Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Genet Med ; 24(10): 2004-2013, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35951014

RESUMO

PURPOSE: Although some caregivers are using epigallocatechin gallate (EGCG) off label in hopes of improving cognition in young adults with Down syndrome (DS), nothing is known about its safety, tolerability, and efficacy in the DS pediatric population. We aimed to evaluate safety and tolerability of a dietary supplement containing EGCG and if EGCG improves cognitive and functional performance. METHODS: A total of 73 children with DS (aged 6-12 years) were randomized. Participants received 0.5% EGCG (10 mg/kg daily dose) or placebo for 6 months with 3 months follow up after treatment discontinuation. RESULTS: In total, 72 children were treated and 66 completed the study. A total of 38 participants were included in the EGCG group and 35 in the placebo group. Of 72 treated participants, 62 (86%) had 229 treatment-emergent adverse events (AEs). Of 37 participants in the EGCG group, 13 (35%) had 18 drug-related treatment-emergent AEs and 12 of 35 (34%) from the placebo group had 22 events. In the EGCG group, neither severe AEs nor increase in the incidence of AEs related to safety biomarkers were observed. Cognition and functionality were not improved compared with placebo. Secondary efficacy outcomes in girls point to a need for future work. CONCLUSION: The use of EGCG is safe and well-tolerated in children with DS, but efficacy results do not support its use in this population.


Assuntos
Catequina , Síndrome de Down , Catequina/efeitos adversos , Catequina/análogos & derivados , Criança , Cognição , Suplementos Nutricionais , Método Duplo-Cego , Síndrome de Down/tratamento farmacológico , Feminino , Humanos , Masculino
2.
Clin Imaging ; 37(1): 180-4, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23206631

RESUMO

Fracture-separation of the distal humeral epiphysis in newborn is a rare entity, usually the result of a traumatic delivery. It can mimic elbow dislocation and, due to the absence of ossification of the epiphysis at that time, cannot be diagnosed radiographically. However, ultrasound is an important diagnostic tool for this purpose because it is able to clearly visualize the cartilaginous epiphysis. In addition, it allows the differential diagnosis with posterior elbow dislocation whose therapeutic management and prognosis are different. We report the case of a preterm newborn in which a fracture-separation of the distal humeral epiphysis was diagnosed with the help of sonography. The purpose of this report is to emphasize the utility of echography as a cheap, available, and noninvasive tool for the evaluation of the nonossified epiphysis in the newborn elbow.


Assuntos
Articulação do Cotovelo/diagnóstico por imagem , Epifise Deslocada/diagnóstico por imagem , Epifise Deslocada/etiologia , Fraturas do Úmero/complicações , Fraturas do Úmero/diagnóstico por imagem , Úmero/diagnóstico por imagem , Ultrassonografia/métodos , Diagnóstico Diferencial , Humanos , Recém-Nascido
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA