Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Radiat Res ; 158(4): 424-42, 2002 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-12236810

RESUMO

Three somatic mutation assays were evaluated in men exposed to low-dose, whole-body, ionizing radiation. Blood samples were obtained between 1992 and 1999 from 625 Russian Chernobyl cleanup workers and 182 Russian controls. The assays were chromosome translocations in lymphocytes detected by FISH, hypoxanthine phosphoribosyltransferase (HPRT) mutant frequency in lymphocytes by cloning, and flow cytometic assay for glycophorin A (GPA) variant frequency of both deletion (N/Ø) and recombination (N/N) events detected in erythrocytes. Over 30 exposure and lifestyle covariates were available from questionnaires. Among the covariates evaluated, some increased (e.g. age, smoking) and others decreased (e.g. date of sample) biomarker responses at a magnitude comparable to Chernobyl exposure. When adjusted for covariates, exposure at Chernobyl was a statistically significant factor for translocation frequency (increase of 30%, 95% CI of 10%-53%, P = 0.002) and HPRT mutant frequency (increase of 41%, 95% CI of 19%-66%, P < 0.001), but not for either GPA assay. The estimated average dose for the cleanup workers based on the average increase in translocations was 9.5 cGy. Translocation analysis is the preferred biomarker for low-dose radiation dosimetry given its sensitivity, relatively few covariates, and dose-response data. Based on this estimated dose, the risk of exposure-related cancer is expected to be low.


Assuntos
Glicoforinas/genética , Hipoxantina Fosforribosiltransferase/genética , Mutação , Exposição Ocupacional , Centrais Elétricas , Liberação Nociva de Radioativos , Translocação Genética , Adulto , Biomarcadores , Citometria de Fluxo , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Fatores de Tempo , Ucrânia
2.
Mutat Res ; 536(1-2): 7-14, 2003 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-12694741

RESUMO

The pesticide phosphine (PH(3)) is a suspected carcinogen and a known clastogen which has been shown to produce chromosome damage in agricultural workers. To confirm and extend these results we evaluated 22 phosphine appliers and 26 controls matched for age and smoking status. Two independent methods were used to evaluate exposure: fluorescence in situ hybridization (FISH) with whole-chromosome paints of chromosomes 1, 2, and 4 labeled in a single color to quantify translocations in peripheral lymphocytes, and the glycophorin A (GPA) assay to quantify phenotypically mutant (NØ or NN) erythrocytes. No differences in the frequency of translocations were found in the phosphine appliers compared to the controls, and no effect of cigarette smoking was observed. However, a significant increase in the frequency of translocations with age (P<0.0001) was seen. No effect of phosphine exposure or cigarette smoking was observed in the GPA assay. These results are in contrast to previous findings from this same population which showed an increase in chromosome aberrations among phosphine appliers. The results are most easily interpreted as supporting the effectiveness of the personal protective equipment that is now worn by the workers but which was not employed prior to and during the earlier studies.


Assuntos
Monitoramento Ambiental/métodos , Inseticidas/efeitos adversos , Fosfinas/efeitos adversos , Translocação Genética , Adulto , Estudos de Casos e Controles , Eritrócitos/efeitos dos fármacos , Eritrócitos/metabolismo , Glicoforinas/efeitos dos fármacos , Glicoforinas/metabolismo , Humanos , Hibridização in Situ Fluorescente , Linfócitos/efeitos dos fármacos , Masculino , Pessoa de Meia-Idade , Exposição Ocupacional , Valores de Referência , Análise de Regressão , Fumar
3.
Bioinformatics ; 21(19): 3733-40, 2005 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-16091413

RESUMO

MOTIVATION: The DeCyder software (GE Healthcare) is the current state-of-the-art commercial product for the analysis of two-dimensional difference gel electrophoresis (2D DIGE) experiments. Analyses complementing DeCyder are suggested by incorporating recent advances from the microarray data analysis literature. A case study on the effect of smallpox vaccination is used to compare the results obtained from DeCyder with the results obtained by applying moderated t-tests adjusted for multiple comparisons to DeCyder output data that was additionally normalized. RESULTS: Application of the more stringent statistical tests applied to the normalized 2D DIGE data decreased the number of potentially differentially expressed proteins from the number obtained from DeCyder and increased the confidence in detecting differential expression in human clinical studies.


Assuntos
Algoritmos , Proteínas Sanguíneas/análise , Eletroforese em Gel Bidimensional/métodos , Perfilação da Expressão Gênica/métodos , Regulação da Expressão Gênica/efeitos dos fármacos , Proteoma/análise , Vacina Antivariólica/administração & dosagem , Simulação por Computador , Interpretação Estatística de Dados , Humanos , Modelos Biológicos , Modelos Estatísticos , Software
4.
Anal Chem ; 75(14): 3446-50, 2003 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-14570196

RESUMO

Continuous monitoring of the environment for infectious diseases and related biowarfare agents requires the implementation of practical cost-effective methodologies that are highly sensitive and specific. One compatible method employed in clinical diagnostics is real-time polymerase chain reaction (PCR) analysis. The utility of this technique for environmental monitoring is limited, however, by the utilization of single-use consumables in commercial PCR instruments. This greatly increases mechanical complexity, because sophisticated robotic mechanisms must replenish the disposable elements. An alternative strategy develops an autonomous monitoring system consisting of reusable modules that readily interface with fluidic circuitry in a flow-through scheme. The reduced complexity should increase reliability while decreasing operating costs. In this report, we describe a reusable, flow-through PCR module that functions as one component in such a system. This module was rigorously evaluated with Bacillus anthracis genomic DNA and demonstrated high repeatability, sensitivity, and efficiency, with no evidence of sample-to-sample carryover.


Assuntos
Doenças Transmissíveis/microbiologia , Reação em Cadeia da Polimerase/instrumentação , Algoritmos , Doenças Transmissíveis/diagnóstico , DNA/química , DNA/genética
5.
Anal Chem ; 75(8): 1924-30, 2003 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-12713052

RESUMO

Liquid array-based multiplexed immunoassays designed for rapid, sensitive, specific, and simultaneous detection of multiple simulants of biological warfare agents have been developed. In both blind and standard laboratory trials, we demonstrate the simultaneous detection of four simulant agents from a single sample. The challenge agents comprise broad classes of pathogens (virus, protein toxins, bacterial spores, vegetative cells). Assay performance of each analyte was optimized, and dose-response curves and the limits of detection (LODs) for individual analytes are presented. Assay performance, including dynamic range, sensitivity, and LODs for liquid arrays and enzyme-linked immunosorbant assay were compared and are shown to be similar. Maximum assay sensitivity is obtained in approximately 1 h, and good sensitivity is achieved in as little as 30 min. Although the sample matrixes are very complex, even for highly multiplexed assays the samples do not exhibit evidence of nonspecific binding, demonstrating that the assays also have high specificity.


Assuntos
Guerra Biológica/prevenção & controle , Imunoensaio , Bactérias/isolamento & purificação , Guerra Biológica/métodos , Microesferas , Toxinas Biológicas/análise , Vírus/isolamento & purificação
6.
Am J Nephrol ; 24(2): 268-74, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15031630

RESUMO

BACKGROUND: Serum protein profiling patterns can reflect the pathological state of a patient and therefore may be useful for clinical diagnostics. Here, we present results from a pilot study of proteomic expression patterns in hemodialysis patients designed to evaluate the range of serum proteomic alterations in this population. METHODS: Surface-enhanced laser desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS) was used to analyze serum obtained from patients on periodic hemodialysis treatment and healthy controls. Serum samples from patients and controls were first fractionated into six eluants on a strong anion exchange column, followed by application to four array chemistries representing cation exchange, anion exchange, metal affinity and hydrophobic surfaces. A total of 144 SELDI-TOF-MS spectra were obtained from each serum sample. RESULTS: The overall profiles of the patient and control samples were consistent and reproducible. However, 30 well-defined protein differences were observed; 15 proteins were elevated and 15 were decreased in patients compared to controls. Serum from 1 patient exhibited novel protein peaks suggesting possible additional changes due to a secondary disease process. CONCLUSION: SELDI-TOF-MS demonstrated consistent serum protein profile differences between patients and controls. Similarity in protein profiles among dialysis patients suggests that patient physiological responses to end-stage renal disease and/or dialysis therapy have a major effect on serum protein profiles.


Assuntos
Proteínas Sanguíneas/análise , Diálise Renal , Insuficiência Renal/sangue , Insuficiência Renal/terapia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
7.
Anal Chem ; 75(20): 5293-9, 2003 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-14710805

RESUMO

We have developed and tested a fully autonomous pathogen detection system (APDS) capable of continuously monitoring the environment for airborne biological threat agents. The system is designed to provide early warning to civilians in the event of a terrorist attack. The final APDS will be completely automated, offering aerosol sampling, in-line sample preparation fluidics, multiplexed detection and identification immunoassays, and orthogonal, multiplexed PCR (nucleic acid) amplification and detection. The system performance (current capabilities include aerosol collection, multiplexed immunoassays, sample archiving, data reporting, and alarming) was evaluated in a field test conducted in a Biosafety Level 3 facility, where the system was challenged with, and detected, a series of aerosolized releases containing two live, virulent biological threat agents (Bacillus anthracis and Yersinia pestis). Results presented here represent the first autonomous, simultaneous measurement of these agents.


Assuntos
Aerossóis/análise , Bacillus anthracis/isolamento & purificação , Imunoensaio/instrumentação , Yersinia pestis/isolamento & purificação , Anticorpos Antibacterianos/imunologia , Bacillus anthracis/imunologia , Bacillus subtilis/imunologia , Bioterrorismo/prevenção & controle , Reações Cruzadas/imunologia , Citometria de Fluxo/instrumentação , Corantes Fluorescentes/análise , Corantes Fluorescentes/química , Humanos , Imunoensaio/métodos , Técnicas Microbiológicas/métodos , Microfluídica , Microesferas , Ficoeritrina/análise , Ficoeritrina/química , Reprodutibilidade dos Testes , Esporos Bacterianos/imunologia , Esporos Bacterianos/isolamento & purificação , Yersinia pestis/imunologia
8.
Anal Chem ; 76(2): 373-8, 2004 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-14719885

RESUMO

The rapid chemical analysis of individual cells is an analytical capability that will profoundly impact many fields including bioaerosol detection for biodefense and cellular diagnostics for clinical medicine. This article describes a mass spectrometry-based analytical technique for the real-time and reagentless characterization of individual airborne cells without sample preparation. We characterize the mass spectral signature of individual Bacillus spores and demonstrate the ability to distinguish two Bacillus spore species, B. thuringiensis and B.atrophaeus, from one another very accurately and from the other biological and nonbiological background materials tested with no false positives at a sensitivity of 92%. This example demonstrates that the chemical differences between these two Bacillus spore species are consistently and easily detected within single cells in seconds.


Assuntos
Aerossóis/análise , Microbiologia do Ar , Esporos Bacterianos/isolamento & purificação , Bacillus/química , Bacillus/isolamento & purificação , Bacillus thuringiensis/química , Bacillus thuringiensis/isolamento & purificação , Clostridium/química , Clostridium/isolamento & purificação , Misturas Complexas/análise , Meios de Cultura/farmacologia , Espectrometria de Massas/métodos , Reprodutibilidade dos Testes , Esporos Bacterianos/classificação , Esporos Bacterianos/efeitos dos fármacos , Esporos Fúngicos/química , Esporos Fúngicos/classificação , Esporos Fúngicos/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA