Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Nat Methods ; 19(9): 1137-1146, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36050489

RESUMO

Antibodies have diverse applications due to their high reaction specificities but are sensitive to denaturation when a higher working temperature is required. We have developed a simple, highly scalable and generalizable chemical approach for stabilizing off-the-shelf antibodies against thermal and chemical denaturation. We demonstrate that the stabilized antibodies (termed SPEARs) can withstand up to 4 weeks of continuous heating at 55 °C and harsh denaturants, and apply our method to 33 tested antibodies. SPEARs enable flexible applications of thermocycling and denaturants to dynamically modulate their binding kinetics, reaction equilibrium, macromolecular diffusivity and aggregation propensity. In particular, we show that SPEARs permit the use of a thermally facilitated three-dimensional immunolabeling strategy (termed ThICK staining), achieving whole mouse brain immunolabeling within 72 h, as well as nearly fourfold deeper penetration with threefold less antibodies in human brain tissue. With faster deep-tissue immunolabeling and broad compatibility with tissue processing and clearing methods without the need for any specialized equipment, we anticipate the wide applicability of ThICK staining with SPEARs for deep immunostaining.


Assuntos
Anticorpos , Encéfalo , Animais , Anticorpos/metabolismo , Encéfalo/metabolismo , Humanos , Camundongos
2.
Proc IEEE Inst Electr Electron Eng ; 110(7): 968-992, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35756185

RESUMO

Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of target anatomy, surrounding tissue, and instrumentation, but there are significant challenges in harnessing it for effectively guiding interventional procedures. Challenges include the strong static magnetic field, rapidly switching magnetic field gradients, high-power radio frequency pulses, sensitivity to electrical noise, and constrained space to operate within the bore of the scanner. MRI has a number of advantages over other medical imaging modalities, including no ionizing radiation, excellent soft-tissue contrast that allows for visualization of tumors and other features that are not readily visible by other modalities, true 3-D imaging capabilities, including the ability to image arbitrary scan plane geometry or perform volumetric imaging, and capability for multimodality sensing, including diffusion, dynamic contrast, blood flow, blood oxygenation, temperature, and tracking of biomarkers. The use of robotic assistants within the MRI bore, alongside the patient during imaging, enables intraoperative MR imaging (iMRI) to guide a surgical intervention in a closed-loop fashion that can include tracking of tissue deformation and target motion, localization of instrumentation, and monitoring of therapy delivery. With the ever-expanding clinical use of MRI, MRI-compatible robotic systems have been heralded as a new approach to assist interventional procedures to allow physicians to treat patients more accurately and effectively. Deploying robotic systems inside the bore synergizes the visual capability of MRI and the manipulation capability of robotic assistance, resulting in a closed-loop surgery architecture. This article details the challenges and history of robotic systems intended to operate in an MRI environment and outlines promising clinical applications and associated state-of-the-art MRI-compatible robotic systems and technology for making this possible.

3.
Ann Surg Oncol ; 28(1): 363-375, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32572853

RESUMO

BACKGROUND: Surgeons are pursuing accurate head and neck reconstruction to enhance aesthetic and functional outcomes after oncologic resection. This study aimed to investigate whether accuracy of head and neck reconstruction is improved with the use of three-dimensionally (3D)-printed patient-specific surgical plates compared with conventional plates. METHODS: In this comparative study, patients were prospectively recruited into the study group (3DJP16) with 3D-printed patient-specific surgical plates. The patients in control group with conventional surgical plates were from a historic cohort in the same unit. The primary end point of the study was the accuracy of head and neck reconstruction. The secondary end points were accuracy of osteotomy, intraoperative blood loss, total operative time, and length of hospital stay. RESULTS: The study recruited of 33 patients, including 17 in the study group and 16 in the control group. The patients' baseline characteristics were similar between the two groups. The absolute distance deviation of the maxilla or mandible was 1.5 ± 0.5 mm in the study group and 2.1 ± 0.7 mm in the control group [mean difference, - 0.7 mm; 95% confidence interval (CI) - 1.1 to - 0.3; p = 0.003], showing superior accuracy of reconstruction for the patients with 3D-printed patient-specific surgical plates. Improved accuracy of reconstruction also was detected in terms of bilateral mandibular angles and bone grafts. Concerning the secondary end points, the accuracy of the osteotomy was similar in the two groups. No difference was found regarding intraoperative blood loss, total operative time, or length of hospital stay. CONCLUSIONS: This is the first study to prove that compared with conventional plates, 3D-printed patient-specific surgical plates improve the accuracy of oncologic head and neck reconstruction.


Assuntos
Reconstrução Mandibular , Procedimentos de Cirurgia Plástica , Cirurgia Assistida por Computador , Placas Ósseas , Humanos , Mandíbula/cirurgia , Impressão Tridimensional
4.
IEEE ASME Trans Mechatron ; 21(2): 956-962, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28989272

RESUMO

Active magnetic resonance (MR) tracking for gynecologic brachytherapy was made possible by attaching the micro radiofrequency coils to the brachytherapy applicator. The rectangular planar micro coil was fabricated using flexible printed circuits with dimensions of 8mm×1.5mm. A 5-Fr (1.6mm) tungsten brachytherapy stylet was custom-machined to incorporate the micro coils. The finite element analysis and the phantom tissue studies show that the proposed device enables in situ, real-time guidance of access routes to the target anatomy safely and accurately. The setup was tested in a Siemens 3T MR scanner. The micro coils can be localized rapidly (up to 40 Hz) and precisely (resolution: 0.6×0.6×0.6mm3) using an MR-tracking sequence.

5.
IEEE Trans Med Imaging ; 43(1): 439-448, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37647176

RESUMO

We present a design of an inductively coupled radio frequency (ICRF) marker for magnetic resonance (MR)-based positional tracking, enabling the robust increase of tracking signal at all scanning orientations in quadrature-excited closed MR imaging (MRI). The marker employs three curved resonant circuits fully covering a cylindrical surface that encloses the signal source. Each resonant circuit is a planar spiral inductor with parallel plate capacitors fabricated monolithically on flexible printed circuit board (FPC) and bent to achieve the curved structure. Size of the constructed marker is Ø3-mm ×5 -mm with quality factor > 22, and its tracking performance was validated with 1.5 T MRI scanner. As result, the marker remains as a high positive contrast spot under 360° rotations in 3 axes. The marker can be accurately localized with a maximum error of 0.56 mm under a displacement of 56 mm from the isocenter, along with an inherent standard deviation of 0.1-mm. Accrediting to the high image contrast, the presented marker enables automatic and real-time tracking in 3D without dependency on its orientation with respect to the MRI scanner receive coil. In combination with its small form-factor, the presented marker would facilitate robust and wireless MR-based tracking for intervention and clinical diagnosis. This method targets applications that can involve rotational changes in all axes (X-Y-Z).


Assuntos
Imageamento por Ressonância Magnética , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética , Imagens de Fantasmas
6.
Adv Sci (Weinh) ; 11(7): e2305495, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38072667

RESUMO

Magnetic resonance imaging (MRI) demonstrates clear advantages over other imaging modalities in neurosurgery with its ability to delineate critical neurovascular structures and cancerous tissue in high-resolution 3D anatomical roadmaps. However, its application has been limited to interventions performed based on static pre/post-operative imaging, where errors accrue from stereotactic frame setup, image registration, and brain shift. To leverage the powerful intra-operative functions of MRI, e.g., instrument tracking, monitoring of physiological changes and tissue temperature in MRI-guided bilateral stereotactic neurosurgery, a multi-stage robotic positioner is proposed. The system positions cannula/needle instruments using a lightweight (203 g) and compact (Ø97 × 81 mm) skull-mounted structure that fits within most standard imaging head coils. With optimized design in soft robotics, the system operates in two stages: i) manual coarse adjustment performed interactively by the surgeon (workspace of ±30°), ii) automatic fine adjustment with precise (<0.2° orientation error), responsive (1.4 Hz bandwidth), and high-resolution (0.058°) soft robotic positioning. Orientation locking provides sufficient transmission stiffness (4.07 N/mm) for instrument advancement. The system's clinical workflow and accuracy is validated with lab-based (<0.8 mm) and MRI-based testing on skull phantoms (<1.7 mm) and a cadaver subject (<2.2 mm). Custom-made wireless omni-directional tracking markers facilitated robot registration under MRI.


Assuntos
Neurocirurgia , Robótica , Procedimentos Neurocirúrgicos/métodos , Encéfalo , Imageamento por Ressonância Magnética/métodos
7.
Neuroimage ; 64: 267-76, 2013 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-22960153

RESUMO

Longitudinal changes in cortical function are known to accompany motor skills learning, and can be detected as an evolution in the activation map. These changes include attenuation in activation in the prefrontal cortex and increased activation in primary and secondary motor regions, the cerebellum and posterior parietal cortex. Despite this, comparatively little is known regarding the impact of the mode or type of training on the speed of activation map plasticity and on longitudinal variation in network architectures. To address this, we randomised twenty-one subjects to learn a complex motor tracking task delivered across six practice sessions in either "free-hand" or "gaze-contingent motor control" mode, during which frontoparietal cortical function was evaluated using functional near infrared spectroscopy. Results demonstrate that upon practice termination, gaze-assisted learners had achieved superior technical performance compared to free-hand learners. Furthermore, evolution in frontoparietal activation foci indicative of expertise was achieved at an earlier stage in practice amongst gaze-assisted learners. Both groups exhibited economical small world topology; however, networks in learners randomised to gaze-assistance were less costly and showed higher values of local efficiency suggesting improved frontoparietal communication in this group. We conclude that the benefits of gaze-assisted motor learning are evidenced by improved technical accuracy, more rapid task internalisation and greater neuronal efficiency. This form of assisted motor learning may have occupational relevance for high precision control such as in surgery or following re-learning as part of stroke rehabilitation.


Assuntos
Atenção/fisiologia , Fixação Ocular/fisiologia , Lobo Frontal/fisiologia , Aprendizagem/fisiologia , Destreza Motora/fisiologia , Rede Nervosa/fisiologia , Lobo Parietal/fisiologia , Adulto , Feminino , Humanos , Masculino , Vias Neurais/fisiologia , Volição/fisiologia
8.
IEEE Trans Robot ; 29(1): 15-31, 2013 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24741371

RESUMO

This paper presents a real-time control framework for a snake robot with hyper-kinematic redundancy under dynamic active constraints for minimally invasive surgery. A proximity query (PQ) formulation is proposed to compute the deviation of the robot motion from predefined anatomical constraints. The proposed method is generic and can be applied to any snake robot represented as a set of control vertices. The proposed PQ formulation is implemented on a graphic processing unit, allowing for fast updates over 1 kHz. We also demonstrate that the robot joint space can be characterized into lower dimensional space for smooth articulation. A novel motion parameterization scheme in polar coordinates is proposed to describe the transition of motion, thus allowing for direct manual control of the robot using standard interface devices with limited degrees of freedom. Under the proposed framework, the correct alignment between the visual and motor axes is ensured, and haptic guidance is provided to prevent excessive force applied to the tissue by the robot body. A resistance force is further incorporated to enhance smooth pursuit movement matched to the dynamic response and actuation limit of the robot. To demonstrate the practical value of the proposed platform with enhanced ergonomic control, detailed quantitative performance evaluation was conducted on a group of subjects performing simulated intraluminal and intracavity endoscopic tasks.

9.
IEEE Trans Neural Netw Learn Syst ; 34(11): 9542-9548, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35294356

RESUMO

This article investigates the positive consensus problem of a special kind of interconnected positive systems over directed graphs. They are composed of multiple fractional-order continuous-time positive linear systems. Unlike most existing works in the literature, we study this problem for the first time, in which the communication topology of agents is described by a directed graph containing a spanning tree. This is a more general and new scenario due to the interplay between the eigenvalues of the Laplacian matrix and the controller gains, which renders the positivity analysis fairly challenging. Based on the existing results in spectral graph theory, fractional-order systems (FOSs) theory, and positive systems theory, we derive several necessary and/or sufficient conditions on the positive consensus of fractional-order multiagent systems (PCFMAS). It is shown that the protocol, which is designed for a specific graph, can solve the positive consensus problem of agents over an additional set of directed graphs. Finally, a comprehensive comparison study of different approaches is carried out, which shows that the proposed approaches have advantages over the existing ones.

10.
Artigo em Inglês | MEDLINE | ID: mdl-37028287

RESUMO

In this brief, we study the decentralized H2 state-feedback control problem for networked discrete-time systems with positivity constraint. This problem (for a single positive system), raised recently in the area of positive systems theory, is known to be challenging due to its inherent nonconvexity. In contrast to most works, which only provide sufficient synthesis conditions for a single positive system, we study this problem within a primal-dual scheme, in which necessary and sufficient synthesis conditions are proposed for networked positive systems. Based on the equivalent conditions, we develop a primal-dual iterative algorithm for solution, which helps prevent from converging to a local minimum. In the simulation, two illustrative examples are employed for verification of our proposed results.

11.
Int Symp Med Robot ; 20232023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38031531

RESUMO

This paper investigates the possibility of robotically performing in situ needle manipulations to correct the needle tip position in the setting of robot-assisted, MRI-guided spinal injections, where real time MRI images cannot be effectively used to guide the needle. Open-loop control of the needle tip is derived from finite element simulation, and the proposed method is tested with ex vivo animal muscle tissues and validated by cone beam computed tomography. Preliminary results have shown promise of performing needle tip correction in situ to improve needle insertion accuracy when real-time feedback is not readily available.

12.
IEEE Robot Autom Lett ; 8(3): 1343-1350, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37637101

RESUMO

An in situ needle manipulation technique used by physicians when performing spinal injections is modeled to study its effect on needle shape and needle tip position. A mechanics-based model is proposed and solved using finite element method. A test setup is presented to mimic the needle manipulation motion. Tissue phantoms made from plastisol as well as porcine skeletal muscle samples are used to evaluate the model accuracy against medical images. The effect of different compression models as well as model parameters on model accuracy is studied, and the effect of needle-tissue interaction on the needle remote center of motion is examined. With the correct combination of compression model and model parameters, the model simulation is able to predict needle tip position within submillimeter accuracy.

13.
IEEE Trans Cybern ; PP2023 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-37440392

RESUMO

This work addresses the output reachable set-based leader-following consensus problem, focusing on a group of positive agents over directed dwell-time switching networks. Two types of non-negative disturbances, namely, 1) L1 -norm bounded disturbances and 2) L∞,1 -norm bounded disturbances are studied. Meanwhile, a class of directed dwell-time switching networks for modeling the communication protocol of positive agents is investigated. To deal with the presence of disturbances, an output-feedback control protocol is developed to achieve a robust consensus with positivity preserved based on the output reachable set. By exploiting the positive characteristics, switched linear copositive Lyapunov functions are adopted to establish output reachable set-based consensus conditions. These conditions can facilitate the control protocol design by solving a bilinear programming problem, and also generate hyperpyramidal regions to confine the output consensus error. A particle swarm optimization-based (PSO-based) algorithm is applied to compute the controller gains and optimize the volume of the hyperpyramids. The proposed methods are verified by the presented numerical case studies.

14.
Surg Endosc ; 26(7): 2003-9, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22258302

RESUMO

BACKGROUND: Eye-tracking technology has been shown to improve trainee performance in the aircraft industry, radiology, and surgery. The ability to track the point-of-regard of a supervisor and reflect this onto a subjects' laparoscopic screen to aid instruction of a simulated task is attractive, in particular when considering the multilingual make up of modern surgical teams and the development of collaborative surgical techniques. We tried to develop a bespoke interface to project a supervisors' point-of-regard onto a subjects' laparoscopic screen and to investigate whether using the supervisor's eye-gaze could be used as a tool to aid the identification of a target during a surgical-simulated task. METHODS: We developed software to project a supervisors' point-of-regard onto a subjects' screen whilst undertaking surgically related laparoscopic tasks. Twenty-eight subjects with varying levels of operative experience and proficiency in English undertook a series of surgically minded laparoscopic tasks. Subjects were instructed with verbal queues (V), a cursor reflecting supervisor's eye-gaze (E), or both (VE). Performance metrics included time to complete tasks, eye-gaze latency, and number of errors. RESULTS: Completion times and number of errors were significantly reduced when eye-gaze instruction was employed (VE, E). In addition, the time taken for the subject to correctly focus on the target (latency) was significantly reduced. CONCLUSIONS: We have successfully demonstrated the effectiveness of a novel framework to enable a supervisor eye-gaze to be projected onto a trainee's laparoscopic screen. Furthermore, we have shown that utilizing eye-tracking technology to provide visual instruction improves completion times and reduces errors in a simulated environment. Although this technology requires significant development, the potential applications are wide-ranging.


Assuntos
Simulação por Computador , Educação Médica/métodos , Movimentos Oculares , Fixação Ocular , Laparoscopia/educação , Materiais de Ensino , Análise de Variância , Desenho de Equipamento , Feminino , Humanos , Laparoscopia/instrumentação , Masculino , Reforço Verbal , Software
15.
IEEE Trans Cybern ; 52(9): 9111-9119, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33705330

RESUMO

In this article, the non-negative edge consensus problem is addressed for positive networked systems with undirected graphs using state-feedback protocols. In contrast to existing results, the major contributions of this work included: 1) significantly improved criteria of consequentiality and non-negativity, therefore leading to a linear programming approach and 2) necessary and sufficient criteria giving rise to a semidefinite programming approach. Specifically, an improved upper bound is given for the maximum eigenvalue of the Laplacian matrix and the (out-) in-degree of the degree matrix, and an improved consensuability and non-negativevity condition is obtained. The sufficient condition presented only requires the number of edges of a nodal network without the connection topology. Also, with the introduction of slack matrix variables, two equivalent conditions of consensuability and non-negativevity are obtained. In the conditions, the system matrices, controller gain, as well as Lyapunov matrices are separated, which is helpful for parameterization. Based on the results, a semidefinite programming algorithm for the controller is readily developed. Finally, a comprehensive analytical and numerical comparison of three illustrative examples is conducted to show that the proposed results are less conservative than the existing work.

16.
IEEE Trans Neural Netw Learn Syst ; 33(12): 7534-7544, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34138717

RESUMO

This article investigates the nonnegative consensus tracking problem for networked systems with a distributed static output-feedback (SOF) control protocol. The distributed SOF controller design for networked systems presents a more challenging issue compared with the distributed state-feedback controller design. The agents are described by multi-input multi-output (MIMO) positive dynamic systems which may contain uncertain parameters, and the interconnection among the followers is modeled using an undirected connected communication graph. By employing positive systems theory, a series of necessary and sufficient conditions governing the consensus of the nominal, as well as uncertain, networked positive systems, is developed. Semidefinite programming consensus design approaches are proposed for the convergence rate optimization of MIMO agents. In addition, by exploiting the positivity characteristic of the systems, a linear-programming-based design approach is also proposed for the convergence rate optimization of single-input multi-output (SIMO) agents. The proposed approaches and the corresponding theoretical results are validated by case studies.

17.
IEEE Trans Neural Netw Learn Syst ; 33(9): 4575-4583, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33646958

RESUMO

This article addresses the distributed consensus problem for identical continuous-time positive linear systems with state-feedback control. Existing works of such a problem mainly focus on the case where the networked communication topologies are of either undirected and incomplete graphs or strongly connected directed graphs. On the other hand, in this work, the communication topologies of the networked system are described by directed graphs each containing a spanning tree, which is a more general and new scenario due to the interplay between the eigenvalues of the Laplacian matrix and the controller gains. Specifically, the problem involves complex eigenvalues, the Hurwitzness of complex matrices, and positivity constraints, which make analysis difficult in the Laplacian matrix. First, a necessary and sufficient condition for the consensus analysis of directed networked systems with positivity constraints is given, by using positive systems theory and graph theory. Unlike the general Riccati design methods that involve solving an algebraic Riccati equation (ARE), a condition represented by an algebraic Riccati inequality (ARI) is obtained for the existence of a solution. Subsequently, an equivalent condition, which corresponds to the consensus design condition, is derived, and a semidefinite programming algorithm is developed. It is shown that, when a protocol is solved by the algorithm for the networked system on a specific communication graph, there exists a set of graphs such that the positive consensus problem can be solved as well.

18.
Front Robot AI ; 8: 730330, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34692777

RESUMO

Soft continuum robots have been accepted as a promising category of biomedical robots, accredited to the robots' inherent compliance that makes them safely interact with their surroundings. In its application of minimally invasive surgery, such a continuum concept shares the same view of robotization for conventional endoscopy/laparoscopy. Different from rigid-link robots with accurate analytical kinematics/dynamics, soft robots encounter modeling uncertainties due to intrinsic and extrinsic factors, which would deteriorate the model-based control performances. However, the trade-off between flexibility and controllability of soft manipulators may not be readily optimized but would be demanded for specific kinds of modeling approaches. To this end, data-driven modeling strategies making use of machine learning algorithms would be an encouraging way out for the control of soft continuum robots. In this article, we attempt to overview the current state of kinematic/dynamic model-free control schemes for continuum manipulators, particularly by learning-based means, and discuss their similarities and differences. Perspectives and trends in the development of new control methods are also investigated through the review of existing limitations and challenges.

19.
IEEE Trans Cybern ; 51(2): 501-511, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31021812

RESUMO

This paper investigates the problems of reachable set estimation and synthesis for periodic positive systems with two different exogenous disturbances. The lifting method and the pseudoperiodic Lyapunov function method are adopted for the estimation problem. The reachable set bounding conditions are proposed by employing Lyapunov-based inequalities and the S-procedure technique. Two optimization methods are used to minimize the bounding hyper-pyramids of the reachable set. In addition, the state-feedback controller design conditions that make the reachable set of closed-loop systems lie within a given hyper-pyramid are derived. Finally, numerical examples are presented to illustrate the validity of the obtained conditions.

20.
Rep U S ; 2021: 1835-1842, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-35173994

RESUMO

Lumbar injection is an image-guided procedure performed manually for diagnosis and treatment of lower back pain and leg pain. Previously, we have developed and verified an MR-Conditional robotic solution to assisting the needle insertion process. Drawing on our clinical experiences, a virtual remote center of motion (RCM) constraint is implemented to enable our robot to mimic a clinician's hand motion to adjust the needle tip position in situ. Force and image data are collected to study the needle behavior in gel phantoms during this motion, and a mechanics-based needle-tissue interaction model is proposed and evaluated to further examine the underlying physics. This work extends the commonly-adopted notion of an RCM for flexible needles, and introduces new motion parameters to describe the needle behavior. The model parameters can be tuned to match the experimental result to sub-millimeter accuracy, and this proposed needle manipulation method presents a safer alternative to laterally translating the needle during in situ needle adjustments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA