Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Radiology ; 297(3): 699-707, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32990514

RESUMO

Background There is a wide variation in radiation dose levels that can be used with chest CT in order to detect indeterminate pulmonary nodules. Purpose To compare the performance of lower-radiation-dose chest CT with that of routine dose in the detection of indeterminate pulmonary nodules 5 mm or greater. Materials and Methods In this retrospective study, CT projection data from 83 routine-dose chest CT examinations performed in 83 patients (120 kV, 70 quality reference mAs [QRM]) were collected between November 2013 and April 2014. Reference indeterminate pulmonary nodules were identified by two nonreader thoracic radiologists. By using validated noise insertion, five lower-dose data sets were reconstructed with filtered back projection (FBP) or iterative reconstruction (IR; 30 QRM with FBP, 10 QRM with IR, 5 QRM with FBP, 5 QRM with IR, and 2.5 QRM with IR). Three thoracic radiologists circled pulmonary nodules, rating confidence that the nodule was a 5-mm-or-greater indeterminate pulmonary nodule, and graded image quality. Analysis was performed on a per-nodule basis by using jackknife alternative free-response receiver operating characteristic figure of merit (FOM) and noninferiority limit of -0.10. Results There were 66 indeterminate pulmonary nodules (mean size, 8.6 mm ± 3.4 [standard deviation]; 21 part-solid nodules) in 42 patients (mean age, 51 years ± 17; 21 men and 21 women). Compared with the FOM for routine-dose CT (size-specific dose estimate, 6.5 mGy ± 1.8; FOM, 0.86 [95% confidence interval: 0.80, 0.91]), FOM was noninferior for all lower-dose configurations except for 2.5 QRM with IR. The sensitivity for subsolid nodules at 70 QRM was 60% (range, 48%-72%) and was significantly worse at a dose of 5 QRM and lower, whether or not IR was used (P < .05). Diagnostic image quality decreased with decreasing dose (P < .001) and was better with IR at 5 QRM (P < .05). Conclusion CT images reconstructed at dose levels down to 10 quality reference mAs (size-specific dose estimate, 0.9 mGy) had noninferior performance compared with routine dose in depicting pulmonary nodules. Iterative reconstruction improved subjective image quality but not performance at low dose levels. © RSNA, 2020 Online supplemental material is available for this article. See also the editorial by White and Kazerooni in this issue.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Variações Dependentes do Observador , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Torácica , Estudos Retrospectivos , Nódulo Pulmonar Solitário/diagnóstico por imagem
3.
Infect Control Hosp Epidemiol ; 41(12): 1375-1377, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32669150

RESUMO

OBJECTIVE: Presently, evidence guiding clinicians on the optimal approach to safely screen patients for coronavirus disease 2019 (COVID-19) to a nonemergent hospital procedure is scarce. In this report, we describe our experience in screening for SARS-CoV-2 prior to semiurgent and urgent hospital procedures. DESIGN: Retrospective case series. SETTING: A single tertiary-care medical center. PARTICIPANTS: Our study cohort included patients ≥18 years of age who had semiurgent or urgent hospital procedures or surgeries. METHODS: Overall, 625 patients were screened for SARS-CoV-2 using a combination of phone questionnaire (7 days prior to the anticipated procedure), RT-PCR and chest computed tomography (CT) between March 1, 2020, and April 30, 2020. RESULTS: Of the 625 patients, 520 scans (83.2%) were interpreted as normal; 1 (0.16%) had typical features of COVID-19; 18 scans (2.88%) had indeterminate features of COVID-19; and 86 (13.76%) had atypical features of COVID-19. In total, 640 RT-PCRs were performed, with 1 positive result (0.15%) in a patient with a CT scan that yielded an atypical finding. Of the 18 patients with chest CTs categorized as indeterminate, 5 underwent repeat negative RT-PCR nasopharyngeal swab 1 week after their initial swab. Also, 1 patient with a chest CT categorized as typical had a follow-up repeat negative RT-PCR, indicating that the chest CT was likely a false positive. After surgery, none of the patients developed signs or symptoms suspicious of COVID-19 that would indicate the need for a repeated RT-PCR or CT scan. CONCLUSION: In our experience, chest CT scanning did not prove provide valuable information in detecting asymptomatic cases of SARS-CoV-2 (COVID-19) in our low-prevalence population.


Assuntos
Teste de Ácido Nucleico para COVID-19 , COVID-19 , Controle de Infecções/métodos , Pneumonia Viral/diagnóstico , SARS-CoV-2/isolamento & purificação , Adulto , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/prevenção & controle , Teste de Ácido Nucleico para COVID-19/métodos , Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , Prática Clínica Baseada em Evidências , Reações Falso-Positivas , Feminino , Humanos , Masculino , Programas de Rastreamento/métodos , Programas de Rastreamento/normas , Minnesota/epidemiologia , Pneumonia Viral/etiologia , Gestão da Segurança , Centro Cirúrgico Hospitalar/organização & administração , Tomografia Computadorizada por Raios X/métodos , Tomografia Computadorizada por Raios X/normas , Tomografia Computadorizada por Raios X/estatística & dados numéricos
4.
J Investig Med High Impact Case Rep ; 6: 2324709617752962, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29435464

RESUMO

Erdheim-Chester disease is a rare non-Langerhans cell histiocytosis with multisystem involvement and insidious symptoms. In this article, we describe an interesting case of Erdheim-Chester disease that was eventually diagnosed 8 years after symptoms initially started.

5.
Br J Radiol ; 91(1088): 20170600, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29485899

RESUMO

The diaphragm is an unique skeletal muscle separating the thoracic and abdominal cavities with a primary function of enabling respiration. When abnormal, whether by congenital or acquired means, the consequences for patients can be severe. Abnormalities that affect the diaphragm are often first detected on chest radiographs as an alteration in position or shape. Cross-sectional imaging studies, primarily CT and occasionally MRI, can depict structural defects, intrinsic and adjacent pathology in greater detail. Fluoroscopy is the primary radiologic means of evaluating diaphragmatic motion, though MRI and ultrasound also are capable of this function. This review provides an update on diaphragm embryogenesis and discusses current imaging of various abnormalities, including the emerging role of three-dimensional printing in planning surgical repair of diaphragmatic derangements.


Assuntos
Diafragma/diagnóstico por imagem , Diafragma/embriologia , Diafragma/anormalidades , Humanos
6.
J Thorac Imaging ; 33(6): 396-401, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30048344

RESUMO

PURPOSE: The aim of this study was to evaluate the ability of computer-aided detection (CAD) and human readers to detect pulmonary nodules ≥5 mm using 100 kV ultra-low-dose computed tomography (ULDCT) utilizing a tin filter. MATERIALS AND METHODS: After informed consent, 55 patients prospectively underwent standard-dose chest CT (SDCT) using 120 kV followed by ULDCT using 100 kV/tin. Reference nodules ≥5 mm were identified by a thoracic radiologist using SDCT. Four thoracic radiologists marked detected nodules on SDCT and ULDCT examinations using a dedicated computer workstation. After a 6-month memory extinction, readers were shown the same ULDCT cases with all CAD markings as well as their original detections, and characterized CAD detections as true positive or false positive. RESULTS: Volume CT Dose index (CTDIvol) for SDCT and ULDCT were 5.3±2 and 0.4±0.2 mGy (P<0.0001), respectively. Forty-five reference nodules were detected in 30 patients. Reader sensitivity varied widely but similarly for SDCT (ranging from 45% to 87%) and ULDCT (45% to 83%). CAD sensitivity was 76% (34/45) for SDCT and 71% (32/45) for ULDCT. After CAD, reader sensitivity substantially improved by 19% and 18% for 2 readers, and remained nearly unchanged for the other 2 readers (0% and 2%), despite reader perception that many more nodules were identified with CAD. There was a mean of 2 false-positive CAD detections/case. CONCLUSIONS: ULDCT with 100 kV/tin reduced patient dose by over 90% without compromising pulmonary nodule detection sensitivity. CAD can substantially improve nodule detection sensitivity at ULDCT for some readers, maintaining interobserver performance.


Assuntos
Aumento da Imagem/métodos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Humanos , Pulmão/diagnóstico por imagem , Projetos Piloto , Estudos Prospectivos , Doses de Radiação , Sensibilidade e Especificidade
7.
AJR Am J Roentgenol ; 188(3): 839-42, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17312076

RESUMO

OBJECTIVE: Transient interruption of the contrast bolus has been described as a physiologic artifact that can sometimes result in poor opacification of the pulmonary arteries on pulmonary CT angiographic studies. To better understand the mechanism underlying this artifact, we used velocity-encoded cine MRI to measure flow in the inferior vena cava (IVC) and superior vena cava (SVC) during respiratory maneuvers. SUBJECTS AND METHODS: Quantitative measurements of SVC and IVC flow per R-R interval were performed on 10 healthy volunteers (six men, four women; median age, 30 years; range, 25-55 years) with a retrospectively ECG-gated velocity-encoded gradient-echo cine sequence on a 1.5-T MRI unit with axial slices at the level of the diaphragm and just below the azygous vein confluence during free breathing, continuous inspiration, breath-hold at end inspiration, Valsalva maneuver, and breath-hold at end expiration. RESULTS: Median flow during free breathing was 38.9 mL in the SVC and 74.3 mL in the IVC, during continuous inspiration was 43.9 mL in the SVC and 113.7 mL in the IVC, during breath-hold at end inspiration was 31.0 mL in the SVC and 56.1 mL in the IVC, during a Valsalva maneuver was 28.9 mL in the SVC and 53.9 mL in the IVC, and during breath-hold at end expiration was 35.3 mL in the SVC and 61.2 mL in the IVC. CONCLUSION: MRI measurements showed a significant increase in caval flow during inspiration and a greater relative increase in blood flow in the IVC than in the SVC. For thoracic CT performed with IV contrast enhancement, deep inspiration before scanning leads to a large influx of IVC blood that does not contain contrast medium and dilutes the contrast bolus, causing poor vascular opacification. Avoiding initial inspiration before scanning is suggested as a way to limit the transient interruption of the contrast bolus artifact.


Assuntos
Artefatos , Velocidade do Fluxo Sanguíneo/fisiologia , Imageamento por Ressonância Magnética/métodos , Artéria Pulmonar/diagnóstico por imagem , Circulação Pulmonar/fisiologia , Mecânica Respiratória , Veias Cavas/fisiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Artéria Pulmonar/fisiologia , Radiografia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Veias Cavas/anatomia & histologia
8.
J Med Imaging (Bellingham) ; 4(1): 013510, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28401176

RESUMO

Task-based assessment of computed tomography (CT) image quality requires a large number of cases with ground truth. Prospective case acquisition can be time-consuming. Inserting lesions into existing cases to simulate positive cases is a promising alternative. The aim was to evaluate a recently developed projection-based lesion insertion technique in thoracic CT. In total, 32 lung nodules of various attenuations were segmented from 21 patient cases, forward projected, inserted into projections, and reconstructed. Two experienced radiologists and two residents independently evaluated these nodules in two substudies. First, the 32 inserted and the 32 original nodules were presented in a randomized order and each received a score from 1 to 10 (1 = absolutely artificial to 10 = absolutely realistic). Second, the inserted and the corresponding original lesions were presented side-by-side to each reader. For the randomized evaluation, discrimination of real versus inserted nodules was poor with areas under the receiver operative characteristic curves being 0.57 [95% confidence interval (CI): 0.46 to 0.68], 0.69 (95% CI: 0.58 to 0.78), and 0.62 (95% CI: 0.54 to 0.69) for the two residents, two radiologists, and all four readers, respectively. Our projection-based lung nodule insertion technique provides a robust method to artificially generate positive cases that prove to be difficult to differentiate from real cases.

9.
Semin Ultrasound CT MR ; 27(1): 42-55, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16562571

RESUMO

Computed tomographic coronary angiography (CT-CA) is a direct but minimally invasive method of visualizing coronary arteries. Multidetector-row computed tomography (MDCT) is currently the CT modality most commonly used for coronary artery imaging. MDCT has been successfully used to detect stenoses in coronary arteries and coronary artery bypass grafts and to assess congenital coronary anomalies. Patients should not undergo CT-CA with MDCT if they have an irregular heart rhythm, a heart rate greater than 70 beats/min, and contraindications to pharmacologic agents for heart rate control, or if they have severe coronary artery disease or are likely to require revascularization.


Assuntos
Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Ponte de Artéria Coronária , Humanos , Processamento de Imagem Assistida por Computador , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação
10.
Artigo em Inglês | MEDLINE | ID: mdl-27695156

RESUMO

Task-based assessment of computed tomography (CT) image quality requires a large number of cases with ground truth. Inserting lesions into existing cases to simulate positive cases is a promising alternative approach. The aim of this study was to evaluate a recently-developed raw-data based lesion insertion technique in thoracic CT. Lung lesions were segmented from patient CT images, forward projected, and reinserted into the same patient CT projection data. In total, 32 nodules of various attenuations were segmented from 21 CT cases. Two experienced radiologists and 2 residents blinded to the process independently evaluated these inserted nodules in two sub-studies. First, the 32 inserted and the 32 original nodules were presented in a randomized order and each received a rating score from 1 to 10 (1=absolutely artificial to 10=absolutely realistic). Second, the inserted and the corresponding original lesions were presented side-by-side to each reader, who identified the inserted lesion and provided a confidence score (1=no confidence to 5=completely certain). For the randomized evaluation, discrimination of real versus artificial nodules was poor with areas under the receiver operative characteristic curves being 0.69 (95% CI: 0.58-0.78), 0.57 (95% CI: 0.46-0.68), and 0.62 (95% CI: 0.54-0.69) for the 2 radiologists, 2 residents, and all 4 readers, respectively. For the side-by-side evaluation, although all 4 readers correctly identified inserted lesions in 103/128 pairs, the confidence score was moderate (2.6). Our projection-domain based lung nodule insertion technique provides a robust method to artificially generate clinical cases that prove to be difficult to differentiate from real cases.

11.
Invest Radiol ; 40(8): 556-63, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-16024994

RESUMO

RATIONALE AND OBJECTIVES: We sought to examine effects of tube voltage and current on radiation dose and image quality for minimally invasive coronary angiography with a 16-slice multidetector row computed tomography (MDCT) scanner. MATERIALS AND METHODS: We scanned the phantom used in the American College of Radiology Computed Tomography Accreditation Program at tube voltages of 80 and 120 kVp at 550, 650, and 750 mAseff, with and without a reduction in radiation dose by electrocardiographically (ECG) controlled tube current modulation (ECG pulsing). RESULTS: Without ECG pulsing, the effective dose was 3 to 13 mSv. On average, a 50% increase in tube voltage led to increased radiation dose (215%), contrast-to-noise ratio (150%), and decreased image noise (-48%). On average, a 17% increase in mAseff led to increased radiation dose (17%) and contrast-to-noise ratio (4%) and decreased image noise (-9%). Dose reduction by ECG pulsing (simulated heart rate, 70 beats per minute) was 28%. With ECG pulsing, noise in images reconstructed during ventricular systole was double that in images reconstructed during ventricular diastole. CONCLUSIONS: These quantitative findings about the relationships among scan acquisition parameters, radiation dose, and image quality have practical implications for using ECG pulsing to reduce radiation doses in MDCT coronary angiography.


Assuntos
Angiografia Coronária/métodos , Doses de Radiação , Tomografia Computadorizada Espiral , Algoritmos , Eletrocardiografia , Processamento de Imagem Assistida por Computador , Modelos Lineares , Imagens de Fantasmas
12.
Mayo Clin Proc ; 79(8): 1017-23, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15301329

RESUMO

OBJECTIVE: To describe a single-center experience of using retrospectively gated multislice computed tomographic (MSCT) coronary angiography for imaging congenital coronary anomalies. PATIENTS AND METHODS: We retrospectively reviewed the clinical information and imaging studies for 9 patients diagnosed as having congenital coronary anomalies on invasive, selective coronary angiography between February 2001 and October 2003 at the Mayo Clinic in Jacksonville, Fla. Two experienced observers classified by consensus the origin and proximal course of the abnormal coronary arteries as seen on MSCT. RESULTS: In 1 patient, MSCT showed a normal but extremely anterior origin of the right coronary artery from the right aortic sinus of Valsalva. In the other 8 patients, the origin and course of 4 anomalous right coronary arteries, 2 anomalous left circumflex coronary arteries, and 2 single coronary arteries were recognized easily on MSCT. CONCLUSION: Similar to electron beam computed tomography and magnetic resonance imaging, widely available MSCT can characterize the proximal course of congenitally abnormal coronary arteries and thus aid in clinical decision making for patients with such anomalies.


Assuntos
Angiografia Coronária/métodos , Anomalias dos Vasos Coronários/diagnóstico por imagem , Tomografia Computadorizada Espiral/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Angina Pectoris/etiologia , Fármacos Cardiovasculares/uso terapêutico , Angiografia Coronária/instrumentação , Angiografia Coronária/normas , Ponte de Artéria Coronária , Anomalias dos Vasos Coronários/complicações , Anomalias dos Vasos Coronários/terapia , Dispneia/etiologia , Feminino , Florida , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Retrospectivos , Tomografia Computadorizada Espiral/instrumentação , Tomografia Computadorizada Espiral/normas
13.
Mayo Clin Proc ; 77(1): 55-71, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11794459

RESUMO

Electron beam computed tomography (EBCT) is the reference standard for x-ray-based tomographic imaging of the heart because of its high temporal resolution, but it is available in only a few centers. Quantification of coronary calcium is the most widely recognized use of EBCT for cardiac imaging. This technique requires no contrast media and provides an accurate assessment of overall plaque burden in the coronary tree; however, it does not directly identify or localize coronary stenoses. Multislice spiral (helical) CT (MSCT) is a new technology that provides images of the beating heart in diagnostic quality under many circumstances and may facilitate the broader application of cardiac and coronary CT. Currently, for imaging of the heart, much more experience exists with EBCT than with MSCT. Contrast-enhanced CT coronary angiography (CTCA) can be done with EBCT or MSCT to obtain images of the major branches of the coronary tree and to define luminal narrowing. Studies at experienced centers performed with small numbers of patients show that sensitivity, specificity, and negative predictive value are good with CTCA in the assessment of obstructive coronary artery disease, but CTCA remains an investigational technique for these applications. Computed tomographic coronary angiography can be clinically useful for assessing coronary artery bypass graft patency and congenital coronary abnormalities.


Assuntos
Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Ponte de Artéria Coronária , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional
14.
Invest Radiol ; 38(2): 108-18, 2003 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-12544074

RESUMO

RATIONALE AND OBJECTIVES: To search for an optimum reconstruction window in retrospectively gated multislice computed tomography (MSCT) for quantification of coronary calcium. MATERIALS AND METHODS: Coronary calcium quantified was examined as Agatston and volume scores by two experienced observers at 10 time points across the R-R interval of the electrocardiogram in 42 patients. A combination of statistical approaches was used to evaluate the distributions of minimum and maximum scores and of interobserver variability for both scoring methods across the cardiac cycle. RESULTS: Based on the combination of evaluation approaches, 60% to 70% of the R-R interval appeared to be the optimum time point for obtaining maximum calcium scores with minimum interobserver variability. The optimum time point was more clearly defined for the Agatston score than for the volume score. CONCLUSION: A reconstruction window beginning at 60% to 70% of the R-R interval seems to be most advantageous for retrospective gating of MSCT studies performed to quantify coronary calcium.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Distribuição de Qui-Quadrado , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Variações Dependentes do Observador , Estudos Retrospectivos
15.
Case Rep Radiol ; 2014: 196960, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25580344

RESUMO

A 67-year-old male presented to the emergency department with concern for accidental aspiration of an aluminum beverage can pull tab. Neck and chest radiographs did not reveal an aspirated foreign body. Despite ongoing complaint of dysgeusia and adamancy of aspiration by the patient, he was discharged to home without recommendation for further follow-up. Seven months later, a computed tomography (CT) scan of the chest performed as part of an unrelated lung cancer work up confirmed the presence of a left mainstem bronchus metallic foreign body compatible with a pull tab. This case report illustrates the poor negative predictive value of radiographs for a suspected aluminum foreign body and demonstrates the superiority of CT for this purpose. In such presentations it is imperative to have a low threshold for performing further diagnostic evaluation with CT due to the relatively high radiolucency of aluminum.

18.
Heart Metab ; 34: 5-9, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-20011235

RESUMO

Coronary computed tomographic angiography (CCTA) is a direct but minimally invasive method of visualizing coronary arteries. Acceptable indications for this technique include the assessment of suspected or known coronary artery anomalies, the evaluation of chest pain syndromes in patients with non diagnostic stress tests or who are unable to exercise, and exclusion of an ischemic etiology in patients with unexplained left ventricular dysfunction. Assessment of coronary stents with a diameter of <3.0 mm and imaging of asymptomatic patients with a goal of establishing prognosis are currently not accepted indications for CCTA.

19.
Eur Radiol ; 16(3): 551-9, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16215736

RESUMO

OBJECTIVE: To assess functional parameters using multidetector-row computed tomography (MDCT) and echocardiography and to compare the results with magnetic resonance imaging (MRI). MATERIALS AND METHODS: End-diastolic-volume (EDV), end-systolic-volume (ESV), stroke-volume (SV), ejection-fraction (EF), and myocardial mass (MM) were calculated based on CT data sets from 52 patients. Echocardiography was performed in 24 of the 52 patients. The results from MDCT and echocardiography were compared with MRI. RESULTS: A strong correlation between MDCT and MRI (r=0.66-0.90) was found for all parameters. Echocardiography revealed a low or moderate correlation (0.05-0.59). Compared to MRI the average differences with MDCT were for EDV 15.1 ml, ESV 10.6 ml, SV 4.5 ml, EF 1.8%, and MM 8.2 g, for EDV determined by echocardiography 36.2 ml, ESV 6.8 ml, and EF 13.9%. Bland-Altman analysis revealed acceptable limits of agreement between MRI and MDCT. CONCLUSIONS: MDCT enables reliable quantification of left ventricular function. Echocardiography was found to have only a moderate agreement of functional parameters with MRI.


Assuntos
Disfunção Ventricular Esquerda/diagnóstico , Angiografia Coronária , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X
20.
Int J Cardiovasc Imaging ; 21(1): 165-76, 2005 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15915949

RESUMO

With increasing clinical use of cardiac CT imaging it is important that all health care providers referring for or administering such examinations are familiar with the concepts and values of radiation dosimetry in CT as well as with the basic principles of radiation protection. There are important technical differences pertinent to radiation dose between the CT scanner types that are currently being used for imaging of the heart and coronary arteries. As a result of these differences, the radiation dose typically is higher when a cardiac examination is performed with multidetector-row CT (MDCT) than when it is performed with electron beam CT. Several techniques have been described to reduce radiation dose of MDCT imaging by varying the X-ray tube current during a CT examination. The volume computed tomographic dose index (CTDIvol), the dose length product (DLP), and the effective dose (E) are the most useful parameters to describe and compare radiation doses received from cardiac CT examinations. When comparing radiation doses between scanning protocols and scanner types, the degree of image noise must be considered. Diagnostic, rather than aesthetic, quality of images should be the most important factor guiding the development of scanning protocols for cardiac CT imaging. Cardiac CT examinations should be ordered only by qualified health care providers, and the ordering clinicians should be aware of their responsibility of weighing risks of the radiation exposure against the expected benefits.


Assuntos
Coração/diagnóstico por imagem , Doses de Radiação , Monitoramento de Radiação/métodos , Tomografia Computadorizada por Raios X , Humanos , Imagens de Fantasmas , Proteção Radiológica , Radiografia Torácica , Dosimetria Termoluminescente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA