Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
Endoscopy ; 55(2): 129-137, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36044915

RESUMO

BACKGROUND : The advantage of using the macroscopic on-site evaluation (MOSE) technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) performed with 22G Franseen needles has not been investigated. We aimed to compare EUS-FNB with MOSE vs. EUS-FNB performed with three needle passes. METHODS : This randomized trial involved 10 Italian referral centers. Consecutive patients referred for EUS-FNB of pancreatic or nonpancreatic solid lesions were included in the study and randomized to the two groups. MOSE was performed by gross visualization of the collected material by the endoscopists and considered adequate when a white/yellowish aggregate core longer than 10 mm was retrieved. The primary outcome was diagnostic accuracy. Secondary outcomes were specimen adequacy, number of needle passes, and safety. RESULTS : 370 patients with 234 pancreatic lesions (63.2 %) and 136 nonpancreatic lesions (36.8 %) were randomized (190 EUS-FNB with MOSE and 180 with standard EUS-FNB). No statistically significant differences were found between EUS-FNB with MOSE and conventional EUS-FNB in terms of diagnostic accuracy (90.0 % [95 %CI 84.8 %-93.9 %] vs. 87.8 % [95 %CI 82.1 %-92.2 %]; P = 0.49), sample adequacy (93.1 % [95 %CI 88.6 %-96.3 %] vs. 95.5 % [95 %CI 91.4 %-98 %]; P = 0.31), and rate of adverse events (2.6 % vs. 1.1 %; P = 0.28). The median number of passes was significantly lower in the EUS-FNB with MOSE group (1 vs. 3; P < 0.001). CONCLUSIONS : The accuracy of EUS-FNB with MOSE is noninferior to that of EUS-FNB with three needle passes. MOSE reliably assesses sample adequacy and reduces the number of needle passes required to obtain the diagnosis with a 22G Franseen needle.


Assuntos
Neoplasias Pancreáticas , Humanos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Biópsia Guiada por Imagem , Pâncreas/diagnóstico por imagem , Pâncreas/patologia , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/patologia
2.
Endoscopy ; 55(3): 225-234, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-35915956

RESUMO

BACKGROUND : It is unknown whether there is an advantage to using the wet-suction or slow-pull technique during endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) with new-generation needles. We aimed to compare the performance of each technique in EUS-FNB. METHODS: This was a multicenter, randomized, single-blind, crossover trial including patients with solid lesions of ≥ 1 cm. Four needle passes with 22 G fork-tip or Franseen-type needles were performed, alternating the wet-suction and slow-pull techniques in a randomized order. The primary outcome was the histological yield (samples containing an intact piece of tissue of at least 550 µm). Secondary end points were sample quality (tissue integrity and blood contamination), diagnostic accuracy, and adequate tumor fraction. RESULTS: Overall, 210 patients with 146 pancreatic and 64 nonpancreatic lesions were analyzed. A tissue core was retrieved in 150 (71.4 %) and 129 (61.4 %) cases using the wet-suction and the slow-pull techniques, respectively (P = 0.03). The mean tissue integrity score was higher using wet suction (P = 0.02), as was the blood contamination of samples (P < 0.001). In the two subgroups of pancreatic and nonpancreatic lesions, tissue core rate and tissue integrity score were not statistically different using the two techniques, but blood contamination was higher with wet suction. Diagnostic accuracy and tumor fraction did not differ between the two techniques. CONCLUSION: Overall, the wet-suction technique in EUS-FNB resulted in a higher tissue core procurement rate compared with the slow-pull method. Diagnostic accuracy and the rate of samples with adequate tumor fraction were similar between the two techniques.


Assuntos
Neoplasias Pancreáticas , Humanos , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/métodos , Sucção/métodos , Estudos Cross-Over , Método Simples-Cego , Pâncreas/diagnóstico por imagem , Pâncreas/patologia
3.
Gastroenterology ; 161(3): 899-909.e5, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34116031

RESUMO

BACKGROUND AND AIMS: The benefit of rapid on-site evaluation (ROSE) on the diagnostic accuracy of endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) has never been evaluated in a randomized study. This trial aimed to test the hypothesis that in solid pancreatic lesions (SPLs), diagnostic accuracy of EUS-FNB without ROSE was not inferior to that of EUS-FNB with ROSE. METHODS: A noninferiority study (noninferiority margin, 5%) was conducted at 14 centers in 8 countries. Patients with SPLs requiring tissue sampling were randomly assigned (1:1) to undergo EUS-FNB with or without ROSE using new-generation FNB needles. The touch-imprint cytology technique was used to perform ROSE. The primary endpoint was diagnostic accuracy, and secondary endpoints were safety, tissue core procurement, specimen quality, and sampling procedural time. RESULTS: Eight hundred patients were randomized over an 18-month period, and 771 were analyzed (385 with ROSE and 386 without). Comparable diagnostic accuracies were obtained in both arms (96.4% with ROSE and 97.4% without ROSE, P = .396). Noninferiority of EUS-FNB without ROSE was confirmed with an absolute risk difference of 1.0% (1-sided 90% confidence interval, -1.1% to 3.1%; noninferiority P < .001). Safety and sample quality of histologic specimens were similar in both groups. A significantly higher tissue core rate was obtained by EUS-FNB without ROSE (70.7% vs. 78.0%, P = .021), with a significantly shorter mean sampling procedural time (17.9 ± 8.8 vs 11.7 ± 6.0 minutes, P < .0001). CONCLUSIONS: EUS-FNB demonstrated high diagnostic accuracy in evaluating SPLs independently on execution of ROSE. When new-generation FNB needles are used, ROSE should not be routinely recommended. (ClinicalTrial.gov number NCT03322592.).


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pancreáticas/patologia , Avaliação Rápida no Local , Idoso , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Reprodutibilidade dos Testes
4.
Gastrointest Endosc ; 95(1): 115-122, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34339667

RESUMO

BACKGROUND AND AIMS: Electrocautery-tip lumen-apposing metal stents (EC-LAMSs) have extended the indications of therapeutic EUS. We aimed to retrospectively evaluate safety and technical and clinical success of a newly developed EC-LAMS, the Hot-Spaxus (Taewoong Medical Co, Gimpo, Korea), for various EUS-guided procedures. METHODS: We included and retrospectively analyzed consecutive patients at 8 tertiary care referral centers who had undergone EUS interventional procedures using the Hot-Spaxus between October 2018 and February 2021. RESULTS: Of 58 included patients (male-to-female, 36:22; mean age, 63.5 ± 14.9 years), 29 had undergone pancreatic fluid collection drainage (50%), 22 (37.9%) biliary drainage for malignant distal obstruction, 3 (5.1%) gallbladder drainage for acute cholecystitis, 3 gastroenteroanastomoses, and 1 (1.7%) pelvic collection drainage. Technical success was achieved in 54 of 58 patients (93.1%) and clinical success in all 58. Adverse events occurred in 6 patients (11.1%): 2 early (3.7%), 1 late (1.8%), and 3 long term (5.6%). The outcomes were similar to those observed in a control group of patients treated with the Hot-Axios (Boston Scientific, Marlborough, Mass, USA), the other available EC-LAMS. CONCLUSIONS: Our study showed that the novel EC-LAMS has high technical and clinical success rates for various interventional EUS indications. Future multicenter prospective studies will better clarify the role of this new EC-LAMS for different indications.


Assuntos
Endossonografia , Stents , Idoso , Drenagem , Eletrocoagulação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Ultrassonografia de Intervenção
5.
Endoscopy ; 54(1): 45-51, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33285583

RESUMO

BACKGROUND: To date, no scale has been validated to assess bubbles associated with bowel preparation. This study aimed to develop and assess the reliability of a novel scale - the Colon Endoscopic Bubble Scale (CEBuS). METHODS: This was a multicenter, prospective, observational study with two online evaluation phases of 45 randomly distributed still colonoscopy images (15 per scale grade). Observers assessed images twice, 2 weeks apart, using CEBuS (CEBuS-0 - no or minimal bubbles, covering < 5 % of the surface; CEBuS-1 - bubbles covering 5 %-50 %; CEBuS-2 - bubbles covering > 50 %) and reporting the clinical action (do nothing; wash with water; wash with simethicone). RESULTS: CEBuS provided high levels of agreement both in evaluation Phase 1 (4 experts) and Phase 2 (6 experts and 13 non-experts), with almost perfect intraobserver reliability: kappa 0.82 (95 % confidence interval 0.75-0.88) and 0.86 (0.85-0.88); interobserver agreement - intraclass correlation coefficient (ICC) 0.83 (0.73-0.89) and 0.90 (0.86-0.94). Previous endoscopic experience had no influence on agreement among experts vs. non-experts: kappa 0.86 (0.80-0.91) vs. 0.87 (0.84-0.89) and ICC 0.91 (0.87-0.94) vs. 0.90 (0.86-0.94), respectively. Interobserver agreement on clinical action was ICC 0.63 (0.43-0.78) in Phase 1 and 0.77 (0.68-0.84) in Phase 2. Absolute agreement on clinical action per scale grade was 85 % (82-88) for CEBuS-0, 21 % (16-26) for CEBuS-1, and 74 % (70-78) for CEBuS-2. CONCLUSION: CEBuS proved to be a reliable instrument to standardize the evaluation of colonic bubbles during colonoscopy. Assessment in daily practice is warranted.


Assuntos
Colonoscopia , Simeticone , Colo/diagnóstico por imagem , Humanos , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes
6.
Dig Dis ; 40(4): 526-529, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34348270

RESUMO

BACKGROUND AND STUDY AIMS: Recently, a new electrocautery lumen-apposing metal stent (EC-LAMS) has been launched. The primary aim of our study was to assess the feasibility of the freehand placement with intra-channel release of the new EC-LAMS. The secondary aims were to assess technical and clinical outcomes and rates of adverse events. PATIENTS AND METHODS: We retrospectively evaluated 5 patients (3 F; mean age: 75.6 ± 14.6 years) who underwent new EC-LAMS placement for different indications (cholecystitis, malignant biliary obstruction, and malignant gastric outlet obstruction). We described all the procedures of EC-LAMS placement, providing also a video of one of them (see online suppl. material; for all online suppl. material, see www.karger.com/doi/10.1159/000518539). RESULTS: Technical and clinical success was achieved in all patients who underwent new EC-LAMS placement, and no AEs were experienced. All of the EC-LAMS were placed using the freehand technique with intra-channel release. CONCLUSIONS: Our initial experience with the new EC-LAMS showed a good performance of this device for different indications, especially if the stents are placed freehand and with intra-channel release. Further studies are needed to confirm our preliminary data and first impression about this new EC-LAMS.


Assuntos
Eletrocoagulação , Stents , Idoso , Idoso de 80 Anos ou mais , Eletrocoagulação/métodos , Humanos , Metais , Pessoa de Meia-Idade , Encaminhamento e Consulta , Estudos Retrospectivos , Stents/efeitos adversos
7.
Gastroenterology ; 159(2): 512-520.e7, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32371116

RESUMO

BACKGROUND & AIMS: One-fourth of colorectal neoplasias are missed during screening colonoscopies; these can develop into colorectal cancer (CRC). Deep learning systems allow for real-time computer-aided detection (CADe) of polyps with high accuracy. We performed a multicenter, randomized trial to assess the safety and efficacy of a CADe system in detection of colorectal neoplasias during real-time colonoscopy. METHODS: We analyzed data from 685 subjects (61.32 ± 10.2 years old; 337 men) undergoing screening colonoscopies for CRC, post-polypectomy surveillance, or workup due to positive results from a fecal immunochemical test or signs or symptoms of CRC, at 3 centers in Italy from September through November 2019. Patients were randomly assigned (1:1) to groups who underwent high-definition colonoscopies with the CADe system or without (controls). The CADe system included an artificial intelligence-based medical device (GI-Genius, Medtronic) trained to process colonoscopy images and superimpose them, in real time, on the endoscopy display a green box over suspected lesions. A minimum withdrawal time of 6 minutes was required. Lesions were collected and histopathology findings were used as the reference standard. The primary outcome was adenoma detection rate (ADR, the percentage of patients with at least 1 histologically proven adenoma or carcinoma). Secondary outcomes were adenomas detected per colonoscopy, non-neoplastic resection rate, and withdrawal time. RESULTS: The ADR was significantly higher in the CADe group (54.8%) than in the control group (40.4%) (relative risk [RR], 1.30; 95% confidence interval [CI], 1.14-1.45). Adenomas detected per colonoscopy were significantly higher in the CADe group (mean, 1.07 ±1.54) than in the control group (mean 0.71 ± 1.20) (incidence rate ratio, 1.46; 95% CI, 1.15-1.86). Adenomas 5 mm or smaller were detected in a significantly higher proportion of subjects in the CADe group (33.7%) than in the control group (26.5%; RR, 1.26; 95% CI, 1.01-1.52), as were adenomas of 6 to 9 mm (detected in 10.6% of subjects in the CADe group vs 5.8% in the control group; RR, 1.78; 95% CI, 1.09-2.86), regardless of morphology or location. There was no significant difference between groups in withdrawal time (417 ± 101 seconds for the CADe group vs 435 ± 149 for controls; P = .1) or proportion of subjects with resection of non-neoplastic lesions (26.0% in the CADe group vs 28.7% of controls; RR, 1.00; 95% CI, 0.90-1.12). CONCLUSIONS: In a multicenter, randomized trial, we found that including CADe in real-time colonoscopy significantly increases ADR and adenomas detected per colonoscopy without increasing withdrawal time. ClinicalTrials.gov no: 04079478.


Assuntos
Adenoma/diagnóstico , Colonoscopia/métodos , Neoplasias Colorretais/diagnóstico , Aprendizado Profundo , Interpretação de Imagem Assistida por Computador/métodos , Programas de Rastreamento/métodos , Adenoma/epidemiologia , Adenoma/patologia , Idoso , Biópsia/estatística & dados numéricos , Colo/diagnóstico por imagem , Colo/patologia , Colonoscopia/instrumentação , Colonoscopia/estatística & dados numéricos , Neoplasias Colorretais/epidemiologia , Neoplasias Colorretais/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/instrumentação , Interpretação de Imagem Assistida por Computador/estatística & dados numéricos , Masculino , Programas de Rastreamento/instrumentação , Programas de Rastreamento/estatística & dados numéricos , Pessoa de Meia-Idade , Fatores de Tempo
8.
Clin Gastroenterol Hepatol ; 19(7): 1395-1401, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32687977

RESUMO

BACKGROUND AND AIMS: Granular mixed laterally spreading tumors (GM-LSTs) have an intermediate level of risk for submucosal invasive cancer (SMICs) without clear signs of invasion (covert); the optimal resection method is uncertain. We aimed to determine the risk of covert SMIC in GM-LSTs based on clinical and endoscopic factors. METHODS: We collected data from 693 patients (50.6% male; median age, 69 years) with colorectal GM-LSTs, without signs of invasion, who underwent endoscopic resection (74.2%) or endoscopic submucosal dissection (25.2%) at 7 centers in Italy from 2016 through 2019. We performed multivariate and univariate analyses to identify demographic and endoscopic factors associated with risk of SMIC. We developed a multivariate model to calculate the number needed to treat (NNT) to detect 1 SMIC. RESULTS: Based on pathology analysis, 66 patients (9.5%) had covert SMIC. In multivariate analyses, increased risk of covert SMIC were independently associated with increasing lesion size (odds ratio per mm increase, 1.02, 95% CI, 1.01-1.03; P = .003) and rectal location (odds ratio, 3.08; 95% CI, 1.62-5.83; P = .004). A logistic regression model based on lesion size (with a cutoff of 40 mm) and rectal location identified patients with covert SMIC with 47.0% sensitivity, 82.6% specificity, and an area under the curve of 0.69. The NNT to identify 1 patient with a nonrectal SMIC smaller than 4 cm was 20; the NNT to identify 1 patient with a rectal SMIC of 4 cm or more was 5. CONCLUSIONS: In an analysis of data from 693 patients, we found the risk of covert SMIC in patients with GM-LSTs to be approximately 10%. GM-LSTs of 4 cm or more and a rectal location are high risk and should be treated by en-bloc resection. ClinicalTrials.gov, Number: NCT03836131.


Assuntos
Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Idoso , Colonoscopia , Neoplasias Colorretais/epidemiologia , Endoscopia , Feminino , Humanos , Mucosa Intestinal , Masculino , Reto , Estudos Retrospectivos
9.
Am J Gastroenterol ; 116(9): 1853-1858, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34236338

RESUMO

INTRODUCTION: Multiple therapeutic modalities including surgery and rigid and flexible endoscopy have been adopted to manage Zenker's diverticulum (ZD). Minimally invasive flexible endoscopic septotomy (FES) techniques have been increasingly favored over the past 20 years; however, long-term data are still scanty. The aim of this study is to evaluate early and long-term outcomes of FES for naive ZD in a single-center setting. METHODS: From 2010 to 2017, ZD patients treated with FES were included in a prospectively maintained database (NCT03948438). Those who had already been treated surgically or endoscopically were excluded from the analysis. The Dakkak and Bennett dysphagia scale was used to rate the dysphagia. Persistent complete or near-complete resolution of symptoms (Dakkak and Bennett 0 or 1) was defined as clinical success. Postprocedural adverse events were reported according to ASGE lexicon. RESULTS: Overall, 256 consecutive patients were treated. Mean pouch size was 29.8 ± 11.3 mm. The procedure was successfully completed in all scheduled patients, with an early clinical success of 96.1%. Adverse events occurred in 3.5% (9/256) of patients. Eight of them were mild/moderate with no fatal events, whereas one patient required surgery. Recurrences occurred in 31.3% (80/256) of treated patients after a mean time of 9 ± 3 months and 95% of recurrences were treated by a second FES. At an average follow-up of 5.5 years, 95.3% of patients were asymptomatic after a mean number of 1.3 procedures. DISCUSSION: FES is a safe and effective treatment modality for patients with ZD. Recurrence rate is significant; however, endoscopic reintervention is associated with long-term relief of dysphagia.


Assuntos
Transtornos de Deglutição/cirurgia , Endoscopia/métodos , Divertículo de Zenker/cirurgia , Idoso , Idoso de 80 Anos ou mais , Bases de Dados Factuais , Transtornos de Deglutição/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Divertículo de Zenker/complicações
10.
Gastrointest Endosc ; 93(3): 597-604.e5, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32640200

RESUMO

BACKGROUND AND AIMS: EUS-guided biopsy sampling is the method of choice for obtaining pancreatic tissue. Next-generation sequencing (NGS) has been applied to EUS-guided biopsy sampling and may classify patients based on specific molecular profiles. Our study aimed to compare side-by-side the diagnostic yield achievable by genetic identification of somatic mutations detected with NGS versus histologic and cytologic typing in locally advanced pancreatic carcinoma (LAPC) in samples acquired under EUS guidance. METHODS: We conducted a prospective comparative pilot study at Humanitas Research Hospital. The study included 33 patients referred for LAPC who underwent EUS-guided tissue acquisition using a 22-gauge Franseen needle. Material was obtained for both pathologic diagnosis and DNA extraction and targeted NGS analysis with the AmpliSeq Comprehensive Panel v3 (Illumina Inc, San Diego, Calif, USA). Twenty-one genes were prioritized for somatic mutation detection. RESULTS: The final diagnosis was pancreatic ductal adenocarcinoma (PDAC) in all patients (100%). A macroscopic core was obtained in 30 patients (91%). In 3 lesions no cores adequate for histologic analysis were obtained, but cytologic analysis revealed tumoral cells from PDAC. DNA was extracted from 32 of 33 samples (97%), most of which (27/32) carried at least 2 clearly pathogenic mutations in different genes. Detection of K-ras mutation allowed for molecular diagnosis of PDAC in most of the patients (30/32). CONCLUSIONS: In our study we demonstrated that proper tissue specimens obtained under EUS guidance allowed DNA sample extraction and subsequent NGS analysis in 97% of cases. These results support the potential role of NGS as a complementary diagnostic test to be implemented in association with standard diagnostic modalities. (Clinical trial registration number: NCT03578939.).


Assuntos
Adenocarcinoma , Neoplasias Pancreáticas , Adenocarcinoma/diagnóstico , Adenocarcinoma/genética , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Neoplasias Pancreáticas/diagnóstico , Neoplasias Pancreáticas/genética , Projetos Piloto , Estudos Prospectivos , Neoplasias Pancreáticas
11.
Gastrointest Endosc ; 92(4): 900-904.e4, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32561410

RESUMO

BACKGROUND AND AIMS: False positive (FP) results by computer-aided detection (CADe) hamper the efficiency of colonoscopy by extending examination time. Our aim was to develop a classification of the causes and clinical relevance of CADe FPs, and to assess the relative distribution of FPs in a real-life setting. METHODS: In a post-hoc analysis of a randomized trial comparing colonoscopy with and without CADe (NCT: 04079478), we extracted 40 CADe colonoscopy videos. Using a modified Delphi process, 4 expert endoscopists identified the main domains for the reasons and clinical relevance of FPs. Then, 2 expert endoscopists manually examined each FP and classified it according to the proposed domains. The analysis was limited to the withdrawal phase. RESULTS: The 2 main domains for the causes of CADe FPs were identified as artifacts due to either the mucosal wall or bowel content, and clinical relevance was defined as the time spent on FPs and the FP rate per minute. The mean number of FPs per colonoscopy was 27.3 ± 13.1, of which 24 ± 12 (88%) and 3.2 ± 2.6 (12%) were due to artifacts in the bowel wall and bowel content, respectively. Of the 27.3 FPs per colonoscopy, 1.6 (5.7%) required additional exploration time of 4.8 ± 6.2 seconds per FP (ie, 0.7% of the mean withdrawal time). In detail, 15 (24.2%), 33 (53.2%), and 14 (22.6%) FPs were classified as being of mild, moderate, or severe clinical relevance. The rate of FPs per minute of withdrawal time was 2.4 ± 1.2, and was higher for FPs due to artifacts from the bowel wall than for those from bowel content (2.4 ± 0.6 vs 0.3 ± 0.2, P < .001). CONCLUSIONS: FPs by CADe are primarily due to artifacts from the bowel wall. Despite a high frequency, FPs result in a negligible 1% increase in the total withdrawal time because most of them are immediately discarded by the endoscopist.


Assuntos
Colonoscopia , Humanos
12.
Surg Endosc ; 34(9): 3845-3852, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-31586245

RESUMO

BACKGROUND: Multi-band mucosectomy (MBM) is effective and safe for Barrett's neoplasia. No studies have yet compared the efficacy and safety of the MBM devices commercially available: Duette™ (CookMedical) and Captivator™ (BostonScientific). Our aim is to compare the two devices. METHODS: This is a dual-center retrospective case-control study (Rozzano, Portsmouth) comparing efficacy, safety, and histology of resected specimens between Duette™ (DUE) and Captivator™ (CAPT). Efficacy was assessed by R0 and local recurrence (LR) rate. Bleedings, perforations, and strictures were recorded as safety outcomes. Moreover, the specimens were re-examined by two pathologists, blinded about the study group, to assess the maximum thickness of both the whole specimens and the resected submucosal layer. RESULTS: Seventy-six patients (38 per group) were included. The two groups did not differ in terms of baseline characteristics. R0 resection was achieved in 96.7% versus 96.3% (p = ns) and LR were recorded in 4/38 (10.5%) versus 3/38 (7.9%) in DUE and CAPT group, respectively (p = ns). Considering Duette™ versus Captivator™, 2 versus 3 patients developed a symptomatic stricture. Only one post-procedural bleeding occurred (Captivator™). Maximum medium thicknesses of specimens and of resected submucosa did not differ between the groups. CONCLUSIONS: MBM is safe and effective for resecting visible lesions using either of the two available devices.


Assuntos
Esôfago de Barrett/cirurgia , Procedimentos Cirúrgicos do Sistema Digestório/instrumentação , Neoplasias Esofágicas/cirurgia , Idoso , Estudos de Casos e Controles , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Esofagoscopia , Feminino , Seguimentos , Humanos , Masculino , Recidiva Local de Neoplasia/patologia , Estudos Retrospectivos
13.
Gastrointest Endosc ; 89(6): 1109-1116.e4, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30862352

RESUMO

BACKGROUND AND AIMS: Underwater EMR is an alternative way to have nonpedunculated colorectal lesions lifted before being resected. The endoscopist takes advantage of the behavior of mucosal lesions floating away from the muscular layer, once immersed in liquid. We performed a systematic review with meta-analysis to evaluate the efficacy and safety of this technique. METHODS: Electronic databases (Medline, Scopus, EMBASE) were searched up to May 2018. Full articles including patients with colorectal lesions resected by the underwater EMR technique were eligible. The complete resection (primary outcome), en bloc resection, recurrence, and adverse event rates were pooled by means of a random or fixed-effect model. RESULTS: Ten studies were eligible, providing data on 508 lesions removed from 433 patients (male/female = 239/194; mean age range 62.2-75.0 years). Six studies were performed in the United States and the other in Europe; 7 studies were prospective. The specific indications for performing underwater EMR varied widely across studies. The complete resection rate was 96.36% (95% confidence interval [CI], 91.77-98.44), with a rate of en bloc resection of 57.07% (95% CI, 43.20%-69.91%). The recurrence rate was 8.82% (95% CI, 5.78-13.25) in a mean endoscopy surveillance period of 7.7 months (range 4-15 months). The postprocedural bleeding rate was 2.85% (95% CI, 1.64-4.90). Bleeding during the procedure was always mild and was considered as part of the procedure in all series. The overall adverse event rate was 3.31% (95% CI, 1.97%-5.52%). No cases of perforation were reported. CONCLUSION: According to the results of this systematic review, underwater EMR appears to be an effective and extremely safe technique for resecting nonpolypoid colorectal lesions.


Assuntos
Adenoma/cirurgia , Carcinoma/cirurgia , Colonoscopia/métodos , Neoplasias Colorretais/cirurgia , Ressecção Endoscópica de Mucosa/métodos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA