetic proteins by parallelization, we developed a method for the high performance liquid chromatography-free synthesis of proteins on the surface of microtiter plates. The method relies on solid-phase synthesis of unprotected peptide fragments, immobilization of the C-terminal fragment and on-surface NCL with an unprotected peptide thioester in crude form. Herein, we describe the development of a suitable immobilization chemistry. We compared (i) formation of nickel(II)-oligohistidine complexes, (ii) Cu-based [2 + 3] alkine-azide cycloaddition and (iii) hydrazone ligation. The comparative study identified the hydrazone ligation as most suitable. The sequence of immobilization via hydrazone ligation, on-surface NCL and radical desulfurization furnished the targeted SH3 domains in near quantitative yield. The synthetic proteins were functional as demonstrated by an on-surface fluorescence-based saturation binding analysis. Copyright © 2017 European Peptide Society and John Wiley & Sons, Ltd.


Assuntos
Proteínas/síntese química , Técnicas de Síntese em Fase Sólida/métodos , Técnicas de Química Sintética , Cromatografia Líquida , Peptídeos/síntese química , Peptídeos/química , Proteínas/química
4.
Langmuir ; 32(3): 772-8, 2016 Jan 26.
Artigo em Inglês | MEDLINE | ID: mdl-26673729

RESUMO

The continuously growing complexity of nanodrugs urges for complementary characterization techniques which can elude the current limitations. In this paper, the applicability of continuous contrast variation in small-angle X-ray scattering (SAXS) for the accurate size determination of a complex nanocarrier is demonstrated on the example of PEGylated liposomal doxorubicin (Caelyx). The mean size and average electron density of Caelyx was determined by SAXS using a gradient of aqueous iodixanol (Optiprep), an iso-osmolar suspending medium. The study is focused on the isoscattering point position and the analysis of the Guinier region of the scattering curves recorded at different solvent densities. An average diameter of (69 ± 5) nm and electron density of (346.2 ± 1.2) nm(-3) were determined for the liposomal formulation of doxorubicin. The response of the liposomal nanocarrier to increasing solvent osmolality and the structure of the liposome-encapsulated doxorubicin after the osmotic shrinkage of the liposome are evaluated with sucrose contrast variation in SAXS and wide-angle X-ray scattering (WAXS). In the case of using sucrose as contrast agent, a clear osmolality threshold at 670 mOsm kg(-1) was observed, above which the liposomal drug carriers start to shrink, though preserving the intraliposomal doxorubicin structure. The average size obtained by this technique is smaller than the value measured by dynamic light scattering (DLS), though this difference is expected due to the hydrodynamic size of the PEG moieties attached to the liposomal surface, which are not probed with solvent contrast variation in SAXS. The advantages and drawbacks of the proposed technique are discussed in comparison to DLS, the most frequently used sizing method in nanomedicine.


Assuntos
Doxorrubicina/análogos & derivados , Portadores de Fármacos/química , Lipossomos/química , Nanomedicina/métodos , Doxorrubicina/química , Concentração Osmolar , Tamanho da Partícula , Polietilenoglicóis/química , Espalhamento a Baixo Ângulo , Ácidos Tri-Iodobenzoicos/química , Água/química , Difração de Raios X
5.
J Synchrotron Radiat ; 22(2): 225-38, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25723924

RESUMO

Proteins that contain metal cofactors are expected to be highly radiation sensitive since the degree of X-ray absorption correlates with the presence of high-atomic-number elements and X-ray energy. To explore the effects of local damage in serial femtosecond crystallography (SFX), Clostridium ferredoxin was used as a model system. The protein contains two [4Fe-4S] clusters that serve as sensitive probes for radiation-induced electronic and structural changes. High-dose room-temperature SFX datasets were collected at the Linac Coherent Light Source of ferredoxin microcrystals. Difference electron density maps calculated from high-dose SFX and synchrotron data show peaks at the iron positions of the clusters, indicative of decrease of atomic scattering factors due to ionization. The electron density of the two [4Fe-4S] clusters differs in the FEL data, but not in the synchrotron data. Since the clusters differ in their detailed architecture, this observation is suggestive of an influence of the molecular bonding and geometry on the atomic displacement dynamics following initial photoionization. The experiments are complemented by plasma code calculations.


Assuntos
Ferredoxinas/efeitos da radiação , Metaloproteínas/efeitos da radiação , Síncrotrons , Clostridium/efeitos da radiação , Cristalografia por Raios X/métodos , Relação Dose-Resposta à Radiação , Humanos , Modelos Moleculares , Lesões por Radiação , Sensibilidade e Especificidade
6.
Anal Bioanal Chem ; 407(11): 3045-53, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25326887

RESUMO

Checking the performance of energy dispersive X-ray spectrometers as well as validation of the results obtained with energy dispersive X-ray spectrometry (EDX) at a scanning electron microscope (SEM) involve the use of (certified) reference and dedicated test materials. This paper gives an overview on the test materials mostly employed by SEM/EDX users and accredited laboratories as well as on those recommended in international standards. The new BAM reference material EDS-CRM, which is currently in the process of certification, is specifically designed for the characterization of EDS systems at a SEM through calibration of the spectrometer efficiency in analytical laboratories in a simple manner. The certification of the spectra by means of a reference EDS is described. The focus is on the traceability of EDS efficiency which is ensured by measurements of the absolute detection efficiency of silicon drift detectors (SDD) and Si(Li) detectors at the laboratory of the PTB using the electron storage ring BESSY II as a primary X-ray source standard. A new test material in development at BAM for testing the performance of an EDS in the energy range below 1 keV is also briefly presented.

7.
J Biol Chem ; 288(10): 6946-56, 2013 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-23293023

RESUMO

Neutrophil extracellular traps are networks of DNA and associated proteins produced by nucleosome release from activated neutrophils in response to infection stimuli and have recently been identified as key mediators between innate immunity, inflammation, and hemostasis. The interaction of DNA and histones with a number of hemostatic factors has been shown to promote clotting and is associated with increased thrombosis, but little is known about the effects of DNA and histones on the regulation of fibrin stability and fibrinolysis. Here we demonstrate that the addition of histone-DNA complexes to fibrin results in thicker fibers (increase in median diameter from 84 to 123 nm according to scanning electron microscopy data) accompanied by improved stability and rigidity (the critical shear stress causing loss of fibrin viscosity increases from 150 to 376 Pa whereas the storage modulus of the gel increases from 62 to 82 pascals according to oscillation rheometric data). The effects of DNA and histones alone are subtle and suggest that histones affect clot structure whereas DNA changes the way clots are lysed. The combination of histones + DNA significantly prolongs clot lysis. Isothermal titration and confocal microscopy studies suggest that histones and DNA bind large fibrin degradation products with 191 and 136 nM dissociation constants, respectively, interactions that inhibit clot lysis. Heparin, which is known to interfere with the formation of neutrophil extracellular traps, appears to prolong lysis time at a concentration favoring ternary histone-DNA-heparin complex formation, and DNase effectively promotes clot lysis in combination with tissue plasminogen activator.


Assuntos
Coagulação Sanguínea , DNA/química , Fibrina/química , Histonas/química , Anticoagulantes/química , Anticoagulantes/metabolismo , Anticoagulantes/farmacologia , DNA/metabolismo , Desoxirribonucleases/metabolismo , Fibrina/metabolismo , Fibrina/ultraestrutura , Fibrinólise/efeitos dos fármacos , Proteínas de Fluorescência Verde/genética , Proteínas de Fluorescência Verde/metabolismo , Heparina/química , Heparina/metabolismo , Heparina/farmacologia , Histonas/metabolismo , Substâncias Macromoleculares/química , Substâncias Macromoleculares/metabolismo , Microscopia Confocal , Microscopia Eletrônica de Varredura , Neutrófilos/metabolismo , Estabilidade Proteica/efeitos dos fármacos , Espalhamento a Baixo Ângulo , Estresse Mecânico , Trombose/sangue , Trombose/metabolismo , Fatores de Tempo , Ativador de Plasminogênio Tecidual/química , Ativador de Plasminogênio Tecidual/genética , Ativador de Plasminogênio Tecidual/metabolismo , Difração de Raios X
8.
J Synchrotron Radiat ; 21(Pt 3): 529-36, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24763642

RESUMO

A dedicated in-vacuum X-ray detector based on the hybrid pixel PILATUS 1M detector has been installed at the four-crystal monochromator beamline of the PTB at the electron storage ring BESSY II in Berlin, Germany. Owing to its windowless operation, the detector can be used in the entire photon energy range of the beamline from 10 keV down to 1.75 keV for small-angle X-ray scattering (SAXS) experiments and anomalous SAXS at absorption edges of light elements. The radiometric and geometric properties of the detector such as quantum efficiency, pixel pitch and module alignment have been determined with low uncertainties. The first grazing-incidence SAXS results demonstrate the superior resolution in momentum transfer achievable at low photon energies.

9.
Opt Lett ; 39(7): 2141-4, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24686695

RESUMO

An alternate multilayer (AML) grating has been prepared by coating an ion etched lamellar grating with a B4C/Mo2C multilayer (ML) having a layer thickness close to the groove depth. Such a structure behaves as a 2D synthetic crystal and can reach very high efficiencies when the Bragg condition is satisfied. This AML coated grating has been characterized at the SOLEIL Metrology and Tests Beamline between 0.7 and 1.7 keV and at the four-crystal monochromator beamline of Physikalisch-Technische Bundesanstalt (PTB) at BESSY II between 1.75 and 3.4 keV. A peak diffraction efficiency of nearly 27% was measured at 2.2 keV. The measured efficiencies are well reproduced by numerical simulations made with the electromagnetic propagation code CARPEM. Such AML gratings, paired with a matched ML mirror, constitute efficient monochromators for intermediate energy photons. They will extend the accessible energy for many applications as x-ray absorption spectroscopy or x-ray magnetic circular dichroism experiments.

10.
J Appl Crystallogr ; 55(Pt 4): 993-1001, 2022 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-35974742

RESUMO

A versatile software package in the form of a Python extension, named CDEF (computing Debye's scattering formula for extraordinary form factors), is proposed to calculate approximate scattering profiles of arbitrarily shaped nanoparticles for small-angle X-ray scattering (SAXS). CDEF generates a quasi-randomly distributed point cloud in the desired particle shape and then applies the open-source software DEBYER for efficient evaluation of Debye's scattering formula to calculate the SAXS pattern (https://github.com/j-from-b/CDEF). If self-correlation of the scattering signal is not omitted, the quasi-random distribution provides faster convergence compared with a true-random distribution of the scatterers, especially at higher momentum transfer. The usage of the software is demonstrated for the evaluation of scattering data of Au nanocubes with rounded edges, which were measured at the four-crystal monochromator beamline of PTB at the synchrotron radiation facility BESSY II in Berlin. The implementation is fast enough to run on a single desktop computer and perform model fits within minutes. The accuracy of the method was analyzed by comparison with analytically known form factors and verified with another implementation, the SPONGE, based on a similar principle with fewer approximations. Additionally, the SPONGE coupled to McSAS3 allows one to retrieve information on the uncertainty of the size distribution using a Monte Carlo uncertainty estimation algorithm.

11.
Nanoscale ; 14(41): 15475-15483, 2022 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-36226758

RESUMO

The grazing emission X-ray fluorescence (GEXRF) technique offers a promising approach to determining the spatial distribution of various chemical elements in nanostructures. In this paper, we present a comparison with grazing incidence small-angle X-ray scattering (GISAXS), an established method for dimensional nanometrology, on periodic TiO2 nanostructures fabricated by a self-aligned double patterning (SADP) process. We further test the potential of GEXRF for process control in the presence of residual chromium on the structures. The angle-resolved fluorescence emission as well as the scattered radiation from the surface are collected with photon-counting hybrid pixel area detectors using scanning-free detection schemes. By modelling the X-ray standing wave (XSW) field in the vicinity of and inside the nanostructure, it is possible to obtain both the angle-resolved fluorescence intensities and the far-field scattering intensities from the same model. The comparison also illustrates that for ensemble photon-based measurement methods, accounting for roughness effects and imperfections can be essential when modelling advanced nanostructured surfaces.

12.
Nanoscale ; 14(12): 4690-4704, 2022 Mar 24.
Artigo em Inglês | MEDLINE | ID: mdl-35262538

RESUMO

We describe the outcome of a large international interlaboratory study of the measurement of particle number concentration of colloidal nanoparticles, project 10 of the technical working area 34, "Nanoparticle Populations" of the Versailles Project on Advanced Materials and Standards (VAMAS). A total of 50 laboratories delivered results for the number concentration of 30 nm gold colloidal nanoparticles measured using particle tracking analysis (PTA), single particle inductively coupled plasma mass spectrometry (spICP-MS), ultraviolet-visible (UV-Vis) light spectroscopy, centrifugal liquid sedimentation (CLS) and small angle X-ray scattering (SAXS). The study provides quantitative data to evaluate the repeatability of these methods and their reproducibility in the measurement of number concentration of model nanoparticle systems following a common measurement protocol. We find that the population-averaging methods of SAXS, CLS and UV-Vis have high measurement repeatability and reproducibility, with between-labs variability of 2.6%, 11% and 1.4% respectively. However, results may be significantly biased for reasons including inaccurate material properties whose values are used to compute the number concentration. Particle-counting method results are less reproducibile than population-averaging methods, with measured between-labs variability of 68% and 46% for PTA and spICP-MS respectively. This study provides the stakeholder community with important comparative data to underpin measurement reproducibility and method validation for number concentration of nanoparticles.

13.
J Phys Chem Lett ; 12(16): 4018-4023, 2021 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-33878272

RESUMO

The morphology and structural changes of confined matter are still far from being understood. This report deals with the development of a novel in situ method based on the combination of anomalous small-angle X-ray scattering (ASAXS) and X-ray absorption near edge structure (XANES) spectroscopy to directly probe the evolution of the xenon adsorbate phase in mesoporous silicon during gas adsorption at 165 K. The interface area and size evolution of the confined xenon phase were determined via ASAXS demonstrating that filling and emptying the pores follow two distinct mechanisms. The mass density of the confined xenon was found to decrease prior to pore emptying. XANES analyses showed that Xe exists in two different states when confined in mesopores. This combination of methods provides a smart new tool for the study of nanoconfined matter for catalysis, gas, and energy storage applications.

14.
Sci Rep ; 10(1): 20712, 2020 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-33244030

RESUMO

Controlling thickness and tightness of surface passivation shells is crucial for many applications of core-shell nanoparticles (NP). Usually, to determine shell thickness, core and core/shell particle are measured individually requiring the availability of both nanoobjects. This is often not fulfilled for functional nanomaterials such as many photoluminescent semiconductor quantum dots (QD) used for bioimaging, solid state lighting, and display technologies as the core does not show the application-relevant functionality like a high photoluminescence (PL) quantum yield, calling for a whole nanoobject approach. By combining high-resolution transmission electron microscopy (HR-TEM) and X-ray photoelectron spectroscopy (XPS), a novel whole nanoobject approach is developed representatively for an ultrabright oleic acid-stabilized, thick shell CdSe/CdS QD with a PL quantum yield close to unity. The size of this spectroscopically assessed QD, is in the range of the information depth of usual laboratory XPS. Information on particle size and monodispersity were validated with dynamic light scattering (DLS) and small angle X-ray scattering (SAXS) and compared to data derived from optical measurements. In addition to demonstrating the potential of this novel whole nanoobject approach for determining architectures of small nanoparticles, the presented results also highlight challenges faced by different sizing and structural analysis methods and method-inherent uncertainties.

15.
Med Phys ; 36(6): 2107-17, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-19610300

RESUMO

Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasimonochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten Kalpha emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement factor increases from 2.2 to 2.4 by using quasi-monochromatic instead of polychromatic radiation. An additional increase in the radiation dose by a factor of 1.4 due to the focusing characteristic of the x-ray optical module was calculated. Photoelectric-enhanced radiation therapy based on a clinical CT unit combined with an x-ray optical module is a novel therapy option in radiation oncology. The optimized quasi-monochromatic radiation is strongly focused and ensures high photoelectric dose enhancement for iodine.


Assuntos
Radioterapia Conformacional/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
17.
Nanomaterials (Basel) ; 9(4)2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30939772

RESUMO

The industrial exploitation of high value nanoparticles is in need of robust measurement methods to increase the control over product manufacturing and to implement quality assurance. InNanoPart, a European metrology project responded to these needs by developing methods for the measurement of particle size, concentration, agglomeration, surface chemistry and shell thickness. This paper illustrates the advancements this project produced for the traceable measurement of nanoparticle number concentration in liquids through small angle X-ray scattering (SAXS) and single particle inductively coupled plasma mass spectrometry (spICPMS). It also details the validation of a range of laboratory methods, including particle tracking analysis (PTA), dynamic light scattering (DLS), differential centrifugal sedimentation (DCS), ultraviolet visible spectroscopy (UV-vis) and electrospray-differential mobility analysis with a condensation particle counter (ES-DMA-CPC). We used a set of spherical gold nanoparticles with nominal diameters between 10 nm and 100 nm and discuss the results from the various techniques along with the associated uncertainty budgets.

18.
Anal Chem ; 80(22): 8398-405, 2008 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-18855420

RESUMO

As part of a comprehensive study of X-ray emission from planetary surfaces and in particular the planet Mercury, we have measured fluorescent radiation from a number of planetary analog rock samples using monochromatized synchrotron radiation provided by the BESSY II electron storage ring. The experiments were carried out using a purpose built X-ray fluorescence (XRF) spectrometer chamber developed by the Physikalisch-Technische Bundesanstalt, Germany's national metrology institute. The XRF instrumentation is absolutely calibrated and allows for reference-free quantitation of rock sample composition, taking into account secondary photon- and electron-induced enhancement effects. The fluorescence data, in turn, have been used to validate a planetary fluorescence simulation tool based on the GEANT4 transport code. This simulation can be used as a mission analysis tool to predict the time-dependent orbital XRF spectral distributions from planetary surfaces throughout the mapping phase.

19.
IUCrJ ; 5(Pt 4): 521, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30002853

RESUMO

[This corrects the article DOI: 10.1107/S2052252517006297.].

20.
Toxicol Res (Camb) ; 7(2): 172-181, 2018 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30090572

RESUMO

Monitoring the physicochemical characteristics of nanoparticles following internalisation by cells is a vital step in understanding their biological impact and toxicity. Here, the feasibility of a methodology utilising gentle enzymatic lysis of cells containing internalised particles and direct analysis of the lysates for the particle size, agglomeration state and concentration, is investigated. It is demonstrated that following internalisation, all types of studied silica particles partially agglomerate/aggregate, with the degree and rate of the observed transformation closely correlated with the initial particle surface chemistry. Several different particle populations are noted and characterised in terms of their size and concentration. Good agreement between different complementary techniques is reached in terms of the average particle diameter. Particle concentration is determined here with techniques capable of mass and number-based measurements, with limitations of approaches utilising signal conversion to equivalent particle numbers identified and discussed.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA