Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Mol Cell ; 49(4): 583-90, 2013 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-23438854

RESUMO

High-resolution mass spectrometry (MS)-based proteomics has progressed tremendously over the years. For model organisms like yeast, we can now quantify complete proteomes in just a few hours. Developments discussed in this Perspective will soon enable complete proteome analysis of mammalian cells, as well, with profound impact on biology and biomedicine.


Assuntos
Proteínas Fúngicas/análise , Proteoma/análise , Leveduras/química , Animais , Células Cultivadas , Biologia Computacional , Proteínas Fúngicas/química , Proteínas Fúngicas/isolamento & purificação , Humanos , Espectrometria de Massas , Proteoma/química , Proteoma/isolamento & purificação , Proteômica
2.
Mol Cell Proteomics ; 16(4): 694-705, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28126900

RESUMO

Recent advances in mass spectrometry (MS)-based proteomics now allow very deep coverage of cellular proteomes. To achieve near-comprehensive identification and quantification, the combination of a first HPLC-based peptide fractionation orthogonal to the on-line LC-MS/MS step has proven to be particularly powerful. This first dimension is typically performed with milliliter/min flow and relatively large column inner diameters, which allow efficient pre-fractionation but typically require peptide amounts in the milligram range. Here, we describe a novel approach termed "spider fractionator" in which the post-column flow of a nanobore chromatography system enters an eight-port flow-selector rotor valve. The valve switches the flow into different flow channels at constant time intervals, such as every 90 s. Each flow channel collects the fractions into autosampler vials of the LC-MS/MS system. Employing a freely configurable collection mechanism, samples are concatenated in a loss-less manner into 2-96 fractions, with efficient peak separation. The combination of eight fractions with 100 min gradients yields very deep coverage at reasonable measurement time, and other parameters can be chosen for even more rapid or for extremely deep measurements. We demonstrate excellent sensitivity by decreasing sample amounts from 100 µg into the sub-microgram range, without losses attributable to the spider fractionator and while quantifying close to 10,000 proteins. Finally, we apply the system to the rapid automated and in-depth characterization of 12 different human cell lines to a median depth of 11,472 different proteins, which revealed differences recapitulating their developmental origin and differentiation status. The fractionation technology described here is flexible, easy to use, and facilitates comprehensive proteome characterization with minimal sample requirements.


Assuntos
Fracionamento Químico/instrumentação , Peptídeos/química , Proteômica/métodos , Fracionamento Químico/métodos , Cromatografia Líquida de Alta Pressão , Células HeLa , Humanos , Proteômica/instrumentação , Espectrometria de Massas em Tandem
3.
Nat Methods ; 11(3): 319-24, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24487582

RESUMO

Mass spectrometry (MS)-based proteomics typically employs multistep sample-preparation workflows that are subject to sample contamination and loss. We report an in-StageTip method for performing sample processing, from cell lysis through elution of purified peptides, in a single, enclosed volume. This robust and scalable method largely eliminates contamination or loss. Peptides can be eluted in several fractions or in one step for single-run proteome analysis. In one day, we obtained the largest proteome coverage to date for budding and fission yeast, and found that protein copy numbers in these cells were highly correlated (R(2) = 0.78). Applying the in-StageTip method to quadruplicate measurements of a human cell line, we obtained copy-number estimates for 9,667 human proteins and observed excellent quantitative reproducibility between replicates (R(2) = 0.97). The in-StageTip method is straightforward and generally applicable in biological or clinical applications.


Assuntos
Células Eucarióticas/metabolismo , Dosagem de Genes/genética , Proteômica/métodos , Contaminação por DNA , Células HeLa , Humanos , Reprodutibilidade dos Testes , Proteínas de Saccharomyces cerevisiae/genética
4.
Mol Cell Proteomics ; 14(7): 2030-41, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25887394

RESUMO

The field of proteomics has evolved hand-in-hand with technological advances in LC-MS/MS systems, now enabling the analysis of very deep proteomes in a reasonable time. However, most applications do not deal with full cell or tissue proteomes but rather with restricted subproteomes relevant for the research context at hand or resulting from extensive fractionation. At the same time, investigation of many conditions or perturbations puts a strain on measurement capacity. Here, we develop a high-throughput workflow capable of dealing with large numbers of low or medium complexity samples and specifically aim at the analysis of 96-well plates in a single day (15 min per sample). We combine parallel sample processing with a modified liquid chromatography platform driving two analytical columns in tandem, which are coupled to a quadrupole Orbitrap mass spectrometer (Q Exactive HF). The modified LC platform eliminates idle time between measurements, and the high sequencing speed of the Q Exactive HF reduces required measurement time. We apply the pipeline to the yeast chromatin remodeling landscape and demonstrate quantification of 96 pull-downs of chromatin complexes in about 1 day. This is achieved with only 500 µg input material, enabling yeast cultivation in a 96-well format. Our system retrieved known complex-members and the high throughput allowed probing with many bait proteins. Even alternative complex compositions were detectable in these very short gradients. Thus, sample throughput, sensitivity and LC/MS-MS duty cycle are improved severalfold compared with established workflows. The pipeline can be extended to different types of interaction studies and to other medium complexity proteomes.


Assuntos
Cromatografia Líquida/métodos , Mapeamento de Interação de Proteínas/métodos , Saccharomyces cerevisiae/metabolismo , Espectrometria de Massas em Tandem/métodos , Montagem e Desmontagem da Cromatina , Cromatografia Líquida de Alta Pressão , Reprodutibilidade dos Testes , Proteínas de Saccharomyces cerevisiae/metabolismo , Fatores de Tempo
5.
Mol Cell Proteomics ; 14(7): 2014-29, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25991688

RESUMO

Hybrid quadrupole time-of-flight (QTOF) mass spectrometry is one of the two major principles used in proteomics. Although based on simple fundamentals, it has over the last decades greatly evolved in terms of achievable resolution, mass accuracy, and dynamic range. The Bruker impact platform of QTOF instruments takes advantage of these developments and here we develop and evaluate the impact II for shotgun proteomics applications. Adaption of our heated liquid chromatography system achieved very narrow peptide elution peaks. The impact II is equipped with a new collision cell with both axial and radial ion ejection, more than doubling ion extraction at high tandem MS frequencies. The new reflectron and detector improve resolving power compared with the previous model up to 80%, i.e. to 40,000 at m/z 1222. We analyzed the ion current from the inlet capillary and found very high transmission (>80%) up to the collision cell. Simulation and measurement indicated 60% transfer into the flight tube. We adapted MaxQuant for QTOF data, improving absolute average mass deviations to better than 1.45 ppm. More than 4800 proteins can be identified in a single run of HeLa digest in a 90 min gradient. The workflow achieved high technical reproducibility (R2 > 0.99) and accurate fold change determination in spike-in experiments in complex mixtures. Using label-free quantification we rapidly quantified haploid against diploid yeast and characterized overall proteome differences in mouse cell lines originating from different tissues. Finally, after high pH reversed-phase fractionation we identified 9515 proteins in a triplicate measurement of HeLa peptide mixture and 11,257 proteins in single measurements of cerebellum-the highest proteome coverage reported with a QTOF instrument so far.


Assuntos
Proteômica/instrumentação , Proteômica/métodos , Animais , Linhagem Celular , Cromatografia Líquida , Diploide , Haploidia , Células HeLa , Humanos , Concentração de Íons de Hidrogênio , Íons , Espectrometria de Massas , Camundongos , Peso Molecular , Peptídeos/metabolismo , Proteoma/metabolismo , Reprodutibilidade dos Testes , Saccharomyces cerevisiae/metabolismo , Fatores de Tempo
6.
Front Pharmacol ; 9: 699, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30022949

RESUMO

Idiosyncratic drug-induced liver injury (iDILI) is a major cause of acute liver failure resulting in liver transplantation or death. Prediction and diagnosis of iDILI remain a great challenge, as current models provide unsatisfying results in terms of sensitivity, specificity, and prognostic value. The absence of appropriate tools for iDILI detection also impairs the development of reliable biomarkers. Here, we report on a new method for identification of drug-specific biomarkers. We combined the advantages of monocyte-derived hepatocyte-like (MH) cells, able to mimic individual characteristics, with those of a novel mass spectrometry-based proteomics technology to assess potential biomarkers for Diclofenac-induced DILI. We found over 2,700 proteins differentially regulated in MH cells derived from individual patients. Herefrom, we identified integrin beta 3 (ITGB3) to be specifically upregulated in Diclofenac-treated MH cells from Diclofenac-DILI patients compared to control groups. Finally, we validated ITGB3 by flow cytometry analysis of whole blood and histological staining of liver biopsies derived from patients diagnosed with Diclofenac-DILI. In summary, our results show that biomarker candidates can be identified by proteomics analysis of MH cells. Application of this method to a broader range of drugs in the future will exploit its full potential for the development of drug-specific biomarkers. Data are available via ProteomeXchange with identifier PXD008918.

7.
Cell Syst ; 2(3): 185-95, 2016 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-27135364

RESUMO

Proteins in the circulatory system mirror an individual's physiology. In daily clinical practice, protein levels are generally determined using single-protein immunoassays. High-throughput, quantitative analysis using mass-spectrometry-based proteomics of blood, plasma, and serum would be advantageous but is challenging because of the high dynamic range of protein abundances. Here, we introduce a rapid and robust "plasma proteome profiling" pipeline. This single-run shotgun proteomic workflow does not require protein depletion and enables quantitative analysis of hundreds of plasma proteomes from 1 µl single finger pricks with 20 min gradients. The apolipoprotein family, inflammatory markers such as C-reactive protein, gender-related proteins, and >40 FDA-approved biomarkers are reproducibly quantified (CV <20% with label-free quantification). Furthermore, we functionally interpret a 1,000-protein, quantitative plasma proteome obtained by simple peptide pre-fractionation. Plasma proteome profiling delivers an informative portrait of a person's health state, and we envision its large-scale use in biomedicine.


Assuntos
Proteoma , Biomarcadores , Proteínas Sanguíneas , Cromatografia Líquida , Perfilação da Expressão Gênica , Humanos , Espectrometria de Massas , Proteômica , Espectrometria de Massas em Tandem
8.
Nat Commun ; 7: 12429, 2016 08 19.
Artigo em Inglês | MEDLINE | ID: mdl-27539542

RESUMO

Circular RNAs (circRNAs) are broadly expressed in eukaryotic cells, but their molecular mechanism in human disease remains obscure. Here we show that circular antisense non-coding RNA in the INK4 locus (circANRIL), which is transcribed at a locus of atherosclerotic cardiovascular disease on chromosome 9p21, confers atheroprotection by controlling ribosomal RNA (rRNA) maturation and modulating pathways of atherogenesis. CircANRIL binds to pescadillo homologue 1 (PES1), an essential 60S-preribosomal assembly factor, thereby impairing exonuclease-mediated pre-rRNA processing and ribosome biogenesis in vascular smooth muscle cells and macrophages. As a consequence, circANRIL induces nucleolar stress and p53 activation, resulting in the induction of apoptosis and inhibition of proliferation, which are key cell functions in atherosclerosis. Collectively, these findings identify circANRIL as a prototype of a circRNA regulating ribosome biogenesis and conferring atheroprotection, thereby showing that circularization of long non-coding RNAs may alter RNA function and protect from human disease.


Assuntos
Aterosclerose/genética , Aterosclerose/metabolismo , RNA Longo não Codificante/metabolismo , RNA Ribossômico/metabolismo , Apoptose , Aterosclerose/patologia , Nucléolo Celular/metabolismo , Proliferação de Células , Cromossomos Humanos Par 9 , Repetições Palindrômicas Curtas Agrupadas e Regularmente Espaçadas , Inibidor de Quinase Dependente de Ciclina p15/genética , Inibidor de Quinase Dependente de Ciclina p15/metabolismo , Inibidor p16 de Quinase Dependente de Ciclina , Inibidor de Quinase Dependente de Ciclina p18/genética , Inibidor de Quinase Dependente de Ciclina p18/metabolismo , Perfilação da Expressão Gênica , Células HEK293 , Humanos , Macrófagos/patologia , Músculo Liso Vascular/metabolismo , Proteínas/metabolismo , Processamento Pós-Transcricional do RNA , RNA Longo não Codificante/genética , RNA Ribossômico/genética , Proteínas de Ligação a RNA
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA