Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
1.
Int J Legal Med ; 138(4): 1233-1244, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38369682

RESUMO

The use of genetic markers, specifically Short Tandem Repeats (STRs), has been a valuable tool for identifying persons of interest. However, the ability to analyze additional markers including Single Nucleotide Polymorphisms (SNPs) and Insertion/Deletion (INDELs) polymorphisms allows laboratories to explore other investigative leads. INDELs were chosen in this study because large panels can be differentiated by size, allowing them to be genotyped by capillary electrophoresis. Moreover, these markers do not produce stutter and are smaller in size than STRs, facilitating the recovery of genetic information from degraded samples. The INDEL Ancestry Informative Markers (AIMs) in this study were selected from the 1000 Genomes Project based on a fixation index (FST) greater than 0.50, high allele frequency divergence, and genetic distance. A total of 25 INDEL-AIMs were optimized and validated according to SWGDAM guidelines in a five-dye multiplex. To validate the panel, genotyping was performed on 155 unrelated individuals from four ancestral groups (Caucasian, African, Hispanic, and East Asian). Bayesian clustering and principal component analysis (PCA) were performed revealing clear separation among three groups, with some observed overlap within the Hispanic group. Additionally, the PCA results were compared against a training set of 793 samples from the 1000 Genomes Project, demonstrating consistent results. Validation studies showed the assay to be reproducible, tolerant to common inhibitors, robust with challenging casework type samples, and sensitive down to 125 pg. In conclusion, our results demonstrated the robustness and effectiveness of a 25 loci INDEL system for ancestry inference of four ancestries commonly found in the United States.


Assuntos
Eletroforese Capilar , Mutação INDEL , Análise de Componente Principal , Grupos Raciais , Humanos , Grupos Raciais/genética , Marcadores Genéticos , Genótipo , Frequência do Gene , Teorema de Bayes , Genética Populacional , Impressões Digitais de DNA/métodos , Repetições de Microssatélites
2.
Int J Legal Med ; 132(3): 727, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29532148

RESUMO

The original version of this article contained a mistake. In page 10 of the original article, the significant level (p > 0.01) is incorrect. The correct significant level is (p < 0.01). The original article has been corrected.

3.
Int J Legal Med ; 132(3): 713-725, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29464313

RESUMO

As Cannabis sativa (marijuana) is a controlled substance in many parts of the world, the ability to track biogeographical origin of cannabis could provide law enforcement with investigative leads regarding its trade and distribution. Population substructure and inbreeding may cause cannabis plants to become more genetically related. This genetic relatedness can be helpful for intelligence purposes. Analysis of autosomal, chloroplast, and mitochondrial DNA allows for not only prediction of biogeographical origin of a plant but also discrimination between individual plants. A previously validated, 13-autosomal STR multiplex was used to genotype 510 samples. Samples were analyzed from four different sites: 21 seizures at the US-Mexico border, Northeastern Brazil, hemp seeds purchased in the US, and the Araucania area of Chile. In addition, a previously reported multi-loci system was modified and optimized to genotype five chloroplast and two mitochondrial markers. For this purpose, two methods were designed: a homopolymeric STR pentaplex and a SNP triplex with one chloroplast (Cscp001) marker shared by both methods for quality control. For successful mitochondrial and chloroplast typing, a novel real-time PCR quantitation method was developed and validated to accurately estimate the quantity of the chloroplast DNA (cpDNA) using a synthetic DNA standard. Moreover, a sequenced allelic ladder was also designed for accurate genotyping of the homopolymeric STR pentaplex. For autosomal typing, 356 unique profiles were generated from the 425 samples that yielded full STR profiles and 25 identical genotypes within seizures were observed. Phylogenetic analysis and case-to-case pairwise comparisons of 21 seizures at the US-Mexico border, using the Fixation Index (F ST ) as genetic distance, revealed the genetic association of nine seizures that formed a reference population. For mitochondrial and chloroplast typing, subsampling was performed, and 134 samples were genotyped. Complete haplotypes (STRs and SNPs) were observed for 127 samples. As expected, extensive haplotype sharing was observed; five distinguishable haplotypes were detected. In the reference population, the same haplotype was observed 39 times and two unique haplotypes were also detected. Haplotype sharing was observed between the US border seizures, Brazil, and Chile, while the hemp samples generated a distinct haplotype. Phylogenetic analysis of the four populations was performed, and results revealed that both autosomal and lineage markers could discern population substructure.


Assuntos
Cannabis/genética , Núcleo Celular/genética , Cloroplastos/genética , Impressões Digitais de DNA , DNA Mitocondrial , Bases de Dados de Ácidos Nucleicos , Tráfico de Drogas , Genótipo , Haplótipos , Humanos , Repetições de Microssatélites , Filogenia , Polimorfismo de Nucleotídeo Único
4.
Int J Legal Med ; 130(2): 341-52, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26645290

RESUMO

Ancestry informative markers (AIMs) can be used to detect and adjust for population stratification and predict the ancestry of the source of an evidence sample. Autosomal single nucleotide polymorphisms (SNPs) are the best candidates for AIMs. It is essential to identify the most informative AIM SNPs across relevant populations. Several informativeness measures for ancestry estimation have been used for AIMs selection: absolute allele frequency differences (δ), F statistics (F ST), and informativeness for assignment measure (In). However, their efficacy has not been compared objectively, particularly for determining affiliations of major US populations. In this study, these three measures were directly compared for AIMs selection among four major US populations, i.e., African American, Caucasian, East Asian, and Hispanic American. The results showed that the F ST panel performed slightly better for population resolution based on principal component analysis (PCA) clustering than did the δ panel and both performed better than the In panel. Therefore, the 23 AIMs selected by the F ST measure were used to characterize the four major American populations. Genotype data of nine sample populations were used to evaluate the efficiency of the 23-AIMs panel. The results indicated that individuals could be correctly assigned to the major population categories. Our AIMs panel could contribute to the candidate pool of AIMs for potential forensic identification purposes.


Assuntos
Marcadores Genéticos , Genética Populacional , Polimorfismo de Nucleotídeo Único , Grupos Raciais/genética , Frequência do Gene , Genótipo , Projeto HapMap , Humanos , Análise de Componente Principal , Estados Unidos
5.
BMC Genomics ; 16 Suppl 1: S4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25924014

RESUMO

BACKGROUND: Massively parallel sequencing (MPS) technologies have the capacity to sequence targeted regions or whole genomes of multiple nucleic acid samples with high coverage by sequencing millions of DNA fragments simultaneously. Compared with Sanger sequencing, MPS also can reduce labor and cost on a per nucleotide basis and indeed on a per sample basis. In this study, whole genomes of human mitochondria (mtGenome) were sequenced on the Personal Genome Machine (PGMTM) (Life Technologies, San Francisco, CA), the out data were assessed, and the results were compared with data previously generated on the MiSeqTM (Illumina, San Diego, CA). The objectives of this paper were to determine the feasibility, accuracy, and reliability of sequence data obtained from the PGM. RESULTS: 24 samples were multiplexed (in groups of six) and sequenced on the at least 10 megabase throughput 314 chip. The depth of coverage pattern was similar among all 24 samples; however the coverage across the genome varied. For strand bias, the average ratio of coverage between the forward and reverse strands at each nucleotide position indicated that two-thirds of the positions of the genome had ratios that were greater than 0.5. A few sites had more extreme strand bias. Another observation was that 156 positions had a false deletion rate greater than 0.15 in one or more individuals. There were 31-98 (SNP) mtGenome variants observed per sample for the 24 samples analyzed. The total 1237 (SNP) variants were concordant between the results from the PGM and MiSeq. The quality scores for haplogroup assignment for all 24 samples ranged between 88.8%-100%. CONCLUSIONS: In this study, mtDNA sequence data generated from the PGM were analyzed and the output evaluated. Depth of coverage variation and strand bias were identified but generally were infrequent and did not impact reliability of variant calls. Multiplexing of samples was demonstrated which can improve throughput and reduce cost per sample analyzed. Overall, the results of this study, based on orthogonal concordance testing and phylogenetic scrutiny, supported that whole mtGenome sequence data with high accuracy can be obtained using the PGM platform.


Assuntos
Genoma Humano/genética , Genoma Mitocondrial/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Pareamento de Bases , Viés , DNA Mitocondrial/genética , Bases de Dados Genéticas , Haplótipos/genética , Humanos , Deleção de Sequência
6.
J Forensic Sci ; 69(3): 814-824, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38291825

RESUMO

DNA analysis of forensic case samples relies on short tandem repeats (STRs), a key component of the combined DNA index system (CODIS) used to identify individuals. However, limitations arise when dealing with challenging samples, prompting the exploration of alternative markers such as single nucleotide polymorphisms (SNPs) and insertion/deletion (INDELs) polymorphisms. Unlike SNPs, INDELs can be differentiated easily by size, making them compatible with electrophoresis methods. It is possible to design small INDEL amplicons (<200 bp) to enhance recovery from degraded samples. To this end, a set of INDEL Human Identification Markers (HID) was curated from the 1000 Genomes Project, employing criteria including a fixation index (FST) ≤ 0.06, minor allele frequency (MAF) >0.2, and high allele frequency divergence. A panel of 33 INDEL-HIDs was optimized and validated following the Scientific Working Group on DNA Analysis Methods (SWGDAM) guidelines, utilizing a five-dye multiplex electrophoresis system. A small sample set (n = 79 unrelated individuals) was genotyped to assess the assay's performance. The validation studies exhibited reproducibility, inhibition tolerance, ability to detect a two-person mixture from a 4:1 to 1:6 ratio, robustness with challenging samples, and sensitivity down to 125 pg of DNA. In summary, the 33-loci INDEL-HID panel exhibited robust recovery with low-template and degraded samples and proved effective for individualization within a small sample set.


Assuntos
Impressões Digitais de DNA , Frequência do Gene , Mutação INDEL , Humanos , Impressões Digitais de DNA/métodos , Reprodutibilidade dos Testes , Marcadores Genéticos , Genótipo , Corantes Fluorescentes , Reação em Cadeia da Polimerase , Polimorfismo Genético , Eletroforese Capilar , Repetições de Microssatélites
7.
Int J Legal Med ; 127(2): 299-308, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22895803

RESUMO

The detection of semen can assist in reconstructing the events of a sexual assault and impact the outcome of legal dispositions. Many methods currently are used for detecting the presence of semen, but they all have limitations with regards to specificity, sample degradation/consumption, stability of biomolecule assayed, and/or incompatibility with downstream individual identification assays. DNA is routinely collected at sexual assault crime scenes and is widely used for individual identification. The DNA also carries methylation patterns that are tissue specific. To date, however, assays designed to exploit methylation patterns suffer from complex chemistries and unwieldy analyses. DSI-Semen™ kit uses a novel approach involving CpG methylation-sensitive restriction endonuclease digestion coupled to a multiplexed polymerase chain reaction (PCR) to generate an amplicon profile that makes it possible to determine whether the tissue source of a DNA sample was semen or non-semen. The assay returned an appropriate positive result for semen with neat semen, semen stains, and semen/non-semen tissue mixtures. The assay is robust and reliable, with a positive result for semen given as little as 31 pg of template DNA input. Low levels of semen were detected in mixtures of semen and other body fluids. UV-exposed samples and those in the presence of limited concentrations of known PCR inhibitors were typeable. The DSI-Semen™ kit provides a reliable tool for the determination of DNA being derived from semen.


Assuntos
Metilação de DNA , Enzimas de Restrição do DNA/metabolismo , Genética Forense/instrumentação , Sêmen/metabolismo , Animais , Análise Química do Sangue , DNA/efeitos dos fármacos , Degradação Necrótica do DNA , Impressões Digitais de DNA , Fragmentação do DNA , Primers do DNA , Eletroforese , Humanos , Funções Verossimilhança , Limite de Detecção , Masculino , Repetições de Microssatélites , Mucosa Bucal/metabolismo , Reação em Cadeia da Polimerase Multiplex , Reação em Cadeia da Polimerase , Reprodutibilidade dos Testes , Saliva/metabolismo , Software , Raios Ultravioleta
8.
Hum Hered ; 74(1): 27-35, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23095285

RESUMO

OBJECTIVES: Retrotransposable elements (REs), consisting of long interspersed nuclear elements (LINEs) and short interspersed nuclear elements (SINEs), are a group of markers that can be useful for human identity testing. Until now, however, due to the inherent size difference (up to 6 kb in some instances) associated with insertion and null alleles (or INNULs), the use of REs for facilitated population studies has not been sought or practical. The size of the insertion elements (from a few hundred to several thousand bp) has proven to limit their utility as a marker because of the inefficient amplicon yield with PCR. A novel primer design now facilitates INNUL marker testing. A preliminary panel of single-locus markers was developed to evaluate the potential of typing these insertion elements. Nine INNULs (5 Alu and 4 LINEs) were typed in three major North American populations and analyzed for population genetic features. In addition, the variation of each marker among the sample populations provides insight of its potential use as individual identification or ancestral marker. METHODS: INNUL markers were developed into fluorescently labeled single-loci PCR. Nine markers were developed with amplicons that were less than 180 bp in length, and, depending on the locus amplicons of the INNULs, alleles varied in size from 50 to 1 bp. This allele size is noteworthy because the insertion alleles of the 9 loci range in size from 297 to 6,195 bp. The allele distribution of the INNULs was assessed and analyzed in three major North American populations. RESULTS: Upon observation of the distribution of the alleles in three major North American populations, the markers generally met Hardy-Weinberg expectations, and there was little evidence of detectable levels of linkage disequilibrium. Due to varying distributions of the alleles in the major population groups tested, some of the markers might be better suited for use as an individual identification marker, while others are better suited for bio-ancestral studies. CONCLUSIONS: Using the primer design strategy described in our work, SINEs and (for the first time, to our knowledge) LINEs can be utilized as markers for studying population genetic variation that is more amenable to the limitations of the PCR technique. This study lays the foundation for future work of developing a multiplex panel of INNUL markers that can be used as a single-tube assay for human identity testing utilizing small amplicons (<180 bp), which could be useful for ancient or degraded forensic DNA samples.


Assuntos
Variação Genética , Genética Populacional/métodos , Retroelementos , Software , Alelos , Primers do DNA/genética , Humanos , Reação em Cadeia da Polimerase , Polimorfismo Genético , Grupos Raciais/genética
9.
J Forensic Sci ; 68(2): 596-607, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36725687

RESUMO

Formalin-fixed tissues provide the medical and forensic communities with alternative and often last resort sources of DNA for identification or diagnostic purposes. The DNA in these samples can be highly degraded and chemically damaged, making downstream genotyping using short tandem repeats (STRs) challenging. Therefore, the use of alternative genetic markers, methods that pre-amplify the low amount of good quality DNA present, or methods that repair the damaged DNA template may provide more probative genetic information. This study investigated whether whole genome amplification (WGA) and DNA repair could improve STR typing of formaldehyde-damaged (FD) tissues from embalmed cadavers. Additionally, comparative genotyping success using bi-allelic markers, including INDELs and SNPs, was explored. Calculated random match probabilities (RMPs) using traditional STRs, INDEL markers, and two next generation sequencing (NGS) panels were compared across all samples. Overall, results showed that neither WGA nor DNA repair substantially improved STR success rates from formalin-fixed tissue samples. However, when DNA from FD samples was genotyped using INDEL and SNP-based panels, the RMP of each sample was markedly lower than the RMPs calculated from partial STR profiles. Therefore, the results of this study suggest that rather than attempting to improve the quantity and quality of severely damaged and degraded DNA prior to STR typing, a more productive approach may be to target smaller amplicons to provide more discriminatory DNA identifications. Furthermore, an NGS panel with less loci may yield better results when examining FD samples, due to more optimized chemistries that result in greater allelic balance and amplicon coverage.


Assuntos
Impressões Digitais de DNA , Antropologia Forense , Humanos , Impressões Digitais de DNA/métodos , Formaldeído , Genótipo , DNA/análise , Repetições de Microssatélites , Polimorfismo de Nucleotídeo Único
10.
Forensic Sci Int Genet ; 64: 102851, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36907074

RESUMO

For human identification purposes, forensic genetics has primarily relied upon a core set of autosomal (and to a lesser extent Y chromosome) short tandem repeat (STR) markers that are enriched by amplification using the polymerase chain reaction (PCR) that are subsequently separated and detected using capillary electrophoresis (CE). While STR typing conducted in this manner is well-developed and robust, advances in molecular biology that have occurred over the last 15 years, in particular massively parallel sequencing (MPS) [1-7], offer certain advantages as compared to CE-based typing. First and foremost is the high throughput capacity of MPS. Current bench top high throughput sequencers enable larger batteries of markers to be multiplexed and multiple samples to be sequenced simultaneously (e.g., millions to billions of nucleotides can be sequenced in one run). Second, compared to the length-based CE approach, sequencing STRs increases discrimination power, enhances sensitivity of detection, reduces noise due to instrumentation, and improves mixture interpretation [4,8-23]. Third, since detection of STRs is based on sequence and not fluorescence, amplicons can be designed that are shorter in length and of similar lengths among loci, where possible, which can improve amplification efficiency and analysis of degraded samples. Lastly, MPS offers a single format approach that can be applied to analysis of a wide variety of genetic markers of forensic interest (e.g., STRs, mitochondrial DNA, single nucleotide polymorphisms, insertion/deletions). These features make MPS a desirable technology for casework [14,15,24,25-48]. The developmental validation of the ForenSeq MainstAY library preparation kit with the MiSeq FGx Sequencing System and ForenSeq Universal Software is reported here to assist with validation of this MPS system for casework [49]. The results show that the system is sensitive, accurate and precise, specific, and performs well with mixtures and mock case-type samples.


Assuntos
Impressões Digitais de DNA , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Impressões Digitais de DNA/métodos , Reação em Cadeia da Polimerase , Mutação INDEL , Repetições de Microssatélites , Polimorfismo de Nucleotídeo Único , Análise de Sequência de DNA
11.
Int J Legal Med ; 126(4): 533-40, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22249274

RESUMO

Marker sets that are based on small insertion/deletion (INDEL) alleles can serve as useful supplementary or stand-alone assays for human identification. A validation study has been performed on a human identification assay based on a panel of 30 INDELs and amelogenin using the Investigator DIPplex® kit (Qiagen). The assay was able to type DNA from a number of forensically relevant sample types and obtain full profiles with 62 pg of template DNA and partial profiles with as little as 16 pg of template DNA. The assay is reproducible, precise, and non-overlapping alleles from minor contributors were detectable in mixture analysis ranging from 6:1 to 19:1 mixtures. Population studies were performed on the 30 indels, and there were no significant departures from Hardy-Weinberg equilibrium or significant linkage disequilibrium between the markers (after correction for sampling). In all populations, the random match probability was 1.43 × 10(-11) or less, and the power of exclusion was greater than .999999999. We also discovered several microvariant alleles in our population samples. The data support that the Investigator DIPplex® kit provides a powerful supplement or stand-alone capability for human identity testing.


Assuntos
Impressões Digitais de DNA/instrumentação , Mutação INDEL , Amelogenina/genética , DNA/análise , Impressões Digitais de DNA/métodos , Eletroforese Capilar , Feminino , Frequência do Gene , Genética Populacional , Humanos , Desequilíbrio de Ligação , Masculino , Grupos Raciais/genética , Reprodutibilidade dos Testes
12.
Forensic Sci Int Genet ; 59: 102721, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35576791

RESUMO

The ForenSeq® mtDNA Control Region Kit, MiSeq FGx®, and Universal Analysis Software (UAS) were assessed to better define the performance and limitations of the system with forensically relevant samples to provide data for its transition into practice. A total of six MiSeq FGx sequencing runs of ForenSeq mtDNA Control Region kit, three runs of additional orthogonal sequencing chemistries, and Sanger sequencing results for 14 samples were used to test for concordance. Sensitivity, reproducibility, mixture detection studies, as well as studies to measure the performance of amplification and sequencing controls were performed. The use and reliability of the UAS for data analysis was also examined. With a variety of sample types and controls representing many mitochondrial haplotypes, the recently developed mtDNA Control Region Kit, with the MiSeq FGx and UAS, was found to be fit for purpose as reliable, reproducible, and robust. Sensitivity down to 1 pg of input genomic DNA was demonstrated, which allows the system to offer low limits of detection for better interrogation of potential heteroplasmy in samples. Concerns for implementing next generation sequencing (NGS) for mtDNA in laboratories were addressed in this research, including initial template quantification and confirmation of haplotypes generated by UAS software regarding length-based polymorphisms. To improve performance with forensic samples, laboratories could implement mitochondrial-specific qPCR assays for quantification and perform the optional manual normalization protocol. Additional optimization on sample multiplexing can provide methods that either increase sensitivity or cost efficiency of the assay.


Assuntos
Impressões Digitais de DNA , DNA Mitocondrial , Impressões Digitais de DNA/métodos , DNA Mitocondrial/genética , Haplótipos , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Reprodutibilidade dos Testes , Análise de Sequência de DNA
13.
Hum Immunol ; 83(1): 61-69, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34728094

RESUMO

Chimerism testing provides informative clinical data regarding the status of a biological sample mixture. For years, this testing was achieved by measuring the peaks of informative short tandem repeat (STR) loci using capillary electrophoresis (CE). With the advent of next generation sequencing (NGS) technology, the quantification of the percentage of donor/recipient mixtures is more easily done using sequence reads in large batches of samples run on a single flow cell. In this study, we present data on using a FORENSIC NGS chimerism platform to accurately measure the percentage of donor/recipient mixtures. We were able to detect chimerism to a limit threshold of 1% using both STR and single nucleotide polymorphism (SNP) informative loci. Importantly, a significant correlation was observed between NGS and CE chimerism methods when compared at donor detection ranges from 1% to 10%. Furthermore, 100% accuracy was achieved through proficiency testing over six surveys. Its usefulness was expanded beyond this to help identify suitable donors for solid organ transplant patients using ancestry SNP profiles. In summary, the NGS method provides a sensitive and reliable alternative to traditional CE for chimerism testing of clinical samples.


Assuntos
Quimerismo , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Repetições de Microssatélites/genética , Polimorfismo de Nucleotídeo Único
14.
J Forensic Sci ; 66(5): 1929-1936, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34057738

RESUMO

Rootless hair shafts are often considered unsuitable for STR genotyping due to the known high failure rate. The same samples can be reliably processed with mitochondrial sequencing. However, the minimal discriminatory power of widely implemented control region mitochondrial sequencing techniques limits its utility in some forensic casework. In this research, multiple variables were tested to provide information on rootless hair shaft sample genotyping success. Results showed external decontamination procedures decreased drop-in alleles but also greatly reduced profile recovery. The novel InnoXtract™ chemistry was comparable to automated EZ1 DNA Investigator extraction. With thoroughly decontaminated hairs, InnoTyper® 21 amplification generated random match probabilities higher than STR chemistry in 71.875% of samples and 18.75% of samples benefitted from the use of InnoTyper® 21 amplification compared with estimated mtDNA profile rarity. Compared with the capillary electrophoresis-based amplification chemistries tested, the ForenSeq™ DNA Signature Prep chemistry paired with massively parallel sequencing was the most discriminatory amplification strategy tested.


Assuntos
Impressões Digitais de DNA/métodos , DNA/genética , Genética Forense/métodos , Cabelo/química , Genótipo , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Repetições de Microssatélites , Reação em Cadeia da Polimerase , Polimorfismo de Nucleotídeo Único , Análise de Sequência de DNA
15.
Sci Justice ; 60(3): 253-262, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32381242

RESUMO

Papaver somniferum, commonly known as opium poppy, is the source of natural opiates, which are used as analgesics or as precursors in the creation of semi-synthetic opioids such as heroin. An increase in opioid addiction in the United States has resulted in high rates of illicit opioid use and overdoses. It has recently been shown that P. somniferum DNA suitable for genetic analysis can be recovered from heroin samples. The development of a comprehensive genetic individualization tool for opium poppy could serve to link cases and strengthen programs such as the Drug Enforcement Administration's (DEA) Heroin Signature Program, which seeks to combat rising opioid use. The purpose of this study was to develop a quantitative real-time PCR (qPCR) method for the quantification of opium poppy DNA, compare three commercial DNA extraction kits for their ability to isolate DNA from poppy seeds, and evaluate nineteen opium poppy short tandem repeat (STR) markers for their use in a forensic identification panel. Such a panel could be used for individualizing samples and determining the geographic origin in heroin or poppy seed tea cases. The qPCR method was proven to be reproducible and reliable, specific for P. somniferum, and sensitive enough for forensic case-type samples. Of the three kits tested, the nexttec™ one-step DNA Isolation Kit for Plants was the optimal method and facilitated rapid extraction of DNA from poppy seeds. The majority of evaluated STR primer sets were unreliable or had low discriminatory power, limiting their use for individualization of poppy samples. A six-locus STR multiplex was developed and evaluated according to Scientific Working Group on DNA Analysis Methods (SWGDAM) and International Society of Forensic Genetics (ISFG) guidelines, including the use of a sequenced allelic ladder. The multiplex was found to have low discriminatory power, with greater than two-thirds of samples analyzed having just two different genotypes. The multiplex was determined to be unsuitable for individualization; however, a genotype map was developed as a proof of concept that these markers may be useful for determining the biogeographical origin of samples. Searching the poppy genome for new STR markers and developing new primer sets may be necessary for the creation of a powerful genetic tool for the individualization of P. somniferum.


Assuntos
Repetições de Microssatélites , Papaver , Alelos , Analgésicos Opioides , Biomarcadores , Heroína , Papaver/genética
16.
Leg Med (Tokyo) ; 43: 101658, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31954956

RESUMO

Crimes committed with assault rifles are becoming increasingly prevalent in the United States. In the absence of other evidence, DNA analysis can often provide informative leads. Unfortunately, any DNA transferred to rifle components left behind at a crime scene is likely to be low in quantity and/or quality. Furthermore, collected evidence is unlikely to be processed immediately and may require storage. Long-term storage can subject DNA to damage and degradation, which ultimately affects DNA profile interpretation and may prevent the identification of potential suspects. This study assessed the ability of a new swab storage device, the SwabSaver®, to preserve "touch" DNA from AR-15 magazine rifles using three different collection devices. Three volunteers loaded bullet cartridges into plastic polymer and aluminum AR-15 magazines. DNA was collected with traditional cotton swabs, layered cotton paper swabs, or nylon-flocked swabs. Collection devices were then stored at room-temperature for up to two months in either the SwabSaver® device or an empty centrifuge tube. The results suggest that substrate and swab type had less of an effect on profile completeness than storage type. Furthermore, SwabSaver® storage yielded DNA quantities comparable to "touch" DNA extracted after 24 h.


Assuntos
Crime , Impressões Digitais de DNA/métodos , Manejo de Espécimes/métodos , Temperatura , Fatores de Tempo , Humanos
17.
Sci Justice ; 59(5): 580-584, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31472804

RESUMO

When analyzing DNA from exploded pipe bombs, quantities are often in trace amounts, making DNA typing extremely difficult. Amplifying minute amounts of DNA can cause stochastic effects resulting in partial or uninterpretable profiles. Therefore, the initial DNA collection from "touch" evidence must be optimized to maximize the amount of DNA available for analysis. This proof-of-concept study evaluated two different swab types with two direct amplification strategies to identify the most effective method for recovering DNA from common pipe bomb substrates. PVC and steel pipes, electrical tape, and copper wire spiked with epithelial cells were swabbed with cotton or microFLOQ® Direct Swabs and amplified directly or via a pre-treatment prior to STR amplification. Not only was the microFLOQ® Direct Swab protocol the quickest method with the least risk of contamination, but in combination with direct amplification, the microFLOQ® Direct Swabs also generated the most complete STR profiles.


Assuntos
Impressões Digitais de DNA/métodos , DNA/isolamento & purificação , Amplificação de Genes , Repetições de Microssatélites , Bombas (Dispositivos Explosivos) , DNA/análise , Células Epiteliais/química , Humanos , Masculino , Cloreto de Polivinila , Aço
18.
Leg Med (Tokyo) ; 38: 45-50, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30959396

RESUMO

The identification of body fluids in evidentiary stains may provide investigators with probative information during an investigation. In this study, quantitative reverse transcription polymerase chain reaction (RT-qPCR) assays were performed to detect the presence of mRNA and miRNA in fresh and environmentally challenged samples. Blood, semen, and reference markers were chosen for both mRNA/miRNA testing. Samples of blood and semen were exposed to heat, humidity, and sunlight, and controlled conditions (room temperature, low humidity, and darkness) for 6 months. All mRNA targets were observed through six months under controlled conditions, but were undetected after 30 days in experimental conditions. However, miRNA targets persisted under all test conditions for the duration of the study. Additionally, cotton stained with blood or semen was laundered using a liquid detergent in various washing and drying conditions. An unstained cutting was evaluated for potential transfer. Both miRNA targets were observed in all stained samples regardless of the wash protocol used. Of the mRNA markers, HBB was detected in all bloodstained samples and PRM1 persisted in all but one semen stained sample. The unstained samples showed transfer of at least one body fluid specific miRNA marker in all samples and at least one body fluid specific mRNA in approximately half of the samples. These results support that RNA markers can be used for body fluid identification in challenging samples, and that miRNA markers may be more persistent than mRNA for blood and semen stains. However, some caution is warranted with laundered items due to possible transfer.


Assuntos
Líquidos Corporais/química , Meio Ambiente , Medicina Legal/métodos , Lavanderia , MicroRNAs/análise , RNA Mensageiro/análise , Sêmen/química , Biomarcadores/análise , Biomarcadores/sangue , Ambiente Controlado , Temperatura Alta , Humanos , Umidade , Masculino , MicroRNAs/sangue , RNA Mensageiro/sangue , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Luz Solar , Fatores de Tempo
19.
Genetics ; 174(3): 1173-87, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16980394

RESUMO

Oxygen deprivation has a role in the pathology of many human diseases. Thus it is of interest in understanding the genetic and cellular responses to hypoxia or anoxia in oxygen-deprivation-tolerant organisms such as Caenorhabditis elegans. In C. elegans the DAF-2/DAF-16 pathway, an IGF-1/insulin-like signaling pathway, is involved with dauer formation, longevity, and stress resistance. In this report we compared the response of wild-type and daf-2(e1370) animals to anoxia. Unlike wild-type animals, the daf-2(e1370) animals have an enhanced anoxia-survival phenotype in that they survive long-term anoxia and high-temperature anoxia, do not accumulate significant tissue damage in either of these conditions, and are motile after 24 hr of anoxia. RNA interference was used to screen DAF-16-regulated genes that suppress the daf-2(e1370)-enhanced anoxia-survival phenotype. We identified gpd-2 and gpd-3, two nearly identical genes in an operon that encode the glycolytic enzyme glyceraldehyde-3-phosphate dehydrogenase. We found that not only is the daf-2(e1370)-enhanced anoxia phenotype dependent upon gpd-2 and gpd-3, but also the motility of animals exposed to brief periods of anoxia is prematurely arrested in gpd-2/3(RNAi) and daf-2(e1370);gpd-2/3(RNAi) animals. These data suggest that gpd-2 and gpd-3 may serve a protective role in tissue exposed to oxygen deprivation.


Assuntos
Caenorhabditis elegans/fisiologia , Gliceraldeído-3-Fosfato Desidrogenases/metabolismo , Hipóxia , Sobrevida , Animais , Caenorhabditis elegans/genética , Caenorhabditis elegans/crescimento & desenvolvimento , Proteínas de Caenorhabditis elegans/genética , Proteínas de Caenorhabditis elegans/fisiologia , Bases de Dados Genéticas , Fatores de Transcrição Forkhead , Gliceraldeído-3-Fosfato Desidrogenases/genética , Óperon , Interferência de RNA , Receptor de Insulina/genética , Receptor de Insulina/fisiologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Taxa de Sobrevida , Temperatura , Fatores de Transcrição/genética , Fatores de Transcrição/fisiologia
20.
Forensic Sci Int Genet ; 31: 180-188, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29055861

RESUMO

Traditionally, forensic DNA analysis has required highly skilled forensic geneticists in a dedicated laboratory to generate short tandem repeat (STR) profiles. STR profiles are routinely used either to associate or exclude potential donors of forensic biological evidence. The typing of forensic reference samples has become more demanding, especially with the requirement in some jurisdictions to DNA profile arrestees. The Rapid DNA (RDNA) platform, the RapidHIT® ID (IntegenX®, Pleasanton, CA), is a fully automated system capable of processing reference samples in approximately 90min with minimal human intervention. Thus, the RapidHIT ID instrument can be deployed to non-laboratory environments (e.g., booking stations) and run by trained atypical personnel such as law enforcement. In order to implement the RapidHIT ID platform, validation studies are needed to define the performance and limitations of the system. Internal validation studies were undertaken with four early-production RapidHIT ID units. Reliable and concordant STR profiles were obtained from reference buccal swabs. Throughout the study, no contamination was observed. The overall first-pass success rate with an "expert-like system" was 72%, which is comparable to another current RDNA platform commercially available. The system's second-pass success rate (involving manual interpretation on first-pass inconclusive results) increased to 90%. Inhibitors (i.e., coffee, smoking tobacco, and chewing tobacco) did not appear to affect typing by the instrument system; however, substrate (i.e., swab type) did impact typing success. Additionally, one desirable feature not available with other Rapid systems is that in the event of a system failed run, a swab can be recovered and subsequently re-analyzed in a new sample cartridge. Therefore, rarely should additional sampling or swab consumption be necessary. The RapidHIT ID system is a robust and reliable tool capable of generating complete STR profiles within the forensic DNA typing laboratory or with proper training in decentralized environments by non-laboratory personnel.


Assuntos
Impressões Digitais de DNA/instrumentação , DNA/isolamento & purificação , Repetições de Microssatélites , DNA/genética , Eletroforese , Genótipo , Humanos , Mucosa Bucal/química , Reação em Cadeia da Polimerase , Manejo de Espécimes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA