Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 122
Filtrar
1.
J Clin Periodontol ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38987924

RESUMO

AIM: Depression is prevalent among older adults. Although the number of missing teeth is considered to be associated with depression, the relationship between masticatory function, which is usually indicated by functional tooth units (FTUs), and depression in older adults remains unclear. MATERIALS AND METHODS: This study used data from the National Health and Nutrition Examination Survey (NHANES) 2009-2018. The number of FTUs was defined as pairs of opposing natural and artificial teeth. Depression was accessed using the Patient Health Questionnaire (PHQ-9), and participants who scored ≥10 on PHQ-9 were diagnosed with depression. Logistic regression analyses, propensity score matching (PSM) analyses and subgroup analyses were conducted to assess the association between FTU and depression. RESULTS: The analysis included 5764 individuals over 60 years. An association between FTU and the risk of depression among older adults was detected (odds ratio [OR] = 0.951, 95% confidence interval [CI] 0.915-0.989), suggesting protective roles of more FTUs. Significant increase in the risk of depression in 0 ≤ FTUs ≤ 3 was observed compared with 10 ≤ FTUs ≤ 12 (OR = 1.819, 95% CI 1.157-2.858). However, no significant increase in the risk of depression in 4 ≤ FTUs ≤ 9 was found. After PSM, significant increase in the risk of depression in 0 ≤ FTUs ≤ 3 was still detected compared with 4 ≤ FTUs ≤ 12 (OR = 1.484, 95% CI 1.030-2.136). Subgroup analyses demonstrated consistent results in all subgroups, except for individuals aged 76-80 and drinking regularly. CONCLUSIONS: The findings suggested the association between impaired masticatory function and the risk of depression among older adults. Longitudinal studies are needed to elucidate the role of masticatory function impairment in the development of depression further.

2.
J Clin Periodontol ; 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38807437

RESUMO

AIM: Impairment of masticatory function in elderly patients with terminal dentition due to stage IV periodontitis (TDS4P) may lead to lower nutritional intake. The study aimed to report the dietary intake and nutrition status of elderly patients with TDS4P and compare them with those of the elderly Chinese population and the Chinese Dietary Reference Intakes (DRIs). MATERIALS AND METHODS: Fifty-one consecutive subjects (≥55 years old) with TDS4P were enrolled. Average dietary intake was evaluated based on a 3-day 24-h dietary recall (24HR) and food frequency questionnaire (FFQ). The daily intake of fresh vegetables and fruits, dietary energy as well as macro and micronutrients were calculated and compared with matched national data and the Chinese DRIs. Nutritional status was assessed by Short-Form Mini-Nutritional assessment. RESULTS: Of the subjects, 19.6% (95% CI: 7.2%-28.1%) were at risk of malnutrition. The mean daily energy intake was 1517.4 kcal (95% CI: 1400.5-1634.3) for males and 1110.7 kcal (95% CI: 1001.5-1219.9) for females, which were very low compared with both the national data and the DRIs. Females derived a higher percentage of energy from fat. The mean daily intake of vegetables was 151.4 g (95% CI: 128.1-174.8) by FFQ and 130.9 g (95% CI: 104.6-157.3) by 24HR. Both results were significantly lower than the national reports (95% CI: 310.3-340.1) and the DRIs (300-450 g). Insufficient micronutrient intake, especially vitamins A, C and E, was also found. CONCLUSIONS: Elderly subjects with TDS4P had a lower daily energy intake, vegetable and fruit consumption and essential macro and micronutrient intake. More studies are needed to clarify the impact of periodontitis and tooth loss/replacement on nutrition and healthy ageing.

3.
J Clin Periodontol ; 51(1): 24-32, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37872750

RESUMO

AIM: To compare the implant accuracy, safety and morbidity between robot-assisted and freehand dental implant placement. MATERIALS AND METHODS: Subjects requiring single-site dental implant placement were recruited. Patients were randomly allocated to freehand implant placement and robot-assisted implant placement. Differences in positional accuracy of the implant, surgical morbidity and complications were assessed. The significance of intergroup differences was tested with an intention-to-treat analysis and a per-protocol (PP) analysis (excluding one patient due to calibration error). RESULTS: Twenty patients (with a median age of 37, 13 female) were included. One subject assigned to the robotic arm was excluded from the PP analysis because of a large calibration error due to the dislodgement of the index. For robot-assisted and freehand implant placement, with the PP analysis, the median (25th-75th percentile) platform global deviation, apex global deviation and angular deviation were 1.23 (0.9-1.4) mm/1.9 (1.2-2.3) mm (p = .03, the Mann-Whitney U-test), 1.40 (1.1-1.6) mm/2.1 (1.7-3.9) mm (p < .01) and 3.0 (0.9-6.0)°/6.7 (2.2-13.9)° (p = .08), respectively. Both methods showed limited damage to the alveolar ridge and had similar peri- and post-operative morbidity and safety. CONCLUSIONS: Robot-assisted implant placement enabled greater positional accuracy of the implant compared to freehand placement in this pilot trial. The robotic system should be further developed to simplify surgical procedures and improve accuracy and be validated in properly sized trials assessing the full spectrum of relevant outcomes.


Assuntos
Implantes Dentários , Robótica , Cirurgia Assistida por Computador , Humanos , Feminino , Projetos Piloto , Tecnologia Háptica , Implantação Dentária Endóssea/métodos , Tomografia Computadorizada de Feixe Cônico , Desenho Assistido por Computador
4.
J Clin Periodontol ; 51(6): 691-701, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38348766

RESUMO

AIM: Emerging evidence points to a two-way relationship between periodontitis and dietary choices and, thus, nutrition. This study aimed to assess the potential cause-effect relationship between the periodontitis stage, loss of functional tooth units (FTUs), masticatory function, and intake of different food groups using path analysis. MATERIALS AND METHODS: A single calibrated examiner determined the periodontitis stage of a consecutive sample of 241 Chinese subjects reporting for tooth replacement. Their masticatory function was quantified by the mixing ability of a two-colour chewing gum. Validated food frequency questionnaires were used to calculate the intake of 33 food group items by an experienced calibrated rater. After verification of assumptions, visual structural equation modeling was performed with Amos 23. The consistency of results and the potential modifying effect of age were assessed in 9043 subjects from the NHANES database. RESULTS: Highly significant models were constructed using periodontitis stage and age as exogenous factors. Periodontitis stage diagnosis significantly affected the number of posterior FTUs and oral health-related quality of life (OHRQoL, path coefficient [PC] = -0.55 and -0.20, p < .05, respectively). In the model, FTUs also had an independent effect on OHRQoL (PC = 0.23, p < .05). FTUs determined the level of masticatory function (PC = -0.38, p < .05), which in turn affected vegetable intake but not fruit or meat intake (PC = -0.18, p < .0.5, PC = 0.06, NS and PC = 0.11, NS, respectively). The effect of age was significant for vegetable and meat intake and was also correlated with periodontitis stage diagnosis. Analysis of the NHANES database confirmed the negative impact of periodontitis on the number of occluding pairs and vegetable consumption for the 18-44, 45-60 and >60 age groups. CONCLUSIONS: Periodontitis showed a potential cause-effect pathway affecting vegetable intake across cultures and age groups. The size of the effect is potentially of clinical and public health significance. Additional studies, including intervention trials, are required to test this potential mechanism linking oral health to nutrition.


Assuntos
Mastigação , Periodontite , Verduras , Humanos , Mastigação/fisiologia , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Qualidade de Vida , Perda de Dente , Dieta , Idoso , Inquéritos e Questionários , Fatores Etários
5.
J Clin Periodontol ; 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38631679

RESUMO

AIM: Treatment of periodontitis, a chronic inflammatory disease driven by biofilm dysbiosis, remains challenging due to patients' poor performance and adherence to the necessary oral hygiene procedures. Novel, artificial intelligence-enabled multimodal-sensing toothbrushes (AI-MST) can guide patients' oral hygiene practices in real-time and transmit valuable data to clinicians, thus enabling effective remote monitoring and guidance. The aim of this trial was to assess the effect of such a system as an adjunct to clinical practice guideline-conform treatment. MATERIALS AND METHODS: This was a single-centre, double-blind, standard-of-care controlled, randomized, parallel-group, superiority trial. Male and female adults with generalized Stage II/III periodontitis were recruited at the Shanghai Ninth People's Hospital, China. Subjects received a standard-of-care oral hygiene regimen or a technology-enabled, theory-based digital intervention consisting of an AI-MST and targeted doctor's guidance by remote micromessaging. Additionally, both groups received guideline-conform periodontal treatment. The primary outcome was the resolution of inflamed periodontal pockets (≥4 mm with bleeding on probing) at 6 months. The intention-to-treat (ITT) analysis included all subjects who received the allocated treatment and at least one follow-up. RESULTS: One hundred patients were randomized and treated (50 tests/controls) between 1 February and 30 November 2022. Forty-eight tests (19 females) and 47 controls (16 females) were analysed in the ITT population. At 6 months, the proportion of inflamed periodontal pockets decreased from 80.7% (95% confidence interval [CI] 76.5-84.8) to 52.3% (47.7-57.0) in the control group, and from 81.4% (77.1-85.6) to 44.4% (39.9-48.9) in the test group. The inter-group difference was 7.9% (1.6-14.6, p < .05). Test subjects achieved better levels of oral hygiene (p < .001). No significant adverse events were observed. CONCLUSIONS: The tested digital health intervention significantly improved the outcome of periodontal therapy by enhancing the adherence and performance of self-performed oral hygiene. The model breaks the traditional model of oral health care and has the potential to improve efficiency and reduce costs (NCT05137392).

6.
Clin Oral Implants Res ; 35(6): 598-608, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38517053

RESUMO

OBJECTIVES: To systematically analyze the accuracy of robotic surgery for dental implant placement. MATERIALS AND METHODS: PubMed, Embase, and Cochrane CENTRAL were searched on October 25, 2023. Model studies or clinical studies reporting the accuracy of robotic surgery for dental implant placement among patients with missing or hopeless teeth were included. Risks of bias in clinical studies were assessed. Meta-analyses were undertaken. RESULTS: Data from 8 clinical studies reporting on 109 patients and 242 implants and 13 preclinical studies were included. Positional accuracy was measured by comparing the implant plan in presurgery CBCT and the actual implant position in postsurgery CBCT. For clinical studies, the pooled (95% confidence interval) platform deviation, apex deviation, and angular deviation were 0.68 (0.57, 0.79) mm, 0.67 (0.58, 0.75) mm, and 1.69 (1.25, 2.12)°, respectively. There was no statistically significant difference between the accuracy of implants placed in partially or fully edentulous patients. For model studies, the pooled platform deviation, apex deviation, and angular deviation were 0.72 (0.58, 0.86) mm, 0.90 (0.74, 1.06) mm, and 1.46 (1.22, 1.70)°, respectively. No adverse event was reported. CONCLUSION: Within the limitation of the present systematic review, robotic surgery for dental implant placement showed suitable implant positional accuracy and had no reported obvious harm. Both robotic systems and clinical studies on robotic surgery for dental implant placement should be further developed.


Assuntos
Implantação Dentária Endóssea , Implantes Dentários , Procedimentos Cirúrgicos Robóticos , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Implantação Dentária Endóssea/métodos , Tomografia Computadorizada de Feixe Cônico
7.
J Med Internet Res ; 26: e55847, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38663010

RESUMO

BACKGROUND: While large language models (LLMs) such as ChatGPT and Google Bard have shown significant promise in various fields, their broader impact on enhancing patient health care access and quality, particularly in specialized domains such as oral health, requires comprehensive evaluation. OBJECTIVE: This study aims to assess the effectiveness of Google Bard, ChatGPT-3.5, and ChatGPT-4 in offering recommendations for common oral health issues, benchmarked against responses from human dental experts. METHODS: This comparative analysis used 40 questions derived from patient surveys on prevalent oral diseases, which were executed in a simulated clinical environment. Responses, obtained from both human experts and LLMs, were subject to a blinded evaluation process by experienced dentists and lay users, focusing on readability, appropriateness, harmlessness, comprehensiveness, intent capture, and helpfulness. Additionally, the stability of artificial intelligence responses was also assessed by submitting each question 3 times under consistent conditions. RESULTS: Google Bard excelled in readability but lagged in appropriateness when compared to human experts (mean 8.51, SD 0.37 vs mean 9.60, SD 0.33; P=.03). ChatGPT-3.5 and ChatGPT-4, however, performed comparably with human experts in terms of appropriateness (mean 8.96, SD 0.35 and mean 9.34, SD 0.47, respectively), with ChatGPT-4 demonstrating the highest stability and reliability. Furthermore, all 3 LLMs received superior harmlessness scores comparable to human experts, with lay users finding minimal differences in helpfulness and intent capture between the artificial intelligence models and human responses. CONCLUSIONS: LLMs, particularly ChatGPT-4, show potential in oral health care, providing patient-centric information for enhancing patient education and clinical care. The observed performance variations underscore the need for ongoing refinement and ethical considerations in health care settings. Future research focuses on developing strategies for the safe integration of LLMs in health care settings.


Assuntos
Autogestão , Humanos , Autogestão/métodos , Inteligência Artificial , Acessibilidade aos Serviços de Saúde , Idioma , Saúde Bucal
8.
J Prosthet Dent ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38991886

RESUMO

STATEMENT OF PROBLEM: Conventional impression techniques for complete arch implant-supported fixed dental prostheses (CIFDPs) are technique sensitive. Stereophotogrammetry (SPG) and intraoral scanning (IOS) may offer alternatives to conventional impression making. PURPOSE: The purpose of this in vitro study was to assess the accuracy and passive fit of IOS with prefabricated aids, SPG, and open tray impression (OI) for CIFDPs with different implant distributions. MATERIAL AND METHODS: Three definitive casts with 4 parallel implants (4-PARA), 4 inclined implants (4-INCL), and 6 parallel implants (6-PARA) were fabricated. Three recording techniques were tested: IOS with prefabricated aids, SPG, and OI. The best and the worst scans were selected to fabricate 18 milled aluminum alloy frameworks. The trueness and precision of distance deviation (∆td and ∆pd), angular deviation (∆tθand ∆pθ), root mean square errors (∆tRMS for ∆pRMS), and passive fit score of frameworks were recorded. Two-way ANOVA was applied. RESULTS: SPG showed the best trueness and precision (95%CI of ∆td/∆tθ/∆tRMS, 31 to 39 µm, 0.22 to 0.28 degrees, 20 to 23 µm; 95%CI of ∆pd/∆pθ/∆pRMS, 9 to 11 µm, 0.06 to 0.08 degrees, 8 to 10 µm), followed by OI (61 to 83 µm, 0.33 to 0.48 degrees, 28 to 48 µm; 66 to 81 µm, 0.29 to 0.38 degrees, 32 to 41 µm) and IOS (143 to 193 µm, 0.37 to 0.50 degrees, 81 to 96 µm; 89 to 111 µm, 0.27 to 0.31 degrees, 51 to 62 µm). Tilted implants were associated with increased distance deviation. Increased implant number was associated with improved recording precision. The passive fit of frameworks was negatively correlated with the RMS error, and the correlation coefficient was -0.65 (P=.003). CONCLUSIONS: SPG had the best accuracy. Implant distributions affected implant precision. The RMS error can be used to evaluate the passive fit of frameworks.

9.
BMC Oral Health ; 24(1): 635, 2024 May 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811930

RESUMO

BACKGROUND: Periodontitis is strongly associated with type 2 diabetes (T2D) that results in serious complications and mortality. However, the pathogenic role of periodontitis in the development of T2D and the underlain mechanism have not been fully elucidated. METHODS: A Mendelian randomization (MR) was performed to estimate the causality between two diseases. Bioinformatics tools, including gene ontology and pathway enrichment analyses, were employed to analyze the common differentially expressed genes (DEGs) in periodontitis and T2D. MR and colocalization analyses were then utilized to investigate the causal associations between potential pathogenic gene expression and the risk of T2D. Single cell-type expression analysis was further performed to detect the cellular localization of these genes. RESULTS: Genetically predicted periodontitis was associated with a higher risk of T2D (OR, 1.469; 95% CI, 1.117-1.930; P = 0.006) and insulin resistance (OR 1.034; 95%CI 1.001-1.068; P = 0.041). 79 common DEGs associated with periodontitis and T2D were then identified and demonstrated enrichment mainly in CXC receptor chemokine receptor binding and interleutin-17 signaling pathway. The integration of GWAS with the expression quantitative trait locis of these genes from the peripheral blood genetically prioritized 6 candidate genes, including 2 risk genes (RAP2A, MCUR1) and 4 protective genes (WNK1, NFIX, FOS, PANX1) in periodontitis-related T2D. Enriched in natural killer cells, RAP2A (OR 4.909; 95% CI 1.849-13.039; P = 0.001) demonstrated high risk influence on T2D, and exhibited strong genetic evidence of colocalization (coloc.abf-PPH4 = 0.632). CONCLUSIONS: This study used a multi-omics integration method to explore causality between periodontitis and T2D, and revealed molecular mechanisms using bioinformatics tools. Periodontitis was associated with a higher risk of T2D. MCUR1, RAP2A, FOS, PANX1, NFIX and WNK1 may play important roles in the pathogenesis of periodontitis-related T2D, shedding light on the development of potential drug targets.


Assuntos
Biologia Computacional , Diabetes Mellitus Tipo 2 , Análise da Randomização Mendeliana , Periodontite , Humanos , Diabetes Mellitus Tipo 2/genética , Diabetes Mellitus Tipo 2/complicações , Periodontite/genética , Periodontite/complicações , Estudo de Associação Genômica Ampla
10.
J Clin Periodontol ; 50(4): 533-546, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36632002

RESUMO

AIM: To evaluate the relative efficacy and confidence in the precision of the results of different surgical interventions for immediate implant placement in the anterior area. MATERIALS AND METHODS: Electronic searches were performed in PubMed, Embase, and Cochrane CENTRAL. Randomized controlled trials comparing different surgical techniques in anterior jaws for type 1 implant placement were included. Outcome measures included implant survival (primary outcome), buccal bone thickness (BBT) reduction, and mid-facial soft tissue recession (MSTR). Risks of bias assessment, network meta-analysis (NMA), sensitivity analysis, and quality-of-evidence assessment were performed. RESULTS: Twenty-two studies reporting on 948 subjects and 5 surgical interventions were included. Fourteen early failures were reported. Compared with open-flap surgery without tissue augmentation (F-N) and looking at BBT preservation, NMA showed that there was moderate confidence that flapless surgery with hard tissue augmentation (FL-HTA) was better than flapless surgery without tissue augmentation (FL-N) or open-flap surgery with hard tissue augmentation (F-HTA) (mean difference -0.8 mm, 95% confidence interval: -1.1 to -0.5 mm; -0.6 mm, -0.9 to -0.4 mm; and -0.5 mm, -0.7 to -0.3 mm, respectively). There was moderate confidence that flapless surgery with hard and soft tissue augmentation (FL-HTA&STA) could significantly prevent MSTR compared with FL-HTA (-0.5 mm, -0.7 to -0.3 mm) and FL-N (-0.6 mm, -1.2 to -0.04 mm). However, there was no significant additional benefit in BBT with the FL-HTA&STA approach compared to the FL-HTA approach (-0.30 mm, -0.81 to 0.21 mm). CONCLUSIONS: For immediate implant placement in the anterior areas, the FL-HTA approach better preserves BBT (moderate confidence); adding STA improves the stability of the mid-facial soft tissue level (moderate confidence) but at the expense of BBT (low confidence).


Assuntos
Implantes Dentários , Carga Imediata em Implante Dentário , Humanos , Implantação Dentária Endóssea/métodos , Metanálise em Rede , Maxila/cirurgia , Carga Imediata em Implante Dentário/métodos , Estética Dentária , Ensaios Clínicos Controlados Aleatórios como Assunto
11.
J Clin Periodontol ; 50 Suppl 25: 5-21, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37143289

RESUMO

AIM: Lack of consistently reported outcomes limits progress in evidence-based implant dentistry and quality of care. The objective of this initiative was to develop a core outcome set (COS) and measurements for implant dentistry clinical trials (ID-COSM). MATERIALS AND METHODS: This Core Outcome Measures in Effectiveness Trials (COMET)-registered international initiative comprised six steps over 24 months: (i) systematic reviews of outcomes reported in the last 10 years; (ii) international patient focus groups; (iii) a Delphi project with a broad range of stakeholders (care providers, clinical researchers, methodologists, patients and industry representatives); (iv) expert group discussions organizing the outcomes in domains using a theoretical framework and identifying the COSs; (v) identification of valid measurement systems to capture the different domains and (vi) final consensus and formal approval involving experts and patients. The methods were modified from the best practice approach following the Outcome Measures in Rheumatoid Arthritis Clinical Trial and COMET manuals. RESULTS: The systematic reviews and patient focus groups identified 754 (665 + 89, respectively) relevant outcome measures. After elimination of redundancies and duplicates, 111 were formally assessed in the Delphi project. By applying pre-specified filters, the Delphi process identified 22 essential outcomes. These were reduced to 13 after aggregating alternative assessments of the same features. The expert committee organized them into four core outcome areas: (i) pathophysiology, (ii) implant/prosthesis lifespan, (iii) life impact and (iv) access to care. In each area, core outcomes were identified to capture both the benefits and harms of therapy. Mandatory outcome domains included assessment of surgical morbidity and complications, peri-implant tissue health status, intervention-related adverse events, complication-free survival and overall patient satisfaction and comfort. Outcomes deemed mandatory in specific circumstances comprised function (mastication, speech, aesthetics and denture retention), quality of life, effort for treatment and maintenance and cost effectiveness. Specialized COSs were identified for bone and soft-tissue augmentation procedures. The validity of measurement instruments ranged from international consensus (peri-implant tissue health status) to early identification of important outcomes (patient-reported outcomes identified by the focus groups). CONCLUSIONS: The ID-COSM initiative reached a consensus on a core set of mandatory outcomes for clinical trials in implant dentistry and/or soft tissue/bone augmentation. Adoption in future protocols and reporting on the respective domain areas by currently ongoing trials will contribute to improving evidence-informed implant dentistry and quality of care.


Assuntos
Implantes Dentários , Projetos de Pesquisa , Humanos , Resultado do Tratamento , Consenso , Qualidade de Vida , Estética Dentária , Avaliação de Resultados em Cuidados de Saúde
12.
Clin Oral Implants Res ; 34(12): 1330-1341, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37655630

RESUMO

OBJECTIVES: To compare the clinical, radiographic, and immunological outcomes between one-piece versus two-piece zirconia abutments supported single implant crowns in the esthetic region. MATERIALS AND METHODS: The study followed a split-mouth, double-blind, and randomized controlled clinical design for a duration of 3 years. Twenty-two eligible patients with 44 implants were randomly assigned to two groups: Group 1 (one-piece zirconia abutment with zirconia base, n = 22) and Group 2 (two-piece zirconia abutment with titanium base, n = 22). The primary outcome was the technical complication rate. Additionally, survival rates, cytokines concentrations in peri-implant crevicular fluid (PICF), peri-implant conditions, marginal bone loss, and pink/white esthetics score (PES/WES) were assessed as secondary outcomes. RESULTS: Twelve of 22 patients attended the 1-year follow-up (due to the COVID pandemic), and 19 patients attended the 3-year examination. Two abutments in Group 1 were fractured after 10 and 12 months in function. Additionally, one screw loosening occurred in Group 1 at 1-year follow-up. The 3-year technical complication rate was significantly higher in Group 1 than that in Group 2 (15.79% vs. 0%, p < .001). The 3-year implant survival rate was 100% in both groups. The concentration of IFN-γ in PICF was significantly upregulated in Group 2 (p = .018). Furthermore, the IL-6 concentration was positively correlated with BOP% (p = .020). CONCLUSIONS: Two-piece zirconia abutments exhibited superior technical performance compared to one-piece designs during a 3-year follow-up in the anterior region. However, further long-term research is necessary to verify the immunological stability of two-piece zirconia abutments.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Humanos , Falha de Restauração Dentária , Dente Suporte , Estética Dentária , Coroas , Zircônio , Boca , Titânio , Projeto do Implante Dentário-Pivô
13.
Clin Oral Implants Res ; 34(1): 1-12, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36245267

RESUMO

OBJECTIVES: Simplification and standardization of interventions are critical challenges to improving performance in implant dentistry. This study aimed to systematically identify and schematically present the evidence base of the implant dentistry surgical interventions for the anterior maxilla as a basis for further development and standardization. METHODS: Electronic searches were conducted in PubMed, Embase and Cochrane CENTRAL. Primary clinical studies reporting surgical interventions in the anterior maxilla, with a sample size of at least ten patients, were included. Bibliometric information and study details were extracted. Descriptive analysis and a mind map approach were used to describe the documentation of different surgical interventions. RESULTS: Two hundred and seventy-two studies reporting on 9001 patients were included. Within the past two decades, the number of literatures on implant placement in the anterior maxilla has increased dramatically (7 studies before 2005, 151 studies after 2016). Overall, the evidence map identified six primary operations and 33 variations. For hopeless tooth extraction, immediate implant placement was the most frequently reported (141 studies, 4670 patients); flapless implant placement with hard tissue augmentation and immediate provisionalization was the most commonly reported variation (33 studies, 987 patients). Type 3/4 implant placement (62 studies, 1902 patients) and implant site augmentation (33 studies, 788 patients) were frequently reported for missing teeth. Geographical differences were observed, with type 2 placement studies almost exclusively from Europe. CONCLUSIONS: Research on immediate implant placement was the most reported surgical intervention in the anterior maxilla. Hard tissue augmentation was frequently reported simultaneously with or before implant placement. Immediate provisionalization was mainly used for type 1 implant placement. The finding that six primary operations with 33 variations have been reported indicates the need for additional research to simplify and consolidate the surgical approach.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Humanos , Implantação Dentária Endóssea , Maxila/cirurgia , Estética Dentária
14.
Clin Oral Implants Res ; 34(8): 839-849, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37309242

RESUMO

OBJECTIVES: Multiple generations of medical robots have revolutionized surgery. Their application to dental implants is still in its infancy. Co-operating robots (cobots) have great potential to improve the accuracy of implant placement, overcoming the limitations of static and dynamic navigation. This study reports the accuracy of robot-assisted dental implant placement in a preclinical model and further applies the robotic system in a clinical case series. MATERIALS AND METHODS: In model analyses, the use of a lock-on structure at robot arm-handpiece was tested in resin arch models. In a clinical case series, patients with single missing teeth or edentulous arch were included. Robot-assisted implant placement was performed. Surgery time was recorded. Implant platform deviation, apex deviation, and angular deviation were measured. Factors influencing implant accuracy were analyzed. RESULTS: The in vitro results showed that with a lock-on structure, the mean (SD) of platform deviation, apex deviation, and angular deviation were 0.37 (0.14) mm, 0.44 (0.17) mm, and 0.75 (0.29)°, respectively. Twenty-one patients (28 implants) were included in the clinical case series, 2 with arches and 19 with single missing teeth. The median surgery time for single missing teeth was 23 (IQ range 20-25) min. The surgery time for the two edentulous arches was 47 and 70 min. The mean (SD) of platform deviation, apex deviation, and angular deviation was 0.54 (0.17) mm, 0.54 (0.11) mm, and 0.79 (0.22)° for single missing teeth and for 0.53 (0.17) mm, 0.58 (0.17) mm, and 0.77 (0.26)° for an edentulous arch. Implants placed in the mandible had significantly larger apex deviation than those in the maxilla. CONCLUSION: Cobot-assisted dental implant placement showed excellent positional accuracy and safety in both the in vitro study and the clinical case series. More technological development and clinical research are needed to support the introduction of robotic surgery in oral implantology. Trial registered in ChiCTR2100050885.


Assuntos
Implantes Dentários , Boca Edêntula , Robótica , Cirurgia Assistida por Computador , Perda de Dente , Humanos , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea/métodos , Tecnologia Háptica , Imageamento Tridimensional , Boca Edêntula/cirurgia , Cirurgia Assistida por Computador/métodos
15.
Artigo em Inglês | MEDLINE | ID: mdl-37746813

RESUMO

OBJECTIVES: The aim of this clinical study was to compare the accuracy of intraoral scan system (IOS) with prefabricated aids and stereophotogrammetry (SPG) compared with open tray implant impression (OI) for complete-arch implant-supported fixed dental prostheses (CIFDP). MATERIALS AND METHODS: Patients needing CIFDP were enrolled in this study. OI, reference standard, IOS with prefabricated aids, and SPG were performed for each patient. Distance and angle deviations between all pairs of abutment analogs, root mean square (RMS) errors between the aligned test and reference model, and chairside time were measured. The effect of inter-abutment distance, jaw (maxilla or mandible), number of implants, and arch length on deviations was analyzed. The mixed effect model was applied to analyze deviations and RMS errors. RESULTS: Fifteen consecutive individuals (6 females and 9 males, 47-77 years old) with 22 arches (9 upper and 13 lower jaws) and 115 implants were included. There was no significant difference in distance deviation comparing SPG and IOS with OI (p > .05). IOS showed a significantly greater angle deviation and RMS errors than SPG (median 0.40° vs. 0.31°, 69 µm vs. 45 µm, p < .01). The inter-abutment distance was negatively correlated with the accuracy of SPG and IOS (p < .05). The chairside time for IOS, SPG, and OI was 10.49 ± 3.50, 14.71 ± 2.86, and 20.20 ± 3.01 min, respectively (p < .01). CONCLUSIONS: The accuracy of SPG and IOS with prefabricated aids was comparable. IOS was the most efficient workflow.

16.
Clin Oral Implants Res ; 34 Suppl 25: 4-21, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37232121

RESUMO

AIM: Lack of consistently reported outcomes limits progress in evidence-based implant dentistry and quality of care. The objective of this initiative was to develop a core outcome set (COS) and measurements for implant dentistry clinical trials (ID-COSM). MATERIALS AND METHODS: This Core Outcome Measures in Effectiveness Trials (COMET)-registered international initiative comprised six steps over 24 months: (i) systematic reviews of outcomes reported in the last 10 years; (ii) international patient focus groups; (iii) a Delphi project with a broad range of stakeholders (care providers, clinical researchers, methodologists, patients and industry representatives); (iv) expert group discussions organizing the outcomes in domains using a theoretical framework and identifying the COSs; (v) identification of valid measurement systems to capture the different domains and (vi) final consensus and formal approval involving experts and patients. The methods were modified from the best practice approach following the Outcome Measures in Rheumatoid Arthritis Clinical Trial and COMET manuals. RESULTS: The systematic reviews and patient focus groups identified 754 (665 + 89, respectively) relevant outcome measures. After elimination of redundancies and duplicates, 111 were formally assessed in the Delphi project. By applying pre-specified filters, the Delphi process identified 22 essential outcomes. These were reduced to 13 after aggregating alternative assessments of the same features. The expert committee organized them into four core outcome areas: (i) pathophysiology, (ii) implant/prosthesis lifespan, (iii) life impact and (iv) access to care. In each area, core outcomes were identified to capture both the benefits and harms of therapy. Mandatory outcome domains included assessment of surgical morbidity and complications, peri-implant tissue health status, intervention-related adverse events, complication-free survival and overall patient satisfaction and comfort. Outcomes deemed mandatory in specific circumstances comprised function (mastication, speech, aesthetics and denture retention), quality of life, effort for treatment and maintenance and cost effectiveness. Specialized COSs were identified for bone and soft-tissue augmentation procedures. The validity of measurement instruments ranged from international consensus (peri-implant tissue health status) to early identification of important outcomes (patient-reported outcomes identified by the focus groups). CONCLUSIONS: The ID-COSM initiative reached a consensus on a core set of mandatory outcomes for clinical trials in implant dentistry and/or soft tissue/bone augmentation. Adoption in future protocols and reporting on the respective domain areas by currently ongoing trials will contribute to improving evidence-informed implant dentistry and quality of care.


Assuntos
Implantes Dentários , Projetos de Pesquisa , Humanos , Resultado do Tratamento , Consenso , Qualidade de Vida , Avaliação de Resultados em Cuidados de Saúde , Técnica Delphi
17.
J Prosthet Dent ; 130(2): 212-218, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34776266

RESUMO

STATEMENT OF PROBLEM: Clinical studies on the accuracy of the photogrammetric imaging technique for complete arch implant-supported fixed dental prostheses are lacking. PURPOSE: The purpose of this clinical study was to evaluate the accuracy (trueness) of photogrammetric imaging for complete arch implant-supported prostheses by comparing photogrammetric imaging with verified conventional splinted impressions. MATERIAL AND METHODS: Completely edentulous arches with at least 4 implants were included. Both photogrammetric imaging and conventional splinted impressions were performed in each jaw. The conventional casts were verified and scanned by using a laboratory scanner as the control. The distances and angulations between different implants (interimplant distances and interimplant angulations) were measured in all photogrammetric and conventional standard tessellation language (STL) files by using a reverse-engineering software program. The distance deviations between the photogrammetric and conventional impressions of the same participant were calculated as the primary outcome, and the angular deviations were obtained as the secondary outcome with descriptive analyses. The comparison between distance deviations and the clinically acceptable level of deviations (150 µm) was conducted by using the 1-sample t test. The effect of interimplant distances, interimplant angulations, and jaw (maxilla or mandible) on deviations was analyzed by using the Spearman correlation analysis, Kruskal-Wallis test, or Student t test, depending on the type of data (α=0.05 for all tests). RESULTS: Fourteen edentulous jaws were included. The overall distance deviation of photogrammetric imaging was 70 ±57 µm, significantly lower than the clinically acceptable level of misfit (150 µm; P<.001). The overall angular deviation was 0.432 ±0.348 degrees. The distance deviations were correlated with interimplant distances with a correlation coefficient (r) of 0.371 (P=.002). Interimplant angulation was not correlated with distance or angular deviations (P=.914, P=.914). Jaw was not correlated with distance or angular deviations either (P=.190, P=.209). CONCLUSIONS: The accuracy (trueness) of photogrammetric imaging of complete arch implant-supported prostheses was within a clinically acceptable range of errors. Distance deviations increased with greater interimplant distances. Interimplant angulations and jaw (maxilla or mandible) had no significant effect on the accuracy of photogrammetric imaging.


Assuntos
Implantes Dentários , Arcada Edêntula , Humanos , Técnica de Moldagem Odontológica , Modelos Dentários , Arcada Edêntula/diagnóstico por imagem , Fotogrametria , Desenho Assistido por Computador , Imageamento Tridimensional/métodos , Arco Dental/diagnóstico por imagem , Arco Dental/cirurgia
18.
J Periodontal Res ; 57(4): 768-779, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35575900

RESUMO

BACKGROUND AND OBJECTIVES: Assessment of biomarkers, specifically active matrix metalloproteinase-8 (aMMP-8), in saliva/oral rinses is a promising diagnostic approach for periodontal health and disease. Different oral fluids have specific advantages and limitations. This study investigates the effect of sampling different fluids on the accuracy of an aMMP-8 point of care test (POCT). METHODS: Unstimulated whole saliva, a first, and a second oral rinse were sequentially taken from 95 consecutive adults. aMMP-8 was quantitatively determined with a lateral flow immunoassay (index test). A full-mouth periodontal examination was used to establish a diagnosis according to the 2017 World Workshop classification of periodontal diseases (reference standard). Diagnostic measures of the area under the receiver operating characteristic curve (AUROC), sensitivity, and specificity were assessed and compared. RESULTS: In all oral fluid samples, periodontitis patients (N = 61) had significantly elevated aMMP-8 levels and increased test positivity rates compared with subjects with periodontal health or gingivitis (N = 34). The intra-individual comparison showed that aMMP-8 levels were significantly higher in 1st oral rinse compared with other samples (1st oral rinse > saliva = 2nd oral rinse, p = .007). The aMMP-8 test using 1st oral rinse exhibited the best accuracy for detecting periodontitis with a sensitivity of 80.3%, a specificity of 67.8% and an AUROC of 0.740. CONCLUSIONS: A 30-second oral rinse with water omitting the prerinse provided the best accuracy to discriminate periodontal health and disease with an aMMP-8 POCT. This regimen seems promising for further studies in large representative populations to verify the current findings.


Assuntos
Metaloproteinase 8 da Matriz , Periodontite , Adulto , Nível de Saúde , Humanos , Antissépticos Bucais , Periodontite/diagnóstico , Testes Imediatos , Saliva
19.
J Clin Periodontol ; 49(2): 144-152, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34747036

RESUMO

AIM: Analysis of distribution of p-values of continuous differences between test and controls after randomization provides evidence of unintentional error, non-random sampling, or data fabrication in randomized controlled trials (RCTs). We assessed evidence of highly unusual distributions of baseline characteristics of subjects enrolled in clinical trials in implant dentistry. MATERIALS AND METHODS: RCTs published between 2005 and 2020 were systematically searched in Pubmed, Embase, and Cochrane databases. Baseline patient data were extracted from full text articles by two independent assessors. The hypothesis of non-random sampling was tested by comparing the expected and the observed distribution of the p-values of differences between test and controls after randomization. RESULTS: One-thousand five-hundred and thirty-eight unique RCTs were identified, of which 409 (26.6%) did not report baseline characteristics of the population, and 671 (43.6%) reported data in forms other than mean and standard deviation and could not be used to assess their random sampling. Four-hundred and fifty-eight trials with 1449 baseline variables in the form of mean and standard deviation were assessed. The study observed an over-representation of very small p-values [<.001, 1.38%, 95% confidence interval (CI) 0.85-2.12 compared to the expected 0.10%, 95% CI 0.00-0.26]. No evidence of over-representation of larger p-values was observed. Unusual distributions were present in 2.38% of RCTs and more frequent in non-registered trials, in studies supported by non-industry funding, and in multi-centre RCTs. CONCLUSIONS: The inability to assess random sampling due to insufficient reporting in 26.6% of trials requires attention. In trials reporting suitable baseline data, unusual distributions were uncommon, and no evidence of data fabrication was detected, but there was evidence of non-random sampling. Continued efforts are necessary to ensure high integrity and trust in the evidence base of the field.


Assuntos
Ensaios Clínicos como Assunto , Odontologia , Projetos de Pesquisa , Humanos , Fatores de Risco
20.
Clin Oral Implants Res ; 33(12): 1183-1198, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36251562

RESUMO

OBJECTIVE: The objective of this study is to systematically analyze the effects of diabetes mellitus/hyperglycemia (DM/HG) on peri-implant biomarkers and clinical and radiographic outcomes in patients undergoing implant treatment. MATERIALS AND METHODS: PubMed, Embase, and the Cochrane Central Register of Controlled Trials databases were searched up to March 2022. Studies reporting on peri-implant biomarkers, and clinical and radiographic outcomes in patients with different glycemic status levels (HbA1c) were included. Several analyses were conducted, such as meta-analysis, sensitivity analysis, dose-response meta-analysis (DRMA), and robust error meta-regression (REMR). RESULTS: A total of 10 studies and 634 participants were included for analysis, with a maximum follow-up of six years in function. The level of advanced glycation end products (AGEs) in peri-implant crevicular fluid (PICF) was significantly higher in the DM/HG group than in the healthy group (p < .01). Subgroup analyses showed that a set of negative regulators of bone metabolism (including IL-6, TNF-α, IL-8, and RANKL) were significantly higher in the DM/HG group (p = .01). Implant survival rate (100%) was not compromised in patients with an HbA1c level less than 10%. Outcomes of implant stability quotient (ISQ) values, bleeding on probing rate (BOP%), probing depth (PD), and marginal bone loss (MBL) in the DM/HG group were significantly worse than those in the healthy group (p = .04, <0.01, 0.01, <0.01, respectively). DRMA results showed AGE accumulation in PICF, PD, and MBL worsened in a dose-response dependent manner with elevated HbA1c levels (<6%, 6-8%, >8%; p = .04, 0.02, <0.01, respectively). CONCLUSIONS: DM/HG can upregulate negative regulators of bone metabolism and compromise peri-implant health. In addition, there are dose-response relationships between HbA1c levels and AGE accumulation in PICF, PD, and MBL.


Assuntos
Implantes Dentários , Diabetes Mellitus , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA